Which type of generator gives a constant voltage output at all loads?

1 Answer

Answer :

Level compound generator type of generator gives a constant voltage output at all loads.

Related questions

Description : In the illustration, the component labeled 'EXC' is _______. EL-0003 A. a separate class II regulated DC generator for critical direct current loads B. a generator feeding the FLD ... to drive the governor for turbogenerator speed. D. the electronic driver for the switchboard metering circuits

Last Answer : Answer: B

Description : In the illustration, the contacts between terminals 26 and 27 should be closed when _________. EL-0046 A. using one generator in isochronous mode only B. using two or more generators in ... through varying loads in parallel or single operation D. the circuit breaker is closed for that generator

Last Answer : Answer: C

Description : A constant output voltage from an AC generator is maintained by the _____________. A. prime mover governor B. exciter generator C. voltage regulator D. reverse power relay

Last Answer : Answer: C

Description : Which section of the circuit is responsible for maintaining a nearly constant voltage for all loads within its operating range? EL-0085 A. I B. II C. III D. IV

Last Answer : Answer: D

Description : Which of the following is the demerit of a 'constant voltage transmission system' ? (a) Increase of short-circuit current of the system (b) Availability of steady voltage at all loads at ... of carrying increased power for a given conductor size in case of long-distance heavy power transmission

Last Answer : (a) Increase of short-circuit current of the system

Description : Which of the following is the demerit of a 'constant voltage transmission system' ? (a) Increase of short-circuit current of the system (b) Availability of steady voltage at all loads at ... of carrying increased power for a given conductor size in case of long-distance heavy power transmission

Last Answer : (a) Increase of short-circuit current of the system

Last Answer : Cumulatively compounded D.C. motor will be suitable along with flywheel for intermittent light and heavy loads.

Description : Shunt generator gives full voltage on load and the voltage drop as the load on the generator a. Decreases b. Increases c. Remains the same d. None of above 

Last Answer : Shunt generator gives full voltage on load and the voltage drop as the load on the generator a. Decreases b. Increases c. Remains the same d. None of above 

Description : Two paralleled alternators are operating near rated load. If one trips out mechanically, which of the listed actions should be taken FIRST? A. Restart the tripped machine immediately. B. Strip the board ... circuits. C. Start the emergency generator. D. Transfer all vital loads to the emergency bus.

Last Answer : Answer: B

Description : Capacitors can be used in electric distribution systems to improve power factor. This is accomplished by seesawing energy between the capacitor and the _____________. A. generator B. inductive loads C. resistive loads D. all of the above

Last Answer : Answer: B

Description : If the AVR, is defective, when additional loads come on will the generator be able to take it?

Last Answer : No. Ask E/O and refer to Dennis T Hall.

Description : The most practical way to control the voltage output of an AC generator is to vary the _____________. A. number of windings B. speed of the rotating field C. strength of the rotating magnetic field D. power factor of the load

Last Answer : Answer: C

Description : The standard method of controlling the output voltage of a 440 volt, 60 Hz, AC generator is accomplished by adjusting the ____________. A. prime mover speed droop B. number of poles C. alternator field excitation D. load on the alternator

Last Answer : Answer: C

Description : The voltage output of an AC generator is accurately controlled by _____________. A. changing the sensitivity of the prime mover to large changes in voltage B. varying the reluctance of the air gap C. varying the DC exciter voltage D. shorting out part of the armature windings

Last Answer : Answer: C

Description : The output voltage of a 440 volt, 60 Hz AC generator is controlled by the ______________. A. load on the alternator B. load on the prime mover C. speed of the prime mover D. exciter output voltage

Last Answer : Answer: D

Description : The output voltage of a 440 volt, 60 hertz, AC generator is controlled by the _____________. A. prime mover speed B. exciter output voltage C. load on the alternator D. number of poles

Last Answer : Answer: B

Description : One of the FM signal generator control which varies the phase of the modulating voltage applied to the oscillator of the sweep generator A. Band control B. Phase control C. Marker amplitude control D. Sweep output control

Last Answer : B. Phase control

Description : What component causes a generator to produce dc voltage rather than ac voltage at its output terminals?

