A 3-phase induction motor is running at slip ‘s’. If its two supply leads are interchanged, then the operating slip at that instant will be:

1 Answer

Answer :

A 3-phase induction motor is running at slip ‘s’. If its two supply leads are interchanged, then the operating slip at that instant will be: (2-s)

Related questions

Description : If a 3-phase, 400V, 50Hz, 4 pole induction motor is running at a slip of 5% then the relative speed of rotor field with respect to stator filed is:

Last Answer : If a 3-phase, 400V, 50Hz, 4 pole induction motor is running at a slip of 5% then the relative speed of rotor field with respect to stator filed is: zero

Description : A three phase slip ring induction motor with chopper controlled resistance has its torque proportional to   (a) Rotor current (b) Stator resistance (c) Square of rotor current (d) Square root of rotor current 

Last Answer : A three phase slip ring induction motor with chopper controlled resistance has its torque proportional to Square of rotor current

Description : The rotor frequency for a 3-phase 6-pole, 1000 r.p.m. induction motor with a slip of 0.04 is (a) 2 Hz (b) 4 Hz (c) 6 Hz (d) 8 Hz  

Last Answer : 2hz is rotor frequency

Description : A three phase slip ring induction motor is fed from the rotor side with stator winding short circuited stator is: (1) Slip frequency (2) Supply frequency (3) Frequency corresponding to rotor speed (4) Zero

Last Answer : A three phase slip ring induction motor is fed from the rotor side with stator winding short circuited stator is: Slip frequency

Description : The frequency (fr) of the rotor current in an induction motor is given by the expression (s = slip, f = supply frequency)

Last Answer : The frequency (fr) of the rotor current in an induction motor is given by the expression fr = (s. f ) (s = slip, f = supply frequency)

Description : An 8 pole wound rotor induction motor operating on 60 Hz supply is driven at 1800 r.p.m. by a prime mover in the opposite direction of revolving magnetic field. The frequency of the rotor current is (a) 30 Hz (b) 60 Hz (c) 120 Hz (d) 180 Hz 

Last Answer : 30 Hz As the frequency of the rotor is given by  F= N*P/120 so from the above equation the frequency of the rotor current can be easily calculated  i.e. 1800×8/120=30 Hence the required value of rotor frequency is 30 Hz

Description : The reversal of an AC, three-phase, induction motor is accomplished by ______________. A. changing all three motor leads B. reversing the position of the slip rings C. interchanging any two of the three motor leads D. interchanging any two brushes

Last Answer : Answer: C

Description : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will?

Last Answer : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will not start at all.

Description : No-load test on a 3-phase induction motor was conducted at different supply voltage and a plot of input power versus voltage was drawn. This curve was extrapolated to intersect the y-axis. The intersection point ... ) Core loss (B) Stator copper loss (C) Stray load loss (D) Friction and windage loss

Last Answer : No-load test on a 3-phase induction motor was conducted at different supply voltage and a plot of input power versus voltage was drawn. This curve was extrapolated to intersect the y-axis. The intersection point yields Friction and windage loss

Description : The number of poles in a phase induction motor at 50 Hz and running at 1500 rpm will be?

Last Answer : The number of poles in a phase induction motor at 50 Hz and running at 1500 rpm will be 4.

Description : The stator of a 415V, 50 Hz, 4-pole slip ring Induction Motor is excited by rated frequency with slip rings open circuited. The rotor is made to rotate at a speed of 600 rpm in the opposite direction to the ... frequency of induced voltage across slip ring is A) 30 Hz B) 70 Hz C) 20 Hz D) 35 Hz

Last Answer : The stator of a 415V, 50 Hz, 4-pole slip ring Induction Motor is excited by rated frequency with slip rings open circuited. The rotor is made to rotate at a speed of 600 rpm in the opposite direction to the normal direction, The frequency of induced voltage across slip ring is 70 Hz

Description : The ratio of rotor output to rotor input in an induction motor is 0.96. The slip of the motor is (a) 0.04% (b) 4% (c) 6% (d) 12%

Last Answer : The ratio of rotor output to rotor input in an induction motor is 0.96. The slip of the motor is 4%

