A 60 Hz, 2 pole alternator should run at

• a. 3000 r.p.m. c. 1500 r.p.m.

• b. 3600 r.p.m. d. 1800 r.p.m.

1 Answer

Answer :

A 60 Hz, 2 pole alternator should run at 3600 r.p.m.

Related questions

Description :  An 8-pole alternator runs at 750 rpm and supplies power to a 6-pole induction motor which has a full load slip of 3 percent. The full load speed of the induction motor will be: A) 1000 rpm B) 920 rpm C) 950 rpm D) 970 rpm

Last Answer : An 8-pole alternator runs at 750 rpm and supplies power to a 6-pole induction motor which has a full load slip of 3 percent. The full load speed of the induction motor will be: 970 rpm

Description : A 8 pole alternator rotates at 750 r.p.m. Its frequency is

Last Answer : A 8 pole alternator rotates at 750 r.p.m. Its frequency is 50 Hz

Description :  In an alternator if the winding is short pitched by 60 electrical degrees, its pitch factor will be: A) 1.0 B) 0.866 C) 0.75 D) 0.50

Last Answer :  In an alternator if the winding is short pitched by 60 electrical degrees, its pitch factor will be: A) 1.0 B) 0.866 C) 0.75 D) 0.50

Description : State working principle of alternator. State the meaning self and separate excitation. 

Last Answer : Working principle of alternator: When a conductor is moved in magnetic field or a magnetic field moved with respect to conductor, according to Faraday's law of electromagnetic induction, the conductor ... like battery or shaft-mounted exciter, then the excitation is said to be separate excitation.

Description : Explain the construction of alternator with neat diagram.

Last Answer : Diagram: Construction of three phase alternator: Construction wise, an alternator generally consists of field poles placed on the rotating fixture of the machine i.e. rotor as shown in the ... of rotor used in construction of alternator, 1. Salient pole type. 2. Cylindrical rotor type. 

Description :  The driving power from the prime-mover driving the alternator is lost but the alternator remains connected to the supply network; the field supply also remains on. The alternator will: A) ... as a synchronous motor but will rotate in a reverse direction to that corresponding to generator action 

Last Answer : The driving power from the prime-mover driving the alternator is lost but the alternator remains connected to the supply network; the field supply also remains on. The alternator will: behave as a synchronous motor and will rotate in the same direction

Description : Which alternator will have more number of poles ? (a) coupled to steam turbine (b) coupled to gas turbine (c) coupled to hydraulic turbine (d) None of the above 

Last Answer : b

Description : If the excitation of an alternator operating in parallel with other alternators decreased, its: (1) Power factor becomes more leading (2) Output Kw will change (3) Power factor becomes more lagging (4) Power factor becomes unity

Last Answer : If the excitation of an alternator operating in parallel with other alternators decreased, its: Power factor becomes more leading

Description : Drop in alternator frequency is corrected by: (1) Damper winding (2) Increased prime mover output (3) Automatic voltage regulator (4) None of these

Last Answer : Drop in alternator frequency is corrected by: Increased prime mover output

Description : A field excitation of 20 A in a certain alternator results in an armature current of 400 A in short circuit and a terminal voltage of 2000 V on open circuit. The magnitude of the internal voltage drop within the machine at a load current of 200 A is  (A) 1 V (B) 10 V (C) 100 V (D) 1000 V

Last Answer : 800

Description : Is the speed of alternator is directly proportional to frequency?

Last Answer : Yes, speed of alternator is directly proportional to frequency.

Description : At which power factor alternator is said to be overexcited?

Last Answer : At leading power factor alternator is said to be overexcited.

Description : The power factor of an alternator depends on?

Last Answer : The power factor of an alternator depends on load.

Description : In an alternator at lagging power factor the generated voltage per phase as compared to that at unity power factor?

Last Answer : In an alternator, at lagging power factor the generated voltage per phase as compared to that at unity power factor must be more than terminal voltage.

Description : The magnitude of various voltage drops that occur in an alternator depends on?

Last Answer : The magnitude of various voltage drops that occur in an alternator depends on load current.

Description : In alternator where the voltage drop occurs?

