Torque angle for the synchronous machine is the angle between

(A) stator magnetic field and rotor magnetic field

(B) stator magnetic field and net magnetic field in the air gap

(C) rotor magnetic field and net magnetic field in the air gap

(D) excitation voltage and impedance voltage drop

1 Answer

Answer :

Torque angle for the synchronous machine is the angle between rotor magnetic field and net magnetic field in the air gap

Related questions

Description : What is the maximum value of torque angle in synchronous motor?

Last Answer : The maximum value of torque angle in synchronous motor is 90 degrees electrical.

Description : The power factor angle and torque angle of a salient pole synchronous generator drawing a current of 1.0 pu from a lagging load are 45o and 15o, respectively. The direct axis and quadrature axis currents, respectively, are (A) 0.5 pu ... pu, 0.5 pu (C) 0.707 pu, 0.707 pu (D) 0.5 pu, 0.5 pu

Last Answer : The power factor angle and torque angle of a salient pole synchronous generator drawing a current of 1.0 pu from a lagging load are 45o and 15o, respectively. The direct axis and quadrature axis currents, respectively, are 0.866 pu, 0.5 pu

Description : In a synchronous machine, if the field flux axis ahead of the armature field axis in the direction of rotation, the machine is operating as  (1) synchronous motor (2) synchronous generator (3) asynchronous motor (4) asynchronous generator

Last Answer : In a synchronous machine, if the field flux axis ahead of the armature field axis in the direction of rotation, the machine is operating as synchronous generator 

Description : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole)  (A) has q -axis current only (B) has d -axis current only (C) has both d and q axis currents (D) cannot be divided between q and d axis currents

Last Answer : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole) has d -axis current only

Last Answer : A synchronous motor can develop synchronous torque at synchronous speed.

Description : The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as?

Last Answer : The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as pull-in torque.

Last Answer : The coupling angle or load angle of synchronous motor is defined as the angle between the rotor and the stator poles of opposite polarity.

Description : The synchronous motor will develop maximum power when the load angle is?

Last Answer : The synchronous motor will develop maximum power when the load angle is 900.

Description : The 'Equal area criterion' for the determination of transient stability of a synchronous machine connected to an infinite bus  (1) ignores line as well as synchronous machine resistance ... consideration the possibility of machine losing synchronism after it has survived during the first swing.

Last Answer : 1

Description : During a disturbance on a synchronous machine, the rotor swings form A to B before finally setting down to steady state at point C on the power angle curve. The speed of the machine during oscillation is synchronous at point(s)

Last Answer : During a disturbance on a synchronous machine, the rotor swings form A to B before finally setting down to steady state at point C on the power angle curve. The speed of the machine during oscillation is synchronous at point(s) only at C

Last Answer : Synchronsizing power of a synchronous machine is inversely proportional to the synchronous reactance.

Last Answer : A synchronous machine with low value of short-circuit ratio has lower stability limit.

Description : If we change the excitation of synchronous machine will it affect on power factor?

Last Answer : Yes, If we change the excitation of synchronous machine it will affect on power factor. If the synchronous motor is overexcited then it will have leading power factor and if the motor is underexcited then it will have lagging power factor.

Description : If we change the excitation of synchronous machine will it affect on motor speed?

Last Answer : No, If we change the excitation of synchronous machine it will not affect on motor speed.

Description : V - curve of synchronous machine shows the relation between?

Last Answer : V - curve of synchronous machine shows the relation between AC armature current and DC field current.

Description : Why synchronous machine is called doubly excited machine?

Last Answer : Armature windings of synchronous machines either deliver 3 phase AC or absorb 3 phase AC source,  whereas field windings are energized from DC source. Thus due to presence of AC on armature and DC on field windings, synchronous machines are often referred as doubly excited machines.

Description : Which machine is the exciter of synchronous machine?

Last Answer : DC shunt machine is the exciter of synchronous machine.

Description : In a double squirrel cage induction motor, good starting torque is produced as (A) Large current flows through the outer high resistance winding. (B) Large current flows through the inner high ... the outer high resistance winding. (D) Large current flows through the inner low resistance winding.

Last Answer : In a double squirrel cage induction motor, good starting torque is produced as Large current flows through the outer high resistance winding.

Description : Torque developed by a three-phase, 400V, induction motor is 100 N -m. If the applied voltage is reduced to 200-V, the d'veloped torque will be

Last Answer : Torque developed by a three-phase, 400V, induction motor is 100 N -m. If the applied voltage is reduced to 200-V, the d'veloped torque will be 25 N -m

Description : The torque developed by any 3-phase induction motor at 0.8 p.u. slip is (A) Full-load torque (B) unstable torque (C) starting torque (D) break down

Last Answer : The torque developed by any 3-phase induction motor at 0.8 p.u. slip is unstable torque

Last Answer : The armature torque of the D.C. shunt motor is proportional to armature current.

Last Answer : Buses, trains, trolleys, hoists, cranes require high starting torque and therefore make use of D.C. series motor.

Last Answer : For the same H.P. rating and full load speed, following motor has poor starting torque differentially compounded.

Last Answer : The ratio of starting torque to full-load torque is least in case of shunt motors.

Last Answer : Speed torque characteristic of a repulsion induction motor is similar to that of a D.C. compound motor.

Last Answer : In repulsion motor, maximum torque is developed when brush axis is at 45° electrical to the field axis.

Last Answer : Capacitor start motor has high torque in starting

Description : Damper winding in a synchronous motor

Last Answer : Damper winding in a synchronous motor Serves to start the motor.

