For selecting a circuit breaker, ______ should be determined. 

(A) initial current that flows on occurrence of a short circuit only (B) transient current that flows at the time of circuit interruption only (C) resonant frequency only (D) (A) and (B) 

1 Answer

Answer :

For selecting a circuit breaker, ______ should be determined. (A) initial current that flows on occurrence of a short circuit only (B) transient current that flows at the time of circuit interruption only (C) resonant frequency only (D) (A) and (B) 

Related questions

Last Answer : Magnetic circuit breaker has instantaneous trip action.

Description : The arc temperature in Oil Circuit Breaker may reach up to_______.  (A) 5,000° K (B) 8,000° K (C) 10,000° K (D) None of the above

Last Answer : The arc temperature in Oil Circuit Breaker may reach up to 5,000° K 

Description : The number of cycles in which a high speed circuit breaker can complete its operation is  (A) 3 to 8 (B) 10 to 18 (C) 20 to 30 (D) 40 to 50

Last Answer : The number of cycles in which a high speed circuit breaker can complete its operation is 3 to 8

Description : A circuit breaker is designed to protect an electrical circuit from damage caused by :  (A) Over load (B) Short circuit (C) Over current (D) All of the above

Last Answer : A circuit breaker is designed to protect an electrical circuit from damage caused by :  (A) Over load (B) Short circuit (C) Over current (D) All of the above

Description : The Minimum Oil Circuit Breaker (MOCB) is named because of :  (A) Reduced requirement of oil (B) Reduced requirement of air (C) All of the above (D) None of the above

Last Answer : The Minimum Oil Circuit Breaker (MOCB) is named because of : Reduced requirement of oil 

Description : ln a minimum oil circuit breaker the oil is used

Last Answer : ln a minimum oil circuit breaker the oil is used to act as circuit breaking medium only

Last Answer : Arc in a circuit breaker is interrupted at zero current.

Last Answer : The arc voltage produced in A.C. circuit breaker is always in phase with the arc current.

Last Answer : In a circuit breaker the basic problem is to transmit large power.

Last Answer : Ionization in circuit breaker is facilitated by high temperature, increase of mean free path, increasing field strength.

Last Answer : The voltage appearing across the contacts after opening of the circuit breaker is called recovery voltage.

Last Answer : Air blast circuit breaker is used for repeated duty.

Last Answer : Thermal circuit breaker has delayed trip action.

Last Answer : The arcing contacts in a circuit breaker are made of copper tungsten alloy.

Description : what is SF6 circuit breaker?

Last Answer : SF6 is Sulpher hexa Fluoride gas. If this gas is used as arc quenching medium in a Circuit breaker means SF6 CB.

Description : Explain about Circuit Breaker

Last Answer : Ans: CIRCUIT BREAKERS: In the case of outdoor type installation, the circuit breakers have fixed location and the station layout is such that adequate section clearances are always available from ... carried out as above, every circuit breaker will be completely overhauled after five year interval.

Description : How to Reset a Circuit Breaker

Last Answer : How to Reset a Circuit Breaker All is well with the lights and your electrical appliances one minute, then everything falls into pitch-black darkness the next moment. When a room in your house ... electrical fires. With these tips, a power surge does not have to be a permanent inconvenience.

Description : How to Install a Circuit Breaker

Last Answer : How to Install a Circuit Breaker A circuit breaker is an essential component of a home's electric system. When power surges occur, it trips then shuts off the electricity, preventing ... -functional electrical system. Just make sure you take proper safety precautions when installing this device.

Description : Explain working of static AC circuit breaker. 

Last Answer : Static AC Circuit breaker: The circuit configuration of static AC circuit breaker using SCR is shown in the figure. When switch S' is closed, the SCRs T1 and T2 are fired in positive ... non-availability of gate current. Thus the maximum time delay for breaking the circuit is one half-cycle.

Description : Explain working of AC circuit breaker using SCR with circuit diagram.

Last Answer : AC Circuit Breaker:  The circuit configuration of static AC circuit breaker using SCR is shown in the figure. When switch S' is closed, the SCRs T1 and T2 are fired in positive ... to non-availability of gate current. Thus the maximum time delay for breaking the circuit is one half-cycle.

Description : State function of starter and ELCB. (Earth Leakage Circuit Breaker)

Last Answer : i) Function of Starter:- 1. To prevent the high starting current OR to minimize the starting current. 2. To give supply failure protection 3. To give over load and short circuit protection ... an installation and cut off the circuit from power supply and avoid electrical shock to the person.

Description : Breaking capacity of a circuit breaker is usually expressed in terms of  (1) Ampere (2) Volts (3) MW (4) MVA

Last Answer : Breaking capacity of a circuit breaker is usually expressed in terms of MVA

Description : The arc voltage in a circuit breaker is :

Last Answer : The arc voltage in a circuit breaker is : in phase with the arc current

Description : Which of the following is used in a circuit breaker as the medium in which the arc forms? A) Insulating gas B) Insulating oil C) Vacuum D) All the above

Last Answer : Which of the following is used in a circuit breaker as the medium in which the arc forms? A) Insulating gas B) Insulating oil C) Vacuum D) All the above

Description : If the % reactance upto the fault point is 20%, then the short circuit current will be

Last Answer : If the % reactance upto the fault point is 20%, then the short circuit current will be 5 times the full load current