Last Answer : In alternator voltage drop occurs in armature resistance, leakage reactance, and armature reactance.

Description : The standard method of controlling the output voltage of a 440 volt, 60 Hz, AC generator is accomplished by adjusting the ____________. A. prime mover speed droop B. number of poles C. alternator field excitation D. load on the alternator

Last Answer : Answer: C

Description : The output voltage of a 440 volt, 60 Hz AC generator is controlled by the ______________. A. load on the alternator B. load on the prime mover C. speed of the prime mover D. exciter output voltage

Last Answer : Answer: D

Description : Salient pole rotor is use for which speed?

Last Answer : Salient pole rotor is use for low and medium speed prime movers.

Description : A four pole, 60 Hz, three-phase synchronous motor comes up to 1760 RPM when started as an induction motor. What is the percent slip after the rotor field is energized? A. 0 B. 1.1 C. 2.2 D. 3.3

Last Answer : Answer: A

Description : If the synchronous speed of a 12 pole, polyphase, induction motor operating at 60 Hz were 600 RPM, how many poles will be required in a similar motor operating at the same frequency but having a synchronous speed of 900 RPM? A. 4 B. 6 C. 8 D. 18

Last Answer : Answer: C

Description : An 8 pole wound rotor induction motor operating on 60 Hz supply is driven at 1800 r.p.m. by a prime mover in the opposite direction of revolving magnetic field. The frequency of the rotor current is (a) 30 Hz (b) 60 Hz (c) 120 Hz (d) 180 Hz 

Last Answer : 30 Hz As the frequency of the rotor is given by  F= N*P/120 so from the above equation the frequency of the rotor current can be easily calculated  i.e. 1800×8/120=30 Hence the required value of rotor frequency is 30 Hz

Description : What is the slip (as a percentage) when a 6 pole single phase induction motor operating on 220 V and 60 Hz is rotating at speed of 1140 rpm? A) 60% B) 5% C) 10% D) None of these

Last Answer : What is the slip (as a percentage) when a 6 pole single phase induction motor operating on 220 V and 60 Hz is rotating at speed of 1140 rpm? A) 60% B) 5% C) 10% D) None of these

Description : A 60 Hz, 4 pole turbo generator rated 100 MVA, 13.8 KV has an inertia constant of 10 MJ/MVA. Find the stored energy in the rotor at synchronous speed.  (A) 10 MJ (B) 100 J (C) 1000 J (D) 1000 MJ 

Last Answer : c

Description : What are the prime movers used for a) Salient pole alternator, b) Non- salient pole alternator.

Last Answer : The prime movers used for salient pole alternators are water wheels likeKaplan turbine, Francis turbine, Pelton wheel etc., and diesel or petrol engines. The prime movers used for non-salient pole alternators are steam turbines and gas turbines.

Description : The number of electrical degrees ‘passed through’ in one revolution of a 6-pole synchronous alternator is: A) 360 degree B) 720 degree C) 1080 degree D) 2160 degree

Last Answer : 1080

Description : Slip test is performed to determine :  (A) Slip in an induction motor  (B) Xd and Xq in a salient pole alternator  (C) Synchronous impedance in an alternator  (D) Positive and negative sequence impedances of an alternator

Last Answer : Slip test is performed to determine :  Xd and Xq in a salient pole alternator 

Description : What is the pitch factor of a 4 pole alternator having 36 slots and a coil span of 1 to 8?  (A) 140° (B) 80° (C) 20° (D) 40°

Last Answer : C

Description : A 3-phase, 400 votts, 50 Hz, 100 KW, 4 pole squirrel cage induction motor with a rated slip of 2% will have a rotor speed of (A) 1500 rpm (B) 1470 rpm (C) 1530 rpm (D) 1570 rpm

Last Answer : Ans: B N = NS (1-S) and NS =120 f / p =120 x 50 /4 = 1500 rpm ∴N= 1500 (1-0.02) =1470 rpm

Description : A balanced three-phase, 50 Hz voltage is applied to a 3 phase, 4 pole, induction motor. When the motor is delivering rated output, the slip is found to be 0.05. The speed of the rotor m.m.f. relative to the rotor structure is (A) 1500 r.p.m. (B) 1425 r.p.m. (C) 25 r.p.m. (D) 75 r.p.m.

