In a synchronous machine, if the field flux axis ahead of the armature field axis in the direction of rotation, the machine is operating as 

(1) synchronous motor (2) synchronous generator (3) asynchronous motor (4) asynchronous generator

1 Answer

Answer :

In a synchronous machine, if the field flux axis ahead of the armature field axis in the direction of rotation, the machine is operating as synchronous generator 

Related questions

Description : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole)  (A) has q -axis current only (B) has d -axis current only (C) has both d and q axis currents (D) cannot be divided between q and d axis currents

Last Answer : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole) has d -axis current only

Description : How can we reverse the direction of rotation of synchronous motor?

Last Answer : By reversing supply phase sequence we can reverse the direction of rotation of synchronous motor.

Last Answer : The direction of rotation of a D.C. series motor can be changed by interchanging field terminals.

Last Answer : The direction of rotation of universal motor can be reversed the by reversing the flow of current through either armature winding or field winding.

Description : The armature reaction in a synchronous generator supplying leading power factor load is (A) magnetizing (B) demagnetizing (C) demagnetizing and cross-magnetizing (D) magnetizing and cross-magnetizing

Last Answer : The armature reaction in a synchronous generator supplying leading power factor load is magnetizing and cross-magnetizing

Description : A 200 V DC machine supplies 20 A at 200 V as a generator. The armature resistance is 0.2 Ohm. If the machine is now operated as a motor at same terminal voltage and current but with the flux increased by 10%, the ratio of motor speed to generator speed is

Last Answer : A 200 V DC machine supplies 20 A at 200 V as a generator. The armature resistance is 0.2 Ohm. If the machine is now operated as a motor at same terminal voltage and current but with the flux increased by 10%, the ratio of motor speed to generator speed is 0.87

Description : The induced emf in the armature of a lap -wound four -pole dc machine having 100 armature conductors rotating at 600 rpm and with 1 Wb flux per pole is  (1) 1000V (2) 100V (3) 600V (4) 10,000V

Last Answer : The induced emf in the armature of a lap -wound four -pole dc machine having 100 armature conductors rotating at 600 rpm and with 1 Wb flux per pole is 1000V

Description : Aluminium is not used as winding wire for the armature of a dc machine because  (1) aluminium has low resistivity (2) a large winding space is taken by aluminium conductors and creates ... ) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper

Last Answer : Aluminium is not used as winding wire for the armature of a dc machine because  (2) a large winding space is taken by aluminium conductors and creates jointing problems (3) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper

Description : The direction of rotation of an inverter fed 3-phase ac motor is reversed by (A) a mechanical reversing switch (B) reversing the input dc link voltage (C) operating the inverter as a rectifier (D) changing the sequence of switching

Last Answer : The direction of rotation of an inverter fed 3-phase ac motor is reversed by changing the sequence of switching

Last Answer : In case of a shaded pole motor the direction of rotation of the motor is from main pole to shaded pole.

Last Answer : Direction of rotation of a split phase motor can be reversed by reversing the connection of either running winding or starting winding.

Last Answer : The direction of rotation of an hysteresis motor is determined by position of shaded pole with respect to main pole.

Last Answer : In repulsion motor direction of rotation of motor is the same as that of brush shift.

Description : It is possible to increase the field flux and, at the same time, increase the speed of a d.c. motor provided its .......... is held constant.

Last Answer : It is possible to increase the field flux and, at the same time, increase the speed of a d.c. motor provided its armature current is held constant.

Description : Torque angle for the synchronous machine is the angle between (A) stator magnetic field and rotor magnetic field (B) stator magnetic field and net magnetic field in the air gap (C) rotor magnetic field and net magnetic field in the air gap (D) excitation voltage and impedance voltage drop

Last Answer : Torque angle for the synchronous machine is the angle between rotor magnetic field and net magnetic field in the air gap

Last Answer : In a synchronous motor, the armature current has large values for high and low excitation.

Last Answer : The armature current of the synchronous motor has large values for low and high excitation.

Last Answer : Open circuited armature coil of a D.C. machine is identified by the scarring of the commutator segment to which open circuited coil is connected and indicated by a spark completely around the commutator.

Description : What is the direction of the induced electric field?

Last Answer : It  is  in  opposite  direction   to  the  one  that   produced  it.

Description : What is the direction of the electric field?

Last Answer : Electric   field    is  at   right angle   widh  flow  of  current  (right  hand   rule).

Last Answer : If the field winding of an unloaded salient pole synchronous motor is open circuited, the motor will stop.

Description : If the field of synchronous motor is under excited, power factor will be?

Last Answer : If the field of synchronous motor is under excited, power factor will be lagging.

