A moving coil meter has a resistance of 3 Ω and gives full scale deflection with 30 mA. To measure voltage up to 300 V, the external resistance to be connected in series with the instrument is

(A) 9997 Ω (B) 10000 Ω (C) 997 Ω (D) 10003 Ω

1 Answer

Answer :

A moving coil meter has a resistance of 3 Ω and gives full scale deflection with 30 mA. To measure voltage up to 300 V, the external resistance to be connected in series with the instrument is 9997 Ω

Related questions

Description : A moving coil of meter has 100 turns, and a length and depth of 10mm and 20mm respectively. It is positioned in a uniform radial flux density of 200 mT. The coil carrier current capacity is 50 mA. The torque on the coil is

Last Answer : A moving coil of meter has 100 turns, and a length and depth of 10mm and 20mm respectively. It is positioned in a uniform radial flux density of 200 mT. The coil carrier current capacity is 50 mA. The torque on the coil is 200µNm

Last Answer : The multiplier and the meter coil in a voltmeter are in series.

Last Answer : A moving-coil permanent-magnet instrument can be used as flux-meter by eliminating the control springs.

Last Answer : A moving-coil permanent-magnet instrument can be used as ammeter by using a low resistance shunt.

Description : A PMMC instrument has FSD of 100 μA and a coil resistance of 1 kΩ. To convert the instrument into an ammeter with full scale deflection of 100 mA, the required shunt resistance is (A) 1 Ω (B) 1.001 Ω (C) 0.5 Ω (D) 10 Ω

Last Answer : A PMMC instrument has FSD of 100 μA and a coil resistance of 1 kΩ. To convert the instrument into an ammeter with full scale deflection of 100 mA, the required shunt resistance is 1.001 Ω

Description : Name the material used for :- (i) Moving coil (ii) Permanent magnet in PMMC instrument.

Last Answer : (i) Material used for Moving coil: Copper, Aluminum( some times)  (ii) Permanent magnets are made of special alloys such as :  Aluminum-Nickel-Cobalt (Alnicos)  Strontium-Iron  Neodymium-Iron-Boron  Samarium-Cobalt.

Description : State the material used for moving coil and former for PMMC instruments. 

Last Answer : Material Used for Moving Coil and Former for PMMC Instruments:  Material used for moving coil: Copper  Material used for Former: Aluminium

Description : Permanent magnet moving coil instruments are used for

Last Answer : PMME are mostly used for measuring voltage and current.

Description : State the use of shunt and series resistance used in extension of meter.

Last Answer : Use of shunt and series resistance: i) Use of shunt: To extend the range of Ammeter. ii) Use of series resistance: To extend the range of Voltmeter.

Description : When the voltage across a battery is measured using a D.C potentiometer, the reading shows 1.08 V. But when the same voltage is measured using a Permanent Magnet Moving Coil (PMMC) voltmeter, the voltmeter reading shows 0.99 ... resistance of the battery, in Ohm , is (A) 150 (B) 100 (C) 50 (D) 200

Last Answer : When the voltage across a battery is measured using a D.C potentiometer, the reading shows 1.08 V. But when the same voltage is measured using a Permanent Magnet Moving Coil (PMMC) voltmeter, ... resistance of the voltmeter is 1100 Ohm , the internal resistance of the battery, in Ohm , is 100

Description : A galvanometer has a coil of resistance `100 Omega` and gives a full-scale deflection for `30 mA` current. If it is to work as a voltmeter of `30 V` r

Last Answer : A galvanometer has a coil of resistance `100 Omega` and gives a full-scale deflection for `30 mA` current. ... Omega` C. `1000 Omega` D. `1800 Omega`

Description : A galvanometer of 65 Ω resistance gives full scale deflection with 4 mA current. In order to convert it into ammeter, the range of 10 A is connected with it, the shunt resistance should be a) 0.1 Ω b) 0.2 Ω c) 0.06 Ω d) 0.03 Ω

Last Answer : d) 0.03 Ω

Description : A 200 V, 5 A d.c. energy meter is tested at its marked ratings. The resistance of the pressure circuit is 8000 Ω and that of current coil is 0.1 Ω. The power consumed when testing the meter with phantom loading with current circuit excited by a 6 V battery is (A) 2.5 W (B) 5 W (C) 32.5 W (D) 35 W

