Relays can be designed to respond to changes in
(a) resistance, reactance or impedance
(b) voltage and current
(c) light intensity
(d) temperature
(e) all above

1 Answer

Answer :

(e) all above

Related questions

Description : Distance relays are generally (a) split-phase relays (b) reactance relays (c) impedance relays (d) none of the above

Last Answer : (d) none of the above

Description : relays are used for phase faults on long line. (a) Impedance (b) Reactance (c) Either of the above (d) None of the above

Last Answer : (a) Impedance

Description : Induction cup relay is operated due to changes in (a) current (b) voltage (c) impedance (d) all of the above

Last Answer : (d) all of the above

Description : relay is preferred for phase fault on short transmission line. (a) Induction type (b) Reactance (c) Impedance (d) None of the above

Last Answer : (b) Reactance

Description : Arc in a circuit behaves as (a) a capackive reactance (b) an inductive reactance (c) a resistance increasing with voltage rise across the arc (d) a resistance decreasing with voltage rise across the arc

Last Answer : (d) a resistance decreasing with voltage rise across the arc

Description : Protective relays are devices that detect abnormal conditions in electrical circuits by measuring (a) current during abnormal condition (b) voltage during abnormal condition (c) constantly the electrical quantities which differ during normal and abnormal conditions (d) none of the above

Last Answer : (c) constantly the electrical quantities which differ during normal and abnormal conditions

Description : Directional relays are based on flow of (a) power (b) current (c) voltage wave (d) all of the above

Last Answer : (a) power

Description : Which of the following devices will receive voltage surge first travelling on the transmission line ? (a) Lightning arresters (b) Relays (c) Step-down transformer (d) Switchgear

Last Answer : (a) Lightning arresters

Description : Series capacitors are used to (a) compensate for line inductive reactance (b) compensate for line capacitive reactance (c) improve line voltage (d) none of the above

Last Answer : (a) compensate for line inductive reactance

Description : Which of the following parameter can be neglected for a short line ? (a) Inductance (b) Capacitance (c) Resistance (d) Reactance

Last Answer : (b) Capacitance

Description : The inverse definite mean time relays are used for over current and earth fault protection of transformer against (a) heavy loads (b) internal short-circuits (c) external short-circuits (d) all of the above

Last Answer : (b) internal short-circuits

Description : Thermal overload relays are used to protect the motor against over current due to (a) short-circuits (b) heavy loads (c) grounds (d) all of the above

Last Answer : (b) heavy loads

Description : Large internal faults are protected by (a) merz price percentage differential protection (b) mho and ohm relays (c) horn gaps and temperature relays (d) earth fault and positive sequence relays

Last Answer : (a) merz price percentage differential protection

Description : Which of the following statements is incorrect ? (a) Lightning arrestors are used before the switchgear (b) Shunt reactors are used as compensation reactors (c) The peak short current is (1.8 xV2) ... component (d) The MVA at fault is equal to base MVA divided by per unit equivalent fault reactance

Last Answer : (a) Lightning arrestors are used before the switchgear

Description : Series reactors should have (a) low resistance (b) high resistance (c) low impedance (d) high impedance

Last Answer : (a) low resistance

Description : Overload relays are of...... type. (a) induction (b) solid state (c) thermal (d) electromagnetic (e) all above

Last Answer : (e) all above

Description : Which of the following statements is incorrect? (a) Station batteries are used to operate relay only (b) The lightning arresters are basically surge diverters (c) An impedance relay has maximum fault current when fault occurs near the relay (d) A high speed relay has an operation of 1 to 2 cycles

Last Answer : (a) Station batteries are used to operate relay only

Description : The single phasing relays are used for the protection of (a) single phase motors only (b) two phase motors only (c) two single phase motors running in parallel (d) three phase motors

Last Answer : (d) three phase motors

Description : Discrimination between main and back up protection is provided by the use of relays which are (a) fact (b) sensitive (c) slow (d) none of the above

Last Answer : (c) slow

Description : To protect most of the electrical equipment handling low power, the types of relays used are (a) thermocouple (b) electronic and bimetallic (c) both (a) and (b) (d) none of the above

Last Answer : (c) both (a) and (b)

Description : D.C. shunt relays are made of (a) few turns of thin wire (b) few turns of thick wire (c) many turns of thin wire (d) many turns of thick wire

Last Answer : (c) many turns of thin wire

Description : Fault diverters are basically (a) fuses (b) relays (c) fast switches (d) circuit breakers

Last Answer : (c) fast switches

Description : In order that current should flow without causing excessive heating or voltage drop, the relay contacts should (a) have low contact resistance (b) be clean and smooth (c) be of sufficient size and proper shape (d) have all above properties

Last Answer : (d) have all above properties

Last Answer : Relays can be designed to respond to changes in resistance, reactance or impedance voltage and current, light intensity, temperature.

