Which of the following factors limit the deflection of the pointer of a PMMC instrument of about 90o

1. Its damping mechanism 

2. Linearity of magnetic field in which the coil moves 

3. Control spring arrangement 

4. Shape of pole shoe for the horse shoe magnet 

 Select the correct answer using the code given below: 

 (a) Only 1 and 3 (b) Only 2 and 4 (c) Only 2 and 3 (d) Only 1 and 4 

1 Answer

Answer :

Which of the following factors limit the deflection of the pointer of a PMMC instrument of about 90o

1. Its damping mechanism 

2. Linearity of magnetic field in which the coil moves 

3. Control spring arrangement 

4. Shape of pole shoe for the horse shoe magnet 

 Select the correct answer using the code given below: 

 (a) Only 1 and 3 (b) Only 2 and 4 (c) Only 2 and 3 (d) Only 1 and 4 

Related questions

Description : Derive the relation for deflection torque in PMMC instrument. 

Last Answer : Ans: The length of coil be l meter and width of coil be d meter. Assume I is the current flowing in the ciol having N turns. Assume B as the flux density in the air gap then F=BIL ... a direct indication of the current in the coil. The pointer deflection can therefore be used to measure current.

Description : Draw the diagram of PMMC instrument and state the deflection torque equation

Last Answer : Equation Ʈ= B*A*I*N Where r= torque Newton. Meter B = flux density in the air gap. Wb/m2 A = effective coil area (m) N= number of turns of wire of the coil

Description :  The main sources of Errors in Permanent Magnet moving Coil (PMMC) are due to : - a) weaking of the permanent magnet due to aging at temperature effects b) weaking of spring due to aging and temperature effects c) change of resistance of the moving coil with temperature d) all the above

Last Answer :  The main sources of Errors in Permanent Magnet moving Coil (PMMC) are due to : - a) weaking of the permanent magnet due to aging at temperature effects b) weaking of spring due to aging and temperature effects c) change of resistance of the moving coil with temperature d) all the above

Description : Basically, a PMMC instrument can be used only in

Last Answer : dc measurements

Description : Another name for PMMC instrument

Last Answer : D'Arsonval

Description : List two advantages of PMMC instrument.

Last Answer : 1. It has uniform scale. 2. Power consumption is low 3. It can be obtained in wide ranges. 4. High sensitivity & accuracy 5. It is unaffected by external magnetic field. 6. Additional damping device not required. 7. Hysteresis problem is not there.

Description : Permanent Magnet Moving Coil (PMMC) Instrument

Last Answer : Permanent Magnet Moving Coil (PMMC) Instrument

Description : State the working principle of PMMC Analog instrument.

Last Answer : Working Principal of PMMC Analog Instrument: When current carrying conductor is placed in a magnetic field, it experiences mechanical force. In PMMC instrument, when current flows through a coil ... coil rotates and pointer attached to the coil shows deflection proportional to the current magnitude.

Description : feature of PMMC instrument. 

Last Answer : Consumes less power Great accuracy. High torque to weight ratio

Description : State the function of former and control spring in PMMC instrument.

Last Answer : Function of Former: To support the coil and provide eddy current damping.  Function of Control Spring: To provide control torque or force and in some instruments springs can be used as current leads.

Description : ‘PMMC instrument is not suitable to measure AC quantity’. State the reason.

Last Answer : The direction of force exerted on moving coil depends on the direction of current flowing through moving coil. If the direction of magnetic field is kept constant, it produces unidirectional torque if the current is ... on the coil in one cycle to zero. Hence the meter cannot read A.C. quantities.

Description : Name the material used for :- (i) Moving coil (ii) Permanent magnet in PMMC instrument.

Last Answer : (i) Material used for Moving coil: Copper, Aluminum( some times)  (ii) Permanent magnets are made of special alloys such as :  Aluminum-Nickel-Cobalt (Alnicos)  Strontium-Iron  Neodymium-Iron-Boron  Samarium-Cobalt.

