Zero-sequence current is used for relaying purpose only in the case of  

(a) Phase over current relay (b) Phase impedance relay (c) Ground over current relay (d) Ground impedance relay

1 Answer

Answer :

Zero-sequence current is used for relaying purpose only in the case of Ground impedance relay

Related questions

Last Answer : An efficient and a well designed protective relaying should have good selectivity and reliability, economy and simplicity, high speed and selectivity.

Description : The line trap unit employed in carrier current relaying: (A) offers high impedance to 50 Hz power frequency signal (B) offers high impedance to carrier frequency signal (C) offers low impedance to carrier frequency signal (D) Both (A) & (C)

Last Answer : Ans: B The line trap unit employed in carrier current relaying offers high impedance to carrier frequency signal. Because carrier frequency range is 35 km – 500 kHz XL = 2Π f l Where f increases XL will also increases

Description : The line trap unit employed in carrier current relaying method offers: (A) high impedance to 50 Hz power frequency signal (B) high impedance to carrier frequency signal (C) low impedance to ... signal (D) high impedance to 50 Hz power frequency signal and high impedance to carrier frequency signal

Last Answer : The line trap unit employed in carrier current relaying method offers: high impedance to carrier frequency signal 

Description : An efficient and a well designed protective relaying should have (a) good selectivity and reliability (b) economy and simplicity (c) high speed and selectivity (d) all of the above

Last Answer : (d) all of the above

Description : What is the full form of PQRS used for Track renewal works. a. Plasser quick Relaying system* b. Please quick return services c. Poor Quality renewal system d. None of above

Last Answer : a. Plasser quick Relaying system*

Description : ln HRC fuse the time between cut-off and final current zero is called

Last Answer : ln HRC fuse the time between cut-off and final current zero is called the arcing time

Description : The current zero interruption, in oil and air blast circuit breakers, is achieved by?

Last Answer : The current zero interruption, in oil and air blast circuit breakers, is achieved by lengthening of the gap, cooling and blast effect.

Description : Explain negative phase sequence protection of alternator.

Last Answer : Negative phase sequence protection of alternator: Unbalanced loading on alternator mainly causes the negative sequence currents which generate the negative sequence components of magnetic fields. These fields ... components due to unbalance and operates the relay which further operates CB.

Description : A negative sequence relay is used for protection of  (1) Generator (3) Motor (2) Transformer (4) Long Transmission lines

Last Answer : A negative sequence relay is used for protection of Generator 

Description :  A power system is subjected to a fault which makes the zero sequence component of current equal to zero. The nature of fault current is: A) Double line to ground fault B) Line to line fault C) Line to ground fault D) Three-phase to ground fault

Last Answer :  A power system is subjected to a fault which makes the zero sequence component of current equal to zero. The nature of fault current is: Line to line fault

Description : The zero sequence current of a generator for line to ground fault is j 2.4 p.u. The current through the neutral during the fault is (a) j 0.8 p.u (b) j 2.4 p.u. (c) j 0.24 p.u. (d) j 7.2 p.u. 

Last Answer : j7.2

Description : How can we use CT and PT for protection purpose?

Last Answer : CT and PT for Protection purpose: Current transformer (CT) and Potential transformer (PT) are instrument transformers, which are used in conjunction with protective relays for protection purpose. The CT ... from the healthy part. In this way the CT and PT can be used for protection purpose.

Description : The purpose of the restraining coil in a biased differential relay is  (A) To reduce CT saturation during fault.  (B) To increase the sensitivity of the relay.  (C) To match the transformation ratio.  (D) To limit the spill current through the relay during heavy external fault.

Last Answer : d

Last Answer : The contacts of high voltage switches used in power system are submerged in oil. The main purpose of the oil is to extinguish the arc.

Description : State four abnormalities that taking place in case of motors.

Last Answer : Abnormalities that Taking Place in Case of Motors: A) Electrical / magnetic sections: 1) Electrical supply failure due to single phasing, under voltage, unbalanced voltages and reversal of phases ... , damaged fan. 7) Failure / disturbances of alignment. 8) Foundation arrangement disturbed.

