What structurally large, low-resistance conductor is  connected in parallel with the meter movement to prevent  damage?

1 Answer

Answer :

Shunt.

Related questions

Description : When a resistor is used as a shunt and is connected in parallel with a meter movement coil, it will provide _____________. A. a measurement of circuit resistance B. an increased accuracy of approximately 1.5 percent C. an extended meter range D. none of the above

Last Answer : Answer: C

Description : When troubleshooting electronic equipment, you should use a high impedance multimeter ________________. A. to prevent excess current flow through the meter that would damage it B. for AC measurements only ... being tested D. so as not to load down the circuit and obtain erroneous voltage readings

Last Answer : Answer: D

Description : When measuring AC current flow, you must always connect the meter _____________. A. in series with the power source and load B. in parallel with the power source and load C. insuring correct polarity D. using the lowest range possible to prevent instrument damage

Last Answer : Answer: A

Description : The basic meter movement responds to the flow of current through its coil. Therefore, this meter movement may be used as a/an _____________. A. voltmeter by placing a resistance in parallel with the ... in parallel with the coil D. ammeter by placing a low resistance in parallel with the coil

Last Answer : Answer: D

Description : External shunts are sometimes used with ammeters to _______. A. increase meter sensitivity B. permit shunts with larger resistances to be utilized C. prevent damage to the meter movement from heat generated by the shunt D. enable the construction of a compact meter with a virtually unlimited range

Last Answer : Answer: C

Description : Which of the following meters uses a shunt connected in series with the load, but parallel with the meter movement? A. voltmeter B. power factor meter C. wattmeter D. ammeter

Last Answer : Answer: D

Description : The shunt of a DC ammeter should be connected in __________. A. series with the load and in parallel with the meter movement B. parallel with the load and in series with the meter movement C. ... and in parallel with the meter movement D. series with the load and in series with the meter movement

Last Answer : Answer: A

Description : Which of the listed meters uses a shunt connected in series with the load, but parallel with the meter movement? A. Voltmeter B. Power factor meter C. Ammeter D. Wattmeter

Last Answer : Answer: C

Description : The shunt used in an ammeter should be connected in ____________. A. series with the load and in parallel with the meter movement B. parallel with the load and in series with the meter movement C. ... in parallel with the meter movement D. series with the load and in series with the meter movement

Last Answer : Answer: A

Description : A shunt-type voltage regulator is connected in serial/parallel (which one) with the load resistance.

Last Answer : In parallel.

Description : A shunt type voltage regulator is connected in series/parallel with the load resistance.

Last Answer : Parallel

Description : Three resistors connected in parallel have values of 12 kΩ, 20kΩ, and 30kΩ. What is the equivalent resistance? A37. 6kΩ Q38. Two resistors connected in parallel have values of 10 kΩ and 30kΩ. What is eht equivalent resistance?

Last Answer : 7.5kΩ

Description : Four equal resistors are connected in parallel, each resistor has an ohmic value of 100 ohms, what is the equivalent resistance?

Last Answer : 25 ohms

Description : To prevent damage from lightning, lightning conductors are used on tall structures. The lightning conductor - (1) should be made of a good conductor but can be of any shape (2) should be in the form ... can be of any shape (4) should be made of a good conductor like copper with sharp-pointed edges

Last Answer : (4) should be made of a good conductor like copper with sharppointed edges Explanation: A lightning conductor is made up of a sharp pointed metal (usually copper metal, as it is a very good ... cloud, it will first strike the pointed tip of the lightning conductor and quickly travel to the earth.

Description : To prevent damage from lightning, lightning conductors are used on tall structures. The lightning conductor (1) should be made of a good conductor but can be of any shape (2) should be in the form of ... can be of any shape (4) should be made of a good conductor like copper with sharp-pointed edges

Last Answer : should be made of a good conductor like copper with sharp-pointed edges

Description : What material is applied to electronic assemblies to prevent damage from corrosion, moisture, and stress?

Last Answer : Conformal coating

Description : The asbestos cement sewers are A. Light in weight B. Not structurally strong to bear large compressive stress C. Susceptible to corrosion by sulphuric acid D. All the above

Last Answer : ANS: D

Description : Why in an ammeter low resistance is connected in parallel with the coil?

Last Answer : Feel Free to Answer

Description : Before servicing the device indicated as 'A' in panels #1 and #3 of the illustration, the device labeled 'CT' must __________. EL-0003 A. have the disconnected leads taped to prevent ... D. have one lead grounded to discharge static electricity for the prevention of damage to electronic components

Last Answer : Answer: C

Description : What is the only use for the voltage sensitive meter movement?

