The ratio of full -load volt-amperes to short-circuit volt-amperes is equal to :

1 Answer

Answer :

The ratio of full -load volt-amperes to short-circuit volt-amperes is equal to : Z (p.u)

Related questions

Last Answer : A synchronous machine with low value of short-circuit ratio has lower stability limit.

Last Answer : The ratio of starting torque to full-load torque is least in case of shunt motors.

Last Answer : The duration of sudden short-circuit test on a synchronous motor is usually about one second.

Description : At full -load of a transformer, the iron loss and copper loss are 3000 W and 4000 W respectively. Then total loss at maximum efficiency is :  (A) 7000 W (B) 6000 W (C) 8000 W (D) 4000 W

Last Answer : At full -load of a transformer, the iron loss and copper loss are 3000 W and 4000 W respectively. Then total loss at maximum efficiency is : 6000 W

Last Answer : The standard full-load power factor ratings for synchronous motors are unity or 0.8 leading.

Description : The voltage transformation ratio of a transformer is equal to the ratio of?

Last Answer : The voltage transformation ratio of a transformer is equal to the ratio of secondary induced e.m.f. to primary induced e.m.f.

Description : Voltage ratio

Last Answer : Voltage ratio

Description : Turns ratio

Last Answer : Turns ratio formula

Description : Impedance ratio

Last Answer : Impedance ratio

Description : Current ratio

Last Answer : Current ratio

Description : The ratio of the width to the height of the picture frame is called as A) Rastar B) Aspect Ratio C) Length Ratio D) Efficiency  

Last Answer : The ratio of the width to the height of the picture frame is called as Aspect Ratio

Description : If Poisson's ratio of a resistance wire strain gauge is 1.8, then neglecting piezo-resistive effects, its Gauge factor is :  (A) 2.8 (B) 2.6 (C) 4.6 (D) 3.6

Last Answer : If Poisson's ratio of a resistance wire strain gauge is 1.8, then neglecting piezo-resistive effects, its Gauge factor is : 4.6

Description : The ratio of active power to apparent power is known as____ factor.

Last Answer : The ratio of active power to apparent power is known as power factor.

Last Answer : The form factor is the ratio of r.m.s. value to average value.

Description : In otto cycle compression ratio is 8. Calculate air standard efficiency. Will it be grater than Carnot Cycle ? Justify your answer. 

Last Answer : No, the Otto cycle efficiency 56.47% will always be lower than Carnot cycle efficiency. Justification: Carnot theorem states that keeping operating conditions same, Carnot engine is more efficient than any other engine. So, Otto cycle efficiency is lower than Carnot cycle efficiency. 

Description : Graph indicating changes in pollutants level w.r.t air fuel ratio

Last Answer : Graph indicating changes in pollutants level w.r.t air fuel ratio

Description : Compressor pressure ratio (CPR)

Last Answer : Compressor pressure ratio (CPR), is the ratio of the air total pressure exiting the compressor to the air pressure entering the compressor. This number is always greater than 1.0.

Description : SEER: Seasonal Energy Efficiency Ratio (SEER)

Last Answer : SEER: Seasonal Energy Efficiency Ratio (SEER), is most commonly used to measure the efficiency of a central air conditioner. The higher the SEER, the more efficient the system OR It is the ... the ratio of total capacity to the total KW energy usage at specific humidity and temperature condition.

Description : Define: 1) voltage ratio, 2) current ratio, 3) transformation ratio of transformer.

Last Answer : 1) Voltage ratio: The voltages in primary and secondary winding is proportional to number of turns in primary and secondary respectively. So, the voltage ratio is same as transformation ratio. V2/V1 = N2 ... as transformation ratio of transformer. It is denoted by K. K = N2/N1

Description : What is transformation ratio?

Last Answer : Transformation Ratio (k):- It is the ratio of secondary number of turns to primary number of turns. OR It is the ratio of secondary voltage to primary voltage. OR It is the ratio of primary current to secondary current. 

Description : If the fault current is 6000 A, the relay plug setting is 150% and the CT ratio is 400/5, the plug setting multiplier will be

Last Answer : If the fault current is 6000 A, the relay plug setting is 150% and the CT ratio is 400/5, the plug setting multiplier will be 10

Description : Given a unity feedback system with G(s)=k/s (s+4), the value of k for damping ratio of 0.5 is

Last Answer : Given a unity feedback system with G(s)=k/s (s+4), the value of k for damping ratio of 0.5 is 16

Description : A dc chopper is fed from a constant voltage mains the duty ratio of chopper is progressively increased while the chopper feeds an RL load. The per unit current ripple would  (1) increase progressively  (2 ... 0.5 and then increase  (4) increase to a maximum value at α = 0.5 and then decrease

Last Answer : A dc chopper is fed from a constant voltage mains the duty ratio of chopper is progressively increased while the chopper feeds an RL load. The per unit current ripple would increase to a maximum value at α = 0.5 and then decrease

Description : Specific energy consumption of an electric train is the ratio between (A) Specific energy output at driving wheels and efficiency of the traction motor (B) Specific energy output at driving wheels ... (D) Specific energy output at driving wheels and efficiency of the (motor + transmission gear)

Last Answer : Specific energy consumption of an electric train is the ratio between Specific energy output at driving wheels and efficiency of the (motor + transmission gear)

Description : Ratio of the rotor reactance X to the rotor resistance R for a two-phase servo motor (A) is equal to that of a normal induction motor (B) is less than that of a normal induction motor (C) ... than that of a normal induction motor (D) may be less or greater than that of a normal induction motor

Last Answer : C

Description : The Eb/V ratio of a d.c. motor is an indication of its?