Description : State working principle of PMMC instrument.

Last Answer : Working Principle of PMMC Instrument: When current carrying conductor is placed in a constant magnetic field, it experiences a force proportional to the current and produces proportional deflection torque. 

Description : Compare PMMC & MI instrument.

Last Answer : MI Instrument  PMMC Instrument  It works on the principles of magnetism.  It works on the principle of DC motor Deflection torque is proportional to square of current  Deflection ... , Voltmeter and Watt meter  Can be used as voltmeter, Ammeter, Galvanometer, ohmmeter  

Description : In a PMMC instrument, the damping provided is :  (A) air damping (C) eddy current damping (B) fluid damping (D) magnetic damping using a magnet

Last Answer : In a PMMC instrument, the damping provided is : eddy current damping 

Description : A PMMC instrument has FSD of 100 μA and a coil resistance of 1 kΩ. To convert the instrument into an ammeter with full scale deflection of 100 mA, the required shunt resistance is (A) 1 Ω (B) 1.001 Ω (C) 0.5 Ω (D) 10 Ω

Last Answer : A PMMC instrument has FSD of 100 μA and a coil resistance of 1 kΩ. To convert the instrument into an ammeter with full scale deflection of 100 mA, the required shunt resistance is 1.001 Ω

Description : PMMC instrument gives uniform scale because:

Last Answer : PMMC instrument gives uniform scale because: It uses spring control and The deflection torque is proportional to the instrument current.

Last Answer : A PMMC instrument can be used as a fluxmeter by: Removing the control spring

Description : If the distance of screen from a CRT to center of deflection plates is 15 cm, the length of deflection plates is 2 cm, the distance between the plates is 1 cm and accelerating voltage is 500 V, deflection sensitivity is   (a) 33.2 V/cm (b) 0.03 cm/V (c) 66.4 V/cm (d) 0.015 cm/V

Last Answer : If the distance of screen from a CRT to center of deflection plates is 15 cm, the length of deflection plates is 2 cm, the distance between the plates is 1 cm and accelerating voltage is 500 V, deflection sensitivity is 0.03 cm/V

Description : An open occurring within the field rheostat of an AC generator can be detected by short circuiting its terminals and observing a ____________. A. negative deflection of the wattmeter pointer B. ... of the wattmeter pointer C. buildup of alternator voltage D. low, but constant alternator voltage

Last Answer : Answer: C

Description : A moving system force in analog instruments which ensures that the deflection of the pointer for a given value of measured quantity always has the same value

Last Answer : controlling force

Description : Torque/weight ratio of an instrument indicates   (a) Selectivity (b) Accuracy (c) Fidelity (d) Sensitivity

Last Answer : Torque/weight ratio of an instrument indicates Sensitivity

Description : A Voltage Controlled Oscillator (VCO) is an instrument : - a) whose frequency is dependent upon the amplitude of input signal b) whose frequency is independent upon the amplitude of input signal c) whose frequency is dependent upon the frequency of input signal d) none of the above

Last Answer : A Voltage Controlled Oscillator (VCO) is an instrument : - whose frequency is dependent upon the amplitude of input signal

Description : When using a multimeter for resistance measurements, it should be calibrated by clipping the loose ends of the leads together and _____________. A. setting the instrument pointer at 'zero' ohms B. ... the plus and minus terminals D. using a special purpose resistance measuring instrument (a bridge)

Last Answer : Answer: A

Description : You are calibrating a multimeter using internal batteries to supply power for resistance measurements. However, you are unable to adjust the pointer to 'zero' using the adjustment knob. Therefore, you should ... change scales to the R X 100 scale and adjust using the 'zero ohms' adjusting knob

Last Answer : Answer: A

Description : When both deflecting and controlling torque act, the pointer of an indicating instrument comes to

Last Answer : rest

Description : If the pointer of an indicating instrument is in motion, then what opposes deflecting torque?

Last Answer : damping and controlling torque

Description : What is the force acting on the pointer of an indicating instrument when it is in motion?

