If the inertia constant H of a machine of 200 MVA is 2 p.u., its value corresponding to 400 MVA will be 

 (a) 4 p.u. (b) 2 p.u. (c) 1.0 p.u. (d) 0.5 p.u. 

1 Answer

Answer :

If the inertia constant H of a machine of 200 MVA is 2 p.u., its value corresponding to 400 MVA will be 1.0 p.u.

Related questions

Description : The p.u. parameter for a 500 MVA machine on its own base are: inertia, M = 20 p.u. ; reactance, X = 2 p.u. The p.u. values of inertia and reactance on 100 MVA common base, respectively, are (A) 4, 0.4 (B) 100, 10 (C) 4, 10 (D) 100, 0.4

Last Answer : The p.u. parameter for a 500 MVA machine on its own base are: inertia, M = 20 p.u. ; reactance, X = 2 p.u. The p.u. values of inertia and reactance on 100 MVA common base, respectively, are 100, 0.4

Description : A 100 MVA, 11 KV, 3-phase, 50 Hz, 8—pole synchronous generator has an inertia constant H equal to 4 seconds. The stored energy in the rotor of the generator at synchronous speed will be  A) 100 MJ B) 400 MJ C) 800 MJ D) 12.5 MJ

Last Answer : 800

Description : A 50 Hz, 4 pole turboalternator rated at 20 MVA. 13.2 KV has an inertia constant H = 4 KW sec/KVA. The K.E. stored in the rotor at synchronous speed is

Last Answer : A 50 Hz, 4 pole turboalternator rated at 20 MVA. 13.2 KV has an inertia constant H = 4 KW sec/KVA. The K.E. stored in the rotor at synchronous speed is 80 MJ

Description : A 60 Hz, 4 pole turbo generator rated 100 MVA, 13.8 KV has an inertia constant of 10 MJ/MVA. Find the stored energy in the rotor at synchronous speed.  (A) 10 MJ (B) 100 J (C) 1000 J (D) 1000 MJ 

Last Answer : c

Description : The inertia constant of a 100 MVA, 11 kV water wheel generator is 4. The energy stored in the rotor at the synchronous speed is: A) 400 Mega Joule B) 400 Kilo Joule C) 25 Mega Joule D) 25 Kilo Joule

Last Answer : The inertia constant of a 100 MVA, 11 kV water wheel generator is 4. The energy stored in the rotor at the synchronous speed is: 400 Mega Joule

Description : A 500 MVA, 11 KV synchronous generator has 0.2 p.u. synchronous reactance. The p.u. synchronous reactance on the base values of 100 MVA and 22 KV is  A) 0.16 B) 0.01 C) 4.0 D) 0.25

Last Answer : A 500 MVA, 11 KV synchronous generator has 0.2 p.u. synchronous reactance. The p.u. synchronous reactance on the base values of 100 MVA and 22 KV is 0.01

Description : A transmission line has 1 P.0 impedance on a base of 11 KV, 100 MVA. On a base of 55 KV. it will have a P.0 impedance of

Last Answer : A transmission line has 1 P.0 impedance on a base of 11 KV, 100 MVA. On a base of 55 KV. it will have a P.0 impedance of 0.02 P.U

Description : n Widal test the significant titres for H agglutinins is A- 1:50 or more B- 1:100 ormore C- 1:200 or more D- 1:400 or more

Last Answer : 1:200 or more

Description : One 200 KVA transformer has an iron loss of 1 KW and full load Cu loss of 2 KW. Its load KVA corresponding to maximum efficiency is:  (A) 100 KVA (B) 141.4 KVA (C) 50 KVA (D) 200 KVA 

Last Answer : 100

Description : The molar excess Gibbs free energy, gE, for a binary liquid mixture at T and P is given by, (gE/RT) = A . x1. x2, where A is a constant. The corresponding equation for ln y1, where y1is the activity co-efficient of component 1, is (A) A . x22 (B) Ax1 (C) Ax2 (D) Ax12

Last Answer : (A) A . x22

Description : In a D.C. machine the current per brush arm should not be more than (a) 100 A (6) 200 A (e) 300 A (d) 400 A

Last Answer : (d) 400 A

Description : 85. The value of K and H should be determined according to the ARL required for the corresponding cusum chart. a) True b) False

Last Answer : true

Description : A 3-phase circuit breaker is rated at 1250 A, 2000 MVA, 33 kV, 4s. Its making current capacity will be   (a) 35 kA (b) 89 kA (c) 79 kA (d) 69 kA

Last Answer : 89

Description : Commercial available medium size machines have a speed range of ______ . (a) 200 to 400 r.p.m. (b) 600 to 1000 r.p.m. (c) 1000 to 1500 r.p.m. (d) 2000 to 2500 r.p.m.

