If an unsymmetrical line to ground fault occurs at the secondary terminals of a delta/star, ungrounded transformer, then 

(A) zero sequence currents are present on both sides of the transformer 

(B) zero sequence currents are absent on both sides of the transformer 

(C) zero sequence currents are present on the secondary side but not on the primary side 

(D) zero sequence currents are present on the primary side but not on the secondary side

1 Answer

Answer :

If an unsymmetrical line to ground fault occurs at the secondary terminals of a delta/star, ungrounded transformer, then zero sequence currents are absent on both sides of the transformer 

Related questions

Description : Delta to Star Conversion Example

Last Answer : Delta to Star Conversion Example

Description : Wye (Star) to Delta Conversion

Last Answer : Wye (Star) to Delta Conversion

Description : Star to delta conversion examples

Last Answer : Star to delta conversion example 1

Description : Compare star and Delta Connection.

Last Answer : Compare Star and Delta connected system:  Star connected system Delta connected system   In STAR connection, the starting or finishing ends (Similar ends) of three coils are connected together to form the ... VPH Line Current is √3 times of Phase Current. i.e. IL = √3 IPH

Description : What is difference between Star and Delta Connection?

Last Answer : Star is        1. Open ckt       2. At center point present  neutral   Delta is     1.   Closed ckt 2.      Neutral not present in this case 

Last Answer : Reactance relay is preferred for phase fault on short transmission line.

Description : The line current in a balanced delta system is 30 A. The load current is (A) 30√3 A (B) 30/√3 A (C) 10 A (D) 30/√2 A

Last Answer : The line current in a balanced delta system is 30 A. The load current is 30/√3 A

Description : Write the relation between phase and line current, phase and line voltage for Star connection.

Last Answer : Line voltage is equal to root three times of phase voltage and line and phase currents are equal in star connection

Description : In the case of an unsymmetrical alternating current the average value must always be taken over?

Last Answer : In the case of an unsymmetrical alternating current the average value must always be taken over the whole cycle.

Description : To protect the power transformer (Y-Y with neutral grounded) against fault, what type of connection do the CTs have ?

Last Answer : To protect the power transformer (Y-Y with neutral grounded) against fault, what type of connection do the CTs have ? Δ-Δ connection

Last Answer : The inverse definite mean time relays are used for over current and earth fault protection of transformer against internal short-circuits.

Description : Increasing the number of turns of wire on the secondary of a transformer will  (A) Decrease the secondary current (B) Increase the primary current (C) Have no effect on the secondary current (D) Increase the secondary current

Last Answer : Increasing the number of turns of wire on the secondary of a transformer will Decrease the secondary current 

Description : A certain transformer has 200 turns in the primary winding, 50 turns in the secondary winding and 120 volts applied to the primary. What is the voltage across the secondary?  (A) 30 Volts (B) 480 Volts (C) 120 Volts (D) 60 Volts

Last Answer : A certain transformer has 200 turns in the primary winding, 50 turns in the secondary winding and 120 volts applied to the primary. What is the voltage across the secondary?  (A) 30 Volts (B) 480 Volts (C) 120 Volts (D) 60 Volts

Description : When secondary of a current transformer is open-circuited its iron core will be?

Last Answer : When secondary of a current transformer is open-circuited its iron core will be hot because of heavy iron losses taking place in it due to high flux density.

Description : The secondary of a current transformer is always short-circuited under operating conditions because it?

Last Answer : The secondary of a current transformer is always short-circuited under operating conditions because it avoids core saturation and high voltage induction.

Description : In a transformer the resistance between its primary and secondary should be?

Last Answer : In a transformer the resistance between its primary and secondary should be infinity.

Description : If the fault current is 2000 A, the relay setting is 50% and CT ratio is 400:5, the plug setting multiplier will be

Last Answer : If the fault current is 2000 A, the relay setting is 50% and CT ratio is 400:5, the plug setting multiplier will be 10 A

Description : A shunt fault is characterized by (A) Increase in current, frequency and pf (B) Increase in current, reduction in frequency and pf (C) Increase in current and frequency, reduction in pf (D) Decrease in current and frequency

Last Answer : B

Description : In which fault the maximum short circuit current occurs?

Last Answer : In three phase bolted fault the maximum short circuit occurs.

Description : How to Clean Car Battery Terminals

Last Answer : How to Clean Car Battery Terminals How to Paint a Car One of the most common causes of false starts and poor performance in many automobiles is when car battery terminals get dirty or corroded. ... these simple steps, you never have to pay big money to replace your battery and terminals again.

Description : The number of terminals present in IGBT is A) 2 B) 3 C) 4 D) 5

Last Answer : The number of terminals present in IGBT is 3

Description : A network is said to be under resonance when the voltage and the current at the network input terminals are (A) in phase (B) out of phase (C) in phase quadrature (D) in phase, and have equal magnitudes

Last Answer : A network is said to be under resonance when the voltage and the current at the network input terminals are in phase

Last Answer : Service mains are the conductors, which connect the consumer's terminals to the distribution.

Description : A MOSFET has how many terminals?

