An accelerometer has input range of 0 to 10g, natural frequency 30 Hz and mass 0.001 kg. The range of the secondary displacement transducer in mm required to cover the input range is

(A) 0 to 2.76 (B) 0 to 9.81 (C) 0 to 11.20 (D) 0 to 52.10

1 Answer

Answer :

An accelerometer has input range of 0 to 10g, natural frequency 30 Hz and mass 0.001 kg. The range of the secondary displacement transducer in mm required to cover the input range is 0 to 2.76

Related questions

Description : Explain how MEMS accelerometer is used as airbag sensor for car system.

Last Answer : MEMS Accelerometer is used as airbag sensor: Mechanical ignition airbags fit inside the steering wheel pad. When a collision occurs, the inertial sensor moves, setting off a ... the airbag with wiring. This is especially effective when fitting both driver- and passenger-side airbags.

Description : Explain the construction and working of LVDT accelerometer with the help of diagram.

Last Answer : Explanation:* The LVDT accelerometer consists of one primary and two secondary windings which are placed on either side of central code. The two ends of the core are connected with ... in the output terminal. This output voltage is directly proportional to the vibration or acceleration. 

Last Answer : Natural commutation is also called as line Communication. The turning off of thyristor due to AC supply is called natural commutation or line commutation. If the thyristor is connected to AC supply ... connected to positive and anode terminal get connected to negative, this turns off the thyristor.

Description : What is the frequency range of VHF electromagnetic waves? A) 30-300 kHz B) 30-3000 kHz C) 30-300 MHz D) 30-3000 MHz

Last Answer : What is the frequency range of VHF electromagnetic waves? A) 30-300 kHz B) 30-3000 kHz C) 30-300 MHz D) 30-3000 MHz

Description : Which of the following converts linear displacement from a mechanical reference into a proportional electrical signal containing phase and amplitude information? A) CRO B) LVDT C) RVDT D) None of these

Last Answer : Which of the following converts linear displacement from a mechanical reference into a proportional electrical signal containing phase and amplitude information? A) CRO B) LVDT C) RVDT D) None of these

Last Answer : In a capacitor start motor, the phase displacement between starting and running winding can be nearly 90°.

Description : A series R-L-C Circuit has a resonant frequency of 1000 Hz. If the values of R, L and C are doubled, the new resonant frequency is

Last Answer : A series R-L-C Circuit has a resonant frequency of 1000 Hz. If the values of R, L and C are doubled, the new resonant frequency is 500 Hz

Description : What would happen if a power transformer designed for operation on 50 Hz (frequency) were connected to a 500 Hz (frequency) source of the same voltage:  (A) Eddy Current and Hysteresis losses will be ... Current will be too much high  (C) Transformer may start to smoke and burn  (D) No effect

Last Answer : What would happen if a power transformer designed for operation on 50 Hz (frequency) were connected to a 500 Hz (frequency) source of the same voltage:  (A) Eddy Current and Hysteresis losses will be ... will be too much high  (C) Transformer may start to smoke and burn  (D) No effect

Description : For a 500 Hz frequency excitation, a 50 km long power line will be modeled as

Last Answer : For a 500 Hz frequency excitation, a 50 km long power line will be modeled as long line

Description : Two waves have frequency of 500 Hz. One is set at its maximum value whereas the other at zero. The phase angle between them will be

Last Answer : Two waves have frequency of 500 Hz. One is set at its maximum value whereas the other at zero. The phase angle between them will be 90o

Description : For a frequency of 200 Hz, the time period will be?

Last Answer : For a frequency of 200 Hz, the time period will be 0.005 s.

Last Answer :  A sine wave has a frequency of 50 Hz. Its angular frequency is 100 n radian/second.

Description : A 4 GHz carrier is amplitude modulated by a low-pass signal of maximum cut off frequency 1 MHz. lf this signal is to be ideally sampled, the minimum sampling frequency should be nearly

Last Answer : A 4 GHz carrier is amplitude modulated by a low-pass signal of maximum cut off frequency 1 MHz. lf this signal is to be ideally sampled, the minimum sampling frequency should be nearly 4 Ghz

Description : In a 741 Op-Amp, there is 20 dB/decade fall-off starting at a relatively low frequency. This is due to the (A) applied load (B) internal compensation (C) impedance of the source (D) power dissipation in the chip

Last Answer : In a 741 Op-Amp, there is 20 dB/decade fall-off starting at a relatively low frequency. This is due to the internal compensation

Last Answer : Yes MOSFET can operate at very high frequency.

