Damper winding in a synchronous motor

1 Answer

Answer :

Damper winding in a synchronous motor Serves to start the motor.

Related questions

Description : Damper winding is provided in 3 phase synchronous motors to :

Last Answer : Damper winding is provided in 3 phase synchronous motors to : provide starting torque and prevent hunting

Last Answer : Centrifugal switch disconnects the auxiliary winding of the motor at about 70 to 80 percent of synchronous speed.

Description : In synchronous motor, does the winding losses vary with load?

Last Answer : No, in the synchronous motor the winding losses do not vary with load.

Last Answer : If the field winding of an unloaded salient pole synchronous motor is open circuited, the motor will stop.

Description : The damping winding in synchronous motor is generally used to?

Last Answer : The damping winding in synchronous motor is generally used to provide starting torque and prevent hunting.

Description : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is

Last Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

Last Answer : The starting winding of a single-phase motor is placed in stator.

Last Answer : If starting winding of a single-phase induction motor is left in the circuit, it will draw excessive current and overheat.

Last Answer : Starting winding of a single phase motor of a refrigerator is disconnected from the circuit by means of a magnetic relay.

Last Answer : The purpose of stator winding in the compensated repulsion motor is to improve power factor and provide better speed regulation.

Last Answer : In split phase motor main winding is of thick wire placed at the bottom of the slots.

Description : The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is (A) 0.25 pu (B) 0.5 pu (C) 1.0 pu (D) 1.5 pu

Last Answer : The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is 0.5 pu

Description : The effect of increasing load on a synchronous motor running with normal excitation is (A) Increase both its Ia and power factor. (B) Decrease Ia, but increase power factor. (C) Increase Ia, but decrease power factor (D) Decrease both Ia and power factor.

Last Answer : The effect of increasing load on a synchronous motor running with normal excitation is Increase Ia, but decrease power factor

Description : A three-phase synchronous motor connected to ac mains is running at full load and unity power factor. lf its shaft load is reduced by half and field current is held constant then its new power factor will be

Last Answer : Leading

Last Answer : In case of a reluctance motor, when the load is increased so that it cannot maintain synchronous speed the motor will run as induction motor.

Last Answer : If the centrifugal switch does not open at 70 to 80 percent of synchronous speed of motor, it would result in damage to the starting winding.

Last Answer : Yes, we can make the power factor of synchronous motor leading by adjusting its excitation.

Description : what is the difference between synchronous and asynchronous motor?

Last Answer : Asynchronous motors and syncrouns motor are called as dc machines.  and also syncrouns motor called as induction motor. Asynonymous motor as are rotates with constant speed we not able to operate . ... It is able to operate. These are a small difference between syncrouns and asynchronous motors. 

Last Answer : In A.C. series motor compensating winding is employed to reduce sparking at the brushes.

Last Answer : In split-phase motor auxiliary winding is of thin wire placed at the top of the slots.

Description : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be?

Last Answer : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be at the slot edge where coil enters or comes out of the slot.

Last Answer : A centrifugal switch is used to disconnect starting winding when motor has picked up about 50 to 70 per cent of rated speed.

Last Answer : In a capacitor start motor, the phase displacement between starting and running winding can be nearly 90°.

Last Answer : In a split phase motor, the running winding should have low resistance and high inductance.

Description : List different starting methods of three phase synchronous motor. Explain any one of them.

Last Answer : Different Starting Methods of Three Phase Synchronous Motor: As synchronous motor is not self starting, different methods of starting are as follows: 1) By using an Induction (Pony) motor 2) ... . The rotor gets pulled into synchronism and starts running at constant speed as a synchronous motor. 

Description : Draw and explain V and inverted V curves for synchronous motor.

Last Answer : V curves' and inverted V curves' for Synchronous Motor:  V curve:  V curve is a plot of the stator current versus field current for different constant loads. The graph is plotted ... Vcurves of synchronous motor. The highest point on each of these curves indicates unity power factor.

Description : List different torques in synchronous motor. 

Last Answer : Different Torques in Synchronous Motor: 1) Starting torque 2) Running torque 3) Pull-in torque 4) Pull-out torque

Description : In a self-controlled synchronous motor fed from a variable frequency inverter  (1) the rotor poles invariably have damper windings  (2) there are stability problems  (3) the speed of the rotor decides stator frequency  (4) the frequency of the stator decides the rotor speed

Last Answer : 2

Last Answer : Slip-rings in a synchronous motor carry direct current.

Last Answer : The efficiency of a properly designed synchronous motor will usually fall in range 85 to 95%.

Description : A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because?

Last Answer : A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because stator supply is not required to produce magnetic field.

Last Answer : A synchronous motor running with normal excitation adjusts to load increases essentially by increase in armature current.

Last Answer : The operating speed of a synchronous motor can be changed to new fixed value by changing frequency.

Last Answer : A synchronous motor can develop synchronous torque at synchronous speed.

Last Answer : In case one phase of a three-phase synchronous motor is short-circuited the motor will not start.

Last Answer : In a synchronous motor, the armature current has large values for high and low excitation.

Last Answer :  The size of a synchronous motor decreases with the increase in flux density.

Last Answer : The duration of sudden short-circuit test on a synchronous motor is usually about one second.

Description : The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as?

Last Answer : The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as pull-in torque.

Last Answer : The construction of a synchronous motor resembles an alternator.

Last Answer : The coupling angle or load angle of synchronous motor is defined as the angle between the rotor and the stator poles of opposite polarity.

Last Answer : If the synchronous motor, properly synchronised to the supply is running on no load and is having negligible loss then the stator current will be zero.

Last Answer : The armature current of the synchronous motor has large values for low and high excitation.

Last Answer : An over excited synchronous motor on noload is known as synchronous condenser.

Description : Which motor have more efficiency, synchronous motor or induction motor?

Last Answer : Synchronous motor has more efficiency.

Description : If we change the excitation of synchronous machine will it affect on motor speed?

Last Answer : No, If we change the excitation of synchronous machine it will not affect on motor speed.

Description : How can we reverse the direction of rotation of synchronous motor?

Last Answer : By reversing supply phase sequence we can reverse the direction of rotation of synchronous motor.

Description : What is the maximum value of torque angle in synchronous motor?

Last Answer : The maximum value of torque angle in synchronous motor is 90 degrees electrical.

Description : If the load of the normally excited synchronous motor is increased the power factor will?

Last Answer : If the load of the normally excited synchronous motor is increased the power factor will become lagging.

Description : Hunting in synchronous motor cannot be due to?

Last Answer : Hunting in synchronous motor cannot be due to windage friction.