The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ

(A) directly proportional to α and Φ

(B) inversely proportional to α and Φ

(C) directly proportional to α and inversely proportional to Φ

(D) directly proportional to Φ and inversely proportional to α

1 Answer

Answer :

The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ directly proportional to α and inversely proportional to Φ

Related questions

Description : In a 230 V, 50 Hz single-phase SCR bridge converter operating at a firing delay angle, α and with large R-L load, the input source current is (A) sinusoidal current (B) constant dc current (C) continuous rectangular pulses (D) alternating rectangular pulses

Last Answer : In a 230 V, 50 Hz single-phase SCR bridge converter operating at a firing delay angle, α and with large R-L load, the input source current is alternating rectangular pulses

Description : A separately excited dc motor operating in first quadrant is fed from 3-phase semi -converter free -wheeling diode is open circuited, then the motor :  (A) can be operated in first quadrant (B) ... in first & second quadrants (C) can be operated in first & fourth quadrants (D) cannot be operated

Last Answer : A separately excited dc motor operating in first quadrant is fed from 3-phase semi -converter free -wheeling diode is open circuited, then the motor : can be operated in first & fourth quadrants

Description : A 230 V, 50 Hz phase controlled single-phase full-controlled SCR bridge converter draws 15 A constant dc current. If the source inductance is 3 mH, the drop in dc output voltage is (A) 4.5 V (B) 6.75 V (C) 9 V (D) 13.5 V

Last Answer : A 230 V, 50 Hz phase controlled single-phase full-controlled SCR bridge converter draws 15 A constant dc current. If the source inductance is 3 mH, the drop in dc output voltage is 9 V

Description : Separately Excited DC motor

Last Answer : Separately Excited DC motor

Last Answer : In a separately excited generator supplying rated load the armature reaction is always present.

Description : In a single-phase induction motor, the operating direction is determined by the ________ A) Rotor B) Stator C) Starting circuit D) None of these

Last Answer : In a single-phase induction motor, the operating direction is determined by the Starting circuit

Description : The direction of rotation of an inverter fed 3-phase ac motor is reversed by (A) a mechanical reversing switch (B) reversing the input dc link voltage (C) operating the inverter as a rectifier (D) changing the sequence of switching

Last Answer : The direction of rotation of an inverter fed 3-phase ac motor is reversed by changing the sequence of switching

Description : Give the operation of single phase full wave bridge controlled converter with RL load with a neat diagram. Also draw its waveform.

Last Answer : Single phase fully control bridge converter with RL load: 1. During positive half cycle of input voltage, T1 and T2 are forward biased and during negative half cycle, T3 and T4 are forward biased. Therefore, T1-T2 ... cycle till the firing of next pair of SCRs as shown in the waveform.

Description : In a 3-phase converter circuit during commutation when one SCR in one phase is turned on to turn-off an SCR in another phase, results in (A) voltage notching (B) harmonic distortion (C) voltage sag (D) voltage swell

Last Answer : In a 3-phase converter circuit during commutation when one SCR in one phase is turned on to turn-off an SCR in another phase, results in voltage notching

Last Answer : The operating speed of a synchronous motor can be changed to new fixed value by changing frequency.

Description : Why does the speed of a DC shunt motor decrease as the load increases?

Last Answer : Because if the load is increasing then the torque must also be increase. If not then the speed of motor will decrease.

Description : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be

Last Answer : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be 474 V

Description : Draw circuit diagram of symmetrical configuration of bridge converter.

Last Answer : circuit diagram of symmetrical configuration of bridge converter

Description : Explain the operation of full bridge converters with their different operating modes. State its advantages and disadvantages.

Last Answer : Full bridge converter: Full bridge converter provides isolation between input and output. Full bridge converter is used for step up or step down the input voltage. Full bridge converter consists of four power semiconductor ... Require filter on both input and output.

Description : A 230 V/460 V single-phase transformer operating at 20 A and unity power factor has primary referred resistance of 0.2 Ω and reactance of 0.5 Ω. The approximate primary induced emf is (A) 216 V (B) 226 V (C) 234 V (D) 236 V

Last Answer : A 230 V/460 V single-phase transformer operating at 20 A and unity power factor has primary referred resistance of 0.2 Ω and reactance of 0.5 Ω. The approximate primary induced emf is 226 V

Description : A 3 -phase, fully controlled, converter is feeding power into a DC load at a constant current of 150 A, the rms value of the current flowing through each thyristor of the converter is

Last Answer : Please show the solution for this question

Description : What are the speed control methods of dc motor?

Last Answer : Field control of DC motor Armature control of DC motor

Description : If the load of the normally excited synchronous motor is increased the power factor will?

Last Answer : If the load of the normally excited synchronous motor is increased the power factor will become lagging.

Last Answer : As the load is increased the speed of D.C. shunt motor will reduce slightly.

