The pressure coil of a dynamometer type wattmeter is 

A) Highly inductive B) Highly resistive C) Purely resistive D) Purely inductive

4 Answers

Answer :

The pressure coil of a dynamometer type wattmeter is Highly resistive

Answer :

Answer :

b

Answer :

highly resistive

Related questions

Description :  In dynamometer type of wattmeter, which of the coil is split up into two parts?

Last Answer :  In dynamometer type of wattmeter, which of the coil is split up into two parts?  current coil

Last Answer : The resistance in the circuit of the moving coil of a dynamometer wattmeter should be high.

Last Answer : A dynamometer wattmeter can be used for both D.C. and A.C.

Description : Moving coil in dynamometer wattmeter connected a) In series with fixed coil b) Across supply c) In series with load d) Across load

Last Answer : Ans: Across supply

Description : The potential coil of a single phase dynamometer wattmeter has 4840 Ohm resistance. Voltage across the load is 220 V. With the potential coil connected on the load side, the meter indicates 100 W. Approximate percentage error due to wattmeter connection is (A) 11% (B) 9% (C) 1.1% (D) 3%

Last Answer : The potential coil of a single phase dynamometer wattmeter has 4840 Ohm resistance. Voltage across the load is 220 V. With the potential coil connected on the load side, the meter indicates 100 W. Approximate percentage error due to wattmeter connection is 11%

Description :  Moving coil in dynamometer wattmeter connected : - a) in series with fixed coil b) across supply c) in series with load d) across load

Last Answer : Moving coil in dynamometer wattmeter connected : - across supply

Last Answer : In a low power factor wattmeter the pressure coil is connected to the load side of the current coil.

Last Answer : The pressure coil of a wattmeter should be connected on the supply side of the current coil when load impedance is high.

Description : Consider the following statements  1) The compensating coil of a low power factor wattmeter compensates the effect of the impedance of the current coil ii) The compensating coil of a low power factor wattmeter compensates the effect ... C) Both (i) and (ii) are true D) Both (i) and (ii) are false

Last Answer : A

Description : The current coil of a wattmeter is connected to the CT of R-phase. The potential coil is connected across Y and B phases. The wattmeter measures

Last Answer : The current coil of a wattmeter is connected to the CT of R-phase. The potential coil is connected across Y and B phases. The wattmeter measures Reactive power of R phase.

Last Answer : In a low power factor wattmeter the compensating coil is connected in series with pressure coil.

Description : Draw and explain the circuit diagram for measurement of single phase power using dynamometer type wattmeter. 

Last Answer : Circuit diagram for measurement of single phase power using dynamometer type wattmeter: Explanation: It consists of two stationary coils, called current coils and one moving coil, called voltage or ... i.e. power. The meter can be calibrated directly to indicate the power in watts. 

Description : State the effects of errors in dynamometer type wattmeter due to i) pc- inductance ii) pc- capacitance iii) mutual inductance iv) Connection.

Last Answer : Errors in wattmeter:  i) pc - inductance: Pressure coil inductance causes wattmeter to read more power than actual .  ii) pc-capacitance: The wattmeter reads less power.  iii) ... iv) Connection: In uncompensated wattmeter , the reading of wattmeter includes the powerloss in coils. 

Description : State any four errors that occur in dynamometer type wattmeter

Last Answer : Errors that occur in dynamometer type wattmeter: 1. Errors due to method of connection. 2. Error due to pressure coil inductance. 3. Error due to pressure coil Capacitance. 4. Error due to mutual ... Error due to eddy currents. 7. Temperature error. 8. Error due to vibration of moving system

Description : With neat diagram explain constructional details of dynamometer type wattmeter.

Last Answer : Working Principle of Wattmeter: It consists of two stationary coils, called current coils and one moving coil, called voltage or potential coil. The moving coil is mounted on the spindle, in the gap ... experiences a force and tends to move in the direction as per Fleming's left hand rule. 

Description : Explain the error occurred due to pressure coil inductance of electrodynamometer type wattmeter. How this error is compensated?

Last Answer : For power measurement assume that the pressure coil of wattmeter is purely restitive. Hence current taken by pressure coil Ipc is in phase with voltage across the pressure coil Vpc  ... inductive reactance XL the pressure coil circuit is made purely resistive and the error is eliminated.