Last Answer : High-voltage measurement.

Description : What type of meter movement reacts to voltage rather than current?

Last Answer : Electrostatic.

Description : How is it possible to use a current sensitive meter movement to measure voltage?

Last Answer : Since the resistance of a meter movement remains the same as the pointer is deflected, the amount of current through the movement is proportional to the voltage applied. Therefore, only the scale of the movement must be changed.

Description : What value does a meter movement react to (actually measure) when measuring ac?

Last Answer : Average value.

Description : What are two methods used to damp a meter movement?

Last Answer : As the coil moves through the field of the permanent magnet, a current is induced in the coil opposing the movement of the coil; and a vane can be attached to the coil and placed in the airtight chamber so that the movement of the vane opposes the movement of the coil.

Description : How can a d’Arsonval meter movement be adapted for use as an ac meter?

Last Answer : By the use of a rectifier

Description : What are three functions of the hairsprings in a d’Arsonval meter movement?

Last Answer : To return the pointer to its rest position when there is no current flow; to oppose the coil movement when there is current flow; to provide electrical connections for the coil.

Description : What is the effect of current flow through the coil in a d’Arsonval meter movement?

Last Answer : A magnetic field is generated around the coil and the attraction of this field with the permanent magnet causes the coil to move

Description : What type of meter movement is the d’Arsonval meter movement?

Last Answer : A permanent-magnet moving-coil meter movement used in most electrical and electronic meters.

Description : What is the limiting factor as to the amount of current an electrodynamometer meter movement can handle?

Last Answer : Size of spiral conducting.

Description : What components in an electrodynamometer-type meter movement produce the magnetic field?

Last Answer : Fixed coils.

Description : What is the limiting factor as to the amount of current an electrodynamometer meter movement can handle?

Last Answer : Size of spiral conducting.

Description : What components in an electrodynamometer-type meter movement produce the magnetic field?

Last Answer : Fixed coils.

Description : What modification is made to the D’Arsonval meter movement to enable the meter to measure voltage?

Last Answer : A multimeter (high resistance) is placed in series with the coil of the meter.

Description : What advantage is gained by using pole pieces with curved faces in the D’Arsonval meter movement?

Last Answer : Two-position and three-position.

Description : What component supplies restoring force to the coil of the D’Arsonval meter movement?

Last Answer : Hairspring.

Description : What component of the D’Arsonval meter movement completes the circuit for current flow to the coil?

Last Answer : Hairspring.

Description : At what point on a meter movement are the most accurate readings taken?

Last Answer : Midscale.

Description : Which of the listed statements is correct when using an analog multimeter as an ohmmeter? A. The pointer should be adjusted to zero each time a new resistance range is selected. B. The ... C. Ohmmeters are not sufficiently sized to measure conductor insulation resistance. D. All of the above.

Last Answer : Answer: D

Description : Compare the resistance of a conductor to that of an insulator.

Last Answer : Conductors have a very low resistance and insulators have a resistance that is so great that, for all practical purposes, they are nonconductors.

Description : List the three factors used to calculate resistance of a particular conductor in ohms.

Last Answer : Length, cross-sectional area, and specific resistance of a unit volume of the substance from which the conductor is made

Description : A good choice of shunt resistance will place the indicating pointer near what part of the meter scale with a normal load?

Last Answer : Midscale.

Description : How do you compensate for the resistance of the test leads of a meter?

Last Answer : . By zeroing the meter with the test leads shorted.

Description : Is an ammeter connected in series or in parallel with the circuit under test?

Last Answer : . In series.

Description : In a full-wave voltage doubler, are the capacitors connected in series or in parallel with the output load?

Last Answer : In parallel.

Description : For a diode to act as a rectifier, should it be connected in series or parallel with the load?

Last Answer : Series.

Description : When the axes of two connected fibers are no longer in parallel, the two connected fibers are in what kind of misalignment?

Last Answer : Angular misalignment.

Description : Why will an ammeter be damaged if connected in parallel with the circuit to be measured?

Last Answer : Since the ammeter has a small resistance compared to the load, it will have very high current if it is connected in parallel. This high current will damage the meter.

Description : In meter movement, how do oyu prevent the meter from oscillating and overswing?

Last Answer : by damping

Description : Which of the following statements represents the correct method of connecting the shunt of an ammeter prior to taking a reading? A. In series with the load and in series with the meter movement. B. In ... with the meter movement. D. In parallel with the load and in parallel with the meter movement.

Last Answer : Answer: B