For a 500 Hz frequency excitation, a 50 km long power line will be modeled as

1 Answer

Answer :

For a 500 Hz frequency excitation, a 50 km long power line will be modeled as long line

Related questions

Last Answer : Impedance relays are used for phase faults on long line.

Description : what is mean by long transmission line ?

Last Answer : The transmission line which have length more than 250 km are known as long transmission lines.

Description : If we change the excitation of synchronous machine will it affect on power factor?

Last Answer : Yes, If we change the excitation of synchronous machine it will affect on power factor. If the synchronous motor is overexcited then it will have leading power factor and if the motor is underexcited then it will have lagging power factor.

Last Answer : Yes, we can make the power factor of synchronous motor leading by adjusting its excitation.

Description : What would happen if a power transformer designed for operation on 50 Hz (frequency) were connected to a 500 Hz (frequency) source of the same voltage:  (A) Eddy Current and Hysteresis losses will be ... Current will be too much high  (C) Transformer may start to smoke and burn  (D) No effect

Last Answer : What would happen if a power transformer designed for operation on 50 Hz (frequency) were connected to a 500 Hz (frequency) source of the same voltage:  (A) Eddy Current and Hysteresis losses will be ... will be too much high  (C) Transformer may start to smoke and burn  (D) No effect

Description : Why is AC better for long distance power transmission than DC ?

Last Answer : ac is more economical to transmit for long distances . wires can be made smaller by step up transformer .. since major cost are wires to transmit .. then at the end of distance step down transformer is used for commercial use.

Last Answer : Power for lighting in passanger coach, in a long distance electric train, is provided through individual generator of bogie and batteries.

Description : Classify the transformers based on the construction, frequency and power.

Last Answer : Classification of Transformer Based On: i) Construction: Shell type, Core type, Berry type ii) Change in voltage level: Step-Up, Step-Down, iii) Number of phases: Single phase, Three phase iv) ... Control vi) Cooling: Self-cooled, Air-cooled, Forced-air cooled, Oil-cooled, Forced-oil cooled. 

Description : The device which allows reverse power flow and withstands highest switch frequency is (A) GTO (B) MOSFET (C) IGBT (D) Inverter grade SCR

Last Answer : The device which allows reverse power flow and withstands highest switch frequency is MOSFET

Description : The time period of third harmonic of power supply frequency, in milliseconds, is (A) 20 (B) 3.33 (C) 6.66 (D) 60

Last Answer : The time period of third harmonic of power supply frequency, in milliseconds, is 6.66 

Description : Two waves have frequency of 500 Hz. One is set at its maximum value whereas the other at zero. The phase angle between them will be

Last Answer : Two waves have frequency of 500 Hz. One is set at its maximum value whereas the other at zero. The phase angle between them will be 90o

Description : Is the power line voltage available in our homes a dc or an ac voltage?

Last Answer : The power line voltage available in our homes is AC. Mobile dwellings are the most commonly DC-supplied homes and even then they tend to include AC supply for heavier loads.

Description : A lightening arrester connected between the line and earth in a power system  (1) protects the terminal equipment against travelling surges (2) protects the transmission line against direct ... suppresses high frequency oscillations in the line (4) reflects back the travelling wave approaching it

Last Answer : A lightening arrester connected between the line and earth in a power system protects the terminal equipment against travelling surges

Description : The reactive power transfer over a line mainly depends on

Last Answer : The reactive power transfer over a line mainly depends on lVsl- lVRl

Description : Pure inductive circuit takes power from the A.C. line when?

Last Answer : It takes power when voltage decreases and current increases.

Last Answer : The inductive interference between power and communication line can be minimized by transposition of the power line, transposition of the communication line.

Description : What is a high tension power line?

Last Answer : High tension power line is a high voltage of 115 kv and power line is underground transimissio used by urbun areas

Description : In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load  (A) The armature current increases and the power factor decreases  (B) The armature ... but is lagging  (D) The armature current decreases and the power factor increases and is leading

Last Answer : In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load The armature current decreases and the power factor increases and is leading

Description : The effect of increasing load on a synchronous motor running with normal excitation is (A) Increase both its Ia and power factor. (B) Decrease Ia, but increase power factor. (C) Increase Ia, but decrease power factor (D) Decrease both Ia and power factor.