Description : Auto reclosing is used in case of

Last Answer : Auto reclosing is used in case of air blast C.B.

Description : Describe the operation of current differential relay with neat sketch.

Last Answer : Operation of Current Differential Relay: Figure shows an arrangement of an overcurrent relay connected to operate as a differential relay for alternator protection under fault conditon. ... current flows through relay coil, causing relay to operate for protection of alternator winding.

Description : Define the following terms with respect to protective relays i) Relay time ii) Reset current iii) Plug setting multiplier and iv) Time setting multiplier

Last Answer : 1) Relay Time: The time interval between occurrence of fault and closure of relay contacts.  2) Reset Current: The value of current below which the relay resets and comes back to ... The adjustment arrangement provided for setting the operation time of relay is known as Time setting multiplier. 

Description : Define the following terms related to circuit breaker. 1) Breaking Capacity 2) Making Capacity 3) Short time rating and 4) Normal current rating

Last Answer : 1) Breaking Capacity: It is current (r.m.s) that a circuit breaker is capable of breaking at given recovery voltage under specified conditions (e.g. power factor, rate of rise of ... under specified conditions. The only limitation in this case is the temperature rise of current-carrying parts.

Description : Draw a typical time-current characteristic for IDMT relay. 

Last Answer : Time-Current Characteristic for IDMT Relay:

Description : Explain over-current protection of transformer.

Last Answer : Over-Current Protection of Transformer: Simple over-current & earth fault protection of transformer against external shortcircuit and excessive overloads is shown in the above figure. The ... trip command to the circuit breaker and the transformer is disconnected from load or fault.

Description : Describe over current relay with time-current characteristic.

Last Answer : Over current relay with time-current characteristics:- 1. Definite time over current relay: Operating time is constant, the relays operates after a predetermined time when the current exceeds the pickup ... of fault current and definite time characteristics at higher values of fault current.

Description : Explain construction and operation of induction type directional over current relay.

Last Answer : Directional overcurrent relay: Construction: It consists of two units: i) Non-directional Over-current unit ii) Directional power unit The directional unit consists of upper electromagnet ... closes the trip circuit. This operates circuit breaker which isolates the faulty section. 

Description : Explain current limiting reactor.

Last Answer : Current Limiting Reactor: A Reactor is a coil of number of turns designed to have large inductance with negligible ohmic resistance connected in series with equipment to limit the short circuit current. ... reactors 2) Feeder reactors 3) Busbar reactors i) Ring Systems ii) Tie bar system

Description : The burden of protective Current Transformer (CT) is specified in

Last Answer : The burden of protective Current Transformer (CT) is specified in Volt - Ampere

Description : In order to reduce the voltage surges due to current chopping and capacitive current breaking, we connect (A) A resistor across the CB contacts. (B) A capacitor across the CB contacts. (C) An inductor across the CB contacts. (D) A switch across the CB contacts

Last Answer : In order to reduce the voltage surges due to current chopping and capacitive current breaking, we connect A resistor across the CB contacts.

Description : The operating point of a protective current transformer is near the

Last Answer : The operating point of a protective current transformer is near the Ankle point

Description : If the fault current is 6000 A, the relay plug setting is 150% and the CT ratio is 400/5, the plug setting multiplier will be

Last Answer : If the fault current is 6000 A, the relay plug setting is 150% and the CT ratio is 400/5, the plug setting multiplier will be 10

Description : If the % reactance upto the fault point is 20%, then the short circuit current will be

Last Answer : If the % reactance upto the fault point is 20%, then the short circuit current will be 5 times the full load current

Description : The inrush current of a transformer at no load is maximum if the supply voltage is switched on  (1) at peak voltage value (2) at zero voltage value (3) at half voltage value (4) at 0.866 time voltage value

