In a transmission line if booster transformers are to be used, preferred location will be 

(A) At the receiving end (B) At the sending end (C) At the intermediate point (D) Anywhere in the line 

1 Answer

Answer :

In a transmission line if booster transformers are to be used, preferred location will be At the intermediate point

Related questions

Description : Stability of a transmission line can be increased by

Last Answer : Stability of a transmission line can be increased by Shunt capacitor, Series capacitor

Description : A transmission line has 1 P.0 impedance on a base of 11 KV, 100 MVA. On a base of 55 KV. it will have a P.0 impedance of

Last Answer : A transmission line has 1 P.0 impedance on a base of 11 KV, 100 MVA. On a base of 55 KV. it will have a P.0 impedance of 0.02 P.U

Last Answer : Reactance relay is preferred for phase fault on short transmission line.

Description : State the limitations of EHVAC transmission line. 

Last Answer : Following are the Limitations of EHVAC Transmission:   1. Insulation cost increases as voltage increases 2. Skin effect is more 3. Proximity effect is more. 4. Corona loss increases. 5. Radio ... 18. EHVAC is economical only for bulk amount of power is to be transmitted over long distance. 

Description : State line parameters of transmission line. 

Last Answer : Following are the of Line parameters of transmission line:  1. Resistance  2. Inductance  3. Capacitance

Description : State the impact of inductance and resistance on transmission line performance

Last Answer : Impact of inductance on transmission line: 1) It causes IXL drop in transmission line which affects regulation. 2) It is the only parameter which decides power transmission capacity of line i. ... is very small, it causes losses, temperature rise& poor voltage regulation so it cannot be neglected

Description : effect of inductance and capacitance on performance of transmission line.

Last Answer : Following are the effect on performance of transmission line:  1. Due to inductance (L) voltage drop in transmission line produces.  2. Capacitor (C) draws charging current ... , transmission line efficiency, voltage regulation & also power factor of transmission line gets affected. 

Description : While calculating performance of medium transmission line, what assumptions are made in case of (i) Nominal 'T' Method (ii) Nominal 'TT' Method. 

Last Answer : (i) Assumptions are made in case of Nominal 'T' Method:  a. It is assume that line capacitance is connected at center of transmission line. b. It is assume that half ... assumed that transmission line resistance & reactance per phase is connected in between two half transmission line capacitance 

Description : HVDC transmission line in India: 

Last Answer : HVDC transmission line in India:  S.N .  From To  Voltage 1 Rihand (U.P) (from 1990) Dadri +- 500 KV (bipolar) 2 Talcher- is the biggest ... (Chandrapur) Western Region  140KV   8 Connecting Southern region(Vizag- Gajuwaka) Eastern Region 140KV 

Description : effect of line parameter on performance of transmission line. 

Last Answer : Following are the effect of line parameter on performance of transmission line:  1. Due to resistance (R), voltage drop in transmission line & copper losses in transmission line ... transmission line efficiency, voltage regulation & also power factor of transmission line gets affected. 

Description : Why is transmission line 11kV, 33kV 66kV Not Is 10kV, 20kV, 30kV ?

Last Answer : 10kv plus to compensate losses in olden days 1kv were added and transmitted. Since all equipment used for transmission have a multiple of 11 from olden days, still that is being followed even though the losses are ... voltages, multiples of 11 is eazy for winding ratios.. i.e. 11kv to 33kv is 1:3.

Description : A 50Ω transmission line is terminated in an impedance of 20-j50. What will be the reflection coefficient? A) 0.69 B) 1.69 C) 6.9 D) 16.9 

Last Answer : A 50Ω transmission line is terminated in an impedance of 20-j50. What will be the reflection coefficient? A) 0.69 B) 1.69 C) 6.9 D) 16.9 

Description : The sag of a transmission line is least affected by (A) Self weight of the conductor. (B) Temperature of the surrounding air. (C) Current through the conductor. (D) Ice deposited on the conductor.

Last Answer : The sag of a transmission line is least affected by Current through the conductor.