Last Answer : A MOSFET having three terminals 1st one is Gate (insulated), 2nd one is Source and 3rd one is Drain.

Last Answer : BJT have three terminals Base, emitter and collector.

Last Answer : Thyristor have three terminals anode, cathode and Gate.

Last Answer : Diode have two terminals.

Description : Give the causes and impact and reasons of grid system fault. 

Last Answer : Following are the causes/reasons grid system fault: 1. Major imbalance between generation and consumption i.e. demand is more than generation. 2. Low frequency, due to some faults the frequency ... of supply and causes inconvenience to people. 6. Disturb the routine work of common all people.

Description : If the fault current is 6000 A, the relay plug setting is 150% and the CT ratio is 400/5, the plug setting multiplier will be

Last Answer : If the fault current is 6000 A, the relay plug setting is 150% and the CT ratio is 400/5, the plug setting multiplier will be 10

Description : If the % reactance upto the fault point is 20%, then the short circuit current will be

Last Answer : If the % reactance upto the fault point is 20%, then the short circuit current will be 5 times the full load current

Description : With fault clearing time, the transient stability of a power system

Last Answer : With fault clearing time, the transient stability of a power system decreases

Last Answer : Fault diverters are basically fast switches.

Description : Which is the most common type of fault?

Last Answer : Single phase to ground fault is the most common type of fault.

Description : Does Delta have something that I can plug my computer in to for power?

Last Answer : Older planes have to be retrofitted to have a power source by every seat. It is pretty standard on newer planes. Without knowing the the type of plane it would be impossible to know. And even with that it might be hard to say for certain. Your best bet is to call and ask.

Description : Delta to Wye Conversion

Last Answer : Delta to Wye Conversion

Description : Wye and delta conversion formula

Last Answer : Wye and delta conversion formula

Description : Wye Delta Transformation

Last Answer : Wye Delta Transformation 1 : https://youtu.be/mPKeczDWZCo Wye Delta Transformation 2 : https://youtu.be/k80VbHI-wwg Wye Delta Transformation 3 : https://youtu.be/6cnwj15uw5M Wye Delta Transformation ... 8 : https://youtu.be/knRb5UW1404 Wye Delta Transformation 9 : https://youtu.be/JBwHKBJ08WM

Description : Explain Three Phase Bidirectional Delta Connected Controller.

Last Answer : Three Phase Bidirectional Delta Connected Controller:

Description : A 4000 kVA, 11 kV/132 kV delta-star connected 3-phase transformer has reactance, x1 = 0.12 p.u. The actual value of x1 referred to the low voltage side is (A) 0.85 Ω (B) 3.63 Ω (C) 36.3 Ω (D) 252 Ω

Last Answer : A 4000 kVA, 11 kV/132 kV delta-star connected 3-phase transformer has reactance, x1 = 0.12 p.u. The actual value of x1 referred to the low voltage side is 3.63 Ω

Description : How to Install an Above Ground Pool

Last Answer : How to Install an Above Ground Pool Having an above the ground pool would be a nice addition to your house. It can be a source of fun and recreation. There is even a good variety of above the ground ... for you to clean and balance out the pool's water. This should be done before you swim in it.

Description : How to Ground an Outlet

Last Answer : How to Ground an Outlet The industry standard for electrical outlets is that they must be grounded. On older homes and appliances, electrical outlets installed on the wall may not be grounded at all ... you can replace the old-fashioned electrical system in your home and replace it with safe ones.

Description : Describe the concept of virtual ground with reference to op-Amp.

Last Answer : Virtual ground concept:-In circuit point A is virtual ground. Figure shows inverting amplifier using op-amp. In this circuit non-inverting terminal is connected to the actual ground. Due to ... zero potential without actually grounding is known as virtual ground concept. Circuit diagram: 

Description : A minimum clearance of 6.3 m to ground is required for overhead lines when operating voltages are :  (A) less than 66 kV (B) lie between 66 kV and 110 kV (C) more than 165 kV (D) lie between 110 kV and 165 kV

Last Answer : A minimum clearance of 6.3 m to ground is required for overhead lines when operating voltages are : lie between 66 kV and 110 kV

Description : On the ladder resting on the ground and leaning against a smooth vertical wall, the force of friction will be?

Last Answer : On the ladder resting on the ground and leaning against a smooth vertical wall, the force of friction will be zero at its upper end.

Description : On a ladder resting on smooth ground and leaning against vertical wall, the force of friction will be?

Last Answer : On a ladder resting on smooth ground and leaning against vertical wall, the force of friction will be upwards at its upper end.

Description : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be?

Last Answer : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be at the slot edge where coil enters or comes out of the slot.

Last Answer : The ground wire should not be smaller than No 10 copper.

Last Answer : To avoid electric shock from electrical appliances to the human body 

Description : Shunt compensation in an EHV line is used to (A) Improve stability. (B) Improve the voltage profile. (C) Reduce the fault level. (D) Substitute for synchronous phase modifier.

Last Answer : Shunt compensation in an EHV line is used to Improve the voltage profile.

Description : Series capacitive compensation in EHV transmission line is used to

Last Answer : To maintain voltage stability