Asynchronous circuits are usually faster than synchronous circuits because

1 Answer

Answer :

Asynchronous circuits are usually faster than synchronous circuits because they are free running and do not depend on the frequency of the clock

Related questions

Description : Compare Asynchronous sequential and synchronous sequential circuits.

Last Answer : SR. NO. ASYNCHRONOUS SEQUENTIAL CIRCUIT SYNCHRONOUS SEQUENTIAL CIRCUITS. 1 Output can be changed at any instant of time by changing the input Output changes at discrete ... the counter change state simultaneously. This is because all the flip-flops are clocked simultaneously.

Description : Compare characteristics of asynchronous and synchronous transmission mode (four points). 

Last Answer : Synchronous transmission Asynchronous transmission 1. Synchronous transmission are synchronized by an external clock. 1. Asynchronous transmission are synchronized by special signals along the transmission ... for transferring a small amount of data as it is simple and economical.

Description : Compare synchronous and asynchronous counter.

Last Answer : Asynchronous Counter Synchronous Counter In an Asynchronous Counter the output of one Flip Flop acts as the clock Input of the next Flip Flop. In a Synchronous Counter all the Flip Flop's are ... Also called as serial counter Also called as Parallel Counter

Description : Synchronous vs asynchronous logic

Last Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Description : What is the difference between synchronous and asynchronous motors?

Last Answer : The motor which rotates at constant speed is called synchronous motor. And that constant speed is called as synchronous speed.  And the motor which does not rotates at constant speed are called asynchronous motor. Asynchronous motor is also called as Induction motor.

Description : what is the difference between synchronous and asynchronous motor?

Last Answer : Asynchronous motors and syncrouns motor are called as dc machines.  and also syncrouns motor called as induction motor. Asynonymous motor as are rotates with constant speed we not able to operate . ... It is able to operate. These are a small difference between syncrouns and asynchronous motors. 

Description : An air gap is usually inserted in magnetic circuits to?

Last Answer : An air gap is usually inserted in magnetic circuits to prevent saturation.

Description : 12 Top Tips to Fall Asleep Faster and Stay Asleep Longer

Last Answer : How many times have you found yourself lying awake in bed, long after bedtime, just waiting to drift off - or worse, trying to force yourself to sleep? Most of us will have trouble getting to ... medical problem, so see a doctor if your sleep disturbances continue for more than a couple of weeks.

Description : How to Drive Uphill Faster

Last Answer : How to Drive Uphill Faster Encountering steep hills when driving is very common, and while it looks easy, it can be very difficult, especially for a beginner. If you want to drive a car uphill at a ... how to do it properly, you can easily master it. Just remember to keep safe while doing this.

Description : How to Digest Food Faster ?

Last Answer : How to Digest Food Faster Weight gain and constipation may be caused by slow food digestion. Boost your metabolism by knowing how to digest food faster. Chew Your Food Properly Food breakdown starts ... conditions caused by slow and improper food digestion. Eat healthy and be active all the time.

Description : How to Make Hair Grow Faster ?

Last Answer : How to Make Hair Grow Faster Having long locks is a desire of many people, especially women. Long hair gives the impression of beauty and elegance, which is why many of Hollywood's elite sport a ... before long, you will finally go through each day, as if you are living inside a shampoo commercial.

Description : How to Punch Faster ?

Last Answer : How to Punch Faster As a boxer or martial artist, you need to develop not just power but also speed when throwing punches. Speed and power are directly proportional when it comes to throwing punches. ... so work hard in the gym and punch faster like world boxing champion Manny Pacquiao in no time!

Description : How to Type Faster ?

Last Answer : How to Type Faster Touch typing and speed typing are essential skills in today's technology-driven age. While computers are very common these days, some people are still trying to get the hang of typing ... to speed up your typing pace, you can write words and input code faster than ever before.

Description : How to Run Faster ?

Last Answer : How to Run Faster Running speed is a combination of everything from weight, leg turnover (how fast your legs move), cardio conditioning and muscle. The following are 8 ways you can learn to run faster: ... course - run safely. Watch traffic. Do not overtrain. If injured, seek help (EG Shin splints)

Description : Which RAM is faster static or dynamic?

Last Answer : Static RAM are faster than dynamic RAM.

Last Answer : The efficiency of a properly designed synchronous motor will usually fall in range 85 to 95%.

Last Answer : The duration of sudden short-circuit test on a synchronous motor is usually about one second.

