Generally in a power system network, the load is represented as a : 

(A) Constant power in both load flow study and in stability study 

(B) Constant power in load flow study and constant impedance in stability study 

(C) Constant power in stability study and constant impedance in load flow study 

(D) Constant impedance in both load flow study and in stability study

1 Answer

Answer :

Generally in a power system network, the load is represented as a : Constant power in load flow study and constant impedance in stability study 

Related questions

Description : The sequence components of current of a single-phase load connected to a 3-phase system are (A) equal positive and negative sequence components (B) equal positive, negative and zero sequence components (C) vector sum of sequence currents is zero (D) algebraic sum of sequence currents is zero

Last Answer : The sequence components of current of a single-phase load connected to a 3-phase system are equal positive, negative and zero sequence components

Description : A transformer has negative voltage regulation when its load power factor is   (1) Zero (2) Unity (3) Leading (4) Lagging

Last Answer : 0

Description : Load compensation in power systems is a process to :  (A) Maintain better voltage profile (B) Increase short circuit capacity of the system (C) Generate required harmonics for loads like arc furnaces (D) Compensate for the line reactance

Last Answer : Load compensation in power systems is a process to : Maintain better voltage profile

Description : Power station having Load factor = 70%, capacity factor = 50%, used factor = 60%, maximum demand = 20MW then annual energy production is  (1) 122.8 GWh (2) 198.55 GWh (3) 128.2 GWh (4) 188.82 GWh

Last Answer : Power station having Load factor = 70%, capacity factor = 50%, used factor = 60%, maximum demand = 20MW then annual energy production is 122.8 GWh

Description : The power flow problem mathematical model for a linear transmission network (A) is non-linear (B) is linear (C) considers time variation of generation (D) does not consider tap-changing transformers

Last Answer : The power flow problem mathematical model for a linear transmission network is non-linear

Last Answer : Load factor of a power station is generally less than unity.

Description : The stability of the power system is not affected by  (1) generator reactance (2) line reactance (3) line losses (4) output torque

Last Answer : The stability of the power system is not affected by line losses

Description : The benefit of power factor correction in a power system is (A) lower power consumption (B) increased demand charge (C) reduced load carrying capabilities in existing lines (D) reduced voltage profile

Last Answer : The benefit of power factor correction in a power system is lower power consumption

Description : If non-linear loads are connected to the power system, then (A) displacement power factor is same as the total power factor (B) displacement power factor is not equal to the total power ... factor is due to harmonic currents (D) total power factor is due to fundamental component of current

Last Answer : If non-linear loads are connected to the power system, then displacement power factor is not equal to the total power factor

Description : State why nuclear power plants are used as base load plants and diesel power plants as a peak load plant. 

Last Answer : 1. Because of following points Nuclear power plant used as base load power plant:-  1. Nuclear power plants is very economical for producing bulk amount of electric power 2. Nuclear power plant is reliable ... . The plants can be put on load easily. 4. Diesel engines take less time to make OFF.

Description : In tuned power lines, on load :  (A) the receiving end voltage is numerically equal to the sending end voltage  (B) the receiving end current is numerically equal to the sending end current  (C) there is no voltage drop  (D) all the above

Last Answer : In tuned power lines, on load :  (A) the receiving end voltage is numerically equal to the sending end voltage  (B) the receiving end current is numerically equal to the sending end current  (C) there is no voltage drop  (D) all the above

Description : A 3 -phase, fully controlled, converter is feeding power into a DC load at a constant current of 150 A, the rms value of the current flowing through each thyristor of the converter is

Last Answer : Please show the solution for this question

Description : In a synchronous generator delivering lagging power factor load  (1) the excitation emf leads terminal voltage by the power angle (2) the excitation emf lags terminal voltage by the power angle (3) ... by the power factor angle (4) excitation emf lags the terminal voltage by the power factor angle