Description : The 'Equal area criterion' for the determination of transient stability of a synchronous machine connected to an infinite bus  (1) ignores line as well as synchronous machine resistance ... consideration the possibility of machine losing synchronism after it has survived during the first swing.

Last Answer : 1

Description : During a disturbance on a synchronous machine, the rotor swings form A to B before finally setting down to steady state at point C on the power angle curve. The speed of the machine during oscillation is synchronous at point(s)

Last Answer : During a disturbance on a synchronous machine, the rotor swings form A to B before finally setting down to steady state at point C on the power angle curve. The speed of the machine during oscillation is synchronous at point(s) only at C

Last Answer : Synchronsizing power of a synchronous machine is inversely proportional to the synchronous reactance.

Last Answer : A synchronous machine with low value of short-circuit ratio has lower stability limit.

Description : If we change the excitation of synchronous machine will it affect on power factor?

Last Answer : Yes, If we change the excitation of synchronous machine it will affect on power factor. If the synchronous motor is overexcited then it will have leading power factor and if the motor is underexcited then it will have lagging power factor.

Description : If we change the excitation of synchronous machine will it affect on motor speed?

Last Answer : No, If we change the excitation of synchronous machine it will not affect on motor speed.

Description : V - curve of synchronous machine shows the relation between?

Last Answer : V - curve of synchronous machine shows the relation between AC armature current and DC field current.

Description : Why synchronous machine is called doubly excited machine?

Last Answer : Armature windings of synchronous machines either deliver 3 phase AC or absorb 3 phase AC source,  whereas field windings are energized from DC source. Thus due to presence of AC on armature and DC on field windings, synchronous machines are often referred as doubly excited machines.

Description : Which machine is the exciter of synchronous machine?

Last Answer : DC shunt machine is the exciter of synchronous machine.

Last Answer : To reverse the direction of rotation of a capacitor start motor while it is running we should disconnect motor from the supply till it stops then reconnect it to supply with reversed connection of main or auxiliary winding.

Description : In an induction motor if the flux density is reduced to one-half, of its normal value then the torque will  (1) reduce to one-half (2) reduce to one-fourth (3) remain unchanged (4) increase four times

Last Answer : In an induction motor if the flux density is reduced.to one-half, of its normal value then the torque will reduce to one-fourth

Description : The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is (A) 0.25 pu (B) 0.5 pu (C) 1.0 pu (D) 1.5 pu

Last Answer : The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is 0.5 pu

Description : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is

Last Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

Description : In dc machines, the armature windings are placed on the rotor because of the necessity for  (1) electromechanical energy conversion (2) generation of voltage (3) commutation (4) development of torque

Last Answer : 3  Commutation

Last Answer : The armature voltage control of D.C. motor provides constant torque drive.

Last Answer : The armature torque of the D.C. shunt motor is proportional to armature current.

Last Answer : In a D.C. shunt motor, under the conditions of maximum power, the current in the armature will be more than full-load current.

Last Answer : In a A.C. series motor armature coils are usually connected to commutator through resistance.

Description : Why is the armature of DC generator laminated?

Last Answer : The armature of DC generator is laminated to reduce eddy current losses.

Description : Armature control of DC motor

Last Answer : Armature control of DC motor

Description : how can we reverse the direction of rotation of three phase induction motor ?

Last Answer : The direction of rotation of three phase induction motor can be reversed by plugging i.e by changing any two out of three phases of the supply to the stator of the Induction motor terminal.

Last Answer : Advantages of vertical axis wind mills: 1. Simple blade design 2. Low cost of fabrication. 3. No yaw controller required. 4. Easy maintenance because ground mounted generator and gear box. 

Description : lf the poles of system are lying on the imaginary axis in s-plane, then the system will be

Last Answer : lf the poles of system are lying on the imaginary axis in s-plane, then the system will be marginally stable

Description : Center of gravity of a solid cone lies on the axis at the height?

Last Answer : Center of gravity of a solid cone lies on the axis at the height one-fourth of the total height above base.

Last Answer : In a D.C. generator the magnetic neutral axis coincides with the geometrical neutral axis, when there is no load on|he generator.

Last Answer : Armature reaction of an unsaturated D.C. machine is crossmagnetising.

Description : A sinusoidal voltage of 5 Hz is applied to the field of a shunt generator. The armature voltage wave?

Last Answer : A sinusoidal voltage of 5 Hz is applied to the field of a shunt generator. The armature voltage wave will be of 5 Hz.

Description : Damper winding in a synchronous motor

Last Answer : Damper winding in a synchronous motor Serves to start the motor.