Last Answer : The effect of increasing load on a synchronous motor running with normal excitation is Increase Ia, but decrease power factor

Description : While keeping the excitation constant, if the steam supply of an alternator running in parallel with another identical alternator is increased, then (A) It would over-run the other alternator (B) Its rotor ... (C) Its portion of share in load will increase (D) Its power factor would be decreased.

Last Answer : While keeping the excitation constant, if the steam supply of an alternator running in parallel with another identical alternator is increased, then Its portion of share in load will increase

Last Answer : For a D.C. shunt motor if the excitation is changed torque will change but power will remain constant.

Last Answer : A synchronous motor running with normal excitation adjusts to load increases essentially by increase in armature current.

Description : If we change the excitation of synchronous machine will it affect on motor speed?

Last Answer : No, If we change the excitation of synchronous machine it will not affect on motor speed.

Description : what will happen when excitation of an unloaded salient pole synchronous motor suddenly gets disconnected?

Last Answer : When excitation of an unloaded salient pole synchronous motor suddenly gets disconnected the motor will stop.

Last Answer :  A sine wave has a frequency of 50 Hz. Its angular frequency is 100 n radian/second.

Description : In a self-controlled synchronous motor fed from a variable frequency inverter  (1) the rotor poles invariably have damper windings  (2) there are stability problems  (3) the speed of the rotor decides stator frequency  (4) the frequency of the stator decides the rotor speed

Last Answer : 2

Description : A series R-L-C Circuit has a resonant frequency of 1000 Hz. If the values of R, L and C are doubled, the new resonant frequency is

Last Answer : A series R-L-C Circuit has a resonant frequency of 1000 Hz. If the values of R, L and C are doubled, the new resonant frequency is 500 Hz

Description : An accelerometer has input range of 0 to 10g, natural frequency 30 Hz and mass 0.001 kg. The range of the secondary displacement transducer in mm required to cover the input range is (A) 0 to 2.76 (B) 0 to 9.81 (C) 0 to 11.20 (D) 0 to 52.10

Last Answer : An accelerometer has input range of 0 to 10g, natural frequency 30 Hz and mass 0.001 kg. The range of the secondary displacement transducer in mm required to cover the input range is 0 to 2.76

Description : For a frequency of 200 Hz, the time period will be?

Last Answer : For a frequency of 200 Hz, the time period will be 0.005 s.

Description : Shunt compensation in an EHV line is used to (A) Improve stability. (B) Improve the voltage profile. (C) Reduce the fault level. (D) Substitute for synchronous phase modifier.

Last Answer : Shunt compensation in an EHV line is used to Improve the voltage profile.

Description : If an unsymmetrical line to ground fault occurs at the secondary terminals of a delta/star, ungrounded transformer, then  (A) zero sequence currents are present on both sides of the transformer  (B) ... side  (D) zero sequence currents are present on the primary side but not on the secondary side

Last Answer : If an unsymmetrical line to ground fault occurs at the secondary terminals of a delta/star, ungrounded transformer, then zero sequence currents are absent on both sides of the transformer 

Description : Series capacitive compensation in EHV transmission line is used to

Last Answer : To maintain voltage stability 

Description : The sending end and receiving end voltages of a three-phase transmission line are 10 kV/ph and 9.5 kV/ph, respectively. If the resistance drop is 150 V/ph and receiving end power factor is 0.8, the sending end power factor is (A) 0.745 lagging (B) 0.775 lagging (C) 0.8 lagging (D) 0.85 lagging

Last Answer : Vscos¢s-Vrcos¢r=IR

Description : Draw a neat sketch and explain the accessory used to support long work.

Last Answer : Accessory to support long work: A steady rest is a tool for a lathe, enabling a machinist to make deep cuts in long, slender stock, bore out thin pieces of metal, and generally keeps thin stuff straight. ... tool that follows the cutter, a steady rest is firmly attached to the bed of a lathe.

Description : The standard for long distance analog signal transmission in process control industry is (A) 4-20 mV (B) 0-20 mA (C) 4-20 mA (D) 0-5 V

Last Answer : The standard for long distance analog signal transmission in process control industry is 4-20 mA

Last Answer : A cumulatively compounded long shunt generator when operating as a motor would be differentially compounded long shunt.