Last Answer : (D) 75 r.p.m.

Description : The frequency of the rotor current in a 3 phase 50 Hz, 4 pole induction motor at full load speed is about (A) 50 Hz. (B) 20 Hz. (C) 2 Hz. (D) Zero.

Last Answer : (C) 2 Hz.

Description : The stator of a 415V, 50 Hz, 4-pole slip ring Induction Motor is excited by rated frequency with slip rings open circuited. The rotor is made to rotate at a speed of 600 rpm in the opposite direction to the ... frequency of induced voltage across slip ring is A) 30 Hz B) 70 Hz C) 20 Hz D) 35 Hz

Last Answer : The stator of a 415V, 50 Hz, 4-pole slip ring Induction Motor is excited by rated frequency with slip rings open circuited. The rotor is made to rotate at a speed of 600 rpm in the opposite direction to the normal direction, The frequency of induced voltage across slip ring is 70 Hz

Description : A 50 Hz, 4-pole, 500 MVA, 22 kV turbo-generator is delivering rated megavolt amperes at 0.8 power factor. Suddenly a fault occurs reducing in electric power output by 40%. Neglect losses and assume constant power input to the ... the time of fault will be  (A) 1.528 (B) 1.018 (C) 0.848 (D) 0.509

Last Answer : A 50 Hz, 4-pole, 500 MVA, 22 kV turbo-generator is delivering rated megavolt amperes at 0.8 power factor. Suddenly a fault occurs reducing in electric power output by 40%. Neglect losses and assume ... the shaft. The accelerating torque in the generator in MNm at the time of fault will be 1.018 

Description : A 100 MVA, 11 KV, 3-phase, 50 Hz, 8—pole synchronous generator has an inertia constant H equal to 4 seconds. The stored energy in the rotor of the generator at synchronous speed will be  A) 100 MJ B) 400 MJ C) 800 MJ D) 12.5 MJ

Last Answer : 800

Description : A separately excited d.c. machine is coupled to a 50 Hz, three-phase, 4-pole induction machine as shown in the figure. The Dc machine is energized first and the machines rotate at 1 600 ... three phase source, the phase sequence being consistent with the direction of rotation. In steady state

Last Answer : A separately excited d.c. machine is coupled to a 50 Hz, three-phase, 4-pole induction machine as shown in the figure. The Dc machine is energized first and the machines rotate at 1 600 1pm. ... rotation. In steady state DC machine acts as a motor and the induction machine acts as a generator  

Description : A 400 V, 15 kW, 4-pole, 50 Hz, Y-connected induction motor has full load slip of 4%. The output torque of the machine at full load is  (A) 1.66 Nm (B) 95.50 Nm (C) 99.47 Nm (D) 624.73 Nm

Last Answer : A 400 V, 15 kW, 4-pole, 50 Hz, Y-connected induction motor has full load slip of 4%. The output torque of the machine at full load is 99.47 Nm

Description : The synchronous speed for the seventh space harmonic mmf wave of a 3-phase, 8-pole, 50 Hz induction machine is  (A) 107.14 rpm in forward direction (B) 107.14 rpm in reverse direction (C) 5250 rpm in forward direction (D) 5250 rpm in reverse direction

Last Answer : The synchronous speed for the seventh space harmonic mmf wave of a 3-phase, 8-pole, 50 Hz induction machine is 107.14 rpm in forward direction 

Description : The locked rotor current in a 3-phase, star connected 15 , kW 4 , pole 230 V , 50 Hz induction motor at rated conditions is 50 A. Neglecting losses and magnetizing current, the approximate locked rotor line current drawn when the motor ... Hz supply is  (A) 58.5 A (B) 45.0 A (C) 42.7 A (D) 55.6 A

Last Answer : The locked rotor current in a 3-phase, star connected 15 , kW 4 , pole 230 V , 50 Hz induction motor at rated conditions is 50 A. Neglecting losses and magnetizing current, the approximate locked rotor line current drawn when the motor is connected to a 236 , V 57 Hz supply is 45.0 A 

