In a single phase induction motor driving a fan load, the reason for having a high resistance rotor is to achieve (A) low starting torque (B) quick acceleration (C) high efficiency (D) reduced size

1 Answer

Answer :

In a single phase induction motor driving a fan load, the reason for having a high resistance rotor is to achieve quick acceleration

Related questions

Description : The type of single-phase induction motor having the highest power factor at full load is (A) shaded pole type (B) split-phase type (C) capacitor-start type (D) capacitor-run type

Last Answer : The type of single-phase induction motor having the highest power factor at full load is capacitor-run type

Description : A 3-phase induction motor is driving a constant torque load at rated voltage and frequency. If both voltage and frequency are halved, following statements relate to the new condition if stator resistance, leakage reactance and core loss are ... (A) All (B) 1, 2 and 3 (C) 2, 3 and 4 (D) 1 and 4

Last Answer : A 3-phase induction motor is driving a constant torque load at rated voltage and frequency. If both voltage and frequency are halved, following statements relate to the new condition if stator resistance, leakage reactance and core loss are ... A) All (B) 1, 2 and 3 (C) 2, 3 and 4 (D) 1 and 4

Description : A single-phase induction motor having a relatively high starting torque, is the ___________. A. shaded pole motor B. wound-rotor motor C. capacitor-start motor D. resistance-start motor

Last Answer : Answer: C

Description : The stator mmf and rotor mmf of a 3-phase induction motor (A) are equal (B) rotate with slip speed (C) are opposite but rotate with synchronous speed (D) rotate with the same rotor speed 

Last Answer : a

Description : The rotor frequency for a 3-phase 6-pole, 1000 r.p.m. induction motor with a slip of 0.04 is (a) 2 Hz (b) 4 Hz (c) 6 Hz (d) 8 Hz  

Last Answer : 2hz is rotor frequency

Description : If a 3-phase, 400V, 50Hz, 4 pole induction motor is running at a slip of 5% then the relative speed of rotor field with respect to stator filed is:

Last Answer : If a 3-phase, 400V, 50Hz, 4 pole induction motor is running at a slip of 5% then the relative speed of rotor field with respect to stator filed is: zero

Description : A three phase slip ring induction motor is fed from the rotor side with stator winding short circuited stator is: (1) Slip frequency (2) Supply frequency (3) Frequency corresponding to rotor speed (4) Zero

Last Answer : A three phase slip ring induction motor is fed from the rotor side with stator winding short circuited stator is: Slip frequency

Description : in a three-phase induction motor, the rotor field runs at the following speed with respect to the stator structure: 

Last Answer : in a three-phase induction motor, the rotor field runs at the following speed with respect to the stator structure: At synchronous speed in the direction of stator field

Last Answer : The rotor developed by a single-phase motor at starting is zero.

Description : A single-phase induction motor fails to start. The rotor is spun rapidly with the line switch closed. Having started by this method it is noted that the motor fluctuates between a very slow ... lies in the ______ A. starting winding B. centrifugal mechanism C. centrifugal switch D. running winding

Last Answer : Answer: D

Description : An 8 pole wound rotor induction motor operating on 60 Hz supply is driven at 1800 r.p.m. by a prime mover in the opposite direction of revolving magnetic field. The frequency of the rotor current is (a) 30 Hz (b) 60 Hz (c) 120 Hz (d) 180 Hz 

Last Answer : 30 Hz As the frequency of the rotor is given by  F= N*P/120 so from the above equation the frequency of the rotor current can be easily calculated  i.e. 1800×8/120=30 Hence the required value of rotor frequency is 30 Hz

Description : A 6-pole, 50Hz, 3-φ induction motor is running at 950 r.p.m. and has Cu loss of 5kW. The rotor input is (a) 10 kW (b) 95 kW (c) 100 kW (d) 9.5 kW 

Last Answer : s=(Ns-N)/Ns =(1000-950)/1000=0.05.rotor cu.loss= s*rotor inputwe have rotor cu loss=5kWtherefore, rotor input= rotor cu.loss/s                              =5kW/0.05                              =100 kW