Description : Admittance relay is _______ relay. (a) impedance (b) directional (c) non-directional (d) none of the above

Last Answer : (b) directional

Description : What will be the reflection coefficient of the wave of load connected to transmission line if surge impedance of the line is equal to load ? (a) Zero (b) Unity (c) Infinity (d) None of the above

Last Answer : (a) Zero

Description : Which of the following relays is used on long transmission lines ? (a) Impedance relay (b) Mho's relay (c) Reactance relay (d) None of the above

Last Answer : (b) Mho's relay

Description : Resistance grounding is used for voltage between (a) 33kVto66kV (b) HkVto33kV (c) 3.3kVandllkV (d) none of the above

Last Answer : (c) 3.3kVandllkV

Description : Insulation resistance of high voltage circuit breakers is more than (a) 1 mega ohms (b) 10 mega ohms (c) 100 mega ohms (d) 500 mega ohms

Last Answer : (c) 100 mega ohms

Description : Arc in a circuit breaker is interrupted at (a) zero current (b) maximum current (c) minimum voltage (d) maximum voltage

Last Answer : (a) zero current

Description : The arc voltage produced in A.C. circuit breaker is always (a) in phase with the arc current (b) lagging the arc current by 90" (c) leading the arc current by 90° (d) none of the above

Last Answer : (a) in phase with the arc current

Description : When a transmission line is energized, the wave that propagates on it is (a) current wave only (b) voltage wave only (c) both (a) and (b) (d) power factor wave only

Last Answer : (c) both (a) and (b)

Description : Air blast circuit breakers for 400 kV power system are designed to operate in (a) 100 microsecond (b) 50 millisecond (c) 0.5 sec (d) 0.1 sec

Last Answer : (b) 50 millisecond

Description : An efficient and a well designed protective relaying should have (a) good selectivity and reliability (b) economy and simplicity (c) high speed and selectivity (d) all of the above

Last Answer : (d) all of the above

Description : A thermal protection switch can protect against (a) short-circuit (b) temperature (c) overload (d) over voltage

Last Answer : (c) overload

Description : A _______ is used to measure the stator % winding temperature of the generator. (a) thermocouple (b) pyrometer (c) resistance thermometer (d) thermometer

Last Answer : (c) resistance thermometer

Description : Over voltage protection is recommended for (a) hydro-electric generators (b) steam turbine generators (c) gas turbine generators (d) all of the above (e) none of the above

Last Answer : (d) all of the above

Description : The under voltage relay can be used for (a) generators (b) busbars (c) transformers (d) motors (e) all of the above

Last Answer : (e) all of the above

Description : The contacts of high voltage switches used in power system are submerged in oil. The main purpose of the oil is to (a) lubricate the contacts (b) insulate the contacts from switch body (c) extinguish the arc (d) all of the above (e) none of the above

Last Answer : (c) extinguish the arc

Description : Which of the following is the least expensive protection for overcurrent is low voltage system ? (a) Rewireable fuse (b) Isolator (c) Oil circuit breaker (d) Air break circuit breaker (e) None of the above

Last Answer : (a) Rewireable fuse

Description : The voltage appearing across the contacts after opening of the circuit breaker is called______voltage. (a) recovery (b) surge (c) operating (d) arc (e) none of the above

Last Answer : (a) recovery

Description : What is re-striking voltage?

Last Answer : The Re-striking voltage may be defined as the resultant transient voltage which appears across the breaker contacts at the instant of arc extinction

Description : What is recovery voltage in circuit breaker?

Last Answer : Recovery voltage in circuit breakers is defined as the power frequency rms voltage which appears across the breaker contacts after the transient oscillations die out and the final extinction of the arc ... poles of the circuit breaker. It is the voltage developed after the arc extinction is competed

Description : The short circuit in any winding of the transformer is the result of (a) mechanical vibration (b) insulation failure (c) loose connection (d) impulse voltage

Last Answer : (d) impulse voltage

Description : Decreasing the frequency in a capacitive circuit while maintaining a constant circuit voltage, will result in a/an _____________. A. increase in apparent power B. decrease in circuit current C. decrease in capacitive reactance D. decrease in total impedance

Last Answer : Answer: B

Description : The material used for fuse must have (a) low melting point and high specific resistance (b) low melting point and -low specific resistance (c) high melting point and low specific resistance (d) low melting point and any specific resistance

Last Answer : (a) low melting point and high specific resistance

Description : A transmission line is protected by (a) inrush protection (b) distance protection (c) time graded and current graded over current protection (d) both (b) and (c) (e) none of the above

Last Answer : (d) both (b) and (c)

Description : The current zero interruption, in oil and air blast circuit breakers, is achieved by (a) lengthening of the gap (b) cooling and blast effect (c) both (a) and (b) (d) deionizing the oil with forced air (e) none of the above

Last Answer : (c) both (a) and (b)

Description : Circuit breakers are essentially (a) current carrying contacts called electrodes (b) arc extinguishers (c) circuits to break the system (d) transformers to isolate the two systems (e) any of the above

Last Answer : (a) current carrying contacts called electrodes

Description : The delay fuses are used for the protection of ________ . (a) motors (b) power outlet circuits (c) fluorescent lamps (d) light circuits

Last Answer : (a) motors