A 4 bus power system consists of 4 transmission lines, then find  the sparsity of Y bus matrix?  
a) 0.75  
b) 0.25  
c) 0.4  
d) 0.5

1 Answer

Answer :

b) 0.25

Related questions

Description : If sparsity of a 5 bus transmission line is 0.4. Find the number of transmission lines? a) 6 b) 5 c) 4 d) 3

Last Answer : b) 5

Description : In a 4 bus,4×4 Y bus matrix the number of non zero elements are 12. Find the number of transmission lines? a) 8 b) 4 c) 2 d) 5

Last Answer : b) 4

Description : A 1000 × 1000 bus admittance matrix for an electric power system has 8000 non-zero elements. The minimum number of branches (transmission lines and transformers) in this system are _____ (up to 2 decimal places)

Last Answer : Ans: 3500.00

Description : For n bus power system size of Y bus matrix is a) n*n b) (n-1)*(n-1) c) (n-1)*(n-2) d) (n-2)*(n-2)

Last Answer : a) n*n

Description : Which of the following matrix is used for load flow studies? a) null matrix b) Unit matrix c) Z bus matrix d) Y bus matrix

Last Answer : d) Y bus matrix

Description : What technique is used to solve load flow problems using Z-bus (Bus impedance matrix)?

Last Answer : The formulation of load flow problem using Zbus employs Diakoptics techniques which is actually the piecewise solution of the power system problem by using tearing off technique.

Description : Normally Z bus matrix is a a) null matrix b) sparse matrix c) full matrix d) unit matrix

Last Answer : full matrix

Description : In power system, if a voltage controlled bus is treated as a load bus then which one of the following limits would be violated? a) Voltage b) Active power c) reactive power d) Phase angle

Last Answer : a) Voltage

Description : Mention the various types of buses in power system with specified quantities for each bus.

Last Answer : • Load bus or PQ-bus (P and Q are specified- Voltage magnitude and angle are to be obtained) • Generator bus or voltage controlled bus or PV bus (P and V are specified- Voltage angle and Q are to be obtained)

Description : In a load flow analysis of a power system, the load connected at a bus is represented as a) Constant current drawn from the bus b) Constant impedance connected at the bus c) Voltage and frequency dependent sources at the boss d) Constant real and reactive power drawn from the bus

Last Answer : d) Constant real and reactive power drawn from the bus

Description : In load flow studies of a power system, a voltage control bus is specified by a) Real power and reactive power b) Reactive power and voltage magnitude c) Voltage and voltage phase angle d) Real power and voltage magnitude

Last Answer : d) Real power and voltage magnitude

Description : What is the need for slack bus in power flow analysis.

Last Answer : The slack/swing bus is needed to account for transmission line losses. In a power system the total power generated will be equal to sum of power consumed by loads and losses. In a power ... power are not specified for slack bus. They are estimated through the solution of load flow equations.

Description : The voltage of a particular bus can be controlled by controlling the a) Active power of the bus b) Reactive power of the bus c) Phase angle d) All of the above

Last Answer : b) Reactive power of the bus

Description : What is jacobian matrix?

Last Answer : The Jacobian matrix gives the linearized relationship between small changes in voltage angle or voltage magnitude with a small changes in real and reactive power.

Description : A network containing 50 buses in which 10 are the voltage control buses, 6 are the generator buses. Find the size of the Jacobian matrix. a) 84*84 b) 83*83 c) 34*34 d) 33*33

Last Answer : b) 83*83

Description : What are the four quantities that are associated with each bus in a system?

Last Answer : • Real Power • Reactive Power • Voltage magnitude • Phase angle of voltage

Description : In a load flow problem solved by newton-Raphson method with polar coordinates, the size of the Jactobian is 100 × 100. If there are 20 PV buses in addition to PQ buses and a slack bus, the total number of buses in the system is_____

Last Answer : 61

Description : Define voltage-controlled bus and load bus.

Last Answer : LOAD BUS A bus is called PQ bus or load bus when real and reactive components of power are specified for the bus. In a load bus the voltage is allowed to vary within permissible limits ... constant using automatic voltage regulator, we can specify constant PGi and | Vi | for these buses.

Description : When will the generator bus is treated as load bus.

Last Answer : If the reactive power of a generator bus violates the specified limits then the generator bus is treated as load bus.

Description : Which of the following quantities are to be calculated for generator bus a) P and V b) V and δ c) δ and Q d) Q and P

Last Answer : c) δ and Q

Description : Specified quantities of load bus are a) P and Q b) V and δ c) P and δ d) Q and V

Last Answer : a) P and Q

Description : The value of off diagonal elements is a) sum of admittances connected at bus j b) which is connected between bus i and bus j with positive sign c) which is connected between bus i and bus j with negative sign d) sum of admittances connected at bus i

Last Answer : c) which is connected between bus i and bus j with negative sign

Description : um of the elements of row i equal to shunt admittances connected to bus i. If this summation is zero, indicates there is no a) shunt admittance b) mutual coupling c) both 1 and 2 d) none of the above

Last Answer : c) both 1 and 2

Description : For load flow studies, what are the quantities specified at load bus are. a) P and V b) P and Q c) V and δ d) δ and Q

Last Answer : b) P and Q

Description : A power system has 100 buses including 10 generator buses. For the load flow analysis using Newton-Raphson method in polar coordinates, the size of the Jacobian is a) 189x189 b) 100x100 c) 90x90 d) 180x180

Last Answer : a) 189x189

Description : In power system, the maximum number of buses are a) Generator buses b) Load buses c) Slack buses d) P-V buses

Last Answer : b) Load buses

Description : Advantage of Gauss-Seidel method is a) applicable for large power system network b) calculation time for each iteration is less c) number of iterations are less d) all of the above

Last Answer : b) calculation time for each iteration is less

Description : Determine the correctness or otherwise of the following Assertion [a] and the Reason [r]. Assertion: Fast decoupled load flow method gives approximate load flow solution because it uses several assumptions. Reason: Accuracy ... the correct reason for [a]. c) [a] is false and [r] is true.