Description : How to Build a Natural Gas Burnout Oven

Last Answer : How to Build a Natural Gas Burnout Oven How to Build a Natural Gas Burnout Oven Ever fancied making your own pizza or a homemade cake? Well, you can not only save big bucks but also make great baked ... the excess gas can escape. To do this try making a window on the top portion of the oven frame.

Description : Natural Aspirin

Last Answer : To keep your diet high in natural salicylates (the main ingredient in aspirin that helps prevent heart attacks), eat more oranges, raspberries, apricots and cherries. For additional salicylates, season foods with cinnamon, curry, cayenne and thyme.

Description : Best Natural Antioxidant Spice

Last Answer : Best Natural Antioxidant Spice - Cloves Researchers have identified cloves (Syzygium aromaticum) as the best natural antioxidant spice, because they contain high levels of phenolic compounds, as well as ... used in a Mediterranean diet . Flavour and Fragrance Journal 25, 13-19, February 2010.

Description : Organic Gardening Natural Gardening

Last Answer : Organic Gardening The Basics of Organic Gardening When we talk of organic gardening, some of us believe that it is a process where gardens are cultivated without the aid of synthetic chemicals to ... not only that, you also get to do your part in maintaining the balance of our environment.

Description : How to choose high quality and natural dairy products?

Last Answer : Dairy products have always been the basis of nutrition, and this is quite justified: after all, they contain only natural substances that contribute to normal digestion. However, in an effort to reduce ... kilogram. Real sour cream will only be called sour cream, and butter will be called butter.

Description : Differentiate between Natural and Forced commutation

Last Answer : Natural commutation Forced commutation Source is AC Source is DC External commutating componants are not required  External commutating componants are required SCR turns off ... in controlled rectifiers, AC voltage controllers etc.  Used in choppers & inverters etc

Description : Define natural, mechanical, forced and induced draught systems.

Last Answer : Natural draught system: - When the fuel is burnt (combustion) in the furnace due to natural circulation of air, the draught is called natural draught. Mechanical draught system: -  In a mechanical ... combustion. OR If fan/blower is placed after the furnace then it is called as induced draught

Last Answer : Natural air cooling is generally restricted for transformers up to 1.5 MVA .

Description : List two types of oscillator, which generates frequency in RF range.

Last Answer : Types of Oscillators generating frequencies in RF range: i) Hartley Oscillator ii) Colpitt’s Oscillator iii) Clapp Oscillator

Last Answer : In a vibrating reed frequency meter the natural frequencies of two adjacent reeds have a difference of 0.5 Hz.

Description : A 1 kg mass is suspended by a spring having a stiffness of 0.4 N/mm. Determine the natural frequency. A 20 rad/sec B 30 rad/sec C 20 Hz D 30 Hz

Last Answer : B 30 rad/sec

Description : Define transducer. State factors which are considered while selecting transducer for a particular application.

Last Answer : Transducer - It converts one form of signal into another form. A transducer is a device that is used to convert a physical quantity into its corresponding electrical signal. ... compatibility : The transducer should maintain input and output characteristic for the selected environmental condition.

Description : Define Analog Transducer and give examples of it

Last Answer : Analog Transducer: An analog transducer is a device that converts the input signal into a continuous DC signal of voltage or current. Examples: * Strain gauge * L.V.D.T * Thermocouple * Thermistor

Description : State principle of operation of piezo-electric transducer. State its application.

Last Answer : The piezoelectric element used for converting mechanical movement into electric signals. The mechanical deformation generates charges and this charge appears as a voltage across the electrodes.  ... destructive test (NDT) equipments 6. Piezoelectric materials are used in ultrasonic transducers. 

Description : Write example of each type (i) Primary transducer (ii) Active transducer (iii) Electrical transducer (iv) Digital transducer

Last Answer : (i) Active transducer:-Thermocouple, piezoelectric, photovoltaic cell (ii) Primary transducer:- Bourdon tube, bellows, (iii) Electrical transducer.:- LVDT,RVDT, Hall effect, strain gauge, ... , optical pyrometer, radiation pyrometer (iv) Digital transducer:- Linear Encoder, digital taco generator

Description : State the use of RADAR type level transducer & list two advantages.

Last Answer : Applications of radar type transducer: i) RADAR type level transducer is suitable for large tanks with range upto 200m for level measurement. ii) It is used for continuous level measurement. ... iii) Not affected by corrosive materials. iv) Can be used for hard to handle' applications.

