The permissible voltage variation in transmission and distribution system is: 

(A) ± 0.1% (B) ± 1% (C) ±10% (D) ± 25%

1 Answer

Answer :

The permissible voltage variation in transmission and distribution system is: ±10%

Related questions

Description : Explain following techniques related to energy conservation in transmission and distribution system. (i) By balancing phase currents (ii) Variable technical losses (I2R losses).

Last Answer : (i) Balancing Phase currents: Proper (healthy balanced) three phase loads always draw equal currents in all lines but single phase loads in the 3 phase 4 wire system or loads connected between two ... . 11) Minimize I2R losses. 12) Balance the load currents. 13) Regulate the system voltages.

Description : In voltage source converter based HVDC transmission system the active power is controlled by changing (A) phase angle of the converter ac input voltage (B) supply frequency of the converter ac input voltage (C) magnitude of the converter ac input voltage (D) DC voltage at the inverter terminals

Last Answer : In voltage source converter based HVDC transmission system the active power is controlled by changing phase angle of the converter ac input voltage

Description : TRANSMISSION AND DISTRIBUTION MCQ

Last Answer : 51. It is difficult to maintain oil filled cables. (a) Yes (b) No Ans: a 51. In capacitance grading a homogeneous dielectric is used. (a) Yes (b) No Ans: b 52. In congested areas where excavation is ... The metallic sheath may be made of lead or lead alloy or of aluminium. (a) Yes (b) No Ans: b

Description : Precise control of reactive current flow entering the transmission and distribution systems can be minimized by using (A) synchronous condenser (B) static VAR capacitor (C) capacitor bank (D) thyristor switched reactor in parallel with capacitor

Last Answer : Precise control of reactive current flow entering the transmission and distribution systems can be minimized by using (A) synchronous condenser (B) static VAR capacitor (C) capacitor bank (D) thyristor switched reactor in parallel with capacitor

Description : requirements of a distribution system

Last Answer : Following requirements of a distribution system.  1. Layout should be simple in design. 2. It should have less initial cost 3. The distribution system should have minimum distribution ... stability of existing distribution system. 15. Time required for completion of work should be less. 

Description : Why radial distribution system used for short distance ? 

Last Answer : Because of following disadvantages radial distribution system is not used for long distance:  Since there is only one feeder to DTC feed at one point so, 1) There is no reliability ... more time for fault finding & repairing Hence radial distribution system is used for short distance.

Description : Grid distribution system

Last Answer : Grid distribution system:-  In this system, when the feeder or loop or ring is charged (energized) by two or more than two substations from two or more than two different generating stations then it is known as “Grid distribution system. In this system only one feeder is utilized at a time. 

Description : Define: primary and secondary distribution system 

Last Answer : i) Primary Distribution:  It is a 3-phase, 3-wire transmission line connected in between receiving substation to Distribution substation. OR It is link between receiving substation & ... substation to consumer line. OR It is link between distribution transformer substation & consumer. 

Description : State the losses in secondary distribution system. 

Last Answer : The losses in secondary distribution system: a) Technical losses: 1. Due to poor voltage 2. Due to unbalance load 3. Due poor quality of transformer & its components 4. Due to poor quality ... of induction type of energy meter. 3. Lack of administration. 4. Energy theft 5. Unmetered supply

Description : The main criterion for selection of the size of a radial distribution system is

Last Answer : The main criterion for selection of the size of a radial distribution system is voltage drop

Last Answer : In a distribution system, in order to improve power factor, the synchronous capacitors are installed at the receiving end.

Description : A 3-phase 4 wire system is commonly used on (a) primary transmission (b) secondary transmission (c) primary distribution (d) secondary distribution

Last Answer : (d) secondary distribution

Description : What is the permissible flux density in case of cold rolled grained oriented steel?

Last Answer : The permissible flux density in case of cold rolled grained oriented steel is 1.7 Wb/m2.

