In a DC generator the windings of interpoles are connected : 

(A) in series with main field winding, to create a pole,of same polarity as the main pole ahead in the direction of rotation. 

(B) in series with main field winding, to create a pole of opposite polarity as the main pole ahead in the direction of rotation. 

(C) in series with the armature winding, to create a pole of same polarity as the main pole ahead in the direction of rotation. 

(D) in series with the armature winding, to create a pole of opposite polarity as the main pole ahead in the direction of rotation.

1 Answer

Answer :

In a DC generator the windings of interpoles are connected :  in series with the armature winding, to create a pole of same polarity as the main pole ahead in the direction of rotation. 

Related questions

Description : In dc machines, the armature windings are placed on the rotor because of the necessity for  (1) electromechanical energy conversion (2) generation of voltage (3) commutation (4) development of torque

Last Answer : 3  Commutation

Last Answer : In D.C. generators the polarity of the interpoles is the same as that of the main pole ahead.

Last Answer : Compensating windings are used in D.C. generators to neutralise the cross-magnetising effect of the armature reaction.

Description : A 200 V DC machine supplies 20 A at 200 V as a generator. The armature resistance is 0.2 Ohm. If the machine is now operated as a motor at same terminal voltage and current but with the flux increased by 10%, the ratio of motor speed to generator speed is

Last Answer : A 200 V DC machine supplies 20 A at 200 V as a generator. The armature resistance is 0.2 Ohm. If the machine is now operated as a motor at same terminal voltage and current but with the flux increased by 10%, the ratio of motor speed to generator speed is 0.87

Description : The fall in speed of a dc generator due to increase in load can be corrected by  (1) cooling the armature.. (2) increasing the excitation. (3) reducing the load voltage. (4) increasing the input to the prime mover

Last Answer : It   can  be  corrected  by  increasing  the  input  to  the  prime  mover.

Description : What is the difference between an AC and DC generator?

Last Answer : The generator which generates DC voltage is called DC generator and generator which generates AC voltage is called AC generator (or) Alternator. In DC generator armature is rotated and field winding ... generator. A DC generator can generate low voltages but an AC generator can generate upto 11kv.

Description : What is the principle of DC generator?

Last Answer : principle

Description : From which material field coils of DC generator are made of?

Last Answer : Field coils of DC generator are usually made of copper.

Description : Why is the armature of DC generator laminated?

Last Answer : The armature of DC generator is laminated to reduce eddy current losses.

Description : State the function of commutator in DC generator and name the material used for commutator.

Last Answer : Function of Commutator: Commutator converts AC induced in armature winding into DC for external load. Material: i) Commutator segments are made up of Copper. ii) Commutator segments are insulated from each other by Mica.

Description : The eddy current loss in a dc generator is 400 W at 40 Hz frequency of reversal and constant flux density. When frequency is increased to 50 Hz., eddy current loss is :  (A) 256 W (B) 320 W (C) 500 W (D) 625 W

Last Answer : The eddy current loss in a dc generator is 400 W at 40 Hz frequency of reversal and constant flux density. When frequency is increased to 50 Hz., eddy current loss is : 625 W

Description : The terminal characteristics of a dc generator suitable for electric welders is (A) separately excited generator (B) shunt generator (C) series generator (D) differentially compounded generator

Last Answer : The terminal characteristics of a dc generator suitable for electric welders is differentially compounded generator

Description : In a dc machine, interpoles are used to  (1) neutralize the effect of armature reaction in the interpolar region (2) generate more induced emf in the armature (3) avoid interference of the armature flux with the main -field flux (4) reduce the demagnetizing effect of armature reaction

Last Answer : In a dc machine, interpoles are used to neutralize the effect of armature reaction in the interpolar region

Last Answer : The critical resistance of the D.C. generator is the resistance of field.

Description : If residual magnetism is present in a D.C. generator, the induced e.m.f. at zero speed will be?

Last Answer : If residual magnetism is present in a D.C. generator, the induced e.m.f. at zero speed will be zero.

Last Answer : A 220 V D.C. generator is run at full speed without any excitation. The open circuit voltage will be about 2 V.

Last Answer : In a level compounded D.C. generator, full load terminal voltage is equal to no-load terminal voltage.

Last Answer : In a D.C. generator in case the resistance of the field winding is increased, then output voltage will decrease.