Last Answer : controlling, damping and deflecting torques

Description : An instrument in which the magnitude of the measured quantity is indicated by means of pointer.

Last Answer : analog instrument

Description : The pointer of an indicating instrument is generally made of

Last Answer : aluminum

Last Answer : The pointer of an indicating instrument should be very light.

Description : What Difference between null type and deflection type instrument?

Last Answer : Need answer

Description : Accurate measurement of deflection angles with a transit not properly adjusted may be made by (A) Setting the Vernier A at zero at back station and then plunging the telescope (B) Setting the ... back sights one with the telescope normal and the other with telescope inverted (D) None of these

Last Answer : (C) Taking two back sights one with the telescope normal and the other with telescope inverted

Description : An angle of deflection right, may be directly obtained by setting the instrument to read (A) Zero on back station (B) 180° on back station (C) 90° (D) 270° on back station

Last Answer : (A) Zero on back station

Description : As the deflection of the moving system increases, the controlling torque in an indicating instrument.

Last Answer : increases

Description : What is the typical full-scale deflection current of a moving coil instrument?

Last Answer : 50mA

Description : A permanent magnet moving coil instrument gives full scale deflection of 25mA when a voltage of 75mV is applied across it. Calculate: (i) Resistance of shunt required for full scale deflection of 150 A. (ii) Series resistance for full scale deflection of 500 V.

Last Answer : Answer :

Description : A moving coil instrument has a resistance of 10 W and gives full scale deflection when carrying a current of 50 mA. To measure current upto 100 A, we will have to connect • 10 W resistance in series • 10 W resistance in parallel • 10/1999 W resistance in series • 10/1999 W resistance in parallel

Last Answer : A moving coil instrument has a resistance of 10 W and gives full scale deflection when carrying a current of 50 mA. To measure current upto 100 A, we will have to connect 10/1999 W resistance in parallel

Last Answer :  In a gravity controlled instrument, the deflection angle is proportional to sine inverse of measurand.

Last Answer : The instrument having its deflection depends upon average value is:  Rectifier type

Last Answer : The deflection of hot-wire instrument depends on: RMS value of the alternating current

Description : When paralleling two alternators, the synchronizing lamps remain lit as the synchroscope pointer approaches the 0°. This indicates the _____________. A. incoming alternator is running too fast B. alternator ... apart C. synchroscope is defective or broken D. alternator power factors are in phase

Last Answer : Answer: C

Description : Pick out the wrong statement. (A) The equivalent stiffness of two springs (of equal stiffness 'S') in series is S/2 while in parallel is 2S (B) For a helical spring, deflection is ... is less than the buckling load (D) Modulus of resilience is proportional to (stress at elastic limit)2

Last Answer : (C) Crushing load or columns is less than the buckling load

Description : spring material should have low (A) Elastic limit (B) Deflection value (C) Fatigue resistance (D) None of these

Last Answer : Option D

Description : spring material should have low (A) Elastic limit (B) Deflection value (C) Fatigue resistance (D) None of these

Last Answer : Option D

Description : For a cantilever of effective depth of 0.5 m, the maximum span to satisfy vertical deflection limit is (A) 3.5 m (B) 4 m (C) 4.5 m (D) 5 m

Last Answer : Answer: Option A

Description : In limit state approach, spacing of main reinforcement controls primarily (a) Cracking (b) Deflection (c ) Durability (d) Collapse

Last Answer : (a) Cracking

Description : Limit state of collapse deals with [ A ] strength and stability of the structure [ B ] conditions such as deflection, cracking [ C ] durability [ D ] all the above

Last Answer : [ A ] strength and stability of the structure

Description : Limit state of collapse deals with [ A ] strength and stability of the structure [ B ] conditions such as deflection, cracking [ C ] durability [ D ] all the above

Last Answer : [ A ] strength and stability of the structure

Description : The most important property for the spring material is (a) High elastic limit (b) High deflection value (c) Resistance to fatigue and shock (d) All of these

Last Answer : (d) All of these