Last Answer : The Eb/V ratio of a d.c. motor is an indication of its efficiency.

Description : The ratio of mass of proton to that of electron is nearly?

Last Answer : The ratio of mass of proton to that of electron is nearly 1840.

Description : Two bulbs of 500 W and 200 W rated at 250 V will have resistance ratio as?

Last Answer : Two bulbs of 500 W and 200 W rated at 250 V will have resistance ratio as 2 : 5.

Description : The ratio of limiting friction and normal reaction is known as?

Last Answer : The ratio of limiting friction and normal reaction is known as coefficient of friction.

Last Answer : The mechanical power developed by a shunt motor will be maximum when the ratio of back e.m.f. to applied voltage is 0.5.

Description : Auto-transformer makes effective saving on copper and copper losses, when its transformation ratio is?

Last Answer : Auto-transformer makes effective saving on copper and copper losses, when its transformation ratio is approximately equal to 1.

Description : Use of auto-transformer is economical when the transformation ratio is?

Last Answer : Use of auto-transformer is economical when the transformation ratio is near unity.

Description : Two 100 watt light bulbs are connected in parallel across a 100 volt power supply. The total power developed in the circuit is _______________. A. 200 watts B. 100 watts C. 50 watts D. equal to the product of the amperes times the voltage in each branch

Last Answer : Answer: A

Description : Which of the following precautions should be taken when a blown fuse, rated at 10 amperes, is replaced? A. Short out the fuse before removing it from the circuit. B. Use needle-nose pliers to ... D. Fuses of 10 ampere rating and less are virtually harmless when energized and may be handled freely.

Last Answer : Answer: C

Description : A circuit breaker for a 300 KW alternator is rated at 470 amperes of full continuous load. The amount of overcurrent allowed is 125%. Which of the following conditions will trip the breaker? A. ... 10 minutes. C. Momentary starting load of 550 amperes. D. Sustained current flow of 590 amperes.

Last Answer : Answer: D

Description : As shown in the illustration, the function of the switch labeled 'PFSW' is to determine the ______________. EL-0003 A. bus frequency B. reactive volt amperes of the bus C. frequency of either generator D. power factor of either generator

Last Answer : Answer: D

Description : An electrical component is connected across a 120 volt 60 hertz AC supply. What is the current drawn by the component if the impedance is 200 ohms? A. 0.01 amperes B. 0.60 amperes C. 1.67 amperes D. 100 amperes

Last Answer : Answer: B

Description : What current is required to light two 75 watt lamps and one 40 watt lamp when connected in series to a 120 volt power source? A. 0.161 amperes B. 0.631 amperes C. 1.583 amperes D. 6.199 amperes

Last Answer : Answer: C

Description : Battery capacities are given in _____________. A. volts B. volt-amperes C. volt-hours D. ampere-hours

Last Answer : Answer: D

Description : Electric current is the flow of electrons through a conductor. The rate of this flow is measured as ___________. A. volts/watt B. amperes/centimetre C. coulombs/second D. ohms/volt

Last Answer : Answer: C

Description : For a given base voltage and base volt-amperes, the per unit impedance value is x. For the doubled base values of both voltage and volt-amperes, the per unit impedance will be (a) 2x (b) 0.25x (c) 0.5x (d) no change 

Last Answer : Answer is 2x Base impedance =(base voltage) ²/base current 

Description : To properly use a hook-on-type volt/ammeter to check current flow, you must FIRST _____________. A. de-energize the circuit to allow connection of the instrument in series B. hook the jaws ... test leads to the appropriate terminals D. short the test leads and calibrate the instrument to zero

Last Answer : Answer: B

Description : The distance between a generator and its load is 100 feet. What would be the approximate total voltage drop across a two wire supply cable if the current were 5.5 amperes and the resistance of the wire were 2.525 ohms per 1,000 feet? A. 0.5 volts B. 1.38 volts C. 1.90 volts D. 2.77 volts

Last Answer : Answer: D

Description : Which of the following statements regarding the use of a current measuring instrument is correct? A. It must be connected in series with the circuit. B. You should always start with the lowest range ... of polarity. D. An external shunt is generally utilized where current is less than 10 amperes.

Last Answer : Answer: A

Description : What is the power used in a circuit that has 10 amperes of current through a 10-ohm resistor?

Last Answer : 1 kilowatt.

Description : If Eeff is 130 volts and Ieff is 3 amperes, what is the total resistance (RT) in the circuit?

Last Answer : 43.3 ohms.

Description : The ratio of the effective value of the counter EMF in volts, to the effective value of the current in amperes is called _____________. A. impedance factor B. capacitive reactance C. inductive reactance D. root mean square

Last Answer : Answer: C

Description : Ten Coulombs of charge flowing through a wire per second is equal to: w) 100 Amperes x) 10 Ampere y) 1 Amperes z) 0.1 Amperes

Last Answer : ANSWER: X -- 10 AMPERES

Description : A current of 4 amperes flowing for 45 minutes deposits 1.062 gm of metal at cathode. Calculate the equivalent weight of the metal. (Given 1 Faraday = 96500 C)

Last Answer : Given:  c : 4 amperes   t : 45 minutes : 45 x 60 = 2700 seconds   w : 1.062 gm   1 Faraday : 96500 C  To calculate: Eq. Weight (CE)  According to Faraday's first law:   w = z c t Therefore,  z = w / ct  ... g/c   Now, C.E. = 96500 x E.C.E.   C. E. = 96500 x 0.00009833  C.E. = 9.4888 gm