Last Answer : Dynamometer type moving coil instruments are provided with pneumatic damping

Last Answer : In a dynamometer 3-phase power factor meter, the planes of the two moving coils are at 120°.

Description :  In the measurement of power of balanced load by two wattmeter method in a 3-phase circuit, The readings of the wattmeters are 4 kW and 2 kW respectively, the later is being taken after reversing the connections of current coil. the ... kVAR B) 0.2 & 6 √3 kVAR C) 0.32 & 2 kVAR D) 0.32 & 2 √3 kVAR

Last Answer :  In the measurement of power of balanced load by two wattmeter method in a 3-phase circuit, The readings of the wattmeters are 4 kW and 2 kW respectively, the later is being taken after reversing the ... of current coil. the power factor and reactive power of the load is 0.2 & 6 √3 kVAR

Description : While measuring power in a three phase load by two wattmeter method, the reading of two wattmeter are equal and opposite, when (a) load is balanced (b) power factor is unity (c) phase angle is between 60° to 90° (d) the load is purely inductive 

Last Answer :  Option (d)  Load is purely inductive 

Description : For power measurement of three phase circuit by two wattmeter method, when the value of power factor is less than 0.5 lagging:

Last Answer : For power measurement of three phase circuit by two wattmeter method, when the value of power factor is less than 0.5 lagging: One of the wattmeter connections will have to be reversed

Description : A wattmeter is connected as shown in the figure. The wattmeter reads 

Last Answer : A wattmeter is connected as shown in the figure. The wattmeter reads Power consumed by Z2

Description : The minimum number of wattmeter(s) required to measure 3-phase, 3-wire balanced or unbalanced power is  A) 1 B) 2 C) 3 D) 4

Last Answer : B

Description : Poynting vector wattmeter is based on   (A) Seebeck effect (B) Ferranti effect (C) Induction effect (D) Hall effect

Last Answer : Poynting vector wattmeter is based on Induction effect 

Description : Measurement of power and power factor of a 3-phase system by two wattmeter method can be obtained in case of  1. Balanced load and balanced source  2. Balanced source with 3-phase 3-wire unbalanced load  3. Unbalanced source with 3-phase 3 ... b) 2, 3 and 5 (c) 1, 2, 3, 4 and 5 (d) 1, 2, 3 and 5 

Last Answer : Measurement of power and power factor of a 3-phase system by two wattmeter method can be obtained in case of  1. Balanced load and balanced source  2. Balanced source with 3-phase 3-wire unbalanced load  3. Unbalanced source with 3- ... b) 2, 3 and 5 (c) 1, 2, 3, 4 and 5 (d) 1, 2, 3 and 5 

Description : In the measurement of power by two wattmeter method, when the readings of the two wattmeters are equal, the power factor is (A) Zero (B) Leading (C) Lagging (D) Unity

Last Answer : In the measurement of power by two wattmeter method, when the readings of the two wattmeters are equal, the power factor is Unity

Description : The torque produced in wattmeter is proportional to

Last Answer : A

Last Answer : In the case of power measurement by two wattmeter method in a balanced 3Φ system with a pure inductive load both the Wattmeter will indicate the same but of opposite sign.

Last Answer : Wattmeter cannot be designed on the principle of moving iron instrument.

Description : In a 3-phase power measurement by two wattmeter method the reading of one of the wattmeter was zero. The power factor of the load must be?

Last Answer : In a 3-phase power measurement by two wattmeter method the reading of one of the wattmeter was zero. The power factor of the load must be 0.5.

Description : In a 3-phase power measurement by two wattmeter method, both the watt meters had identical readings. The power factor of the load was?

Last Answer : In a 3-phase power measurement by two wattmeter method, both the watt meters had identical readings. The power factor of the load was unity.

Last Answer : An induction wattmeter can be used for A.C. 