Description : Basic Op Amp Circuits

Last Answer : In this chapter we will be examining some common uses of op amps. Where Chapter Three focused on the theory of negative feedback in a more abstract way, this chapter zeroes in on the practical ... on using op amps with a single polarity power supply and how to increase the available output current.

Description : Explain the concept of initial and final conditions in switching circuits for elements R and L. 

Last Answer : Concept of Initial and final condition in switching circuits for R:  Consider a resistor is connected to a voltage source, using a switch as shown in fig below The switch is closed ... of value Io in parallel with short circuit.(I0 is the current in inductor just before switching)

Description : Explain with neat diagram series and parallel magnetic circuits. 

Last Answer : Series magnetic circuit: When different magnetic materials having different lengths, cross sectional areas and permeability are connected one after another, in which same flux is established in different sections, then it is called series ... flux, Φ = Φ1 + Φ2  Path 1: BAFE  Path 2: BACD

Description : Series rc circuits

Last Answer : Series rc circuits

Description : Circuits with XL Alone

Last Answer : Circuits with XL Alone X L values in series let two inductive reactances X L 1 and X L 2 are connected in series and has value 50 ohm and 50 ohm respectively. 100 volts A C ... phasor. And it is taken horizontal. Phase angle between inductive current and voltage is same 90 degree.

Description : AC Circuits with Resistance but No Reactance

Last Answer : AC Circuits with Resistance but No Reactance AC Circuits with Resistance but No Reactance Series resistances let two resistances R 1 and R 2 are connected in series as shows in figure and there ... voltage. Voltage V A is common to both the branch hence voltage V A is common reference.

Description : Nodal Analysis of Electric Circuits Example

Last Answer : Nodal Analysis of Electric Circuits Example 1 : https://youtu.be/XLS6kDQuHj0 Nodal Analysis of Electric Circuits Example 2 : https://youtu.be/OFhurvl74bA Nodal Analysis of Electric Circuits ... youtu.be/GmOozdjTVtM Nodal Analysis of Electric Circuits Example 9 : https://youtu.be/KjgfjJ7Ubb8

Description : What is the need of polarity marking in polyphase AC circuits?

Last Answer : Need of Polarity Marking in Polyphase AC Circuits: i) Polarity marking of terminals provides reference polarity for better understanding of system, even if the polarity of ac voltage changes ... of current transformers in relay protection circuit and getting desired performance is very difficult.

Description : State superposition theorem applied to D.C. circuits.

Last Answer : Superposition Theorem applied to D.C. circuits: Superposition theorem states that in any linear, bilateral, multisource network, the response (voltage across any element or current through any ... each source acting alone, while the other sources are replaced by their internal resistances.

Description : State two advantages of digital circuits.

Last Answer : Advantages of Digital Circuits: i) Digital circuits are easier to design. ii) Information storage is easy. iii) Accuracy and precision are greater. iv) Less affected by noise. v) Reliability is more

Description : Which of the following circuits converts any arbitrary waveform into square waveform? A) Hartley oscillator B) Schmitt trigger C) Differentiator D) RC phase shift oscillator 

Last Answer : Which of the following circuits converts any arbitrary waveform into square waveform? A) Hartley oscillator B) Schmitt trigger C) Differentiator D) RC phase shift oscillator 

Description : Which of the following is true at resonance in LC circuits? A) The series impedance of the two elements is at a maximum and the parallel impedance is at minimum B) The series impedance of the ... D) The series impedance of the two elements is at a minimum and the parallel impedance is at maximum

Last Answer : Which of the following is true at resonance in LC circuits? A) The series impedance of the two elements is at a maximum and the parallel impedance is at minimum B) The series impedance of ... D) The series impedance of the two elements is at a minimum and the parallel impedance is at maximum

Description : In AC. circuits, laminated iron is invariably used in order to?

Last Answer : In AC. circuits, laminated iron is invariably used in order to reduce eddy current loss.

Description : Which capacitors are suitable for DC filter circuits?

Last Answer : Electrolytic capacitors are suitable for DC filter circuits.

Description : Can you guys explain the advantages of frequency converter against the star delta or soft starter?

Last Answer : ¬Soft starters  A soft starter is, as you would expect, a device which ensures a soft starting of a motor. A softstarter has different characteristics to the other starting ... at rated current from zero to full speed. Frequency converters are becoming cheaper all the time.

Last Answer : Synchronous motors are generally not self-starting because the direction of instantaneous torque reverses after half cycle.