Description : For a short transmission line with r/x ratio of is 1.0, the regulation will be zero when the load power factor is

Last Answer : For a short transmission line with r/x ratio of is 1.0, the regulation will be zero when the load power factor is 0.707 lead

Description : A transmission line of 200 km has a certain A, B, C and D parameters. If the length is reduced to 60 km

Last Answer : A transmission line of 200 km has a certain A, B, C and D parameters. If the length is reduced to 60 km A increases, B decreases

Description : Series capacitive compensation in EHV transmission line is used to

Last Answer : To maintain voltage stability 

Description : The sending end and receiving end voltages of a three-phase transmission line are 10 kV/ph and 9.5 kV/ph, respectively. If the resistance drop is 150 V/ph and receiving end power factor is 0.8, the sending end power factor is (A) 0.745 lagging (B) 0.775 lagging (C) 0.8 lagging (D) 0.85 lagging

Last Answer : Vscos¢s-Vrcos¢r=IR

Description : Transmission efficiency of a transmission line increases with the

Last Answer : Transmission efficiency of a transmission line increases with the increase in power factor and voltage

Last Answer : When a wave propagates on a transmission line, it suffers reflection several times at sending and other end.

Last Answer : The interaction between a transmission line and communication line is minimized by transposing transmission as well as communication lines, increasing the height of the transmission line tower, increasing the distance between the two lines.

Last Answer : When a transmission line is energized, the wave that propagates on it is current wave and voltage wave.

Last Answer : A transmission line is protected by distance protection, time graded and current graded overcurrent protection.

Description : what is mean by medium transmission line ?

Last Answer : The transmission line which have length between 80 km to 250 km is known as medium transmission line.

Description : what is mean by short transmission line ?

Last Answer : The transmission lines which have length less than 80 km is known as short transmission lines.

Description : what is mean by long transmission line ?

Last Answer : The transmission line which have length more than 250 km are known as long transmission lines.

Description : Covid 19 vaccines in Switzerland. Are they experimenting on the older people?

Last Answer : I’m sorry, I don’t understand your question.

Description : How many insulator disc used for 33 kV transmission voltage line?

Last Answer : 5,As 33kv is Vrms

Description : For 11kV line the inductance per km per phase will be of the order of:  (A) 1 H (B) 0.1 H (C) 1 mH (D) 0.1 mH

Last Answer : For 11kV line the inductance per km per phase will be of the order of: 1 mH

Description : In which of the following transmission lines, the value of the Shunt admittance should be approximated to zero ? (A) A 66 kV 35 km long line (B) A 132 kV 200 km long line (C) A 220 kV 300 km long line (D) A 400 kV 500 km long line

Last Answer : In which of the following transmission lines, the value of the Shunt admittance should be approximated to zero ? (A) A 66 kV 35 km long line (B) A 132 kV 200 km long line (C) A 220 kV 300 km long line (D) A 400 kV 500 km long line

Description : In case the height of transmission tower is increased, which of the following parameter is likely to change?  (A) Resistance (B) Inductance (C) Capacitance (D) None of the above

Last Answer : In case the height of transmission tower is increased, which of the following parameter is likely to change?  (A) Resistance (B) Inductance (C) Capacitance (D) None of the above

Description : If 3000 kW power is to be transmitted over a distance of 30 km, the desirable transmission voltage will be.  (A) 11 kV (B) 33 kV (C) 66 kV (D) 132 kV

Last Answer : By

Description : The purpose of guard ring in transmission lines is to  (1) reduce the earth capacitance of the lowest unit. (2) increase the earth capacitance of the lowest unit. (3) reduce the transmission lines losses. (4) reduce the reactance of the line

Last Answer : The purpose of guard ring in transmission lines is to reduce the earth capacitance of the lowest unit.

