A negative sequence relay is used for protection of 

(1) Generator (3) Motor (2) Transformer (4) Long Transmission lines

1 Answer

Answer :

A negative sequence relay is used for protection of Generator 

Related questions

Description : A relay used for protection of motors against overload is :  (A) Impedance relay (B) Electromagnetic attraction type (C) Thermal relay (D) Buchholz's relay

Last Answer : D

Description : Reactance relay is normally preferred for protection against

Last Answer : Reactance relay is normally preferred for protection against earth faults

Last Answer : The under voltage relay can be used for generators, busbars, transformers, motors.

Description : Surge absorbers are used for protection against

Last Answer : Surge absorbers are used for protection against low voltage high frequency oscillations

Last Answer : The inverse definite mean time relays are used for over current and earth fault protection of transformer against internal short-circuits.

Last Answer : The single phasing relays are used for the protection of three phase motors.

Description : The purpose of the restraining coil in a biased differential relay is  (A) To reduce CT saturation during fault.  (B) To increase the sensitivity of the relay.  (C) To match the transformation ratio.  (D) To limit the spill current through the relay during heavy external fault.

Last Answer : d

Description : A relay has a rating of 5 A, 2.2 sec IDMT and a relay setting of 125% TMS = 0.6. It is connected to a supply circuit through a C.T. 400/5 ratio. The fault current is 4000 A. The operating current of the relay is

Last Answer : A relay has a rating of 5 A, 2.2 sec IDMT and a relay setting of 125% TMS = 0.6. It is connected to a supply circuit through a C.T. 400/5 ratio. The fault current is 4000 A. The operating current of the relay is 6.25A

Description : The operating time of instantaneous relay is

Last Answer : The operating time of instantaneous relay is 0.1 sec

Description : What is the difference between relay and contactor?

Last Answer : Relay have smaller ratings. Contactor is a high rating relay.

Description : Buchholz relay is  (1) located in the conservator tank  (2) located in the transformer tank itself  (3) connected in the pipe connecting main tank of transformer and conservator  (4) installed in the circuit breaker

Last Answer : Buchholz relay is connected in the pipe connecting main tank of transformer and conservator 

Description : To prevent mal-operation of differentially connected relay while energizing a transformer, the relay restraining coil is based with  (1) second harmonic current  (2) third harmonic current  (3) fifth harmonic current  (4) seventh harmonic current

Last Answer : To prevent mal-operation of differentially connected relay while energizing a transformer, the relay restraining coil is based with  second harmonic current 

Description : In the induction type directional over current relay, when a short-circuit occurs in the circuit (A) power flows in reverse direction (B) power flows in normal direction (C) directional power element does not operate (D) over current element is not energized

Last Answer : In the induction type directional over current relay, when a short-circuit occurs in the circuit power flows in reverse direction

Description : A solid state relay (A) withstands voltage transients (B) does not require auxiliary dc supply (C) provide low burden on CT and P (D) does not provide earth fault protection

Last Answer : A solid state relay provide low burden on CT and P

Last Answer : The torque produced in induction type relay (shaded pole structure) is inversely proportional to the square of the current.

Last Answer : Admittance relay is directional relay.

Last Answer : The relay with inverse time characteristic will operate within 5 to 10 sec.

Last Answer : Reactance relay is preferred for phase fault on short transmission line.

Last Answer : Induction cup relay is operated due to changes in current, voltage, impedance.

Last Answer : Interruption of large currents by relay requires arc suppressing blow out coils, wide separation of the opened contacts, high speed opening of contacts.

Last Answer : Overheating of relay contacts or contact born out is due to slow making and breaking of load circuit contacts, foreign matter on the contact surface, too low contact pressure.

Last Answer : A differential relay measures the vector difference between two or more similar electrical quantities.

Last Answer : Burden of a protective relay is the power absorbed by the circuit of relay.

Last Answer : In order that current should flow without causing excessive heating or voltage drop, the relay contacts should have low contact resistance, be clean and smooth, be of sufficient size and proper shape.

Last Answer : The relay operating speed depends upon the spring tension, the rate of flux built up, armature core air gap.

Description : How do relay works ?

Last Answer : Relay working like contact it is noise less 

Description : What is the use of Buchholz relay in transformer?

Last Answer : This is a transformer that is used to step up and down current. 

Description : What is the difference between a switch and a relay?

