A transmission line has 1 P.0 impedance on a base of 11 KV, 100 MVA. On a base of 55 KV. it will have a P.0 impedance of

1 Answer

Answer :

A transmission line has 1 P.0 impedance on a base of 11 KV, 100 MVA. On a base of 55 KV. it will have a P.0 impedance of 0.02 P.U

Related questions

Description : A 50Ω transmission line is terminated in an impedance of 20-j50. What will be the reflection coefficient? A) 0.69 B) 1.69 C) 6.9 D) 16.9 

Last Answer : A 50Ω transmission line is terminated in an impedance of 20-j50. What will be the reflection coefficient? A) 0.69 B) 1.69 C) 6.9 D) 16.9 

Description : The surge impedance for over head line is taken as  (1) 10-20 ohms (2) 50-60 ohms (3) 100-200 ohms (4) 1000-2000 ohms

Last Answer : The surge impedance for over head line is taken as 100-200 ohms

Description : Stability of a transmission line can be increased by

Last Answer : Stability of a transmission line can be increased by Shunt capacitor, Series capacitor

Description : In a transmission line if booster transformers are to be used, preferred location will be  (A) At the receiving end (B) At the sending end (C) At the intermediate point (D) Anywhere in the line 

Last Answer : In a transmission line if booster transformers are to be used, preferred location will be At the intermediate point

Description : The sending end and receiving end voltages of a three-phase transmission line are 10 kV/ph and 9.5 kV/ph, respectively. If the resistance drop is 150 V/ph and receiving end power factor is 0.8, the sending end power factor is (A) 0.745 lagging (B) 0.775 lagging (C) 0.8 lagging (D) 0.85 lagging

Last Answer : Vscos¢s-Vrcos¢r=IR

Description : For a short transmission line with r/x ratio of is 1.0, the regulation will be zero when the load power factor is

Last Answer : For a short transmission line with r/x ratio of is 1.0, the regulation will be zero when the load power factor is 0.707 lead

Description : State the limitations of EHVAC transmission line. 

Last Answer : Following are the Limitations of EHVAC Transmission:   1. Insulation cost increases as voltage increases 2. Skin effect is more 3. Proximity effect is more. 4. Corona loss increases. 5. Radio ... 18. EHVAC is economical only for bulk amount of power is to be transmitted over long distance. 

Description : State line parameters of transmission line. 

Last Answer : Following are the of Line parameters of transmission line:  1. Resistance  2. Inductance  3. Capacitance

Description : State the impact of inductance and resistance on transmission line performance

Last Answer : Impact of inductance on transmission line: 1) It causes IXL drop in transmission line which affects regulation. 2) It is the only parameter which decides power transmission capacity of line i. ... is very small, it causes losses, temperature rise& poor voltage regulation so it cannot be neglected

Description : effect of inductance and capacitance on performance of transmission line.

Last Answer : Following are the effect on performance of transmission line:  1. Due to inductance (L) voltage drop in transmission line produces.  2. Capacitor (C) draws charging current ... , transmission line efficiency, voltage regulation & also power factor of transmission line gets affected. 

Description : While calculating performance of medium transmission line, what assumptions are made in case of (i) Nominal 'T' Method (ii) Nominal 'TT' Method. 

Last Answer : (i) Assumptions are made in case of Nominal 'T' Method:  a. It is assume that line capacitance is connected at center of transmission line. b. It is assume that half ... assumed that transmission line resistance & reactance per phase is connected in between two half transmission line capacitance 

Description : HVDC transmission line in India: 

Last Answer : HVDC transmission line in India:  S.N .  From To  Voltage 1 Rihand (U.P) (from 1990) Dadri +- 500 KV (bipolar) 2 Talcher- is the biggest ... (Chandrapur) Western Region  140KV   8 Connecting Southern region(Vizag- Gajuwaka) Eastern Region 140KV 

Description : effect of line parameter on performance of transmission line. 

Last Answer : Following are the effect of line parameter on performance of transmission line:  1. Due to resistance (R), voltage drop in transmission line & copper losses in transmission line ... transmission line efficiency, voltage regulation & also power factor of transmission line gets affected. 