Last Answer : A commutator

Description : A shunt generator develops stable output voltage if (A) magnetization characteristic is linear (B) magnetization characteristic is non-linear (C) the field winding resistance is more than the critical resistance (D) the residual magnetism is equal to zero

Last Answer : A shunt generator develops stable output voltage if magnetization characteristic is non-linear

Description : Tachometer works essentially as a generator with output voltage proportional to magnitude of the : - a) Angular Velocity of the shaft b) Torque of the shaft c) Temperature of the shaft d) Back Lash of the shaft

Last Answer : Tachometer works essentially as a generator with output voltage proportional to magnitude of the : - Angular Velocity of the shaft

Last Answer : In a D.C. generator in case the resistance of the field winding is increased, then output voltage will decrease.

Description : Write a step by step procedure of obtaining constant output using three brush generator.

Last Answer : Ans: Step by step procedure of obtaining constant o/p using three brush generator  1) The field is excited from one main brush X and third brush Z fixed at 90° electrical with normal axis of ... brushes XY The result is in controlling increased load and keeping o/p as far as possible as constant

Description : n electrochemical cell which is used as a source of direct electrical current at constant voltage under standard conditions is called a – (1) Power transmittor (2) Battery (3) Uninterrupted power supply (UPS) (4) Generator

Last Answer : (3) Uninterrupted power supply (UPS) Explanation: A Galvanic cell, also known as battery, is an electro-chemical cell that derives electrical energy from spontaneous redox reactions taking place within ... produce direct current. A battery is a set of galvanic cells that are connected in parallel.

Description : An open occurring within the field rheostat of an AC generator can be detected by short circuiting its terminals and observing a ____________. A. negative deflection of the wattmeter pointer B. ... of the wattmeter pointer C. buildup of alternator voltage D. low, but constant alternator voltage

Last Answer : Answer: C

Description : As load is added to an AC generator provided with constant field excitation, the prime mover slows down with the effect of ____________. A. lowering frequency and lowering generated ... C. increasing frequency and lowering generated voltage D. lowering frequency and increasing generated voltage

Last Answer : Answer: A

Description : The conversion of the throttle command voltage to the signal necessary to achieve the desired shaft RPM is accomplished by the _____________. A. ahead or astern function generator of the ... circuit C. operational amplifiers in the autorotation circuit D. long time constant amplifier circuit

Last Answer : Answer: A

Description : An electrochemical cell which is used as a source of direct electrical current at constant voltage under standard conditions is called a : (1) Power transmittor (2) Battery (3) Uninterrupted power supply (UPS) (4) Generator

Last Answer : Battery

Description : The steady-state fault current during a 3 phase terminal fault on a generator is limited by: (1) Transient reactance of the generator (2) Sub-transient reactance of the generator (3) Synchronous reactance of the generator (4) DC off—set during the instant of the fault

Last Answer : 1

Description : The external characteristic of a shunt generator can be obtained directly from its – characteristic   1. internal 2. open-circuit 3. load-saturation 4. Performance 

Last Answer : The external characteristic of a shunt generator can be obtained directly from its open-circuit characteristic

Description : A 200 V DC machine supplies 20 A at 200 V as a generator. The armature resistance is 0.2 Ohm. If the machine is now operated as a motor at same terminal voltage and current but with the flux increased by 10%, the ratio of motor speed to generator speed is

Last Answer : A 200 V DC machine supplies 20 A at 200 V as a generator. The armature resistance is 0.2 Ohm. If the machine is now operated as a motor at same terminal voltage and current but with the flux increased by 10%, the ratio of motor speed to generator speed is 0.87

Description : A _________ is used to measure the stator % winding temperature of the generator.  (A) Thermocouple (B) Pyrometer (C) Resistance thermometer (D) Thermometer

Last Answer : A Resistance thermometer is used to measure the stator % winding temperature of the generator. 