Description : Damper winding is provided in 3 phase synchronous motors to :

Last Answer : Damper winding is provided in 3 phase synchronous motors to : provide starting torque and prevent hunting

Description : In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load  (A) The armature current increases and the power factor decreases  (B) The armature ... but is lagging  (D) The armature current decreases and the power factor increases and is leading

Last Answer : In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load The armature current decreases and the power factor increases and is leading

Description : In a synchronous generator delivering lagging power factor load  (1) the excitation emf leads terminal voltage by the power angle (2) the excitation emf lags terminal voltage by the power angle (3) ... by the power factor angle (4) excitation emf lags the terminal voltage by the power factor angle

Last Answer : In a synchronous generator delivering lagging power factor load the excitation emf leads terminal voltage by the power angle

Description : Two synchronous generators operating in parallel supply a common load of 2.5 MW. The frequency-power characteristics have a common slope of 1 MW/Hz and the no-load frequencies of the generators are 51.5 Hz and 51.0 Hz, ... system frequency is (A) 50 Hz (B) 51 Hz (C) 51.25 Hz (D) 51.5 Hz

Last Answer : Two synchronous generators operating in parallel supply a common load of 2.5 MW. The frequency-power characteristics have a common slope of 1 MW/Hz and the no-load frequencies of the generators are 51.5 Hz and 51.0 Hz, respectively. Then the system frequency is 50 Hz

Description : The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is (A) 0.25 pu (B) 0.5 pu (C) 1.0 pu (D) 1.5 pu

Last Answer : The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is 0.5 pu

Description : The armature reaction in a synchronous generator supplying leading power factor load is (A) magnetizing (B) demagnetizing (C) demagnetizing and cross-magnetizing (D) magnetizing and cross-magnetizing

Last Answer : The armature reaction in a synchronous generator supplying leading power factor load is magnetizing and cross-magnetizing

Description : The effect of increasing load on a synchronous motor running with normal excitation is (A) Increase both its Ia and power factor. (B) Decrease Ia, but increase power factor. (C) Increase Ia, but decrease power factor (D) Decrease both Ia and power factor.

Last Answer : The effect of increasing load on a synchronous motor running with normal excitation is Increase Ia, but decrease power factor

Description : A three-phase synchronous motor connected to ac mains is running at full load and unity power factor. lf its shaft load is reduced by half and field current is held constant then its new power factor will be

Last Answer : Leading

Last Answer : In case of a reluctance motor, when the load is increased so that it cannot maintain synchronous speed the motor will run as induction motor.

Last Answer : Centrifugal switch disconnects the auxiliary winding of the motor at about 70 to 80 percent of synchronous speed.

Last Answer : If the centrifugal switch does not open at 70 to 80 percent of synchronous speed of motor, it would result in damage to the starting winding.

Description : What is the difference between synchronous and asynchronous motors?

Last Answer : The motor which rotates at constant speed is called synchronous motor. And that constant speed is called as synchronous speed.  And the motor which does not rotates at constant speed are called asynchronous motor. Asynchronous motor is also called as Induction motor.

Last Answer : Yes, we can make the power factor of synchronous motor leading by adjusting its excitation.

Description : In synchronous motor, does the winding losses vary with load?

Last Answer : No, in the synchronous motor the winding losses do not vary with load.

Description : what is the difference between synchronous and asynchronous motor?

Last Answer : Asynchronous motors and syncrouns motor are called as dc machines.  and also syncrouns motor called as induction motor. Asynonymous motor as are rotates with constant speed we not able to operate . ... It is able to operate. These are a small difference between syncrouns and asynchronous motors. 

Description : UNIT 1 fundamentals of AC rotating machine Contents 1.1 Introduction 1.2 Advantages 1.3 Parts of AC machines 1.4 Synchronous speed 1.5 AC winding 1.6 Winding factor ( ... alternator or generator 1.9 Numericals 1.10 Harmonic 1.11 Slot harmonics 1.12 Harmonics minimization

Last Answer : 1.2 Advantages: In practices most of alternator have rotating magnetic field type construction with stationary armature due to following reason. The generation level of AC voltage may be in the range ... at high speed. Only two Slip rings are required to excited the field by AC supply.

Description : A 200 V DC machine supplies 20 A at 200 V as a generator. The armature resistance is 0.2 Ohm. If the machine is now operated as a motor at same terminal voltage and current but with the flux increased by 10%, the ratio of motor speed to generator speed is

Last Answer : A 200 V DC machine supplies 20 A at 200 V as a generator. The armature resistance is 0.2 Ohm. If the machine is now operated as a motor at same terminal voltage and current but with the flux increased by 10%, the ratio of motor speed to generator speed is 0.87

Description : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively

Last Answer : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively 19,17

Description : The induced emf in the armature of a lap -wound four -pole dc machine having 100 armature conductors rotating at 600 rpm and with 1 Wb flux per pole is  (1) 1000V (2) 100V (3) 600V (4) 10,000V

Last Answer : The induced emf in the armature of a lap -wound four -pole dc machine having 100 armature conductors rotating at 600 rpm and with 1 Wb flux per pole is 1000V

Description : Aluminium is not used as winding wire for the armature of a dc machine because  (1) aluminium has low resistivity (2) a large winding space is taken by aluminium conductors and creates ... ) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper

Last Answer : Aluminium is not used as winding wire for the armature of a dc machine because  (2) a large winding space is taken by aluminium conductors and creates jointing problems (3) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper

Description : In a dc machine, interpoles are used to  (1) neutralize the effect of armature reaction in the interpolar region (2) generate more induced emf in the armature (3) avoid interference of the armature flux with the main -field flux (4) reduce the demagnetizing effect of armature reaction

Last Answer : In a dc machine, interpoles are used to neutralize the effect of armature reaction in the interpolar region

Description : Brushes of DC machine are made up of ?

Last Answer : Brushes of DC machine are made up of carbon.