Description : A 400 V, 15 kW, 4-pole, 50 Hz, Y-connected induction motor has full load slip of 4%. The output torque of the machine at full load is  (A) 1.66 Nm (B) 95.50 Nm (C) 99.47 Nm (D) 624.73 Nm

Last Answer : A 400 V, 15 kW, 4-pole, 50 Hz, Y-connected induction motor has full load slip of 4%. The output torque of the machine at full load is 99.47 Nm

Description : The slip of an induction motor normally does not depend on  (A) rotor speed (B) synchronous speed (C) shaft torque (D) core-loss component

Last Answer : The slip of an induction motor normally does not depend on core-loss component

Description : What is the slip (as a percentage) when a 6 pole single phase induction motor operating on 220 V and 60 Hz is rotating at speed of 1140 rpm? A) 60% B) 5% C) 10% D) None of these

Last Answer : What is the slip (as a percentage) when a 6 pole single phase induction motor operating on 220 V and 60 Hz is rotating at speed of 1140 rpm? A) 60% B) 5% C) 10% D) None of these

Description : If the three-phase motor, shown in the illustrated schematic diagram, is running in the forward direction, which of the following actions must occur before the motor will reverse rotation? EL-0011 A. Normally-closed ... 'L1' and 'L3' must be interchanged via the 'R' contacts. D. All of the above.

Last Answer : Answer: C

Description : The speed of a 4-pole induction motor is controlled by varying the supply frequency while maintaining the ratio of supply voltage to supply frequency (V/f ) constant. At rated frequency of 50 Hz and rated voltage of 400 V ... load torque is constant  (A) 882 rpm (B) 864 rpm (C) 840 rpm (D) 828 rpm

Last Answer : The speed of a 4-pole induction motor is controlled by varying the supply frequency while maintaining the ratio of supply voltage to supply frequency (V/f ) constant. At rated frequency of 50 Hz and rated voltage of 400 ... torque is constant  (A) 882 rpm (B) 864 rpm (C) 840 rpm (D) 828 rpm

Description : When the supply voltage to an induction motor is reduced by 10%, the maximum torque will decrease by about  A) 5% B) 10% C) 20% D) 40%

Last Answer : When the supply voltage to an induction motor is reduced by 10%, the maximum torque will decrease by about 20%

Description : A 6-pole, 50Hz, 3-φ induction motor is running at 950 r.p.m. and has Cu loss of 5kW. The rotor input is (a) 10 kW (b) 95 kW (c) 100 kW (d) 9.5 kW 

Last Answer : s=(Ns-N)/Ns =(1000-950)/1000=0.05.rotor cu.loss= s*rotor inputwe have rotor cu loss=5kWtherefore, rotor input= rotor cu.loss/s                              =5kW/0.05                              =100 kW

Description : The stator mmf and rotor mmf of a 3-phase induction motor (A) are equal (B) rotate with slip speed (C) are opposite but rotate with synchronous speed (D) rotate with the same rotor speed 

Last Answer : a

Description : A 3-phase delta connected squirrel cage induction motor when started with a DOL starter has a starting torque of 600 NM. Its starting torque when star delta starter is used:

Last Answer : A 3-phase delta connected squirrel cage induction motor when started with a DOL starter has a starting torque of 600 NM. Its starting torque when star delta starter is used: 200 NM

Description : In a 3-phase voltage source inverter used for speed control of induction motor, anti-parallel diodes are used across each switching device. The main purpose of diodes is to:

Last Answer : In a 3-phase voltage source inverter used for speed control of induction motor, anti-parallel diodes are used across each switching device. The main purpose of diodes is to: Allow the motor to return energy during regeneration

Description : in a three-phase induction motor, the rotor field runs at the following speed with respect to the stator structure: 

Last Answer : in a three-phase induction motor, the rotor field runs at the following speed with respect to the stator structure: At synchronous speed in the direction of stator field

Description : A single-phase induction motor with only the main winding excited would exhibit the following response at synchronous speed  (A) Rotor current is zero (B) Rotor current is non-zero and is ... and backward rotating fields are equal (D) Forward rotating field is more than the backward rotating field

