Potier reactance of an alternator is almost the same as 

 (a) Field winding reactance (b) Total armature reactance (c) Leakage reactance of field winding (d) Armature leakage reactance

1 Answer

Answer :

Potier reactance of an alternator is almost the same as Armature leakage reactance 

Related questions

Description : Capacitive reactance

Last Answer : Capacitive reactance formula

Description : Parallel Reactance and Resistance Example 1

Last Answer : Parallel Reactance and Resistance Example 1

Last Answer : Circuits with capacitive reactance X C alone. Capacitive reactance X C values in series. There is no resistance or inductive reactance only capacitive reactance is there. Let two capacitive ... horizontal in phasor diagram. The total current I T leads voltage V A by 90 degree.

Description : AC Circuits with Resistance but No Reactance

Last Answer : AC Circuits with Resistance but No Reactance AC Circuits with Resistance but No Reactance Series resistances let two resistances R 1 and R 2 are connected in series as shows in figure and there ... voltage. Voltage V A is common to both the branch hence voltage V A is common reference.

Description : The operating characteristics of a reactance type distance relay (A) a stepped waveform for increasing reactance (B) a straight line for a constant reactance (C) a circle for a constant reactance (D) a set of circles for variable reactances

Last Answer : The operating characteristics of a reactance type distance relay a straight line for a constant reactance

Description : A 3-phase star-connected 75 MVA, 25 kV 3-phase synchronous generator has a synchronous reactance of 1.0 p.u. The per unit value to a 90 MVA base and 30 kV is (A) 2/15 p.u. (B) 5/6 p.u. (C) 1.0 p.u. (D) 1.2 p.u.

Last Answer : A 3-phase star-connected 75 MVA, 25 kV 3-phase synchronous generator has a synchronous reactance of 1.0 p.u. The per unit value to a 90 MVA base and 30 kV is 5/6 p.u.

Description : The maximum possible power of a 3-phase synchronous motor with synchronous reactance 0.8 p.u. connected to a bus-bar of 1.0 p.u. and excitation adjusted to 1.2 p.u. is (A) 0.5 p.u. (B) 0.96 p.u. (C) 1.5 p.u. (D) 1.8 p.u.

Last Answer : The maximum possible power of a 3-phase synchronous motor with synchronous reactance 0.8 p.u. connected to a bus-bar of 1.0 p.u. and excitation adjusted to 1.2 p.u. is 1.5 p.u.

Description : What is the reactance of a 3H inductor when the frequency is 120 Hz? A. 2260 ohm B. 2060 ohm C. 360 ohm D. 0  

Last Answer : 2260 ohm is the reactance of a 3H inductor when the frequency is 120 Hz.

Description : If X is the system reactance and R is its resistance, the power transferred is maximum when (1) X=R (2) X=1.414 R (3) X=1.732 R (4) X=2R 

Last Answer : x = 1.732R

Description : The synchronous reactance of the synchronous machine is the ratio between:  (A) open circuit voltage and short circuit current at Constant field current (B) short circuit Voltage and open ... at different field current (D) short circuit voltage and open circuit current at different field current

Last Answer : The synchronous reactance of the synchronous machine is the ratio between: open circuit voltage and short circuit current at constant field current 

Last Answer : In an induction motor, if the rotor resistance is equal to stand-still reactance then the maximum torque is equal to starting torque.

Description : Capacitive reactance is more when?

Last Answer : Capacitive reactance is more when capacitance is less and frequency of supply is less.

Description : The reactance offered by a capacitor to alternating current of frequency 50 Hz is 20 Q. If frequency is increased to 100 Hz, reactance becomes_____ohms.

Last Answer : The reactance offered by a capacitor to alternating current of frequency 50 Hz is 20 Q. If frequency is increased to 100 Hz, reactance becomes 10 ohms.

Description : What is the unit of reactance?

Last Answer : Unit of reactance is Ohms ( Ω ) .Reactance is denoted by X .

Description : What is the inverse of reactance?

Last Answer : Inverse of reactance is Susceptance .Unit of Susceptance is Siemens.

Description : what is the reciprocal of reactance?

Last Answer : reciprocal of reactance is susceptance.

Description : State any four salient features of turbo- alternator.