Description : The fall in speed of a dc generator due to increase in load can be corrected by  (1) cooling the armature.. (2) increasing the excitation. (3) reducing the load voltage. (4) increasing the input to the prime mover

Last Answer : It   can  be  corrected  by  increasing  the  input  to  the  prime  mover.

Description : In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load  (A) The armature current increases and the power factor decreases  (B) The armature ... but is lagging  (D) The armature current decreases and the power factor increases and is leading

Last Answer : In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load The armature current decreases and the power factor increases and is leading

Description : In a DC generator the windings of interpoles are connected :  (A) in series with main field winding, to create a pole,of same polarity as the main pole ahead in the direction of rotation.  ... winding, to create a pole of opposite polarity as the main pole ahead in the direction of rotation.

Last Answer : In a DC generator the windings of interpoles are connected :  in series with the armature winding, to create a pole of same polarity as the main pole ahead in the direction of rotation. 

Description : In a synchronous generator delivering lagging power factor load  (1) the excitation emf leads terminal voltage by the power angle (2) the excitation emf lags terminal voltage by the power angle (3) ... by the power factor angle (4) excitation emf lags the terminal voltage by the power factor angle

Last Answer : In a synchronous generator delivering lagging power factor load the excitation emf leads terminal voltage by the power angle

Description : The power factor angle and torque angle of a salient pole synchronous generator drawing a current of 1.0 pu from a lagging load are 45o and 15o, respectively. The direct axis and quadrature axis currents, respectively, are (A) 0.5 pu ... pu, 0.5 pu (C) 0.707 pu, 0.707 pu (D) 0.5 pu, 0.5 pu

Last Answer : The power factor angle and torque angle of a salient pole synchronous generator drawing a current of 1.0 pu from a lagging load are 45o and 15o, respectively. The direct axis and quadrature axis currents, respectively, are 0.866 pu, 0.5 pu

Description : The armature reaction in a synchronous generator supplying leading power factor load is (A) magnetizing (B) demagnetizing (C) demagnetizing and cross-magnetizing (D) magnetizing and cross-magnetizing

Last Answer : The armature reaction in a synchronous generator supplying leading power factor load is magnetizing and cross-magnetizing

Description : What is the difference between an AC and DC generator?

Last Answer : The generator which generates DC voltage is called DC generator and generator which generates AC voltage is called AC generator (or) Alternator. In DC generator armature is rotated and field winding ... generator. A DC generator can generate low voltages but an AC generator can generate upto 11kv.

Description : What is the principle of DC generator?

Last Answer : principle

Description : From which material field coils of DC generator are made of?

Last Answer : Field coils of DC generator are usually made of copper.

Description : Why is the armature of DC generator laminated?

Last Answer : The armature of DC generator is laminated to reduce eddy current losses.

Description : What are the main parts of a generator?

Last Answer : the main parts of the generator are as follows yoke Armature Poles field winding Prime mover  Commutator Shaft Bearings Brushes

Last Answer : if induction motor rotates exceed than its synchronous speed, it acts as a generator.

Description : 48.During light loads, the transformer efficiency is low because A. Secondary output is low B. Transformer losses are high C. Fixed loss is high in proportion to the output D. Cu loss is small

Last Answer : C. Fixed loss is high in proportion to the output

Last Answer : The plugging gives the highest torque braking.

Last Answer : Speed control by Ward Leonard method gives uniform speed variation in both directions.

Description : When supplying emergency lighting loads, the storage battery initial voltage must not exceed the standard system voltage by more than _____________. A. 2% B. 3% C. 5% D. 10%

Last Answer : Answer: C

Description : Which of the following conditions is most likely to occur if a single element fuse were used to replace a blown dual element fuse in a motor controller circuit? A. The fuse will blow when the motor ... overheats at high motor loads. C. The motor runs at reduced voltage. D. The motor runs normally.

Last Answer : Answer: A

Description : Which of the following statements represents the main difference between a relay and a contactor? A. Contactors control current and relays control voltage. B. A relay is series connected and a contactor ... loads than relays. D. Contactors are made from silver and relays are made from copper.

Last Answer : Answer: C