Description : 74)Power transformers are generally designed to have maximum efficiency around A. No load B. Half load C. Near full load D. 10% overload

Last Answer : C. Near full load

Description : [23] Transformers are rated in KVA instead of KW because A. load power factor is often not known B. KVA is fixed whereas KW depends on load power factor C. Total transformer loss depends on volt ampere D. It has become customary

Last Answer : C. Total transformer loss depends on volt ampere

Description : TRANSFORMERS MCQ

Last Answer : 101. A shell-type transformer has (a) high eddy current losses (b) reduced magnetic leakage (c) negligibly hysteresis losses (d) none of the above Ans: b 102. A transformer can have regulation closer to zero (a ... (6) much smaller (c) much higher (d) somewhat smaller (e) none of the above Ans: c

Description : What are the schedules of maintenance done on transformers?

Last Answer : Ans. Following are the schedules of maintenance on transformers. a. Daily maintenance. b. Monthly maintenance. c. Quarterly maintenance. d. Half yearly maintenance. e. Yearly maintenance. f. 5 Yearly maintenance.

Description : Why a transformer requires cooling. What are the methods of cooling transformers?

Last Answer : Ans. Transformers requires cooling as they get heated up due to various losses taking place in the transformer. (like iron of copper losses) Following are the methods of cooling of transformer. a. Natural ... . Forced oil air Natural Cooling (OFAN). d. Forced oil and forced Air cooling (OFAF).

Description : What are the loses in Transformers, Explain?

Last Answer : Ans. (1) Iron loses (2) Copper loses Iron Loss : Iron loss occurs in the transformers Iron core due to hysteresis and eddy currents taking place. They are almost fixed irrespective of ... losses in the primary and the secondary windings of the transformer which with the loading of transformer.

Description : Classify the transformers based on the construction, frequency and power.

Last Answer : Classification of Transformer Based On: i) Construction: Shell type, Core type, Berry type ii) Change in voltage level: Step-Up, Step-Down, iii) Number of phases: Single phase, Three phase iv) ... Control vi) Cooling: Self-cooled, Air-cooled, Forced-air cooled, Oil-cooled, Forced-oil cooled. 

Description : Which of the following connection of transformers will give highest value of secondary voltage ? (A) Delta primary delta secondary (B) Delta primary star secondary (C) Star primary star secondary (D) Star primary delta secondary

Last Answer : Which of the following connection of transformers will give highest value of secondary voltage ? (A) Delta primary delta secondary (B) Delta primary star secondary (C) Star primary star secondary (D) Star primary delta secondary

Description : Two transformers A and B having equal outputs and voltage ratios but unequal percentage impedances of 4 and 2 are operating in parallel. The transformer A will be overloaded by 

Last Answer : Two transformers A and B having equal outputs and voltage ratios but unequal percentage impedances of 4 and 2 are operating in parallel. The transformer A will be overloaded by 33%

Description : Core type transformers are popular in___________.  (A) High voltage applications (B) Low voltage applications (C) All of the above (D) None of the above

Last Answer : Core type transformers are popular in High voltage applications

Description : The friction losses in Real Transformers are :  (A) 0% (B) 5% (C) 25% (D) 50%

Last Answer : A

Description : Two 3-phase transformers cannot be operated in parallel, if their :  (A) kVAs are different (B) phase sequences are different (C) % impedances are different (D) voltage ratios are different

Last Answer : Two 3-phase transformers cannot be operated in parallel, if their : phase sequences are different

Description : An additional condition for parallel operation of three-phase transformers over single-phase transformers is that

Last Answer : An additional condition for parallel operation of three-phase transformers over single-phase transformers is that the transformers should belong to the same vector group

Description : Which of the following is the advantage of using CRGO steel in transformers? A) High magnetic flux density B) Low permeability C) Both A and B D) None of these

Last Answer : It definitely High Magnetic Flux Density since a crgo steel has always a more around 3% of silicon proportion among the remaining ferrite which make cold rolled grain oriented steel having high flux magnetic ... for more about the crgo core you can learn here https://nicoreindia.com/crgo-core/

Last Answer : Instrument transformers are potential transformers, current transformers.

Last Answer : Natural oil cooling is used for transformers up to a rating of 3000 kVA.

Description : If the percentage impedances of the two transformers working in parallel are different, then?

Last Answer : If the percentage impedances of the two transformers working in parallel are different, then parallel operation will still be possible, but the power factors at which the two transformers operate will be different from the power factor of the common load.