Last Answer : A D.C. generator can be considered as rotating amplifier.

Last Answer : In a D.C. generator, the critical resistance refers to the resistance of field.

Last Answer : Flashing the field of D.C. generator means creating residual magnetism by a D.C. source.

Last Answer : If a D.C. generator fails to build up the probable cause could not be field resistance less than the critical resistance.

Last Answer : In a D.C. generator the magnetic neutral axis coincides with the geometrical neutral axis, when there is no load on|he generator.

Last Answer : The e.m.f. generated in a D.C. generator is directly proportional to speed of armature.

Last Answer : In a D.C. generator the number of mechanical degrees and electrical degrees will be the same when number of poles is 2.

Last Answer : D.C. generator generally preferred for charging automobile batteries is long shunt compound generator.

Last Answer : The armature core of a D.C. generator is usually made of silicon steel.

Last Answer : In a D.C. generator the ripples in the direct e.m.f. generated are reduced by using carbon brushes of superior quality.

Last Answer : The demagnetising component of armature reaction in a D.C. generator reduces generator e.m.f.

Last Answer : If brushes of a D.C. generator are moved in order to bring these brushes in magnetic neutral axis, there will be crossmagnetisation as well as demagnetising.

Last Answer : In case of a 4-pole D.C. generator provided with a two layer lap winding with sixteen coils, the pole pitch will be 8.

Description : For a D.C. generator when the number of poles and the number of armature conductors is fixed, then which winding will give the higher e.m.f. ?

Last Answer : Wave winding

Last Answer : In a D.C. generator, the iron losses mainly take place in armature rotor.

Last Answer : The condition for maximum efficiency for a D.C. generator is variable losses equal to constant losses.

Last Answer : The total losses in a well designed D.C. generator of 10 kW will be nearly 500 W.

Last Answer : Burning out of windings is due to short circuited capacitor.

Last Answer : In D.C. generators on no-load, the air gap flux distribution in space is flat topped.

Description : A _________ is used to measure the stator % winding temperature of the generator.  (A) Thermocouple (B) Pyrometer (C) Resistance thermometer (D) Thermometer

Last Answer : A Resistance thermometer is used to measure the stator % winding temperature of the generator. 

Description : In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load  (A) The armature current increases and the power factor decreases  (B) The armature ... but is lagging  (D) The armature current decreases and the power factor increases and is leading

Last Answer : In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load The armature current decreases and the power factor increases and is leading

Description : In a synchronous generator delivering lagging power factor load  (1) the excitation emf leads terminal voltage by the power angle (2) the excitation emf lags terminal voltage by the power angle (3) ... by the power factor angle (4) excitation emf lags the terminal voltage by the power factor angle

Last Answer : In a synchronous generator delivering lagging power factor load the excitation emf leads terminal voltage by the power angle

Description : The armature reaction in a synchronous generator supplying leading power factor load is (A) magnetizing (B) demagnetizing (C) demagnetizing and cross-magnetizing (D) magnetizing and cross-magnetizing

Last Answer : The armature reaction in a synchronous generator supplying leading power factor load is magnetizing and cross-magnetizing

Description : What are the main parts of a generator?

Last Answer : the main parts of the generator are as follows yoke Armature Poles field winding Prime mover  Commutator Shaft Bearings Brushes

Last Answer : if induction motor rotates exceed than its synchronous speed, it acts as a generator.

Description : Describe the reason of using dc series motor for electric trains.

Last Answer : Electric trains require an inverse torque speed characteristics for proper operation. That is a higher torque is required at start (when speed is nil or low) and as the train picks up ... torque - speed characteristics of DC series motors match, these motors are suitable for electric trains

Description : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be

Last Answer : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be 474 V

Description : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is

Last Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

Description : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively

Last Answer : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively 19,17

Description : Identify the increasing order of voltage regulation of the following dc generators a same load :  (A) differential compound, shunt and under compound  (B) shunt, differential compound and ... C) under compound, shunt and differential compound  (D) shunt, under compound and differential compound

Last Answer : Identify the increasing order of voltage regulation of the following dc generators a same load : under compound, shunt and differential compound 

Description : In a 2 kW, 200 V, 1000 rpm. DC series motor the torque at full load was found to be 0.3 N -m. The torque at half full load in N -m is :