Last Answer : Series motor should not be started on no-load.

Last Answer : An over excited synchronous motor on noload is known as synchronous condenser.

Description : If the field of synchronous motor is under excited, power factor will be?

Last Answer : If the field of synchronous motor is under excited, power factor will be lagging.

Last Answer : If the speed of a D.C. shunt motor is increased, the back e.m.f. of the motor will increase.

Description : The speed of a D.C. motor can be controlled by varying  1. Its flux per pole 2. Resistance of armature circuit 3. Applied voltage 4. All of the above

Last Answer : The speed of a D.C. motor can be controlled by varying  1. Its flux per pole 2. Resistance of armature circuit 3. Applied voltage 4. All of the above

Last Answer : The speed of a D.C. shunt motor can be increased by increasing the resistance in field circuit.

Last Answer : The speed of a D.C. series motor is inversely proportional to the armature current.

Last Answer : In a D.C. shunt motor, speed is independent of armature current.

Description : Chopper controlled DC motor

Last Answer : Chopper controlled DC motor

Description : In a single-phase induction motor when the rotor is stationary and voltage is applied to the stator, then (A) the flux is constant (B) the flux first decreases and then increases in ... increases and decreases in the opposite direction with the same magnitude (D) current flows through the rotor

Last Answer : In a single-phase induction motor when the rotor is stationary and voltage is applied to the stator, then the flux first decreases and then increases in the same direction

Last Answer : The starting winding of a single-phase motor is placed in stator.

Last Answer : If starting winding of a single-phase induction motor is left in the circuit, it will draw excessive current and overheat.

Last Answer : A single-phase induction motor is inherently non-self-starting with low torque.

Last Answer : The power factor of a single-phase induction motor is usually lagging.

Last Answer : In a capacitor start single-phase motor, when capacitor is replaced by a resistance motor will continue to run in same direction.

Last Answer : In a shaded pole single-phase motor, the revolving field is produced by the use of shading coils.

Last Answer : The rotor developed by a single-phase motor at starting is zero.

Last Answer : If the capacitor of a single-phase motor is short-circuited the motor will not start.

Last Answer : The relay operating speed depends upon the spring tension, the rate of flux built up, armature core air gap.

Description : The fall in speed of a dc generator due to increase in load can be corrected by  (1) cooling the armature.. (2) increasing the excitation. (3) reducing the load voltage. (4) increasing the input to the prime mover

Last Answer : It   can  be  corrected  by  increasing  the  input  to  the  prime  mover.

Description : A separately excited d.c. motor fed from single phase full converter with firing angle 60° runs at 1000 r.p.m. If motor is connected to single phase semiconverter with the same firing angle of 60°, it would run at (a) 2000 rpm (b) 1850 rpm (c) 1500 rpm (d) 1000 rpm 

Last Answer : Ans =1500

Description : In a 2 kW, 200 V, 1000 rpm. DC series motor the torque at full load was found to be 0.3 N -m. The torque at half full load in N -m is :

Last Answer : In a 2 kW, 200 V, 1000 rpm. DC series motor the torque at full load was found to be 0.3 N -m. The torque at half full load in N -m is : 0.075

Last Answer : For the same H.P. rating and full load speed, following motor has poor starting torque differentially compounded.

Last Answer : In case of a reluctance motor, when the load is increased so that it cannot maintain synchronous speed the motor will run as induction motor.

Last Answer : The speed/load characteristics of a universal motor is same as that of D.C. series motor.

Description : The speed of a three-phase induction motor is controlled by variable voltage variable frequency control (i.e. keeping V/f constant). As the frequency is reduced, the slip at maximum torque  (1) Decreases (2) Increases (3) Remains constant (4) None of the above

Last Answer : The speed of a three-phase induction motor is controlled by variable voltage variable frequency control (i.e. keeping V/f constant). As the frequency is reduced, the slip at maximum torque Increases 

Description : The speed of a 2-pole, 3-phase stepper motor operated by 1200 pulses/min (A) 100 rpm (B) 200 rpm (C) 400 rpm (D) 800 rpm

Last Answer : The speed of a 2-pole, 3-phase stepper motor operated by 1200 pulses/min 200 rpm

Description : speed control methods of three phase induction motor?

Last Answer : Speed control of three phase induction motor

Description : If field current is decreased in shunt dc motor, the speed of the motor (a) remains same. (b) increases. (c) decreases. (d) none of the above.

Last Answer : increases

Description : With a neat diagram explain doubly fed induction generator (DFIG). 

Last Answer : Diagram of Doubly fed induction generator (DFIG):  Explanation :-  DFIG can feed power through the stator as well as rotor to the grid. The stator is directly connected to the fixed frequency ... voltage is 690 V AC. So it must be step up to 33 KV to connect to power grid.  

Last Answer : The speed of a D.C. shunt motor more than its full-load speed can be obtained by decreasing the field current.