An induction type energy meter is found to run fast. Correction for this error can be made by 

(A) Over-load compensation.

(B) Voltage compensation.

(C) Moving the brake magnet away from the centre of the disc.

(D) Moving the brake magnet towards the centre of the disc.

1 Answer

Answer :

An induction type energy meter is found to run fast. Correction for this error can be made by Moving the brake magnet away from the centre of the disc.

Related questions

Description : State the function and shape of following parts used in induction type energy meter: i) Series magnet ii) Shunt magnet iii) Al disc iv) Brake magnet

Last Answer : i) Series magnet: produce flux proportional to current (load current) of circuit and interact in the aluminum disc with flux produced by voltage magnet for torque production. Its shape is like letter U.  ii) ... : brakes the motion of the aluminum disc or slows it down. Its shape is like letter C. 

Description : Draw a neat sketch of 1-ph induction type energy meter and write operating principle of it. 

Last Answer : Operating Principal:- The disc is placed between the two-flux due to pressure coil and flux due to current coil, which will set up torque on the disc which is proportional to power causing the ... is proportional to voltage, the second carries a current coil so its flux is proportional to current.

Description : List any four errors in induction type energy meter. Give method of compensation for each.

Last Answer : Errors in Induction Type Energy Meter with their Compensation:  1) Error due to friction: This error can be compensated by the additional shading band provided on the shunt electromagnet.  2) Phase ... error: This error can be compensated by providing a flux diverter' to the current magnet. 

Last Answer : Induction type single phase energy meters measure electric energy in kWh.

Description : Why energy meter is integrating type measuring instrument?

Last Answer : Energy Meter is Integrating Type Measuring Instrument: Energy meter is used for measurement of energy, which is obtained by integration (summation) of power supplied over the particular time duration, hence it the integrating type measuring instrument. 

Last Answer : An induction meter can handle current up to 100 A.

Description : For measurement of radio frequency ac signals __________ type meter is used

Last Answer : For measurement of radio frequency ac signals thermo-couple type meter is used

Description : What type of meter is used to measure current?

Last Answer : Ammeter

Description : The disc of a single phase Induction-type energy meter makes 60 revolutions in 6 minutes. Meter Constant is 1200 rev/kWh. Power consumption in the load is (A) 1.2 kW (B) 1 kW (C) 600 W (D) 500 W

Last Answer : The disc of a single phase Induction-type energy meter makes 60 revolutions in 6 minutes. Meter Constant is 1200 rev/kWh. Power consumption in the load is 500 W

Description : A 200 V, 5 A d.c. energy meter is tested at its marked ratings. The resistance of the pressure circuit is 8000 Ω and that of current coil is 0.1 Ω. The power consumed when testing the meter with phantom loading with current circuit excited by a 6 V battery is (A) 2.5 W (B) 5 W (C) 32.5 W (D) 35 W

Last Answer : A 200 V, 5 A d.c. energy meter is tested at its marked ratings. The resistance of the pressure circuit is 8000 Ω and that of current coil is 0.1 Ω. The power consumed when testing the meter with phantom loading with current circuit excited by a 6 V battery is 35 W

Last Answer : The adjustment of position of shading bands, in an energy meter is done to provide friction compensation.

Last Answer : The household energy meter is an integrating instrument.

Description : Describe principle of operation of Doppler type ultrasonic flow meter with diagram. 

Last Answer : Diagram: Working:  The flow meter consists of a crystal transducer mounted outside the pipe in which flow is to be measured. This transducer is a piezoelectric crystal which ... , so the frequency of the reflected wave is shifted to particle velocity, according to Doppler principle.

Description : Draw the diagram and explain the working of ferrodynamic type frequency meter. 

Last Answer : Ferrodynamic type frequency meter: (Electrical resonance type frequency meter): It consists of a fixed coil. The supply whose frequency is to be measured is connected across it. This coil ... so selected that the moving coil takes up a convenient position when frequency is of normal value. 