Last Answer : A 200 V, 5 A d.c. energy meter is tested at its marked ratings. The resistance of the pressure circuit is 8000 Ω and that of current coil is 0.1 Ω. The power consumed when testing the meter with phantom loading with current circuit excited by a 6 V battery is 35 W

Description : The potential coil of a single phase dynamometer wattmeter has 4840 Ohm resistance. Voltage across the load is 220 V. With the potential coil connected on the load side, the meter indicates 100 W. Approximate percentage error due to wattmeter connection is (A) 11% (B) 9% (C) 1.1% (D) 3%

Last Answer : The potential coil of a single phase dynamometer wattmeter has 4840 Ohm resistance. Voltage across the load is 220 V. With the potential coil connected on the load side, the meter indicates 100 W. Approximate percentage error due to wattmeter connection is 11%

Description : A permanent magnet moving coil instrument gives full scale deflection of 25mA when a voltage of 75mV is applied across it. Calculate: (i) Resistance of shunt required for full scale deflection of 150 A. (ii) Series resistance for full scale deflection of 500 V.

Last Answer : Answer :

Description : RC triggering is preferred over resistance triggering because (A) it provides triggering at a precise instant (B) it gives a longer duration gate pulse (C) it enables triggering at a larger value of firing angle (D) it protects the SCR against high dv/dt

Last Answer : a

Description : A galvanometer with 20 ohms coil resistence has a full-scale deflection of 10 mA. A 0.02 ohm is placed across the meter to increase its rating capacity. What is the new full scale current for the meter?

Last Answer : False.

Description : Calculate the resistance of shunt required to make a milliammeter which gives maximum deflection for a current of 15 mA and which has a resistance of 5 Ω; read up to 10 Amp.

Last Answer : Answer :

Description : A moving coil instrument has a resistance of 10 W and gives full scale deflection when carrying a current of 50 mA. To measure current upto 100 A, we will have to connect • 10 W resistance in series • 10 W resistance in parallel • 10/1999 W resistance in series • 10/1999 W resistance in parallel

Last Answer : A moving coil instrument has a resistance of 10 W and gives full scale deflection when carrying a current of 50 mA. To measure current upto 100 A, we will have to connect 10/1999 W resistance in parallel

Last Answer : In a dynamometer 3-phase power factor meter, the planes of the two moving coils are at 120°.

Description : Draw venture meter and write steps to measure flow rate.

Last Answer : Venturi meter consists of three sections that is converging section, throat section and diverging section. The flow is introduced to the meter through the inlet with diameter D' . The inclined angle ... to 15o . Flow rate is proportional to the square root of the differential pressure.

Description : What type of meter is used to measure current?

Last Answer : Ammeter

Description : Consider a cube of material of sides 1 cm with a resistance of 0.003 Ω between its opposite faces. What is the resistance if the same volume of the material is drawn into a length of 50 cm with a uniform cross – section? A) 0.003 Ω B) 0.15 Ω C) 7.5 Ω D) None of these

Last Answer : Consider a cube of material of sides 1 cm with a resistance of 0.003 Ω between its opposite faces. What is the resistance if the same volume of the material is drawn into a length of 50 cm with a uniform cross – section? A) 0.003 Ω B) 0.15 Ω C) 7.5 Ω D) None of these

Description : What is the total resistance if 5 resistors of 20 Ω each are connected in series? A) 100 Ω B) 4 Ω C) 20 Ω D) None of these

Last Answer : What is the total resistance if 5 resistors of 20 Ω each are connected in series? A) 100 Ω B) 4 Ω C) 20 Ω D) None of these

Description : What do you mean by coil?

Last Answer : Ans. Having one or more turns connected in series is called coil.

Description : State the function of overload coil and No volt coil in dc motor starter.

Last Answer : Function of Overload Coil: When DC motor is overloaded, the overload coil carries the overload current and produces strong magnetic field to attract a plunger, which short the terminals of ... dc motor is prevented from restarting automatically on recovery of supply without starter and protected.

Description : The purpose of the restraining coil in a biased differential relay is  (A) To reduce CT saturation during fault.  (B) To increase the sensitivity of the relay.  (C) To match the transformation ratio.  (D) To limit the spill current through the relay during heavy external fault.