Last Answer : Switch is simply a mechanical contact mechanism and relay is a electromagnetic switch . Switch can be direct mechanically turn on and off but relay can be operated by energising coil .

Last Answer : Buchholz's relay gives warning and protection against electrical fault inside the transformer itself.

Description : Blind spot is a point in the zones of protection where

Last Answer : Blind spot is a point in the zones of protection where No protection is available.

Description : For protection of rotating machines against lightning surges _______ is used.  (1) lightning arrester (2) capacitor (3) combination of lightning arrester and capacitor (4) lightning conductor and arrester

Last Answer : For protection of rotating machines against lightning surges combination of lightning arrester and capacitor is used. 

Last Answer : Protection by fuses is generally not used beyond 100 A .

Last Answer : A fuse in a motor circuit provides protection against short-circuit and overload.

Last Answer : Overfluxing protection is recommended for generator transformer of the power plant.

Last Answer : Over voltage protection is recommended for hydro-electric generators, steam turbine generators, gas turbine generators.

Last Answer : Discrimination between main and back up protection is provided by the use of relays which are slow.

Last Answer : For the protection of power station buildings against direct strokes the requirements are interception, conduction and dissipation.

Last Answer : The delay fuses are used for the protection of motors.

Last Answer : A thermal protection switch can protect against overload.

Description : Primary and Backup Protection

Last Answer : Primary and Backup Protection  B,D,G,I are the primary protection. A,C,H,J are the backup protection. About 90% of faults are clear by Primary Protection. So ... ordinated backup (primary is at various station  and backup is at control room with computer)

Description : What is Phase sequence? Draw waveforms of 3 phase emf.

Last Answer : Phase sequence: It is the order in which the three phases reach their peak or maximum values. It is shown in below fig. the phase sequence is A-B-C (or R-Y-B). In the following waveforms, it is ... 120º, B- phase voltage attains its positive maximum value. So the phase sequence is R-Y-B. 

Description : State the use of:- (i) Clip-on-ammeter (ii) Phase sequence indicator

Last Answer : (i) Clip-on-ammeter: used for measurement of current in cables/lines in live conditions without disconnecting them.  (ii) Phase sequence indicator: To determine /find the phase sequence of 3 phase supply. 

Description : Describe with neat diagram phase sequence indicator.

Last Answer : Phase Sequence Indicator: There are two types of phase sequence indicators: (a) Rotating type phase sequence indicator (b) Static type phase sequence indicator (a) Rotating Type Phase Sequence ... of the supply is reversed or altered, then the lamp 1 will glow brighter than the lamp 2.

Description : State the application of phase sequence indicator; clip on ammeter, frequency meter & P.F. meter.

Last Answer : Phase Sequence Indicator:  1. For finding correct phase sequence of supply  2. For obtaining exact instant of parallel operation of alternators.  3. For obtaining reversal of rotation ...  4. In electroplating industries   5. In various processes industries for measuring power factor

Description : Define phase sequence of three phase supply with waveforms. What is normal phase sequence? Which 3 standard colours are used to denote the phase sequence?

Last Answer : It  is  sunnosoidal  sequence.

Description : The sequence components of current of a single-phase load connected to a 3-phase system are (A) equal positive and negative sequence components (B) equal positive, negative and zero sequence components (C) vector sum of sequence currents is zero (D) algebraic sum of sequence currents is zero

Last Answer : The sequence components of current of a single-phase load connected to a 3-phase system are equal positive, negative and zero sequence components

Description : Fuel Pump Relay

Last Answer : Some car owners immediately suspect a fuel pump failure when their cars stall. However, there are many other engine problems that may resemble a fuel pump failure, such as restricted fuel filters, smashed ... advisable to bring your car to the repair shop so that the whole engine can be checked.

Description : main parts of Relay

Last Answer : Coil, plunger, contacts, springs, connecting terminals and enclosure.

Description : Buchholz relay is used as a safety device with respect to which of the following? A) Audio transformers B) Oil filled power transformers C) Air core transformer D) None of these

Last Answer : Buchholz relay is used as a safety device with respect to which of the following? A) Audio transformers B) Oil filled power transformers C) Air core transformer D) None of these

Description : A reactance relay is (A) Voltage restrained directional relay (B) Directional restrained over-current relay (C) Voltage restrained over current relay (D) Directional restrained over voltage relay

Last Answer : A reactance relay is Directional restrained over-current relay