Description : With a neat sketch explain working of 1 phase dynamometer type power factor meter.

Last Answer : Working of 1 phase dynamometer type power factor meter : The current coil is connected in series with load. Two pressure coils marked as A and B are connected across the supply terminals ... becomes stationary and the pointer shows steady deflection corresponding to the power factor of the load. 

Description : Explain working of Weston type frequency meter.

Last Answer : Weston Type Frequency Meter: There are two fixed coils marked as A and B. Each coil divided into two equal parts and are fixed such that their magnetic axis are perpendicular to each ... leading to deflections in either direction depending on the currents there in, due to changed impedances.

Description : State the meaning of creeping error in 1 phase energy meter.

Last Answer : Creeping error: It is defined as the slow and continuous rotation of the disc of the energy-meter when only pressure coil is energized with no current in the current coil (load current = 0). ... magnet on this iron wire is sufficient to prevent continues rotation of the disc on no load condition.

Description : In the induction type directional over current relay, when a short-circuit occurs in the circuit (A) power flows in reverse direction (B) power flows in normal direction (C) directional power element does not operate (D) over current element is not energized

Last Answer : In the induction type directional over current relay, when a short-circuit occurs in the circuit power flows in reverse direction

Last Answer : The torque produced in induction type relay (shaded pole structure) is inversely proportional to the square of the current.

Description : Explain the “mitigation of power theft” and “faulty meter replacement” for energy conservation techniques to reduce commercial losses. 

Last Answer : Energy conservation techniques to reduce commercial losses:  1. Mitigation of Power Theft: Power theft being the most important issue which all of the service providing utilities ... agricultural sector. Prepaid meters may prove effective measures against unauthorized abstraction of energy. 

Description : Draw a block diagram of electronic energy meter. Write function of each block.

Last Answer : Electronic Energymeter  Functions of components/blocks: - CT reduces current to reasonable value for current scaling network. - Voltage & current scaling networks reduce proportionally the voltage ... ADC converts the square wave frequency analog output to display the energy in watthour.

Description : Draw and describe working of electronic energy meter.

Last Answer : working of electronic energy meter:- 1. CT reduces current to reasonable value for current scaling network. 2. Voltage & current scaling networks reduce proportionally the voltage & ... The ADC converts the square wave frequency analog output to display the energy in watthour. 

Description : What is meant by energy meter constant?

Last Answer : Energy Meter Constant  A fixed value which is used when converting meter readings to actual energy use, especially when potential transformers and similar types of equipment are used in metering. For example, K=--------rev/Kwh

Description : With neat diagram explain calibration of energy meter by direct loading method.

Last Answer : Calibration of Energy Meter by Direct Loading Method:  There are three methods for testing/calibration:  1. Long period dial test  2. Using rotary sub- standard meter  3. Using precision grade instruments  All ... of substandard meter in kWh  Then % error = [(D - DS)/DS] x 100

Description : Write any two advantages of digital energy meter.

Last Answer : Advantages of Digital Energy Meter: 1) Easy to read. 2) High accuracy 3) High resolution. 4) No frictional losses as there are no moving parts. 5) No requirement for external adjustments. 6) Large ... due to absence of moving parts. 7) Highly efficient. 8) Very much compact. 9) Good reliability.

Description : Phantom loading for testing of energy meter is used (A) to isolate the current and potential circuits (B) to increase power loss during testing (C) for meters having low current ratings (D) to test meters having a large current rating for which loads may not be available

Last Answer : B

Description : List the energy conservation technique in induction motor. 

Last Answer : Following are the list of energy conservation techniques in electrical motors: 1) Reduction in iron losses by using low loss silicon steel core material laminated to thinner dimension. 2) Using bigger length ... at light load. 13) By rewinding in induction motor 14) By motor survey

Last Answer : Energy conservation technique in induction motor by minimizing idle and redundant running of motor: 1) Loss of energy as the no load power drawn is approximately about 12% to 16% of rated ... to unnecessary line losses. 4) Reduction in overall system energy efficiency over period of time.