Last Answer : At 0.866 time voltage value

Description : The eddy current loss in a dc generator is 400 W at 40 Hz frequency of reversal and constant flux density. When frequency is increased to 50 Hz., eddy current loss is :  (A) 256 W (B) 320 W (C) 500 W (D) 625 W

Last Answer : The eddy current loss in a dc generator is 400 W at 40 Hz frequency of reversal and constant flux density. When frequency is increased to 50 Hz., eddy current loss is : 625 W

Description : In the induction type directional over current relay, when a short-circuit occurs in the circuit (A) power flows in reverse direction (B) power flows in normal direction (C) directional power element does not operate (D) over current element is not energized

Last Answer : In the induction type directional over current relay, when a short-circuit occurs in the circuit power flows in reverse direction

Last Answer : The inverse definite mean time relays are used for over current and earth fault protection of transformer against internal short-circuits.

Last Answer : In order that current should flow without causing excessive heating or voltage drop, the relay contacts should have low contact resistance, be clean and smooth, be of sufficient size and proper shape.

Last Answer : Thermal overload relays are used to protect the motor against overcurrent due to heavy loads.

Description : In which fault the maximum short circuit current occurs?

Last Answer : In three phase bolted fault the maximum short circuit occurs.

Description : The purpose of a motor undervoltage protection device is to _____________. A. prevent high armature current when power is restored B. start the motor at a very low voltage C. trip the load off the motor in case of fire D. protect personnel from low voltage shocks

Last Answer : Answer: A

Description : Define zero sequence component.

Last Answer : They has 3 vectors having equal magnitudes and displaced from each other by an angle zero degrees.

Description : What is meant by positive, negative and zero sequence reactance.

Last Answer : The reactance diagram of a power system, when formed using positive, negative and zero sequence reactances are called positive, negative and zero sequence reactance diagram resp.

Description : What is meant by positive, negative and zero sequence impedance.

Last Answer : The impedance of the circuit element for positive, negative and zero sequence component currents are called positive, negative and zero sequence impedances resp.

Description : What are zero sequence components?

Last Answer : The zero sequence components of a three phase unbalanced vectors consists of 3 vectors of equal magnitude and with zero phase displacement from each other.

Description : When the Zero sequence reactance arises? 

Last Answer : If a machine is operating with an earthed neutral, a system earth fault will give rise to zero sequence current in the machine. 

Description : What is Zero sequence reactance? 

Last Answer : If a machine is operating with an earthed neutral, a system earth fault will give rise to zero sequence current in the machine. 

Description : What you mean by positive sequence, negative sequence and zero sequence of voltage?

Last Answer : Positive phase sequence A system of vectors is said to have positive sequence if they are all of equal magnitude and are displaced by 120° with same time interval to arrive at fixed axis of reference ... in all the 3- phases. Such phase sequence is zero phase sequence.

Description : Consider the following salient points in a stress-strain curve of a mild steel bar: 1. Yield point 2. Braking point 3. Yield plateau 4 . Proportionality limit 5. Ultimate point The correct sequence in which they occur while testing the mild ... , 5 and 2 (c) 4, 1, 3, 5 and 2 (d) 1, 4, 2, 3 and 5

Last Answer : (c) 4, 1, 3, 5 and 2

Description : Correct hormonal sequence in the case of menstruation is

Last Answer : Correct hormonal sequence in the case of menstruation is A. FSH , progesterone , estrogen B. ... , progesterone D. Esterogen , progesterone , FSH

Description : What type of a structure is this? a) sequence b) case c) repetition d) process

Last Answer : Answer: b Explanation: This is a case structure. Certain cases are given along with a default case in the case structure

Description : What type of structure is this? a) sequence b) case c) repetition d) process

Last Answer : Answer: c Explanation: This is a repetition structure. The action performed by a repetition structure must eventually cause the loop to terminate. Otherwise, an infinite loop is created

Description : The action performed by a ___________ structure must eventually cause the loop to terminate. a) sequence b) case c) repetition d) process

Last Answer : Answer: c Explanation: The action performed by a repetition structure must eventually cause the loop to terminate. Otherwise, an infinite loop is created