Description : Synchronous modems cost more than asynchronous modem because _______. A. They have larger bandwidth B. They are larger C. The production volume is larger D. They have clock recovery circuits

Last Answer : D. They have clock recovery circuits

Description : The synchronous modems are more costly than the asynchronous modems because a. they produce large volume of data b. they contain clock recovery circuits c. they transmit the data with stop and start bits d. they operate with a larger bandwidth e. none of above

Last Answer : they contain clock recovery circuits

Description : SYNCHRONOUS MOTORS MCQ

Last Answer : 101. In a synchronous motor it the back e.m.f. generated in the armature at noload is approximately equal to the applied voltage, then (a) the motor is said to be fully loaded (b) the torque ... square of the applied voltage (c) inversely proportional to applied voltage (d) none of the above Ans: a

Description : List different starting methods of three phase synchronous motor. Explain any one of them.

Last Answer : Different Starting Methods of Three Phase Synchronous Motor: As synchronous motor is not self starting, different methods of starting are as follows: 1) By using an Induction (Pony) motor 2) ... . The rotor gets pulled into synchronism and starts running at constant speed as a synchronous motor. 

Description : Draw and explain V and inverted V curves for synchronous motor.

Last Answer : V curves' and inverted V curves' for Synchronous Motor:  V curve:  V curve is a plot of the stator current versus field current for different constant loads. The graph is plotted ... Vcurves of synchronous motor. The highest point on each of these curves indicates unity power factor.

Description : List different torques in synchronous motor. 

Last Answer : Different Torques in Synchronous Motor: 1) Starting torque 2) Running torque 3) Pull-in torque 4) Pull-out torque

Description : Damper winding in a synchronous motor

Last Answer : Damper winding in a synchronous motor Serves to start the motor.

Description : Two synchronous generators G1, G2 are operating in parallel and are equally sharing KVAR (Lag) component of load. To shift part of KVAR from G2 to G1, while keeping terminal voltage fixed, the following action must be done

Last Answer : Two synchronous generators G1, G2 are operating in parallel and are equally sharing KVAR (Lag) component of load. To shift part of KVAR from G2 to G1, while keeping terminal voltage fixed, the following action must be done Raise If1 and lower If2

Description : In a synchronous machine, if the field flux axis ahead of the armature field axis in the direction of rotation, the machine is operating as  (1) synchronous motor (2) synchronous generator (3) asynchronous motor (4) asynchronous generator

Last Answer : In a synchronous machine, if the field flux axis ahead of the armature field axis in the direction of rotation, the machine is operating as synchronous generator 

Description : The 'Equal area criterion' for the determination of transient stability of a synchronous machine connected to an infinite bus  (1) ignores line as well as synchronous machine resistance ... consideration the possibility of machine losing synchronism after it has survived during the first swing.

Last Answer : 1

Description : Damper winding is provided in 3 phase synchronous motors to :

Last Answer : Damper winding is provided in 3 phase synchronous motors to : provide starting torque and prevent hunting

Description : In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load  (A) The armature current increases and the power factor decreases  (B) The armature ... but is lagging  (D) The armature current decreases and the power factor increases and is leading

Last Answer : In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load The armature current decreases and the power factor increases and is leading

Description : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole)  (A) has q -axis current only (B) has d -axis current only (C) has both d and q axis currents (D) cannot be divided between q and d axis currents

Last Answer : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole) has d -axis current only

Description : In a synchronous generator delivering lagging power factor load  (1) the excitation emf leads terminal voltage by the power angle (2) the excitation emf lags terminal voltage by the power angle (3) ... by the power factor angle (4) excitation emf lags the terminal voltage by the power factor angle

Last Answer : In a synchronous generator delivering lagging power factor load the excitation emf leads terminal voltage by the power angle

Description : In a self-controlled synchronous motor fed from a variable frequency inverter  (1) the rotor poles invariably have damper windings  (2) there are stability problems  (3) the speed of the rotor decides stator frequency  (4) the frequency of the stator decides the rotor speed

Last Answer : 2

Description : During a disturbance on a synchronous machine, the rotor swings form A to B before finally setting down to steady state at point C on the power angle curve. The speed of the machine during oscillation is synchronous at point(s)

Last Answer : During a disturbance on a synchronous machine, the rotor swings form A to B before finally setting down to steady state at point C on the power angle curve. The speed of the machine during oscillation is synchronous at point(s) only at C

Description : Two synchronous generators operating in parallel supply a common load of 2.5 MW. The frequency-power characteristics have a common slope of 1 MW/Hz and the no-load frequencies of the generators are 51.5 Hz and 51.0 Hz, ... system frequency is (A) 50 Hz (B) 51 Hz (C) 51.25 Hz (D) 51.5 Hz