Last Answer : A single-phase induction motor with only the main winding excited would exhibit the following response at synchronous speed  (A) Rotor current is zero (B) Rotor current is non-zero and is ... backward rotating fields are equal (D) Forward rotating field is more than the backward rotating field

Description : A 3-phase induction motor is driving a constant torque load at rated voltage and frequency. If both voltage and frequency are halved, following statements relate to the new condition if stator resistance, leakage reactance and core loss are ... (A) All (B) 1, 2 and 3 (C) 2, 3 and 4 (D) 1 and 4

Last Answer : A 3-phase induction motor is driving a constant torque load at rated voltage and frequency. If both voltage and frequency are halved, following statements relate to the new condition if stator resistance, leakage reactance and core loss are ... A) All (B) 1, 2 and 3 (C) 2, 3 and 4 (D) 1 and 4

Description : The direction of rotation of a 3-phase induction motor is clockwise when it is supplied with 3-phase sinusoidal voltage having phase sequence A-B-C. For counter clockwise rotation of the motor, the phase sequence of the power supply should be  (A) B-C-A (B) C-A-B (C) A-C-B (D) B-C-A or C-A-B

Last Answer : The direction of rotation of a 3-phase induction motor is clockwise when it is supplied with 3-phase sinusoidal voltage having phase sequence A-B-C. For counter clockwise rotation of the motor, the phase sequence of the power supply should be  A-C-B 

Description : The type of single-phase induction motor having the highest power factor at full load is (A) shaded pole type (B) split-phase type (C) capacitor-start type (D) capacitor-run type

Last Answer : The type of single-phase induction motor having the highest power factor at full load is capacitor-run type

Description : In a single phase induction motor driving a fan load, the reason for having a high resistance rotor is to achieve (A) low starting torque (B) quick acceleration (C) high efficiency (D) reduced size

Last Answer : In a single phase induction motor driving a fan load, the reason for having a high resistance rotor is to achieve quick acceleration

Description : A three-phase cage induction motor is started by direct-on-line (DOL) switching at the rated voltage. If the starting current drawn is 6 times the full load current, and the full load slip is 4%, then ratio of the ... load torque is approximately equal to (A) 0.24 (B) 1.44 (C) 2.40 (D) 6.00

Last Answer : A three-phase cage induction motor is started by direct-on-line (DOL) switching at the rated voltage. If the starting current drawn is 6 times the full load current, and the full load slip is 4%, then ratio of the starting developed torque to the full load torque is approximately equal to 1.44

Description : A three-phase squirrel cage induction motor has a starting torque of 150% and a maximum torque of 300% with respect to rated torque at rated voltage and rated frequency. Neglect the stator resistance and rotational losses. The ... maximum torque is  (A) 13.48% (B) 16.42% (C) 18.92% (D) 26.79%

Last Answer : A three-phase squirrel cage induction motor has a starting torque of 150% and a maximum torque of 300% with respect to rated torque at rated voltage and rated frequency. Neglect the stator resistance and rotational losses. The value of slip for maximum torque is 26.79%

Description : A 4-pole induction motor, supplied by a slightly unbalanced three-phase 50 Hz source, is rotating at 1440 rpm. The electrical frequency in Hz of the induced negative sequence current in the rotor is  (A) 100 (B) 98 (C) 52 (D) 48

Last Answer : A 4-pole induction motor, supplied by a slightly unbalanced three-phase 50 Hz source, is rotating at 1440 rpm. The electrical frequency in Hz of the induced negative sequence current in the rotor is 98 

Description : For a single phase capacitor start induction motor, which of the following statements is valid?  A) The capacitor is used for power factor improvement B) The direction of rotation can be ... rotation cannot be changed D) The direction of rotation can be changed by interchanging the supply terminals

Last Answer : For a single phase capacitor start induction motor, which of the following statements is valid?  A) The capacitor is used for power factor improvement B) The direction of rotation can be ... cannot be changed D) The direction of rotation can be changed by interchanging the supply terminals

