In which of the following transmission lines, the value of the Shunt admittance should be approximated to zero ?

(A) A 66 kV 35 km long line (B) A 132 kV 200 km long line

(C) A 220 kV 300 km long line (D) A 400 kV 500 km long line

1 Answer

Answer :

In which of the following transmission lines, the value of the Shunt admittance should be approximated to zero ?

(A) A 66 kV 35 km long line (B) A 132 kV 200 km long line

(C) A 220 kV 300 km long line (D) A 400 kV 500 km long line

Related questions

Description : The purpose of guard ring in transmission lines is to  (1) reduce the earth capacitance of the lowest unit. (2) increase the earth capacitance of the lowest unit. (3) reduce the transmission lines losses. (4) reduce the reactance of the line

Last Answer : The purpose of guard ring in transmission lines is to reduce the earth capacitance of the lowest unit.

Description : State the effects of low power factor on efficiency and voltage regulation of short transmission lines. 

Last Answer : i) Effect of Low power factor on efficiency:- When power factor of load reduces current drawn by transmission line increases so copper losses in transmission line increases, hence transmission ... increases, so voltage drop in transmission line increases so regulation increases. (Become Poor) 

Description : State the classification of transmission lines depending on length of transmission lines. 

Last Answer : A) According to Voltage level: ( 2 Marks)  a) High voltage Transmission Line (HV) up to 33 KV  b) Extra High Voltage Transmission Line (EHV) above 33 KV up to 400 KV  c) Ultra ... Transmission Line: - The length of Long transmission Line is above 200KM and its line voltage is above 100KV

Description : Why are overhead transmission lines not insulated?

Last Answer : Insulators are useful to help separate electrical conductors when they come into physical contact. Overhead Transmission Lines Are Not Insulated: The overhead transmission line is carrying extreme high voltage and ... a whole lot of thick insulation to absorb the heat produced by such high voltage.

Description : Corona loss in transmission lines can be reduced by (A) using small diameter conductors (B) using bundled conductors (C) using less spacing between conductors (D) increasing the transmission line voltage

Last Answer : Corona loss in transmission lines can be reduced by using bundled conductors

Description : If a 5-bus test system contains 6 transmission lines and one transformer, how many non-zero elements are there in the system Y-bus ? (A) 25 (B) 12 (C) 11 (D) 19

Last Answer : If a 5-bus test system contains 6 transmission lines and one transformer, 19 non-zero elements are there in the system Y-bus.

Last Answer : Series capacitors on transmission lines are of little use when the load VAR requirement is small.

Description : Define admittance and state its unit.

Last Answer : Admittance is defined as the ability of the circuit to carry (admit) alternating current through it.  OR  It is the reciprocal of impedance Z. i.e Admittance Y = 1/Z.  Unit: Its unit is siemen (S) or mho (Ʊ).

Description : The diagonal elements of a nodal admittance matrix are strengthened by adding :  (A) Shunt capacitors (C) Generators (B) Shunt inductances (D) Resistive loads

Last Answer : A

Description : Which of the following is the SI unit for admittance? A) Ohm B) Henry C) Farad D) Siemens

Last Answer : Which of the following is the SI unit for admittance? A) Ohm B) Henry C) Farad D) Siemens

Last Answer : Admittance relay is directional relay.

Description : what is the reciprocal of admittance?

Last Answer : impedance is the reciprocal of admittance.

Description : The square root of the ratio of line impedance and shunt admittance is called the (a) surge impedance of the line (b) conductance of the line (c) regulation of the line (d) none of the above

Last Answer : (a) surge impedance of the line

Description : What for series and shunt compensation provided in EHV transmission lines?

Last Answer : Answer: Series capacitance is provided in EHV lines to artificially reduce the series reactance of the line so as to improve stability, voltage regulation and transmission efficiency Shunt compensation ... reduce the line susceptance so as to improve the voltage regulation under light load condition

Description : In the analysis of which of the following lines shunt capacitance is neglected ? (a) Short transmission lines (b) Medium transmission lines (c) Long transmission lines (d) Medium as well as long transmission lines

Last Answer : (a) Short transmission lines

Description : Stability of a transmission line can be increased by

Last Answer : Stability of a transmission line can be increased by Shunt capacitor, Series capacitor

Description : In a transmission line if booster transformers are to be used, preferred location will be  (A) At the receiving end (B) At the sending end (C) At the intermediate point (D) Anywhere in the line 

Last Answer : In a transmission line if booster transformers are to be used, preferred location will be At the intermediate point

Description : In case the height of transmission tower is increased, which of the following parameter is likely to change?  (A) Resistance (B) Inductance (C) Capacitance (D) None of the above