Description : Explain energy conservation technique “by improving power quality” for induction motor.

Last Answer : Energy conservation method in induction motor by improving power quality: Electrical energy can be conserved by improving the power quality. It can be achieved by avoiding voltage unbalance, maintaining ... losses can be minimized by using harmonic filter thus reducing the harmonics in the system.

Description : Blackt Electrotech 230V 24x7 Energy Saving Socket Type Digital Programmable Plastic Electronic Timer (White)

Last Answer : Buy from amazon: https://amzn.to/2SUTSdv Buy: http://bit.ly/2ZqlAkS

Description : A moving coil of meter has 100 turns, and a length and depth of 10mm and 20mm respectively. It is positioned in a uniform radial flux density of 200 mT. The coil carrier current capacity is 50 mA. The torque on the coil is

Last Answer : A moving coil of meter has 100 turns, and a length and depth of 10mm and 20mm respectively. It is positioned in a uniform radial flux density of 200 mT. The coil carrier current capacity is 50 mA. The torque on the coil is 200µNm

Description : The meter which does not have any component in it to provide control torque is (A) Electrodynamometer for current measurement (B) Electrodynamometer for voltage measurement (C) Electrodynamometer for power measurement. (D) Electrodynamometer for power factor measurement.

Last Answer : The meter which does not have any component in it to provide control torque is Electrodynamometer for power factor measurement.

Last Answer : A Weston frequency meter is moving iron instrument.

Last Answer : In a Weston frequency meter, the magnetic axes of the two fixed coils are perpendicular.

Last Answer : In a vibrating reed frequency meter the natural frequencies of two adjacent reeds have a difference of 0.5 Hz.

Last Answer : In a dynamometer 3-phase power factor meter, the planes of the two moving coils are at 120°.

Last Answer : In a single phase power factor meter the phase difference between the currents in the two pressure coils is exactly 90°.

Last Answer : The two pressure coils of a single phase power factor meter have the same dimensions and the same number of turns.

Last Answer : A power factor meter has one current circuit and two pressure circuits.

Last Answer : The multiplier and the meter coil in a voltmeter are in series.

Last Answer : An induction wattmeter can be used for A.C. 

Last Answer : For handling greater currents induction wattmeters are used in conjunction with current transformers.

Description : Generally, Crawling in squirrel cage induction motors is tendency to run stably at speeds as low as (A) One-third of their synchronous speed (B) One-fifth of their synchronous speed (C) One-seventh of their synchronous speed (D) One-ninth of their synchronous speed

Last Answer : Generally, Crawling in squirrel cage induction motors is tendency to run stably at speeds as low as One-seventh of their synchronous speed

Last Answer : The repulsion-start induction-run motor is used because of high starting torque.

Description : Would this gauss meter be any good?

Last Answer : answer:Oooo!!! Did you get the Chony? Made in Mississigua Ont? I have one of those and love it. I cannot tell about the gauss meter. TI could be anything. Sorry. The Chony on the other hand is fantastic.

Description : What is meter rule

Last Answer : It is a one meter long graduated stick. It is used to measure the length of an object or distance between two points. A meter rule is divided into 100 equal parts, each part is equal to one centi meter.

Description : Draw venture meter and write steps to measure flow rate.

Last Answer : Venturi meter consists of three sections that is converging section, throat section and diverging section. The flow is introduced to the meter through the inlet with diameter D' . The inclined angle ... to 15o . Flow rate is proportional to the square root of the differential pressure.

Description : List variable flow meter. 

Last Answer : 1. Variable area : Rotameter 2. Variable head : a) Venturi b) Orifice c) Pitot tube d) Nozzle

Description : working of distortion factor meter with block diagram

Last Answer : Working : Initially the switch S is kept at position 1.The attenuator gets excluded and the bridge T network is adjusted for full suppression of fundamental frequency and hence we get ... is obtained on the meter.Thus the total rms distortion is indicated by the reading of attenuator.