Last Answer : Special features of a turbo alternator used in TPS: Special Futures (Highlights): It is 3-phase generator. A separate excitation is given to alternator by DC generator ( ... under voltage protection. Over frequency under frequency protection. Over load protection. Over temperature protection 

Description : In wound rotor alternator, reactive power is maximum at a load angle of 

Last Answer : In wound rotor alternator, reactive power is maximum at a load angle of 0o

Description : In a 3 -phase alternator, if there is only magnetizing armature reaction, the load is :  (A) capacitive (B) inductive (C) resistive (D) inductive and resistive

Last Answer : In a 3 -phase alternator, if there is only magnetizing armature reaction, the load is : capacitive 

Description : What is the frequency of an alternator which has 2 poles and makes 3600 revolutions per minute? A) 3600 HZ B) 60 Hz C) 120 Hz D) None of these

Last Answer : What is the frequency of an alternator which has 2 poles and makes 3600 revolutions per minute? A) 3600 HZ B) 60 Hz C) 120 Hz D) None of these

Description : For a 210 MW, turbo-alternator in a thermal power plant, the possible specifications of rotor diameter, stator core length, and number of poles, respectively, are (A) 4.4 m, 1.2 m, 12 (B) 1.2 m, 4.4 m, 2 (C) 4.4 m, 1.2 m, 24 (D) 1.2 m, 4.4 m, 8

Last Answer : For a 210 MW, turbo-alternator in a thermal power plant, the possible specifications of rotor diameter, stator core length, and number of poles, respectively, are 1.2 m, 4.4 m, 2

Description : A alternator is delivering power to a balanced load at unit power factor. The phase angle between the line voltage and the line current is? (A) 90° (B) 60° (C) 30° (D) 0° 

Last Answer : A alternator is delivering power to a balanced load at unit power factor. The phase angle between the line voltage and the line current is 30°

Description : The current from the stator of an alternator is taken out to the external load circuit through: (A) slip rings (B) commutator segments (C) solid connections (D) carbon brushes

Last Answer : D  is correct

Description : During 3-phase short circuit on a unloaded alternator, the dc component may be zero in (1) One phase only (2) Any two phases (3) All three phases (4) None of the above 

Last Answer : 1

Description : An alternator with frequency f1 is to be synchronized with an infinite bus of frequency f. For proper synchronization (1) f1=f (2) f1<f (3)f1>f (4) either (b) or (c) 

Last Answer : A

Description : An alternator is delivering rated current at rated voltage and 0.8 power-factor lagging. For delivering rated current at rated voltage and 0.8 poWer—factor leading, the required excitation will be:  (A) less  (B) more (C) more or less (D) the same

Last Answer : An alternator is delivering rated current at rated voltage and 0.8 power -factor lagging. For delivering rated current at rated voltage and 0.8 power -factor leading, the required excitation will be: more 

Description : What is the pitch factor of a 4 pole alternator having 36 slots and a coil span of 1 to 8?  (A) 140° (B) 80° (C) 20° (D) 40°

Last Answer : C

Description : Two 550 kVA alternator operate in parallel to supply the following loads I. 250 KW at 0.95 p.f. lagging II. 100 KW at 0.85 p.f. leading One machine is supplying 200 KW at 0.9 p.f. lagging. The p.f. of other machine must be

Last Answer : Two 550 kVA alternator operate in parallel to supply the following loads I. 250 KW at 0.95 p.f. lagging II. 100 KW at 0.85 p.f. leading One machine is supplying 200 KW at 0.9 p.f. lagging. The p.f. of other machine must be 0.89 leading

Description : Which of the following statements is true concerning the operation of two alternators in parallel? A. The cycles per second of each alternator are the same. B. Both alternator governors must be set ... be the same on each alternator. D. The load must always be divided equally between alternators.

Last Answer : Answer: A

Description : If field excitation is suddenly lost to an alternator operating in parallel, that alternator will _____________. A. supply excessive current to the bus B. operate at the same load, but with reduced voltage C. lose its load and tend to overspeed D. become overloaded and slow down

Last Answer : Answer: C

Description : When 220V dc shunt alternator generating the voltage at rated value. If direction of rotation is reversed, then alternator will a) Build up its voltage with same polarity b) Build up its voltage with opposite polarity c) No build up of voltage d) None

Last Answer : Ans: No build up of voltage

Description : An alternator is delivering rated current at rated voltage and 0.8 power-factor lagging case. If it is required to deliver rated current at rated voltage and 0.8 power-factor leading, the required excitation will be (A) less. (B) more. (C) more or less. (D) the same.

Last Answer : Ans: B Over excitation gives leading power factor and under excitation gives lagging p.f .