Description : Which of the following materials is not used for transmission and distribution of electrical power ? (a) Copper (b) Aluminium (c) Steel (d) Tungsten

Last Answer : (d) Tungsten

Description : Constant voltage transmission entails the following disadvantage (a) large conductor area is required for same power transmission (b) short-circuit current of the system is increased (c) either of the above (d) none of the above

Last Answer : (b) short-circuit current of the system is increased

Description : Which of the following is the demerit of a 'constant voltage transmission system' ? (a) Increase of short-circuit current of the system (b) Availability of steady voltage at all loads at ... of carrying increased power for a given conductor size in case of long-distance heavy power transmission

Last Answer : (a) Increase of short-circuit current of the system

Description : Which of the following equipment, for regulating the voltage in distribution feeder, will be most economical ? (a) Static condenser (b) Synchronous condenser (c) Tap changing transformer (d) Booster transformer

Last Answer : (d) Booster transformer

Description : For transmission of power over a distance of 500 km, the transmission voltage should be in the range (a) 150 to 220 kV (b) 100 to 120 kV (c) 60 to 100 kV (d) 20 to 50 kV

Last Answer : (a) 150 to 220 kV

Description : For transmission of power over a distance of 200 km, the transmission voltage should be (a) 132 kV (b) 66 kV (c) 33 kV (d) 11 kV

Last Answer : (a) 132 kV

Description : The voltage drop, for constant voltage transmission is compensated by installing (a) inductors (b) capacitors (c) synchronous motors (d) all of above (e) none of the above

Last Answer : (c) synchronous motors

Description : Transmission voltage of ll kV is normally used for distances upto (a) 20—25 km (b) 40—50 km (c) 60—70 km (d) 80—100 km

Last Answer : (a) 20—25 km

Description : High voltage transmission lines use (a) suspension insulators (b) pin insulators (c) both (a) and (b) (d) none of the above

Last Answer : (a) suspension insulators

Description : Most of the high voltage transmission lines in India are (a) underground (b) overhead (c) either of the above (d) none of the above

Last Answer : (b) overhead

Description : State the advantages of use of high voltage in transmission of Electric power. 

Last Answer : Advantages: 1. As Transmission voltage increases, current decreases. 2. As current decreases, cross section of conductor decreases. 3. As cross section of conductor decreases, its ... high voltage transmission line, successful interconnection of transmission line is possible than low voltage. 

Description : The voltage of transmission can be regulated by  (A) Use of tap changing transformers (B) Switching in shunt capacitors at the receiving end during heavy loads (C) Use of capacitors to neutralize the effect of series reactance (D) Any of the above methods

Last Answer : The voltage of transmission can be regulated by  (A) Use of tap changing transformers (B) Switching in shunt capacitors at the receiving end during heavy loads (C) Use of capacitors to neutralize the effect of series reactance (D) Any of the above methods

Description : If 3000 kW power is to be transmitted over a distance of 30 km, the desirable transmission voltage will be.  (A) 11 kV (B) 33 kV (C) 66 kV (D) 132 kV

Last Answer : By

Description : What is meant by extra high voltage transmission?

Last Answer : HT & LT  two types transmission in industrial line 

Description : Why high voltage is used in power transmission?

Last Answer : The primary reason that power is transmitted at high voltages is to increase efficiency. ... The lower current that accompanies high voltage transmissionreduces resistance in the conductors aselectricity flows ... This means that thin, light-weight wires can beused in long-distance transmission.

Description : What are the advantages of high voltage transmission?

Last Answer : Advantages:  1. As Transmission voltage increases, current decreases. 2. As current decreases, cross section of conductor decreases. 3. As cross section of conductor decreases ... line increases  12. As transmission voltage increases power handling capacity of transmission line increases 

Description : If a 5-bus test system contains 6 transmission lines and one transformer, how many non-zero elements are there in the system Y-bus ? (A) 25 (B) 12 (C) 11 (D) 19

Last Answer : If a 5-bus test system contains 6 transmission lines and one transformer, 19 non-zero elements are there in the system Y-bus.

Last Answer : Ungrounded neutral transmission system is not recommended because of system insulation being overstressed due to over voltages, insulation overstress may lead to failure and subsequent phase to phase faults, being inadequately protected against ground fault.