Description : The true power indicated by a wattmeter depends on the current flow through the load, the magnitude of the potential across the load, and the _____________. A. power factor of the load B. angle of coil displacement C. inertia of the movable coil D. high resistance from the load

Last Answer : Answer: A

Description : The true power indicated by the pointer movement of a wattmeter depends on the current flow through the load, the magnitude of the potential across the load, and the ____________. A. power factor of the ... B. angle of coil displacement C. inertia of the movable coil D. high resistance from the load

Last Answer : Answer: A

Description : The basic meter movement responds to the flow of current through its coil. Therefore, this meter movement may be used as a/an _____________. A. voltmeter by placing a resistance in parallel with the ... in parallel with the coil D. ammeter by placing a low resistance in parallel with the coil

Last Answer : Answer: D

Description : Two wattmeter method is employed to measure power in a 3 -phase balanced system with the current coil connected in the A and C lines. The phase sequence is ABC. If the wattmeter with its current coil in A -phase line reads zero, then the power factor of the 3 -phase load will be

Last Answer : Two wattmeter method is employed to measure power in a 3 -phase balanced system with the current coil connected in the A and C lines. The phase sequence is ABC. If the wattmeter with its current coil in A -phase line reads zero, then the power factor of the 3 -phase load will be 0.5 lagging.

Last Answer : In a dynamo-meter type of moving coil instrument a swamping resistance is provided inorder to: Provide equal time constant for moving coil and fixed coil, when used for ac measurement

Description : The magnetic field intensity at the centre of a current carrying coil of diameter J m is K. The current flowing in the coil is

Last Answer : The magnetic field intensity at the centre of a current carrying coil of diameter d m is H. The current flowing in the coil is dH

Description : A permanent magnet moving coil ammeter has a coil resistance of 99 ohm and Full Scale Deflection (FSD) current of 0.1mA. Shunt resistance is 1 ohm. Current through the meter at 0.5 F.S.D is:

Last Answer : A permanent magnet moving coil ammeter has a coil resistance of 99 ohm and Full Scale Deflection (FSD) current of 0.1mA. Shunt resistance is 1 ohm. Current through the meter at 0.5 F.S.D is: 0.05mA

Description : A moving coil instrument has a resistance of 10 W and gives full scale deflection when carrying a current of 50 mA. To measure current upto 100 A, we will have to connect • 10 W resistance in series • 10 W resistance in parallel • 10/1999 W resistance in series • 10/1999 W resistance in parallel

Last Answer : A moving coil instrument has a resistance of 10 W and gives full scale deflection when carrying a current of 50 mA. To measure current upto 100 A, we will have to connect 10/1999 W resistance in parallel

Description : Permanent magnet moving coil instruments are used for

Last Answer : PMME are mostly used for measuring voltage and current.

Description : A moving coil of meter has 100 turns, and a length and depth of 10mm and 20mm respectively. It is positioned in a uniform radial flux density of 200 mT. The coil carrier current capacity is 50 mA. The torque on the coil is

Last Answer : A moving coil of meter has 100 turns, and a length and depth of 10mm and 20mm respectively. It is positioned in a uniform radial flux density of 200 mT. The coil carrier current capacity is 50 mA. The torque on the coil is 200µNm

Description : The self inductance of a coil can be measured using (A) Wien’s Bridge (B) Schering Bridge (C) Anderson’s Bridge (D) Wheatstone Bridge

Last Answer : The self inductance of a coil can be measured using Anderson’s Bridge

Description : A PMMC instrument has FSD of 100 μA and a coil resistance of 1 kΩ. To convert the instrument into an ammeter with full scale deflection of 100 mA, the required shunt resistance is (A) 1 Ω (B) 1.001 Ω (C) 0.5 Ω (D) 10 Ω

Last Answer : A PMMC instrument has FSD of 100 μA and a coil resistance of 1 kΩ. To convert the instrument into an ammeter with full scale deflection of 100 mA, the required shunt resistance is 1.001 Ω

Last Answer :  In a moving coil instrument, the deflecting torque is proportional to Current.

Last Answer : A moving coil instrument is used as an ohmmeter. The indicating scale of the meter will be Hyperbolic.

Last Answer : In moving coil meters, damping is provided by eddy current disk.

Last Answer : In Weston synchronoscope the moving coil is connected across bus-bars.

Last Answer : The multiplier and the meter coil in a voltmeter are in series.

Last Answer : A moving-coil permanent-magnet instrument can be used as flux-meter by eliminating the control springs.