Last Answer : In a synchronous generator delivering lagging power factor load the excitation emf leads terminal voltage by the power angle

Description : The power consumed by a balanced 3-ph load is measured by two-wattmeter method. The meter readings are 8 kW and 4 kW. The power factor of the load is (A) zero (B) 0.5 (C) between zero and 0.5 (D) between 0.5 and unity

Last Answer : The power consumed by a balanced 3-ph load is measured by two-wattmeter method. The meter readings are 8 kW and 4 kW. The power factor of the load is between 0.5 and unity

Last Answer : The power factor of a single phase load can be calculated if the instruments available are three ammeters or three voltmeters.

Last Answer : Load factor of a power station is defined as average load/maximum demand.

Description : The maximum load that a power transformer can carry is limited by its?

Last Answer : The maximum load that a power transformer can carry is limited by its voltage ratio.

Description : Minimum voltage regulation occurs when the power factor of the load is?

Last Answer : Minimum voltage regulation occurs when the power factor of the load is leading.

Description : If the load of the normally excited synchronous motor is increased the power factor will?

Last Answer : If the load of the normally excited synchronous motor is increased the power factor will become lagging.

Description : The synchronous motor which works on leading power factor and does not drive any mechanical load is called?

Last Answer : The synchronous motor which works on leading power factor and does not drive any mechanical load is called synchronous condenser.

Description : The synchronous motor will develop maximum power when the load angle is?

Last Answer : The synchronous motor will develop maximum power when the load angle is 900.

Description : An SSB transmitter produces a peak-to-peak voltage of 200 V across a 100 Ω antenna load. What is the Peak Envelope Power? A) 49.98 W B) 79.98 W C) 99.96 W D) 199.93 W

Last Answer : An SSB transmitter produces a peak-to-peak voltage of 200 V across a 100 Ω antenna load. What is the Peak Envelope Power? A) 49.98 W B) 79.98 W C) 99.96 W D) 199.93 W

Description : Summerise the role of power system engineer.

Last Answer : Role of power system engineer:  i. On the planning side he or she has to make decisions on how much electricity to generate  ii. For operation of the power system he has to plan for ... for energy conservation and load management. viii. For solving the power system problems he has to update with

Description : State the functions of fuel system and exhaust system of a diesel power station.

Last Answer : Fuel system: It supplies fuel to engine for combustion purpose. It consists of Fuel Pump: - It supplies fuel to engine for combustion purpose. Strainer: - Are provided to remove suspended impurities and ... most of the noise. Chimney:- To exhaust gases in the atmosphere as high as possible. 

Description : Explain starting system in diesel electric power plant.

Last Answer : Starting system in Diesel Electric Power Plant: It includes Storage battery, compressed air tanks, self-starter etc. The purpose of engine starting system is to rotate the engine initially while ... as Ammeters, Voltmeters, Wattmeters, Thermometers, Pressure gauges, Visible and audible alarm etc.

Description : Explain fuel system and air intake system in diesel electric power plant.

Last Answer : Fuel system and air intake system in diesel electric power plant :  Fuel system: It consists of storage tank, strainers, fuel transfer pump and all day fuel tank. The fuel oil is supplied ... Filters are provided to remove dust particles from air which may act as abrasive in the engine cylinder.

Description : What is the choice of size and number of generator units in interconnected power system?

Last Answer : Choice of Size and Number of Generating Units: 1. The size/rating and number of generating units in such way that they approximately match with the load curve as closely as possible. 2. In ... , if power plant is connected to grid system then generating unit of higher capacity can be installed.