Description : Which of the following is the least expensive protection for over current in low voltage system?  (A) Rewireable fuse (B) Isolator (C) Oil Circuit breaker (D) Air break circuit breaker

Last Answer : Which of the following is the least expensive protection for over current in low voltage system?  (A) Rewireable fuse (B) Isolator (C) Oil Circuit breaker (D) Air break circuit breaker

Description : A single core cable is designed to work for a single phase system with a peak voltage of 220 kV. The maximum permissible stress in the dielectric is not to exceed 20 kV/mm. For economical size, the overall core diameter of the cable is (A) 28.2 mm (B) 26.4 mm (C) 24.4 mm (D) 22.0 mm

Last Answer : A single core cable is designed to work for a single phase system with a peak voltage of 220 kV. The maximum permissible stress in the dielectric is not to exceed 20 kV/mm. For economical size, the overall core diameter of the cable is 22.0 mm

Description : Which of the following distribution systems is more reliable ? (a) Radial system (b) Tree system (c) Ring main system (d) All are equally reliable

Last Answer : (c) Ring main system

Description : Which of the following D.C. distribution system is the simplest and lowest in first cost ? (a) Radial system (b) Ring system (c) Inter-connected system (d) None of the above

Last Answer : (a) Radial system

Description : Explain some of the methods to improve the strength of transmission system?

Last Answer :  Introducing or adding of new transmission lines in to the system to avoid the overloading of the existing lines  Application of devices such as series capacitors in the right location of ... system  Adoption of multi-voltage levels an multi-circuits in the existing ac transmission system

Description : A feeder, in a transmission system, feeds power to (a) distributors (b) generating stations (c) service mains (d) all of the above

Last Answer : (a) distributors

Description : Distribution lines in India generally use (a) wooden poles (b) R.C.C. poles (c) steel towers (d) none of the above

Last Answer : (b) R.C.C. poles

Description : are the conductors, which connect the consumer's terminals to the distribution (a) Distributors (b) Service mains (c) Feeders (d) None of the above

Last Answer : (b) Service mains

Description : What are the factors that limit the maximum power transfer capability in a transmission line?

Last Answer : Answer: Some of the factors which limits the maximum power transfer are: 1. Electrical phase shift 2. Voltage drop 3. Thermal effects in the line

Description : What are the problems associated with EHV transmission?

Last Answer : Answer: The problems associated with EHV transmission are corona loss and radio interference, requirement of heavy supporting structures and insulation requirments

Description : What is the material used for overhead transmission lines?

Last Answer : Answer: ACSR conductors are employed.

Description : What for series and shunt compensation provided in EHV transmission lines?

Last Answer : Answer: Series capacitance is provided in EHV lines to artificially reduce the series reactance of the line so as to improve stability, voltage regulation and transmission efficiency Shunt compensation ... reduce the line susceptance so as to improve the voltage regulation under light load condition

Description : Series capacitors on transmission lines are of little use when the load VAR requirement is (a) large (b) small (b) fluctuating (d) any of the above

Last Answer : (b) small

Description : In the analysis of which of the following lines shunt capacitance is neglected ? (a) Short transmission lines (b) Medium transmission lines (c) Long transmission lines (d) Medium as well as long transmission lines

Last Answer : (a) Short transmission lines

Description : Which of the following characteristics should the line supports for transmission lines possess ? (a) Low cost (b) High mechanical strength (c) Longer life (d) All of the above

Last Answer : (d) All of the above

Description : Which of the following relays is used on long transmission lines ? (a) Impedance relay (b) Mho's relay (c) Reactance relay (d) None of the above

Last Answer : (b) Mho's relay

Description : Which of the following materials is used for overhead transmission lines ? (a) Steel cored aluminium (b) Galvanised steel (c) Cadmium copper (d) Any of the above

Last Answer : (d) Any of the above

Description : Transmission line insulators are made of (a) glass (b) porcelain (c) iron (d) P.V.C.

Last Answer : B

Description : In transmission lines the cross-arms are made of (a) copper (b) wood (c) R.C.C. (d) steel

Last Answer : (d) steel