Description : List any two materials for Piezoelectric transducer.

Last Answer : i) Quartz crystal, ii) Barium titanete , iii) Rochelle salt , iv) Lithium Sulphate, v) Potassium Dihydrogen phosphate.

Description : State the necessity of transducer.

Last Answer : Necessity of Transducer: Input quantity for most of the Instrumentation systems is non - electrical quantity. To convert non- electrical quantities like heat, pressure, level, flow rate, ... use electrical methods and techniques for measurement, manipulation and control, transducers are required.

Description : List four electric pressure transducer.

Last Answer : List of electric pressure measuring devices: 1. Diaphragm with strain gauge 2. Bourdon Tube with LVDT 3. Differential Pressure cell 4. Piezoelectric type pressure transducer 5. Capacitance pressure transducer 6. Optical Pressure transducer 7. Resistive pressure transducer 

Description : Define transducer. Give two examples.

Last Answer : Transducer - It converts one form of signal into another form. A transducer is a device that is used to convert a physical quantity into its corresponding electrical signal.  Classification - 1. Active transducer 2. Passive transducer 

Description : Piezoelectric Transducer is used to measure  (1) displacement (2) resistance (3) current (4) temperature

Last Answer : Piezoelectric Transducer is used to measure displacement 

Description : The transducer with negative temperature co-efficient of resistance is (A) Thermistor (B) Resistance Thermometer (C) Strain Gauge (D) Thermocouple

Last Answer : The transducer with negative temperature co-efficient of resistance is Thermistor

Description : What is a transducer and how does it work?

Last Answer : An electronic device that converts one form of energy to another form.for example a transducer is used in microphone to convert speech signals to electrical signal.on the other hand,transducer is used to convert an electrical signal to speech signals in speakers.

Description : What comes naturally to you that doesn't come naturally to everyone?

Last Answer : Common sense, apparently.

Description : What is the difference when someone sneezes when awake or asleep?

Last Answer : Well, when you sneeze while asleep, your pillow gets wet.

Description : What is the greatest thing to lay naked on or against?

Last Answer : Cool grass.

Description : What's your tree? (please see details)

Last Answer : When we used to bother, we simply pruned our mature white pines and brought a few boughs inside for some decorations and lights. Then we used the boughs for mulch.

Description : Which ancient warrior or tribal group, had the coolest look?

Last Answer : Those guys who colored themselves blue. It may be hard to provide photos since I don’t think there were cameras then.

Description : What makes something "artificial"?

Last Answer : I think this is a very interesting with a variety of answers. One example of the distinction I can think of is artificial or natural flavor additives. The natural ones are just as processed and is often ... I actually need to go, so I'll just leave my answer like this. There are other examples.

Description : Sinusoids find amplitude, period, frequency, voltage (Problem 1)

Last Answer : Sinusoids find amplitude, period, frequency, voltage (Problem 1)

Description : Principal of digital frequency meter.

Last Answer : The basic block diagram of basic digital frequency meter (DFM) is shown in above figure. The signal whose frequency we have to be measured is first to be amplified through amplifier. The output of amplifier ... = Number of counts. t = Time interval between start and stop condition of the gate.

Description : Define the following terms: 1) Virtual height 2) Actual height 3) Critical frequency. 4) Maximum usable frequency.

Last Answer : 1) Virtual height:- The incident and refracted rays follow paths that are exactly the same as they have been if reflection had taken place from a surface located at a greater height, called ... angle of incidence is other than the normal is known as maximum unstable frequency. MUF= fc secθ 

Description : Draw the diagram and explain the working of ferrodynamic type frequency meter. 

Last Answer : Ferrodynamic type frequency meter: (Electrical resonance type frequency meter): It consists of a fixed coil. The supply whose frequency is to be measured is connected across it. This coil ... so selected that the moving coil takes up a convenient position when frequency is of normal value. 

Description : List the different types of frequency meters.

Last Answer : Different types of frequency meters  1. Reed type [Mechanical type] 2. Ferro-dynamic type [Resonances type] 3. Weston type 4. Ratio-meter type 5. Saturable core type 6. Digital type

Description : Explain working of Weston type frequency meter.

Last Answer : Weston Type Frequency Meter: There are two fixed coils marked as A and B. Each coil divided into two equal parts and are fixed such that their magnetic axis are perpendicular to each ... leading to deflections in either direction depending on the currents there in, due to changed impedances.