Description : A lightening arrester connected between the line and earth in a power system  (1) protects the terminal equipment against travelling surges (2) protects the transmission line against direct ... suppresses high frequency oscillations in the line (4) reflects back the travelling wave approaching it

Last Answer : A lightening arrester connected between the line and earth in a power system protects the terminal equipment against travelling surges

Description : In voltage source converter based HVDC transmission system the active power is controlled by changing (A) phase angle of the converter ac input voltage (B) supply frequency of the converter ac input voltage (C) magnitude of the converter ac input voltage (D) DC voltage at the inverter terminals

Last Answer : In voltage source converter based HVDC transmission system the active power is controlled by changing phase angle of the converter ac input voltage

Description : steady-state stability of a power system is improved by

Last Answer : steady-state stability of a power system is improved by using double circuit line instead of single circuit line

Description : For a 15-bus power system with 3 voltage controlled buses, the size of Jacobian matrix is

Last Answer : For a 15-bus power system with 3 voltage controlled buses, the size of Jacobian matrix is 25 x 25

Description : With fault clearing time, the transient stability of a power system

Last Answer : With fault clearing time, the transient stability of a power system decreases

Description : Power factor of the system is kept high?

Last Answer : Power factor of the system is kept high to reduce line losses, to maximise the utilization of the capacities of generators, lines and transformers, to reduce voltage regulation of the line.

Last Answer : Commonly used instruments in power system measurement are induction.

Last Answer : In a distribution system, in order to improve power factor, the synchronous capacitors are installed at the receiving end.

Last Answer : The primary reason for low power factor is supply system is due to installation of induction motors.

Last Answer : The steady state stability of the power system can be increased by connecting lines in parallel.

Last Answer : Air blast circuit breakers for 400 kV power system are designed to operate in 50 millisecond.

Last Answer : The contacts of high voltage switches used in power system are submerged in oil. The main purpose of the oil is to extinguish the arc.

Description : What is sag in power system?

Last Answer : Sag is a catenary curve in between two points of supporters.and also we can say the lowest point of the conductor in between the two points of supporters. 

Description : What are interconnected power system?

Last Answer : Interconnected power systems are those which connect different geographic regions. In Australia we have a National Electricity Grid which connects 6 states. Transfers of power occur between the states depending ... make more profit from this.National-Electricity-Market-Fact-Sheet.pdf (0,9 MB)

Description : What is meant by feeder in power system?

Last Answer : A feeder line is a peripheral route or branch in a network which connects smaller or more remote nodes with a route or branch carrying heavier traffic. The term is applicable to any system based on a hierarchical network.

Description : What are the components of a power system?

Last Answer : generator Traansformer Conductors Insulators

Description : In load flow Study, a PV bus is treated as a PQ bus when

Last Answer : Voltage at the bus becomes high 

Description : Load factor is the  (1) Ratio of maximum load on the station to sum of consumer's maximum load.  (2) Ratio of average demand to maximum demand.  (3) Factor used for increasing load.  (4) Reciprocal of (1).

Last Answer : Load factor is the Ratio of average demand to maximum demand. 

Description : The load duration curve for unity load factor will be of  (1) Rectangular shape (2) Triangular shape (3) L -shape (4) I -shape

Last Answer : The load duration curve for unity load factor will be of Rectangular shape

Description : The following formula is correct:  (A) Load factor=Average load for a period/ Peak load for the same period  (B) Load factor=Average load for a period x Peak load for the same period  (C) Load factor=Average load for a period + Peak load for the same period  (D) All of the above

Last Answer : The following formula is correct: (A) Load factor=Average load for a period/ Peak load for the same period (B) Load factor=Average load for a period x Peak load for the same period (C) Load factor=Average load for a period + Peak load for the same period (D) All of the above

Description : The storage battery generally used in electric power stations is  (1) zinc carbon battery (2) lead acid battery (3) nickel cadmium battery (4) lithium -ion battery

Last Answer : The storage battery generally used in electric power stations is lead acid battery 

Description : An _____________is a network of electrical components used to supply, transfer and use electric power:  (A) Electric power system (B) Electric power (C) All of the above (D) None of the above

Last Answer : An Electric power system is a network of electrical components used to supply, transfer and use electric power.