Description : What is the effect of resistance and reactance on power factor ?

Last Answer : Power factor depends on resistance and reactance. As the resistance of the circuit increases, the phase angle between the current and the voltage decreases, resulting in an increase in the power factor ... current and the voltage increases, resulting in a decrease in the power factor of the circuit.

Description : What is the expression of capacitive reactance ?

Last Answer : Capacitive reactance = XC

Description : In a series `LCR` circuit the frequency of a `10 V`, `AC` voltage soure is adjusted in such a fashion that the reactance of the inductor meausers `15

Last Answer : In a series `LCR` circuit the frequency of a `10 V`, `AC` voltage soure is adjusted in such a ... the series combination of `L` and `C`will be:

Description : Why is there no inductive reactance in DC circuits?

Last Answer : Inductive reactance is a resistance by inductors to the changeof current flow, and is dependent on the frequency at which thecurrent oscillates. DC current flows in only one direction so aninductor's impedance remains the same.

Description : Three factors responsible for the change in voltage as load is applied to an AC generator are: 1) the drop in resistance in the armature circuit, 2) the change in flux, and 3) the ____________. A. armature winding speed B. inductance load drop C. coil pitch factor D. armature reactance voltage drop

Last Answer : Answer: D

Description : An AC circuit has a capacitive reactance of 30 ohms in addition to an inductive reactance of 40 ohms connected in series. What is the reactance of the circuit? A. 8.37 ohms B. 10.00 ohms C. 50.00 ohms D. 70.00 ohms

Last Answer : Answer: B

Description : The torque and current curves for a three-phase induction motor with a cage rotor, are shown in the illustration. Which of the following statements is true concerning the depicted curves? EL-0056 A. As slip ... D. If the motor is loaded to the point where 40% slip has resulted, it will stall.

Last Answer : Answer: D

Description : In the illustrated circuit, one advantage of the capacitor coupling over direct coupling is ____________. EL-0048 A. as the frequency decreased the capacitive reactance (Xc) increases B. the amplifier becomes ... of the signal while it isolates the biasing of each stage. D. good frequency response.

Last Answer : Answer: C

Description : The hook-on AC volt-ammeter consists essentially of a split-core and a rectifiertype instrument connected to the secondary winding of a _____________. A. potential transformer B. control transformer C. current transformer D. reactance transformer

Last Answer : Answer: C

Description : Which of the following statements concerning AC circuits is correct? A. The power factor of a resistive circuit is always zero. B. True power in an inductive circuit always equals apparent power. ... . D. Total opposition to the flow of alternating current depends upon the amount of reactive power.

Last Answer : Answer: C

Description : In an AC circuit, the inductive reactance of a coil varies with the _______________. A. resistance of the circuit B. frequency of the circuit C. voltage of the circuit D. current of the circuit

Last Answer : Answer: B

Description : In a series wound motor, the current passing through the field windings is also passing through the _____________. A. armature B. shunt field C. reactance comparator D. laminations

Last Answer : Answer: A

Description : Decreasing the frequency in a capacitive circuit while maintaining a constant circuit voltage, will result in a/an _____________. A. increase in apparent power B. decrease in circuit current C. decrease in capacitive reactance D. decrease in total impedance

Last Answer : Answer: B

Description : An AC circuit has capacitance arranged in series. If the line voltage remains constant, the capacitive reactance value can be varied by changing the _____________. A. line frequency B. resistance C. number of commutating poles D. number of interpoles

Last Answer : Answer: A

Description : The component labeled 'CR1' in the circuit shown in the illustration __________________. EL-0085 A. varies its anode/cathode polarity depending on 'RL' current B. rectifies the varying voltage from the ... reactance to smooth ripple D. establishes a constant reference voltage for the base of 'Q1'

Last Answer : Answer: D

Description : Although saturable reactors are extremely useful in some applications, their gain is low because of ____________. A. core hysteresis losses B. inductive reactance in the control winding C. IR drop throughout the load winding D. all of the above

Last Answer : Answer: A

Description : A saturable-core reactor operates on the principle of controlling a load winding's inductance by varying the core's _____________. A. dielectric B. permeability C. reactance D. inductance

Last Answer : Answer: B

Description : When a megohmmeter is used to test insulation, the gradual rise of the pointer reading as a result of continued cranking, is caused by _____________. A. good conductor resistance B. the ... insulation C. the inductive reactance of the windings D. the dielectric-absorption effect of the insulation

Last Answer : Answer: D