Damper winding is provided in 3 phase synchronous motors to :

1 Answer

Answer :

Damper winding is provided in 3 phase synchronous motors to : provide starting torque and prevent hunting

Related questions

Description : Damper winding in a synchronous motor

Last Answer : Damper winding in a synchronous motor Serves to start the motor.

Description : What is the difference between synchronous and asynchronous motors?

Last Answer : The motor which rotates at constant speed is called synchronous motor. And that constant speed is called as synchronous speed.  And the motor which does not rotates at constant speed are called asynchronous motor. Asynchronous motor is also called as Induction motor.

Last Answer : Centrifugal switch disconnects the auxiliary winding of the motor at about 70 to 80 percent of synchronous speed.

Description : In synchronous motor, does the winding losses vary with load?

Last Answer : No, in the synchronous motor the winding losses do not vary with load.

Last Answer : In a capacitor start and run motors the function of the running capacitor in series with the auxiliary winding is to improve power factor.

Description : SYNCHRONOUS MOTORS MCQ

Last Answer : 101. In a synchronous motor it the back e.m.f. generated in the armature at noload is approximately equal to the applied voltage, then (a) the motor is said to be fully loaded (b) the torque ... square of the applied voltage (c) inversely proportional to applied voltage (d) none of the above Ans: a

Last Answer : The standard full-load power factor ratings for synchronous motors are unity or 0.8 leading.

Last Answer : Synchronous motors are generally not self-starting because the direction of instantaneous torque reverses after half cycle.

Last Answer : For power factor correction, synchronous motors operate at no-load and greatly over-excited fields.

Last Answer : If the field winding of an unloaded salient pole synchronous motor is open circuited, the motor will stop.

Description : The damping winding in synchronous motor is generally used to?

Last Answer : The damping winding in synchronous motor is generally used to provide starting torque and prevent hunting.

Description : In case of conductively compensated D.C. series motors, the compensating winding is provided?

Last Answer : In case of conductively compensated D.C. series motors, the compensating winding is provided in series with armature winding.

Last Answer : The capacitors used in single-phase capacitor motors have no polarity marking.

Last Answer : The starting winding of a single-phase motor is placed in stator.

Last Answer : If starting winding of a single-phase induction motor is left in the circuit, it will draw excessive current and overheat.

Last Answer : Starting winding of a single phase motor of a refrigerator is disconnected from the circuit by means of a magnetic relay.

Last Answer : In split phase motor main winding is of thick wire placed at the bottom of the slots.

Description : The speed of a 2-pole, 3-phase stepper motor operated by 1200 pulses/min (A) 100 rpm (B) 200 rpm (C) 400 rpm (D) 800 rpm

Last Answer : The speed of a 2-pole, 3-phase stepper motor operated by 1200 pulses/min 200 rpm

Description : Stepper motors are used in  (1) printers (2) lifts (3) amplifiers (4) oscillators

Last Answer : Stepper motors are used in printers 

Description : Slot harmonics are reduced in induction motors by using (A) fractional-pitch windings (B) fractional-slot windings (C) integral-slot windings (D) distributed windings

Last Answer : Slot harmonics are reduced in induction motors by using fractional-slot windings

Description : Generally, Crawling in squirrel cage induction motors is tendency to run stably at speeds as low as (A) One-third of their synchronous speed (B) One-fifth of their synchronous speed (C) One-seventh of their synchronous speed (D) One-ninth of their synchronous speed

Last Answer : Generally, Crawling in squirrel cage induction motors is tendency to run stably at speeds as low as One-seventh of their synchronous speed

Description : Which of the following test is usually conducted to determine the efficiency of traction motors ? (A) Field’s test (B) Swinburne’s test (C) Hopkinson’s test (D) Retardation test.

Last Answer : Which of the following test is usually conducted to determine the efficiency of traction motors ? (A) Field’s test (B) Swinburne’s test (C) Hopkinson’s test (D) Retardation test.

Description : Which of the following motors is being extensively used in servo applications ? A. AC motor B. Field controlled dc motor C. Armature controlled dc motor D. None of these

Last Answer : Which of the following motors is being extensively used in servo applications ? A. AC motor B. Field controlled dc motor C. Armature controlled dc motor D. None of these

Last Answer : In case of D.C. shunt motors the speed is dependent on back e.m.f. only because flux is practically constant in D:C. shunt motors.