Description : A 4-pole induction motor, supplied by a slightly unbalanced three-phase 50 Hz source, is rotating at 1440 rpm. The electrical frequency in Hz of the induced negative sequence current in the rotor is  (A) 100 (B) 98 (C) 52 (D) 48

Last Answer : A 4-pole induction motor, supplied by a slightly unbalanced three-phase 50 Hz source, is rotating at 1440 rpm. The electrical frequency in Hz of the induced negative sequence current in the rotor is 98 

Description : A 50 Hz, 4 pole turboalternator rated at 20 MVA. 13.2 KV has an inertia constant H = 4 KW sec/KVA. The K.E. stored in the rotor at synchronous speed is

Last Answer : A 50 Hz, 4 pole turboalternator rated at 20 MVA. 13.2 KV has an inertia constant H = 4 KW sec/KVA. The K.E. stored in the rotor at synchronous speed is 80 MJ

Description : A 12 -pole, 440 V, 50 Hz, 3 -phase synchronous motor takes a line current of 100 A at 0.8 pf leading. Neglecting losses, the torque developed will be

Last Answer : A 12 -pole, 440 V, 50 Hz, 3 -phase synchronous motor takes a line current of 100 A at 0.8 pf leading. Neglecting losses, the torque developed will be 1165 Nm

Description : The power input to the rotor of a 400V, 50 Hz 6 pole three phase induction motor is 20kW. The slip is 3%. The frequency of rotor currents is: (A) 1 Hz (B) 1.5 Hz (C) 2 Hz (D) 1 2 Hz

Last Answer : C

Description : A balanced three-phase, 50 Hz voltage is applied to a 3 phase, 4 pole, induction motor. When the motor is delivering rated output, the slip is found to be 0.05. The speed of the rotor m.m.f. relative to the rotor structure is: (A) 1500 r.p.m. (B) 1425 r.p.m. (C) 25 r.p.m. (D) 75 r.p.m

Last Answer : A balanced three-phase, 50 Hz voltage is applied to a 3 phase, 4 pole, induction motor. When the motor is delivering rated output, the slip is found to be 0.05. The speed of the rotor m.m.f. relative to the rotor structure is: 75 r.p.m

Description : A 3 phase, 400 volts, 50 Hz, 100 kW, 4 pole squirrel cage induction motor with a rated slip of 2% will have a rotor speed of: (A) 1500 rpm (B) 1470 rpm (C) 1530 rpm (D) 1570 rpm

Last Answer : 1470rpm

Description : A centre zero ammeters connected in the rotor circuit of a 6-pole 50 Hz induction motor makes 30 oscillations in one minute. The rotor speed is

Last Answer : A centre zero ammeters connected in the rotor circuit of a 6-pole 50 Hz induction motor makes 30 oscillations in one minute. The rotor speed is 990.

Description : The synchronous speed of an 8 pole induction motor supplied power from a 50 Hz source will be ?

Last Answer : Ns         equals        f/pair pole 50/4      - 12.5

Description : Two 3-phase, Y-connected alternators are to be paralleled to a set of common busbars. The armature has a per phase synchronous reactance of 1.7 Ohm and negligible armature resistance. The line voltage of the first machine is adjusted to ... will be  (A) 16.98 A (B) 29.41 A (C) 33.96 A (D) 58.82 A

Last Answer : Two 3-phase, Y-connected alternators are to be paralleled to a set of common busbars. The armature has a per phase synchronous reactance of 1.7 Ohm and negligible armature resistance. The ... instant they are paralleled. Under this condition, the synchronizing current per phase will be 16.98 A

Description : Which rotor is use for high speed in turbo alternators?

Last Answer : Non-salient pole rotor is used for high speed in turbo alternators.

Description : An alternator is being paralleled with one on the line. At the INSTANT the circuit breaker is closed, the frequency of the incoming alternator will normally _____________. A. increase B. not change C. decrease D. be exactly 60 hertz

Last Answer : Answer: C

Description : The output voltage of a 440 volt, 60 hertz, AC generator is controlled by the _____________. A. prime mover speed B. exciter output voltage C. load on the alternator D. number of poles

Last Answer : Answer: B