Last Answer : (d) 2000 to 2500 r.p.m.

Description :  P and Q undertake to do a piece of job for Rs.1200. P alone can do it in 12 days while Q alone can do it in 16 days. With the help of R , they finish it in 6 days. Find the share of P,Q & R. a) 400,600,200 b) 200,400,600 c) 450,400,250 d) 600,450,150

Last Answer : D R;s 1 day work = 1/6 – (1/12 + 1/16) =1/6 – 1/12 – 1/16 = (8-4-3)/48 = 1/48 P:Q:R = ratio of 1 day work = 1/12:1/16 : 1/48 =4:3:1 P’s share = Rs(1200*4/8) =Rs.600 Q’s share = Rs(1200 * 3/8) =Rs.450 R’s share = Rs(1200 * 1/8) =Rs.150

Description : Two taps P and Q can separately fill a tank in 120mins and 150 mins respectively. There is a 3rd tap in the bottom of the tank to empty it. If all of the 3 taps are simultaneously opened, then the tank is full ... . In how much time the 3rd pipe alone can empty the tank? A) 100 B) 200 C) 300 D) 400

Last Answer : B Work done by the 3 tap in 1 min = 1/100 – ( 1/120 + 1/150) = 1/100 – (5+4/600) =1/100 – 9/600 =6-9/600 = - 3/600 = - 1/200(negative signs mean empting) Therefore the 3rd tap alone can empty the tank in 200 mins

Description : The maximum compressive stress at the top of a beam is 1600 kg/cm2 and the corresponding tensile stress at its bottom is 400 kg/cm2 . If the depth of the beam is 10 cm, the neutral axis from the top, is (A) 2 cm (B) 4 cm (C) 6 cm (D) 8 cm

Last Answer : (D) 8 cm

Description : A 3-phase star-connected 75 MVA, 25 kV 3-phase synchronous generator has a synchronous reactance of 1.0 p.u. The per unit value to a 90 MVA base and 30 kV is (A) 2/15 p.u. (B) 5/6 p.u. (C) 1.0 p.u. (D) 1.2 p.u.

Last Answer : A 3-phase star-connected 75 MVA, 25 kV 3-phase synchronous generator has a synchronous reactance of 1.0 p.u. The per unit value to a 90 MVA base and 30 kV is 5/6 p.u.

Description : The per unit impedance of a circuit element is 0.30. If the base kV and base MVA are halved, then the new value of the per unit impedance of the circuit element will be:  (A) 0.3 (B) 0.6 (C) 0.003 (D) 0.006 

Last Answer : 3

Description : square cross section b/h/h'=400/400/40mm with a reinforcement ratio of p=0.015 is loaded for action forces of axial load plus uniaxial bending.the column is to be made of C25/30 concrete & S-460 steel.check whether the column AB is short or long?

Last Answer : 10001/999900

Description : A manufacturer claims to have a heat engine capable of developing 20 h.p. by receiving heat input of 400 kcal/mt and working between the temperature limits of 227° C and 27° C. His claim is  ( ... be possible with lot of sophistications  (d) cost will be very high  (e) theroretically possible.

Last Answer : Answer : b

Description : A centrifugal pump has the following specifications: Power = 4 H.P.; Speed = 800 rpm Head = 8 metres Flow = 1000 litres/minutes. If its speed is halved, the new discharge will be __________ litres/minute. (A) 500 (B) 200 (C) 1000 (D) 750

Last Answer : (A) 500

Description : All MOs including VPMO will be treated a high value MO a) For an amount of Rs 200/- and above b) For an amount of Rs 500/- and above c) For an amount of Rs 1000/- and above d) For an amount of Rs 400/- and above

Last Answer : d) For an amount of Rs 400/- and above

Description : Calorific value of gobar gas (containing CH4 = 60% , H2 = 10% ; CO2 = 30%) may be about __________ Kcal/Nm3 . (A) 1,800 (B) 3,200 (C) 5,400 (D) 10,200