Last Answer : In case the height of transmission tower is increased, which of the following parameter is likely to change?  (A) Resistance (B) Inductance (C) Capacitance (D) None of the above

Description : If 3000 kW power is to be transmitted over a distance of 30 km, the desirable transmission voltage will be.  (A) 11 kV (B) 33 kV (C) 66 kV (D) 132 kV

Last Answer : By

Description : A transmission line has 1 P.0 impedance on a base of 11 KV, 100 MVA. On a base of 55 KV. it will have a P.0 impedance of

Last Answer : A transmission line has 1 P.0 impedance on a base of 11 KV, 100 MVA. On a base of 55 KV. it will have a P.0 impedance of 0.02 P.U

Description : How many insulator disc used for 33 kV transmission voltage line?

Last Answer : 5,As 33kv is Vrms

Description : DC shunt motor

Last Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Description : If field current is decreased in shunt dc motor, the speed of the motor (a) remains same. (b) increases. (c) decreases. (d) none of the above.

Last Answer : increases

Description : State any four applications of DC shunt motor.

Last Answer : Applications of DC shunt motor: 1) Lathe machines 2) drilling machines 3) milling machines 4) Printing machinery 5) Paper industry 6) centrifugal and reciprocating pumps 7) blowers 8)fans

Description : Why does the speed of a DC shunt motor decrease as the load increases?

Last Answer : Because if the load is increasing then the torque must also be increase. If not then the speed of motor will decrease.

Description : State the use of shunt and series resistance used in extension of meter.

Last Answer : Use of shunt and series resistance: i) Use of shunt: To extend the range of Ammeter. ii) Use of series resistance: To extend the range of Voltmeter.

Description : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be

Last Answer : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be 474 V

Description : Shunt compensation in an EHV line is used to (A) Improve stability. (B) Improve the voltage profile. (C) Reduce the fault level. (D) Substitute for synchronous phase modifier.

Last Answer : Shunt compensation in an EHV line is used to Improve the voltage profile.

Description : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is

Last Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

Description : A shunt fault is characterized by (A) Increase in current, frequency and pf (B) Increase in current, reduction in frequency and pf (C) Increase in current and frequency, reduction in pf (D) Decrease in current and frequency

Last Answer : B

Last Answer : The function of shunt in an ammeter is to by pass the current.

Description : A sinusoidal voltage of 5 Hz is applied to the field of a shunt generator. The armature voltage wave?

Last Answer : A sinusoidal voltage of 5 Hz is applied to the field of a shunt generator. The armature voltage wave will be of 5 Hz.

Last Answer : A cumulatively compounded long shunt generator when operating as a motor would be differentially compounded long shunt.

Description : The e.m.f. induced in the armature of a shunt generator is 600 V. The armature resistance is 0.1 ohm. If the armature current is 200 A, the terminal voltage will be?

Last Answer : The e.m.f. induced in the armature of a shunt generator is 600 V. The armature resistance is 0.1 ohm. If the armature current is 200 A, the terminal voltage will be 580 V.

Description : A shunt generator running at 1000 r.p.m. has generated e.m.f. as 200 V. If the speed increases to 1200 r.p.m., the generated e.m.f. will be nearly?

Last Answer : 200V/E2 = 1000/1200 E2= 240 V

Last Answer : If a D.C. shunt motor is working at full load and if shunt field circuit suddenly opens this will make armature to take heavy current, possibly burning it.

Last Answer : The purpose of retardation test on D.C. shunt machines is to find out stray losses.

Last Answer : In a manual shunt motor starter over load relay is connected in series and no volt relay in parallel with the load.

Last Answer : D.C. shunt motors are used for driving machine tools.

Last Answer : If the speed of a D.C. shunt motor is increased, the back e.m.f. of the motor will increase.

Last Answer : For a D.C. shunt motor if the excitation is changed torque will change but power will remain constant.

Last Answer : The speed of a D.C. shunt motor can be increased by increasing the resistance in field circuit.

Last Answer : The armature torque of the D.C. shunt motor is proportional to armature current.

Last Answer : As the load is increased the speed of D.C. shunt motor will reduce slightly.

Last Answer : The mechanical power developed by a shunt motor will be maximum when the ratio of back e.m.f. to applied voltage is 0.5.

Last Answer : In a D.C. shunt motor, under the conditions of maximum power, the current in the armature will be more than full-load current.

Last Answer : In case of D.C. shunt motors the speed is dependent on back e.m.f. only because flux is practically constant in D:C. shunt motors.

Last Answer : In a D.C. shunt motor, speed is independent of armature current.

Last Answer : The speed of a D.C. shunt motor more than its full-load speed can be obtained by decreasing the field current.

Last Answer : In D.C. shunt motors as load is reduced the speed will remain almost constant.