Description : The ratio of rotor output to rotor input in an induction motor is 0.96. The slip of the motor is (a) 0.04% (b) 4% (c) 6% (d) 12%

Last Answer : The ratio of rotor output to rotor input in an induction motor is 0.96. The slip of the motor is 4%

Description : The frequency (fr) of the rotor current in an induction motor is given by the expression (s = slip, f = supply frequency)

Last Answer : The frequency (fr) of the rotor current in an induction motor is given by the expression fr = (s. f ) (s = slip, f = supply frequency)

Description : Deep bar rotor construction is used in three phase induction motors to mainly: (1) Control speed (2) Control power factor (3) Increase starting torque (4) None of these

Last Answer : Deep bar rotor construction is used in three phase induction motors to mainly: Increase starting torque

Description : No-load test on a 3-phase induction motor was conducted at different supply voltage and a plot of input power versus voltage was drawn. This curve was extrapolated to intersect the y-axis. The intersection point ... ) Core loss (B) Stator copper loss (C) Stray load loss (D) Friction and windage loss

Last Answer : No-load test on a 3-phase induction motor was conducted at different supply voltage and a plot of input power versus voltage was drawn. This curve was extrapolated to intersect the y-axis. The intersection point yields Friction and windage loss

Description : A three phase slip ring induction motor with chopper controlled resistance has its torque proportional to   (a) Rotor current (b) Stator resistance (c) Square of rotor current (d) Square root of rotor current 

Last Answer : A three phase slip ring induction motor with chopper controlled resistance has its torque proportional to Square of rotor current

Description : A single-phase induction motor with only the main winding excited would exhibit the following response at synchronous speed  (A) Rotor current is zero (B) Rotor current is non-zero and is ... and backward rotating fields are equal (D) Forward rotating field is more than the backward rotating field

Last Answer : A single-phase induction motor with only the main winding excited would exhibit the following response at synchronous speed  (A) Rotor current is zero (B) Rotor current is non-zero and is ... backward rotating fields are equal (D) Forward rotating field is more than the backward rotating field

Description : For a single phase capacitor start induction motor, which of the following statements is valid?  A) The capacitor is used for power factor improvement B) The direction of rotation can be ... rotation cannot be changed D) The direction of rotation can be changed by interchanging the supply terminals

Last Answer : For a single phase capacitor start induction motor, which of the following statements is valid?  A) The capacitor is used for power factor improvement B) The direction of rotation can be ... cannot be changed D) The direction of rotation can be changed by interchanging the supply terminals

Last Answer : Single phase induction motor usually operates on 0.6 power factor lagging.

Last Answer : A single-phase induction motor is inherently non-self-starting with low torque.

Last Answer : The power factor of a single-phase induction motor is usually lagging.

Description : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will?

Last Answer : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will not start at all.

Description : An induction motor having full load torque of 60 Nm when delta connected develops a starting torque of 120 Nm. For the same supply voltage if the motor is changed to star connection, the starting torque developed will be  A) 40 Nm B) 60 Nm C) 90 Nm D) 120 Nm

Last Answer : An induction motor having full load torque of 60 Nm when delta connected develops a starting torque of 120 Nm. For the same supply voltage if the motor is changed to star connection, the starting torque developed will be 40 Nm

Description : The torque and current curves for a three-phase induction motor with a cage rotor, are shown in the illustration. Which of the following statements is true concerning the depicted curves? EL-0056 A. As slip ... D. If the motor is loaded to the point where 40% slip has resulted, it will stall.

Last Answer : Answer: D

Description : A split-phase induction squirrel-cage motor will not come up to speed, even though the rated voltage, rated frequency, and rated load are applied. The suspected trouble could be due to _____________. A. a faulty centrifugal switch B. broken rotor bars C. worn bearings D. all of the above

Last Answer : Answer: D

Description : The frequency of the rotor current in a 3 phase 50 Hz, 4 pole induction motor at full load speed is about (A) 50 Hz. (B) 20 Hz. (C) 2 Hz. (D) Zero.