Description : Why is transmission line 11kV, 33kV 66kV Not Is 10kV, 20kV, 30kV ?

Last Answer : 10kv plus to compensate losses in olden days 1kv were added and transmitted. Since all equipment used for transmission have a multiple of 11 from olden days, still that is being followed even though the losses are ... voltages, multiples of 11 is eazy for winding ratios.. i.e. 11kv to 33kv is 1:3.

Description : The sag of a transmission line is least affected by (A) Self weight of the conductor. (B) Temperature of the surrounding air. (C) Current through the conductor. (D) Ice deposited on the conductor.

Last Answer : The sag of a transmission line is least affected by Current through the conductor.

Description : A transmission line of 200 km has a certain A, B, C and D parameters. If the length is reduced to 60 km

Last Answer : A transmission line of 200 km has a certain A, B, C and D parameters. If the length is reduced to 60 km A increases, B decreases

Description : Series capacitive compensation in EHV transmission line is used to

Last Answer : To maintain voltage stability 

Description : Transmission efficiency of a transmission line increases with the

Last Answer : Transmission efficiency of a transmission line increases with the increase in power factor and voltage

Last Answer : Reactance relay is preferred for phase fault on short transmission line.

Last Answer : When a wave propagates on a transmission line, it suffers reflection several times at sending and other end.

Last Answer : The interaction between a transmission line and communication line is minimized by transposing transmission as well as communication lines, increasing the height of the transmission line tower, increasing the distance between the two lines.

Last Answer : When a transmission line is energized, the wave that propagates on it is current wave and voltage wave.

Last Answer : A transmission line is protected by distance protection, time graded and current graded overcurrent protection.

Description : what is mean by medium transmission line ?

Last Answer : The transmission line which have length between 80 km to 250 km is known as medium transmission line.

Description : what is mean by short transmission line ?

Last Answer : The transmission lines which have length less than 80 km is known as short transmission lines.

Description : what is mean by long transmission line ?

Last Answer : The transmission line which have length more than 250 km are known as long transmission lines.

Description : Which of the following is true for a bus impedance matrix ?  (A) It is sparse  (B) It has diagonally dominant elements  (C) It is the inverse of the bus admittance matrix  (D) Each element of it is the reciprocal of the corresponding element in admittance matrix

Last Answer : Which of the following is true for a bus impedance matrix ?  (A) It is sparse  (B) It has diagonally dominant elements  (C) It is the inverse of the bus admittance matrix  (D) Each element of it is the reciprocal of the corresponding element in admittance matrix

Description : How many insulator disc used for 33 kV transmission voltage line?

Last Answer : 5,As 33kv is Vrms

Description : The rotor impedance of a slip ring induction motor is (0.1 + j0.6)Ohm/ ph . The resistance/ph to be inserted into rotor to get maximum torque at starting should be

Last Answer : The rotor impedance of a slip ring induction motor is (0.1 + j0.6)Ohm/ ph . The resistance/ph to be inserted into rotor to get maximum torque at starting should be 0.5 Ohm

Description : For transmission of power over a distance of 200 km, the transmission voltage should be (a) 132 kV (b) 66 kV (c) 33 kV (d) 11 kV

Last Answer : (a) 132 kV

Description : The per unit impedance of a circuit element is 0.30. If the base kV and base MVA are halved, then the new value of the per unit impedance of the circuit element will be:  (A) 0.3 (B) 0.6 (C) 0.003 (D) 0.006 

Last Answer : 3

Description : Define impedance diagram and reactance diagram.

Last Answer : Impedance diagram: Impedance diagram is the simplified equivalent circuits of single line or one line diagrams of power system in which all components are represented by their equivalent circuit.  ... machines are neglected and is used only for fault current calculation is called reactance diagram.

Description : A linear network has a current input 4cos(ω t + 20º)A and a voltage output 10 cos(ωt +110º) V. Determine the associated impedance.

Last Answer : Solution

Description : Give the effect of source impedance on converter operation.