Last Answer : c) [a] is false and [r] is true

Description : or accurate load flow calculations on large power systems, the best method is a) N-R method b) G-S method c) Decoupled method d) all of the above

Last Answer : a) N-R method

Description : Explain Flat Voltage start.

Last Answer : In iterative methods of load flow solution, the initial voltages of all buses except slack bus are assumed as 1+j0 p.u. This is referred to as flat voltage start.

Description : What are the advantages of FDLF method.

Last Answer : FDLF method is faster, simple to program, more reliable and requires less memory than NR load flow method. FDLF method requires more iteration than N-R method, but requires less time per iteration.

Description : What are the disadvantages of NR method.

Last Answer : • The programming is more complex. • The memory requirement is more. • Computational time per iteration is higher due to large number of calculations per iteration.

Description : Discuss the effect of acceleration factor in the load flow solution algorithm.

Last Answer : An acceleration factor is a value that can be used to speed up the convergence and reduce the number of required alteration in a Gauss Seidel method of power flow analysis .Very high or very ... trial and error load flow analysis. A generally recommended value of the acceleration factor is 1.6.

Description : What is the need for load flow analysis.

Last Answer : The load flow study of a power system is essential to decide the best operation of existing system and for planning the future expansion of the system. It is also essential for designing a new power system.

Description : Mention any three advantages of N-R method over G-S method.

Last Answer : • The N-R method has quadratic convergence characteristic and so convergence faster than G-S method. • The number of iterations for convergence is independent of the size of the system in N-R method. • In N-R method the convergence is not affected by the choice of slack bus.

Description : What is the information that are obtained from a load flow study.

Last Answer : • The magnitude and phase of bus voltages, real and reactive power flowing in each line and the line losses. • The load flow solution also gives the initial conditions of the system when the transient behavior of the system is to be studied.

Description : SparseEfficiencyWarning: Changing the sparsity structure of a csr_matrix is expensive. lil_matrix is more efficient. -Web-Development

Last Answer : answer:

Description : If a 5-bus test system contains 6 transmission lines and one transformer, how many non-zero elements are there in the system Y-bus ? (A) 25 (B) 12 (C) 11 (D) 19

Last Answer : If a 5-bus test system contains 6 transmission lines and one transformer, 19 non-zero elements are there in the system Y-bus.

Description : The area of the triangular region, in the following figure, bounded by the lines 2x-y=1 and x+2y=13 and Y-axis is (a) 11.25 sq.units (b) 9.75 sq.units (c) 16.25 sq,units (d) 18.75 sq.units

Last Answer : (a) 11.25 sq.units

Description : Which of the following transmission systems provide the highest data rate to in individual device? a. computer bus b. telephone lines c. voice and mode d. lease lines

Last Answer : computer bus

Description : In most Wide Area Networks, the subnet consists of two distinct components: which are they? A. Transmission Lines and Switching Elements. B. host and subnet C. Transmission Lines and host D. subnet and Switching Elements.

Last Answer : A. Transmission Lines and Switching Elements.

Description : A bus can travel 25% faster than a van. Both start from a certain shop at the same time and reach poin P, 37.5 kms away from the shop at the same time time. On the way, however, the bus lost about 6.25 mins while shopping at the some such places. The speed of the van is. a) 72 b) 73 c) 74 d) 75 

Last Answer : A Let speed of the car be x kmph The speed of the train = 125x/100 =5x/4 km/hr Therefore 37.5 / x – 37.5 /(5x/4) = 6.25 /60 37.5 / x – (37.5*4)/5x = 6.25 / 60 37.5 / x – 150 / 5x = 6.25 / 60 37.5 / x – 30/x = 6.25 / 60 7.5 / x = 6.25 / 60 6.25x = 7.5*60 X=72 km/hr

Description : For a 15-bus power system with 3 voltage controlled buses, the size of Jacobian matrix is

Last Answer : For a 15-bus power system with 3 voltage controlled buses, the size of Jacobian matrix is 25 x 25

Description : The minimum impedance of a 75 ohm transmission line with a SWR of 2.5 is a) 100 b) 50 c) 25 d) 30

Last Answer : d) 30

Description : A cylinder rotor generator delivers 0.5 pu power in the steady-state to an infinite bus through a transmission line of reactance 0.5 pu. The generator no-load voltage is 1.5 pu and the infinite bus voltage is 1 pu. The ... fault at the generator terminal is  (A) 53.5 (B) 60.2 (C) 70.8 (D) 79.6

Last Answer : A cylinder rotor generator delivers 0.5 pu power in the steady-state to an infinite bus through a transmission line of reactance 0.5 pu. The generator no-load voltage is 1.5 pu and the ... clearing angle, in degrees, for a three-phase dead short circuit fault at the generator terminal is 79.6

Description : Write the four ways of adding an impedance to an existing system so as to modify bus impedance matrix.

Last Answer : 1. Adding a branch of impedanceZb from a new bus p to the referance bus. 2. Adding a branch of impedance Zb from a new busp to an existing bus. 3. Adding a branch of impedance Zb from an existing busq to the referance bus. 4. Adding a branch of impedance Zb between two existing buses h and q.

Description : Dot Matrix is a type of (a) Tape (b) Disk (c) Printer (d) Bus -Technology

Last Answer : (c) Dot matrix is a type of impact printer that prints one character at a time.

Description : Dot-matrix is a type of A) Tape B) Printer C) Disk D) Bus

Last Answer : Answer : B