Description : Consider the following statements: Star delta starter is used in 3-phase induction motor because it  1. Prevents heating of the motor winding  2. Ensures permissible minimum starting current  3. Is regulated by electricity ... and 4 are correct (c) 1, 3 and 4 are correct (d) 1 and 2 are correct 

Last Answer : Consider the following statements: Star delta starter is used in 3-phase induction motor because it  1. Prevents heating of the motor winding  2. Ensures permissible minimum starting current  3. Is regulated by ... and 4 are correct (c) 1, 3 and 4 are correct (d) 1 and 2 are correct 

Last Answer : Single phase induction motor usually operates on 0.6 power factor lagging.

Last Answer : A single-phase induction motor is inherently non-self-starting with low torque.

Last Answer : The power factor of a single-phase induction motor is usually lagging.

Description : What is the rotor speed of a four pole, 60 cycle, induction motor operating at full load with 3% slip? A. 270 RPM B. 540 RPM C. 873 RPM D. 1746 RPM

Last Answer : Answer: D

Description : What is the slip of an induction motor during normal running?

Last Answer : More than zero.

Description : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be?

Last Answer : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be at the slot edge where coil enters or comes out of the slot.

Last Answer : In a capacitor start motor, the phase displacement between starting and running winding can be nearly 90°.

Last Answer : In a split phase motor, the running winding should have low resistance and high inductance.

Description : To reverse the direction of rotation of a three-phase AC induction motor, do one of the following: w) reverse any two of the three-phase connections x) change the frequency of the applied AC power y) operate the motor below the stall torque at very high slip z) none of the above

Last Answer : ANSWER: W -- REVERSE ANY TWO OF THE THREE-PHASE CONNECTIONS 

Description : A 3 phase 50 Hz induction motor has full load speed of 970 rpm. Calculate no of poles and slip frequency.

Last Answer : The number of poles in an induction motor can be calculated using the following formula: No. of poles = (120 * frequency) / speed In this case, the number of poles would be calculated as follows: No. of poles = ( ... ) - 50 Hz = 8.08 Hz So the motor has 6 poles and a slip frequency of 8.08 Hz.

Description : A four pole, 60 Hz, three-phase synchronous motor comes up to 1760 RPM when started as an induction motor. What is the percent slip after the rotor field is energized? A. 0 B. 1.1 C. 2.2 D. 3.3

Last Answer : Answer: A

Description : The torque and current curves for a three-phase induction motor with a cage rotor, are shown in the illustration. Which of the following statements is true concerning the depicted curves? EL-0056 A. As slip ... D. If the motor is loaded to the point where 40% slip has resulted, it will stall.

Last Answer : Answer: D

Description : A three-phase, squirrel cage, induction motor will run hot due to _____________. A. open stator coils B. high power factor C. dirty or corroded slip rings D. reversed commutating poles

Last Answer : Answer: A

Description : A 400kW, 3-phase, 440V, 50Hz induction motor has a speed of 950 r.p.m. on fullload. The machine has 6 poles. The slip of the machine will be _______________. (A) 0.06 (B) 0.10 (C) 0.04 (D) 0.05

Last Answer : Ans: D N = Ns (1-S) 950 = 120 x 50 (1-S)/6 S = 0.05

Description : The rotor power output of a 3-phase induction motor is 15 KW and corresponding slip is 4%. The rotor copper loss will be (A) 600 W. (B) 625 W (C) 650 W (D) 700 W

Last Answer : Ans: B Rotor copper losses = rotor input- rotor output and output = (1-s) input ∴ Input = output/(1-s) = 15000 /1-0.04 = 15625 ∴ loss = 15625 -1500 = 625 watt

Description : A 3-phase, 400 votts, 50 Hz, 100 KW, 4 pole squirrel cage induction motor with a rated slip of 2% will have a rotor speed of (A) 1500 rpm (B) 1470 rpm (C) 1530 rpm (D) 1570 rpm

Last Answer : Ans: B N = NS (1-S) and NS =120 f / p =120 x 50 /4 = 1500 rpm ∴N= 1500 (1-0.02) =1470 rpm