Description : Which of the following circuit breakers has high reliability & minimum maintenance?  (A) Bulk oil type CB (B) Air blast CB (C) Vacuum CB (D) Sulphur hexafluoride CB 

Last Answer : Which of the following circuit breakers has high reliability & minimum maintenance?  (A) Bulk oil type CB (B) Air blast CB (C) Vacuum CB (D) Sulphur hexafluoride CB 

Description : The following is/are the characteristics of SF6 circuit breakers:  (A) It does not need an auxiliary breaking chamber (B) Short break time of 2 to 2.5 cycles (C) All of the above (D) None of the above

Last Answer : The following is/are the characteristics of SF6 circuit breakers:  (A) It does not need an auxiliary breaking chamber (B) Short break time of 2 to 2.5 cycles (C) All of the above (D) None of the above

Last Answer : A fuse in a motor circuit provides protection against short-circuit and overload.

Last Answer : Air blast circuit breakers for 400 kV power system are designed to operate in 50 millisecond.

Last Answer : The short circuit in any winding of the transformer is the result of impulse voltage.

Last Answer : The time of closing the cycle, in modern circuit breakers is 0.003 sec.

Description : The current zero interruption, in oil and air blast circuit breakers, is achieved by?

Last Answer : The current zero interruption, in oil and air blast circuit breakers, is achieved by lengthening of the gap, cooling and blast effect.

Last Answer : Circuit breakers are essentially current carrying contacts called electrodes.

Last Answer : Circuit breakers usually operate under transient state of short-circuit current.

Description : Arc in a circuit behaves as?

Last Answer : Arc in a circuit behaves as a resistance decreasing with voltage rise across the arc.

Description : In which fault the maximum short circuit current occurs?

Last Answer : In three phase bolted fault the maximum short circuit occurs.

Description : A circuit that binds the upper or lower extreme of a waveform to a fixed DC voltage level is called ______ A) DC voltage restorer B) Clamping circuit C) Both A and B D) None of these

Last Answer : A circuit that binds the upper or lower extreme of a waveform to a fixed DC voltage level is called ______ A) DC voltage restorer B) Clamping circuit C) Both A and B D) None of these

Description : At ______ frequencies the parallel R-L circuit behaves as purely resistive.

Last Answer : At very high frequencies the parallel R-L circuit behaves as purely resistive.

Description : Can An Rc Circuit Be Used As Clock Source For 8085?

Last Answer : Answer :Yes, it can be used, if an accurate clock frequency is not required. Also, the component cost is low compared to LC or Crystal.

Description : What is the purpose of Overload Protection in a motor circuit?

Last Answer : Ans. The Overload Protection is used in a motor circuit to protect it from sustained over currents.

Description : How to Do Circuit Training

Last Answer : How to Do Circuit Training Circuit exercise is a set of exercises designed to burn as much calories as possible while integrating and engaging different kinds of movements all over your body. After finishing ... up your stamina to be able to finish five circuits in a session, so pace yourself.

Description : Draw the circuit diagram of battery charger using SCR and explain it’s working.

Last Answer : Battery charger circuit using SCR: The figure shows the battery charger circuit using SCR. A 12V discharged battery is connected in the circuit and switch SW is closed. The singlephase 230V ... not fired. In this way, after full charging, further charging is automatically stopped.

Description : With neat diagram explain synchronized UJT triggering circuit.

Last Answer : Line Synchronized UJT triggering circuit: The UJT is almost ideal as a firing device for SCRs. There are 2 main reasons for the compatibility between UJTs and SCRs. Firstly, the UJT produces a ... , the SCR is sure to have the right polarity between the anode and cathode for turning on.

Description : Draw circuit diagram of symmetrical configuration of bridge converter.

Last Answer : circuit diagram of symmetrical configuration of bridge converter

Description : Draw circuit diagram of Class B commutation.

Last Answer : Class B: Resonant Pulse Commutation:

Description : Equivalent circuit of transformer

Last Answer : Equivalent Circuit Diagram of Transformer Referred to Primary: V1 -Primary Input voltage I1 - Input Current I0- Exciting current/ No load current Im- Magnetizing component ... equivalent of secondary terminal voltage ZL- Load impedance ZL ′- Primary equivalent of load impedance

Description : Briefly explain how the power factor of an inductive circuit can be improved.

Last Answer : As we know that power factor should be corrected to ensure that the current supplied is cost friendly. Meaning the power factor should be around one but not greater than one(0.8-0.9) in a ... an inductive circuit due to the inductive reactance which oppose the change of current in the ac circuit. 

Description : Draw equivalent circuit of alternator.

Last Answer : Equivalent circuit of alternator

Description : Describe the working principle of Thyristor operated dimmer with the help of circuit diagram.

Last Answer : Thyristor operated dimmer: A popular thyristor operated dimmer circuit employ TRIAC-DIAC phase control for low AC power control. During each half-cycle, the capacitor charges through (R1+VR1). When the ... time constant {C (R1+VR1)}. Thus by reducing VR1 the lamp brightness can be increased.

Description : Define Multivibrator. State the types of multivibrator. Which M/V can be used as a flip-flop? Draw the circuit diagram.

Last Answer : Definition:- A multivibrator is an electronic circuit that switches rapidly by means of positive feedback between two or more states.  OR  A multivibrator is an electronic circuit used to implement a ... Bistable Multivibrator: it can operate as a flip-flop, Circuit diagram