Last Answer : (C) 5,400

Description : A simply supported rolled steel joist 8 m long carries a uniformly distributed load over it span so  that the maximum bending stress is 75 N/mm². If the slope at the ends is 0.005 radian and the  value of E = 0.2 ... joist, is  (A) 200 mm  (B) 250 mm  (C) 300 mm  (D) 400 mm 

Last Answer : (D) 400 mm 

Description : A 400/200 volts transformer has pu impedance of 0.05. The HV side voltage required to circulate full load current during short circuit test is

Last Answer : A 400/200 volts transformer has pu impedance of 0.05. The HV side voltage required to circulate full load current during short circuit test is 20 V

Description : The moment of inertia of a triangular section (height h, base b) about its base, is  (A) bh²/12  (B) b²h/12  (C) bh3 /12  (D) b 3h/12 

Last Answer : (C) bh3 /12 

Description : The depth of centre of pressure (h) for a vertically immersed surface from the liquid surface is given by (where IG = Moment of inertia of the immersed surface about horizontal axis through its centre of gravity, A = Area of immersed surface, ... (IG/ ) - (B) (IG/ ) - (C) ( /IG) + (D) (IG/ ) +

Last Answer : Answer: Option D

Description : The sum of the interior angles of a geometrical figure laid on the surface of the earth differs from that of the corresponding plane figure only to the extent of one second for every (A) 100 sq. km of area (B) 150 sq. km of area (C) 200 sq. km of area (D) None of these

Last Answer : (C) 200 sq. km of area

Description : A stationary hydrogen atom emits a photon corresponding to the first line of the Lyman series. What is the velocity of recoil of the atom? `(m_(H)=1.6

Last Answer : A stationary hydrogen atom emits a photon corresponding to the first line of the Lyman series. What is the velocity ... `(m_(H)=1.672xx10^(-27) kg)`

Description : Pick out the wrong statement. (A) Higher specific gravity of petroleum products means higher C/H ratio (B) Aromatics have lower specific gravity than corresponding paraffins (C) Hydrocarbons of low ... of high specific gravity (e.g., aromatics) possess the maximum thermal energy per unit weight

Last Answer : (B) Aromatics have lower specific gravity than corresponding paraffins

Description : If lines corresponding to given linear equations are coincident, the solutionof the given equations is: e) Unique solution f) Two solutionsg) Infintely many solutions h) No solution

Last Answer : g) Infintely many solutions

Description : A system exhibiting S.H.M. must possess – (1) Elasticity as well as inertia (2) Elasticity, inertia and an external force (3) Elasticity only (4) Inertia only

Last Answer : (1) Elasticity as well as inertia Explanation: Basic conditions to execute simple harmonic motion are: (i) There must be an elastic restoring force acting on the system, (ii) the system ... of the system should be directly proportional to its displacement and is always directed to mean position.

Description : Which of the following relations is used to represent theorem of perpendicular axes? (H = Vertical axis, I = Moment of inertia and K = Radius of gyration) a. IPQ = Ixx + AH2 b. IPQ = Ixx + Ak2 c. Izz = Ixx + Iyy d. Izz + Ixx + Iyy = 0

Last Answer : c. Izz = Ixx + Iyy

Description : A system exhibiting S.H.M. must possess (1) Elasticity as well as inertia (2) Elasticity, inertia and an external force (3) Elasticity only (4) Inertia only

Last Answer : Elasticity as well as inertia

Description : What is the full form of 'MVA' ? -How To ?

Last Answer : The full form of 'MVA' is Motor Vehicles Act

Description : What is the full form of MVA ?

Last Answer : MVA full version Mega Volt Ampere.

Description : How is a 100 MVA transformer cooled?

Last Answer : 100 MVA Transformer is cooled by forced oil forced water cooling method..

Description : If we give 2334 A, 540V on Primary side of 1.125 MVA step up transformer, then what will be the Secondary Current, If Secondary Voltage=11 KV?

Last Answer : A. As we know the Voltage & current relation for transformer-V1/V2 = I2/I1 We Know, VI= 540 V; V2=11KV or 11000 V; I1= 2334 Amps. By putting these value on Relation540/11000= I2/2334 So,I2 = 114.5 Amps

Description : If we give 2334 A, 540V on Primary side of 1.125 MVA step up transformer, then what will be the Secondary Current, If Secondary Voltage=11 KV?