Last Answer : A direct online starter is used for starting motors up to 5 H.P.

Last Answer : When two D.C. series motors are connected in parallel, the resultant speed is normal speed.

Last Answer : In D.C. shunt motors as load is reduced the speed will remain almost constant.

Last Answer : Starters are used with D.C. motors because to restrict armature current as there is no back e.m.f. while starting.

Last Answer : Differentially compound D.C. motors can find applications requiring low starting torque.

Last Answer : Most of the fractional horsepower motors have either plain or sleeve bearings.

Last Answer : As hysteresis motors are free from mechanical and magnetic vibrations therefore these are considered as suitable for sound equipment.

Description : A _________ is used to measure the stator % winding temperature of the generator.  (A) Thermocouple (B) Pyrometer (C) Resistance thermometer (D) Thermometer

Last Answer : A Resistance thermometer is used to measure the stator % winding temperature of the generator. 

Description : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is

Last Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

Description : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively

Last Answer : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively 19,17

Description : Aluminium is not used as winding wire for the armature of a dc machine because  (1) aluminium has low resistivity (2) a large winding space is taken by aluminium conductors and creates ... ) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper

Last Answer : Aluminium is not used as winding wire for the armature of a dc machine because  (2) a large winding space is taken by aluminium conductors and creates jointing problems (3) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper

Last Answer : In D.C. machines fractional pitch winding is used to reduce the sparking.

Last Answer : The purpose of stator winding in the compensated repulsion motor is to improve power factor and provide better speed regulation.

Description : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole)  (A) has q -axis current only (B) has d -axis current only (C) has both d and q axis currents (D) cannot be divided between q and d axis currents

Last Answer : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole) has d -axis current only

Description : A three-phase synchronous motor connected to ac mains is running at full load and unity power factor. lf its shaft load is reduced by half and field current is held constant then its new power factor will be

Last Answer : Leading

Description : SINGLE PHASE INDUCTION MOTORS MCQ

Last Answer : 101. After the starting winding of a single phase induction motor is disconnected from supply, it continues to run only on (a) running winding (b) rotor winding (c) field winding (d) compensating winding Ans: a ... motor is usually reduced by using (a) gearing (b) belts (c) brakes (d) chains Ans: a

Description : THREE PHASE INDUCTION MOTORS MCQ

Last Answer : 101. Insertion of resistance in the stator of an induction motor (a) increases the load torque (b) decreases the starting torque (c) increases the starting torque (d) none of the above Ans: b

Last Answer : In capacitor start single-phase motors current in the starting winding leads the voltage.

Last Answer : In split-phase motor auxiliary winding is of thin wire placed at the top of the slots.

Description : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be?

Last Answer : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be at the slot edge where coil enters or comes out of the slot.

Last Answer : In a capacitor start motor, the phase displacement between starting and running winding can be nearly 90°.

Last Answer : In a split phase motor, the running winding should have low resistance and high inductance.

Last Answer :  Sandwich type winding is used in 3 phase shell-type transformer.

Description : In a synchronous machine, if the field flux axis ahead of the armature field axis in the direction of rotation, the machine is operating as  (1) synchronous motor (2) synchronous generator (3) asynchronous motor (4) asynchronous generator

Last Answer : In a synchronous machine, if the field flux axis ahead of the armature field axis in the direction of rotation, the machine is operating as synchronous generator 

Description : In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load  (A) The armature current increases and the power factor decreases  (B) The armature ... but is lagging  (D) The armature current decreases and the power factor increases and is leading

Last Answer : In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load The armature current decreases and the power factor increases and is leading

Description : In a synchronous generator delivering lagging power factor load  (1) the excitation emf leads terminal voltage by the power angle (2) the excitation emf lags terminal voltage by the power angle (3) ... by the power factor angle (4) excitation emf lags the terminal voltage by the power factor angle

Last Answer : In a synchronous generator delivering lagging power factor load the excitation emf leads terminal voltage by the power angle