Last Answer : d

Description : Peterson coil is used for :  (A) shunt compensation of lines (B) grounding of system neutral (B) reduce fault currents (D) connecting interconnected systems

Last Answer : Peterson coil is used for : grounding of system neutral

Description : A Peterson coil is ________ A) An arc generating coil B) An arc suppressing coil C) An arc inducing coil D) None of these

Last Answer : A Peterson coil is An arc suppressing coil

Description : The self inductance of a coil can be measured using (A) Wien’s Bridge (B) Schering Bridge (C) Anderson’s Bridge (D) Wheatstone Bridge

Last Answer : The self inductance of a coil can be measured using Anderson’s Bridge

Description : lt the length, number of turns and area of a coil are  doubled, the inductance of the coil

Last Answer : lt the length, number of turns and area of a coil are  doubled, the inductance of the coil is quadrupled

Description : The initial rate of rise of current through a coil of inductance 10 H when suddenly connected to a D.C. supply of 200 V is_______Vs.

Last Answer : The initial rate of rise of current through a coil of inductance 10 H when suddenly connected to a D.C. supply of 200 V is 20 Vs

Description : The rate of rise of current through an inductive coil is maximum?

Last Answer : The rate of rise of current through an inductive coil is maximum at the start of the current flow.

Description : The inductance of a coil can be increased by?

Last Answer : The inductance of a coil can be increased by choosing core material having high relative permeability.

Description : Inductance of coil?

Last Answer : Inductance of coil increases with the increase in supply frequency.

Description : Inductance of a coil Varies?

Last Answer : Inductance of a coil Varies as directly as the cross-sectional area of magnetic core and inversely as the length of the iron path.

Last Answer : In a low power factor wattmeter the compensating coil is connected in series with pressure coil.

Last Answer : In a low power factor wattmeter the pressure coil is connected to the load side of the current coil.

Last Answer : Armature coil is short circuited by brushes when it lies along neutral axis.

Last Answer : Open circuited armature coil of a D.C. machine is identified by the scarring of the commutator segment to which open circuited coil is connected and indicated by a spark completely around the commutator.

Last Answer : In a shaded pole motor, the shading coil usually consist of a single turn of heavy copper wire which is short-circuited and carries only induced current.

Description : What is the difference between a coil and an inductor?

Last Answer : Inductor is covering with insulating material is called coil.so they differentiate between coil and inductor.

Description : An unshielded moving iron voltmeter is used to measure the voltage in an AC circuit. The stray DC magnetic field having a component along the axis will be  (1) unaffected (2) decreased (3) increased (4) either decreased or increased depending on the direction of the DC field

Last Answer : An unshielded moving iron voltmeter is used to measure the voltage in an AC circuit. The stray DC magnetic field having a component along the axis will be either decreased or increased depending on the direction of the DC field

Description : What is the resistance of a coil which draws 10 A and dissipates 1520 W? A) 152 Ω B) 15.2 Ω C) 1.52 Ω D) None of these

Last Answer : What is the resistance of a coil which draws 10 A and dissipates 1520 W? A) 152 Ω B) 15.2 Ω C) 1.52 Ω D) None of these

Description : When both the inductance and resistance of a coil are doubled the value of?

Last Answer : When both the inductance and resistance of a coil are doubled the value of time constant remains unchanged.

Description : A permanent magnet moving coil ammeter has a coil resistance of 99 ohm and Full Scale Deflection (FSD) current of 0.1mA. Shunt resistance is 1 ohm. Current through the meter at 0.5 F.S.D is:

Last Answer : A permanent magnet moving coil ammeter has a coil resistance of 99 ohm and Full Scale Deflection (FSD) current of 0.1mA. Shunt resistance is 1 ohm. Current through the meter at 0.5 F.S.D is: 0.05mA

Description : An ammeter has a full-scale deflection current of 100mA. If the same ammeter is used to measure a full-scale current of 1.0ampere, what is the value of the shunt resistor in ohms if the voltage across the meter is 9.0 volts?

Last Answer : 10 ohms

Last Answer : An induction meter can handle current up to 100 A.

Description : Would this gauss meter be any good?

Last Answer : answer:Oooo!!! Did you get the Chony? Made in Mississigua Ont? I have one of those and love it. I cannot tell about the gauss meter. TI could be anything. Sorry. The Chony on the other hand is fantastic.

Description : What is meter rule

Last Answer : It is a one meter long graduated stick. It is used to measure the length of an object or distance between two points. A meter rule is divided into 100 equal parts, each part is equal to one centi meter.