Description : For 11kV line the inductance per km per phase will be of the order of:  (A) 1 H (B) 0.1 H (C) 1 mH (D) 0.1 mH

Last Answer : For 11kV line the inductance per km per phase will be of the order of: 1 mH

Description : A transmission line of 200 km has a certain A, B, C and D parameters. If the length is reduced to 60 km

Last Answer : A transmission line of 200 km has a certain A, B, C and D parameters. If the length is reduced to 60 km A increases, B decreases

Description : The corona loss in a 50 Hz system is 0.25 kW/ph/km. At a frequency of 60 Hz, the corona loss would be   (a) 0.30 kW/ph/km (b) 0.36 kW/ph/km (c) 028 kW/ph/km (d) 0.21 kW/ph/km

Last Answer : The corona loss in a 50 Hz system is 0.25 kW/ph/km. At a frequency of 60 Hz, the corona loss would be 028 kW/ph/km

Description : Operating frequency of power MOSFET is higher than that of power BJT. Justify the statement.

Last Answer : Power MOSFET have high turning on and turning off capability high switching speed of MOSFET is due to the high rate of change of drain voltage. The switching losses of power MOSFET ... lower frequency. Hence, operating frequency of power MOSFET is higher than that of power BJT.

Description : A 50 Hz, 4-pole, 500 MVA, 22 kV turbo-generator is delivering rated megavolt amperes at 0.8 power factor. Suddenly a fault occurs reducing in electric power output by 40%. Neglect losses and assume constant power input to the ... the time of fault will be  (A) 1.528 (B) 1.018 (C) 0.848 (D) 0.509

Last Answer : A 50 Hz, 4-pole, 500 MVA, 22 kV turbo-generator is delivering rated megavolt amperes at 0.8 power factor. Suddenly a fault occurs reducing in electric power output by 40%. Neglect losses and assume ... the shaft. The accelerating torque in the generator in MNm at the time of fault will be 1.018 

Description : Sinusoids find amplitude, period, frequency, voltage (Problem 1)

Last Answer : Sinusoids find amplitude, period, frequency, voltage (Problem 1)

Description : Principal of digital frequency meter.

Last Answer : The basic block diagram of basic digital frequency meter (DFM) is shown in above figure. The signal whose frequency we have to be measured is first to be amplified through amplifier. The output of amplifier ... = Number of counts. t = Time interval between start and stop condition of the gate.

Description : Define the following terms: 1) Virtual height 2) Actual height 3) Critical frequency. 4) Maximum usable frequency.

Last Answer : 1) Virtual height:- The incident and refracted rays follow paths that are exactly the same as they have been if reflection had taken place from a surface located at a greater height, called ... angle of incidence is other than the normal is known as maximum unstable frequency. MUF= fc secθ 

Description : Draw the diagram and explain the working of ferrodynamic type frequency meter. 

Last Answer : Ferrodynamic type frequency meter: (Electrical resonance type frequency meter): It consists of a fixed coil. The supply whose frequency is to be measured is connected across it. This coil ... so selected that the moving coil takes up a convenient position when frequency is of normal value. 

Description : List the different types of frequency meters.

Last Answer : Different types of frequency meters  1. Reed type [Mechanical type] 2. Ferro-dynamic type [Resonances type] 3. Weston type 4. Ratio-meter type 5. Saturable core type 6. Digital type

Description : Explain working of Weston type frequency meter.

Last Answer : Weston Type Frequency Meter: There are two fixed coils marked as A and B. Each coil divided into two equal parts and are fixed such that their magnetic axis are perpendicular to each ... leading to deflections in either direction depending on the currents there in, due to changed impedances.

Description : State the application of phase sequence indicator; clip on ammeter, frequency meter & P.F. meter.

Last Answer : Phase Sequence Indicator:  1. For finding correct phase sequence of supply  2. For obtaining exact instant of parallel operation of alternators.  3. For obtaining reversal of rotation ...  4. In electroplating industries   5. In various processes industries for measuring power factor

Description : List two types of oscillator, which generates frequency in RF range.

Last Answer : Types of Oscillators generating frequencies in RF range: i) Hartley Oscillator ii) Colpitt’s Oscillator iii) Clapp Oscillator

Description : State the need of multistage amplifier. Draw frequency response of R-C coupled amplifier.

Last Answer : The need of multistage amplifier The voltage (or power) gain, obtained from a single stage small signal amplifier, is limited. Therefore, it is not sufficient for all practical applications. Therefore, in ... to use a MULTISTAGE AMPLIFIER .  Frequency response of R-C coupled amplifier.