Last Answer :  As we know the Voltage & current relation for transformer-V1/V2 = I2/I1 We Know, VI= 540 V; V2=11KV or 11000 V; I1= 2334 Amps. By putting these value on Relation540/11000= I2/2334 So,I2 = 114.5 Amps

Description : For which of the following ratings of the transformer differential protection is recommended ? (a) above 30 kVA. (b) equal to and above 5 MVA (c) equal to and above 25 MVA (d) none of the above

Last Answer : (b) equal to and above 5 MVA

Description : Which of the following statements is incorrect ? (a) Lightning arrestors are used before the switchgear (b) Shunt reactors are used as compensation reactors (c) The peak short current is (1.8 xV2) ... component (d) The MVA at fault is equal to base MVA divided by per unit equivalent fault reactance

Last Answer : (a) Lightning arrestors are used before the switchgear

Description : The forced oil and air circulation method is usual one for transformers of capacities (a) upto 5 MVA (b) upto 10 MVA (c) upto 20 MVA (d) 30 MVA upwards

Last Answer : (d) 30 MVA upwards

Description : Transformers with a capacity of upto _____ have a cooling radiator system with natural cooling (a) 2 MVA (b) 5 MVA (c) 7.5 MVA (d) 10 MVA

Last Answer : (d) 10 MVA

Description : A 20-MVA, 6.6-kV, 3-phase alternator is connected to a 3-phase transmission line. The per unit positive-sequence, negative-sequence and zero-sequence impedances of the alternator are j0.1, j0.1 and j0.04 respectively. The neutral of ... the fault is  (A) 513.8 V (B) 889.9 V (C) 1112.0 V (D) 642.2 V

Last Answer : A 20-MVA, 6.6-kV, 3-phase alternator is connected to a 3-phase transmission line. The per unit positive-sequence, negative-sequence and zero-sequence impedances of the alternator are j0.1, ... line. The voltage of the alternator neutral with respect to ground during the fault is 642.2 V

Description : A 50 Hz, 4-pole, 500 MVA, 22 kV turbo-generator is delivering rated megavolt amperes at 0.8 power factor. Suddenly a fault occurs reducing in electric power output by 40%. Neglect losses and assume constant power input to the ... the time of fault will be  (A) 1.528 (B) 1.018 (C) 0.848 (D) 0.509

Last Answer : A 50 Hz, 4-pole, 500 MVA, 22 kV turbo-generator is delivering rated megavolt amperes at 0.8 power factor. Suddenly a fault occurs reducing in electric power output by 40%. Neglect losses and assume ... the shaft. The accelerating torque in the generator in MNm at the time of fault will be 1.018 

Description : A generator is connected through a 20 MVA, 13.8/138 kV step down transformer, to a transmission line. At the receiving end of the line a load is supplied through a step down transformer of 10 MVA, 138/69 kV rating. A 0.72 ... load (in per unit) in generator will be (A) 36 (B) 1.44 (C) 0.72 (D) 0.18

Last Answer : A generator is connected through a 20 MVA, 13.8/138 kV step down transformer, to a transmission line. At the receiving end of the line a load is supplied through a step down transformer of 10 MVA, 138/ ... MVA and 69 kV in load circuit, the value of the load (in per unit) in generator will be 36 

Description : A three-phase, 33 kV oil circuit breaker is rated 1200 A, 2000 MVA, 3 s. The symmetrical breaking current is  (A) 1200 A (B) 3600 A (C) 35 kA (D) 104.8 kA

Last Answer : A three-phase, 33 kV oil circuit breaker is rated 1200 A, 2000 MVA, 3 s. The symmetrical breaking current is 35 kA 

Description : The rate constant of a chemical reaction increases by 100 times when the temperature is increased from 400 °K to 500 °K. Assuming transition state theory is valid, the value of ‘E/R’ is (A) 8987°K (B) 9210°K (C) 8764°K (D) 8621°K

Last Answer : (B) 9210°K

Description : The meter constant of a single-phase 230 V induction watt hour meter is 400 revolutions per kWh. The speed of the meter disc for a current of 10 A of 0.9 pf lagging will be

Last Answer : The meter constant of a single-phase 230 V induction watt hour meter is 400 revolutions per kWh. The speed of the meter disc for a current of 10 A of 0.9 pf lagging will be 13.80 rpm