Last Answer : Effect of source impedance on converter operation: For single-phase fully controlled bridge converter, the SCRs are triggered in pairs alternately. During positive half-cycle of input, SCRs T1 and T2 are triggered ... increases and as a consequence, the output dc voltage decreases. 

Description : Impedance ratio

Last Answer : Impedance ratio

Description : How to find total impedance Z, current I and Impedance angle ?

Last Answer : How to find total impedance Z, current I and Impedance angle ?

Description :  An independent voltage source in series with an impedance ZS=R+jXS delivers a maximum average power to a load impedance ZL when A) ZL = R B) ZL = jXS C) ZL = R-jXS D) ZL = R+jXS 

Last Answer :  An independent voltage source in series with an impedance ZS=R+jXS delivers a maximum average power to a load impedance ZL when ZL = R-jXS

Description : In a series resonant circuit, the impedance of the circuit is?

Last Answer : In a series resonant circuit, the impedance of the circuit is minimum.

Description : Is the input impedance of MOSFET more than BJT and FET?

Last Answer : Yes, the input impedance of MOSFET more than BJT and FET.

Description : For transmission of power over a distance of 500 km, the transmission voltage should be in the range (a) 150 to 220 kV (b) 100 to 120 kV (c) 60 to 100 kV (d) 20 to 50 kV

Last Answer : (a) 150 to 220 kV

Description : Transmission voltage of ll kV is normally used for distances upto (a) 20—25 km (b) 40—50 km (c) 60—70 km (d) 80—100 km

Last Answer : (a) 20—25 km

Description : For 11kV line the inductance per km per phase will be of the order of:  (A) 1 H (B) 0.1 H (C) 1 mH (D) 0.1 mH

Last Answer : For 11kV line the inductance per km per phase will be of the order of: 1 mH

Description : In which of the following transmission lines, the value of the Shunt admittance should be approximated to zero ? (A) A 66 kV 35 km long line (B) A 132 kV 200 km long line (C) A 220 kV 300 km long line (D) A 400 kV 500 km long line

Last Answer : In which of the following transmission lines, the value of the Shunt admittance should be approximated to zero ? (A) A 66 kV 35 km long line (B) A 132 kV 200 km long line (C) A 220 kV 300 km long line (D) A 400 kV 500 km long line

Description : In case the height of transmission tower is increased, which of the following parameter is likely to change?  (A) Resistance (B) Inductance (C) Capacitance (D) None of the above

Last Answer : In case the height of transmission tower is increased, which of the following parameter is likely to change?  (A) Resistance (B) Inductance (C) Capacitance (D) None of the above

Description : If 3000 kW power is to be transmitted over a distance of 30 km, the desirable transmission voltage will be.  (A) 11 kV (B) 33 kV (C) 66 kV (D) 132 kV

Last Answer : By

Description : The purpose of guard ring in transmission lines is to  (1) reduce the earth capacitance of the lowest unit. (2) increase the earth capacitance of the lowest unit. (3) reduce the transmission lines losses. (4) reduce the reactance of the line

Last Answer : The purpose of guard ring in transmission lines is to reduce the earth capacitance of the lowest unit.

Description : A 50 Hz, 4 pole turboalternator rated at 20 MVA. 13.2 KV has an inertia constant H = 4 KW sec/KVA. The K.E. stored in the rotor at synchronous speed is

Last Answer : A 50 Hz, 4 pole turboalternator rated at 20 MVA. 13.2 KV has an inertia constant H = 4 KW sec/KVA. The K.E. stored in the rotor at synchronous speed is 80 MJ

Description : Pin type insulators are generally not used for voltages beyond (a) 1 kV (b) 11 kV (c) 22 kV (d) 33 kV

Last Answer : (d) 33 kV

Description : Which of the following is usually not the generating voltage ? (a) 6.6 kV (b) 8.8 kV (c) 11 kV (d) 13.2 kV

Last Answer : (b) 8.8 kV

Description : Large industrial consumers are supplied electrical energy at (a) 400 V (b) 11 kV (c) 66 kV (d) 400 kV

Last Answer : (c) 66 kV