Last Answer : (C) 2 Hz.

Description : The speed of a three-phase squirrel-cage induction-type motor operating in a fixed frequency system is varied by changing the _____________. A. number of phases to the motor B. number of stator poles C. locked rotor current D. resistance of the rotor winding

Last Answer : Answer: B

Description : The variable resistance placed in the rotor circuit of a wound-rotor induction motor provides for __________. A. speed control B. frequency control C. voltage control D. use as a split-phase motor

Last Answer : Answer: A

Description : Explain speed control method of 3 phase induction motor by the following methods: (1) Pole changing (2) Rotor resistance control (3) Stator voltage

Last Answer : 1) Pole Changing Method:  Synchronous speed is given by, From the above equation of synchronous speed, it can be seen that synchronous speed (and hence, running speed) can ... in voltage and consequently the speed decreases and vice versa. Ultimately speed depends on the supply voltage.

Description : A single-phase induction motor will only start if you spin the rotor rapidly with the line switch closed. After starting, its speed fluctuates between very slow and half-speed. The problem ... in the ________. A. starting winding B. centrifugal mechanism C. centrifugal switch D. running winding

Last Answer : Answer: D

Description : In the illustrated device, the part labeled '1A' _________. EL-0001 A. are start and run windings for a single phase shaded pole induction motor B. is the stator for a polyphase induction ... armature for a squirrel cage rotor motor D. are direct current shunt field windings for a universal motor

Last Answer : Answer: B

Description : In the illustration, the assembly labeled 2 is a ________. EL-0001 A. wound rotor and shaft for a single phase induction motor B. conduction rotor and shaft for a polyphase induction motor C. ... cage rotor and shaft for a polyphase motor D. squirrel cage rotor for a single phase induction motor

Last Answer : Answer: C

Description : In a single-phase induction motor when the rotor is stationary and voltage is applied to the stator, then (A) the flux is constant (B) the flux first decreases and then increases in ... increases and decreases in the opposite direction with the same magnitude (D) current flows through the rotor

Last Answer : In a single-phase induction motor when the rotor is stationary and voltage is applied to the stator, then the flux first decreases and then increases in the same direction

Last Answer : In a capacitor start single-phase motor, when capacitor is replaced by a resistance motor will continue to run in same direction.

Description : In the Squirrel cage induction motors, the rotor slots are usually a slight skew to reduce (A) Windage losses (B) Eddy currents (C) Accumulation of dirt and dust (D) Magnetic hum

Last Answer : Eddy   currents.

Description :  Full load current of an Induction motor is 20 Ampere. The no-load current may be expected to be: A) 25 Ampere to 28 Ampere B) 15 Ampere to 18 Ampere C) 11 Ampere to 14 Ampere D) 6 Ampere to 10 Ampere

Last Answer : D

Description : A 400 V, 15 kW, 4-pole, 50 Hz, Y-connected induction motor has full load slip of 4%. The output torque of the machine at full load is  (A) 1.66 Nm (B) 95.50 Nm (C) 99.47 Nm (D) 624.73 Nm

Last Answer : A 400 V, 15 kW, 4-pole, 50 Hz, Y-connected induction motor has full load slip of 4%. The output torque of the machine at full load is 99.47 Nm

Description : The power factor of an induction motor under no load conditions will be close to (A) 0.2 lagging (B) 0.2 leading (C) 0.5 lagging (D) Unity

Last Answer : The power factor of an induction motor under no load conditions will be close to 0.2 lagging

Description : A 3-phase delta connected squirrel cage induction motor when started with a DOL starter has a starting torque of 600 NM. Its starting torque when star delta starter is used:

Last Answer : A 3-phase delta connected squirrel cage induction motor when started with a DOL starter has a starting torque of 600 NM. Its starting torque when star delta starter is used: 200 NM

Description : In a 3-phase voltage source inverter used for speed control of induction motor, anti-parallel diodes are used across each switching device. The main purpose of diodes is to:

Last Answer : In a 3-phase voltage source inverter used for speed control of induction motor, anti-parallel diodes are used across each switching device. The main purpose of diodes is to: Allow the motor to return energy during regeneration

Description : A 3-phase induction motor is running at slip ‘s’. If its two supply leads are interchanged, then the operating slip at that instant will be:

Last Answer : A 3-phase induction motor is running at slip ‘s’. If its two supply leads are interchanged, then the operating slip at that instant will be: (2-s)

Description : The direction of rotation of a 3-phase induction motor is clockwise when it is supplied with 3-phase sinusoidal voltage having phase sequence A-B-C. For counter clockwise rotation of the motor, the phase sequence of the power supply should be  (A) B-C-A (B) C-A-B (C) A-C-B (D) B-C-A or C-A-B

Last Answer : The direction of rotation of a 3-phase induction motor is clockwise when it is supplied with 3-phase sinusoidal voltage having phase sequence A-B-C. For counter clockwise rotation of the motor, the phase sequence of the power supply should be  A-C-B 

Description : A three-phase cage induction motor is started by direct-on-line (DOL) switching at the rated voltage. If the starting current drawn is 6 times the full load current, and the full load slip is 4%, then ratio of the ... load torque is approximately equal to (A) 0.24 (B) 1.44 (C) 2.40 (D) 6.00

Last Answer : A three-phase cage induction motor is started by direct-on-line (DOL) switching at the rated voltage. If the starting current drawn is 6 times the full load current, and the full load slip is 4%, then ratio of the starting developed torque to the full load torque is approximately equal to 1.44

Description : A three-phase squirrel cage induction motor has a starting torque of 150% and a maximum torque of 300% with respect to rated torque at rated voltage and rated frequency. Neglect the stator resistance and rotational losses. The ... maximum torque is  (A) 13.48% (B) 16.42% (C) 18.92% (D) 26.79%

Last Answer : A three-phase squirrel cage induction motor has a starting torque of 150% and a maximum torque of 300% with respect to rated torque at rated voltage and rated frequency. Neglect the stator resistance and rotational losses. The value of slip for maximum torque is 26.79%

Description : A 4-pole induction motor, supplied by a slightly unbalanced three-phase 50 Hz source, is rotating at 1440 rpm. The electrical frequency in Hz of the induced negative sequence current in the rotor is  (A) 100 (B) 98 (C) 52 (D) 48

Last Answer : A 4-pole induction motor, supplied by a slightly unbalanced three-phase 50 Hz source, is rotating at 1440 rpm. The electrical frequency in Hz of the induced negative sequence current in the rotor is 98 

Description : Consider the following statements: Star delta starter is used in 3-phase induction motor because it  1. Prevents heating of the motor winding  2. Ensures permissible minimum starting current  3. Is regulated by electricity ... and 4 are correct (c) 1, 3 and 4 are correct (d) 1 and 2 are correct 

Last Answer : Consider the following statements: Star delta starter is used in 3-phase induction motor because it  1. Prevents heating of the motor winding  2. Ensures permissible minimum starting current  3. Is regulated by ... and 4 are correct (c) 1, 3 and 4 are correct (d) 1 and 2 are correct 

Description : The number of poles in a phase induction motor at 50 Hz and running at 1500 rpm will be?

Last Answer : The number of poles in a phase induction motor at 50 Hz and running at 1500 rpm will be 4.

Description : A three phase induction motor is driving full -load torque which is independent of speed. If the line voltage drops to 90% of the rated value, % increase in motor copper losses  (a) 23% (b) -18% (c) 123% (d) None of these

Last Answer : A three phase induction motor is driving full -load torque which is independent of speed. If the line voltage drops to 90% of the rated value, % increase in motor copper losses (a) 23% (b) -18% (c) 123% (d) None of these

Description : A characteristic of a wound-rotor induction motor, with a high resistance rotor winding, is _____________. A. low starting torque B. high starting torque C. high speed D. low starting voltage