Description : instrument is used to monitor O2, CO in flue gas (EA) a) Combustion analyzer b) Power analyzer c) Pyrometer d) Fyrite
Last Answer : Combustion analyzer
Description : Which instrument is used to monitor O2, CO in flue gas? c)Combustion analyzer c) Pyrometer d)Power analyzer d) Fyrite
Description : Which instrument is used to monitor O2, CO in flue gas? (EA) a) Combustion analyser b) Power analyser c) Pyrometer d) Fyrite
Last Answer : Combustion analyser
Description : measures oxygen and temperature of the flue gas. a) Fuel efficiency monitor. b) Combustion analyzer. c) Contact thermometer. d) Infrared thermometer.
Description : When incomplete combustion loss is high, the flue gas analysis shows large amount of (A) CO2 (B) CO (C) O2 (D) C
Last Answer : (B) CO
Description : Volumetric composition of flue gas analysed with the Orsat apparatus is : CO2 = 12%, O2 = 8%, CO = nil, N2 = 80%. This flue gas composition indicates that (A) Pure oxygen has been used for combustion ... very high (C) Excess air has been used for combustion (D) Hydrogen is not present in the fuel
Last Answer : (C) Excess air has been used for combustion
Description : To maximize the combustion efficiency, which of the following in the flue gas needs to be done? a) maximize O2 b) maximize CO2 c) minimize CO2 d) maximize CO
Last Answer : b) maximize CO2
Description : Answer the following S. No Statement Chose the correct answer OR Fill-in-the-blanks 1 Fyrite measures CO2, O2 and SO2 True/False 2 Ultrasonic Flow Meter uses the principle of____& ____ Fill in the ... of RPM meter is used and for a visible shaft-end _______ type of RPM meter is used.
Last Answer : Sr No Statement Chose the correct answer OR Fill-in-the-blanks Solution 1 Fyrite measures CO2, O2 and SO2 True/False False 2 Ultrasonic Flow Meter uses the principle of____& ____ ... ] 10 In a gasification system the reduction zone is above the combustion zone True/False False
Description : Incomplete combustion of fuel in the furnace is judged by high __________ of the flue gases. (A) CO content (B) Dew point (C) CO2 content (D) O2 content
Last Answer : (A) CO content
Description : Efficiency of the combustion of a fuel is judged by the __________ the flue gas. (A) % of CO2 in (B) % of O2 in (C) Temperature of (D) Colour of
Last Answer : (B) % of O2 in
Description : In order to maintain a reducing atmosphere in a furnace, it should have (A) No O2 in flue gas (B) CO in flue gas (C) High excess air (D) None of these
Last Answer : (B) CO in flue gas
Description : The sequence of absorption in flue gas analysis by Orsat's apparatus is respectively (A) CO2 , O2 , CO (B) CO, O2 , CO2 (C) CO2 , CO, O2
Last Answer : (A) CO2 , O2 , CO
Description : are portable devices capable of estimating the combusting efficiency of furnaces, boilers, or other fossil fuel burning machines. a) Sound analyzer. c) Combustion analyzer. b) Light analyzer. d)Temperature analyzer
Last Answer : Combustion analyzer.
Description : are portable devices capable of estimating the combusting efficiency of furnaces, boilers, or other fossil fuel burning machines. a) Sound analyzer. b) Light analyzer. c) Combustion analyzer. d) Temperature analyzer.
Description : Economizer is provided to utilize the flue gas heat for ___ a) preheating the boiler feed water b) preheating the stock c) preheating the combustion air d) preheating fuel
Last Answer : preheating the boiler feed water
Description : Flue gas obtained on complete combustion of pure acetylene (a hydrocarbon fuel) will contain (A) CO (B) CO2 (C) H2O (D) Both (B) & (C)
Last Answer : (D) Both (B) & (C)
Description : CO2 measurement of Fyrite kit is based on (EA c) Weight basis (dry) c) Weight basis (wet) d) Volume basis (dry) d) Volume basis (wet)
Last Answer : volume basis
Description : The main drawback of supplying more excess air in the combustion of fuel is the (A) Excessive power requirement of air blower (B) Enhanced sensible heat loss in the flue gas (C) Intermittent and uncontrolled combustion of the fuel (D) High exit flue gas temperature from the furnace
Last Answer : (B) Enhanced sensible heat loss in the flue gas
Description : The average molecular weight of a flue gas having the composition by volume as CO2 = 25%, O2 = 25%, N2 = 50% will be (A) 27.6 (B) 23 (C) 47.3 (D) 42.9
Last Answer : (B) 23
Description : Water gas is a mixture of (A) CO2 and O2 (B) O2 and H2 (C) H2, N2 and O2 (D) CO, N2 and H2.
Last Answer : CO, N2 and H2.
Description : The instrument used to regulate temperature to a particular degree is called : (1) Thermostat (2) Thermometer (3) Pyrometer (4) Thermocouple
Last Answer : (1) Thermostat Explanation: A thermostat is a component which senses the temperature of a system so that the system's temperature is maintained near a desired set point. At its core, a thermostat is simply the controls used to regulate temperature in a heating system.
Description : The instrument which measures very high temperature is------? A. Manometer B. Thermostat C. Chronometer D. Pyrometer (Answer) E. None of these
Last Answer : D. Pyrometer (Answer)
Description : An electro pyrometer is an instrument used to measure?
Last Answer : high temperatures
Description : Oxygen enrichment of combustion air does not result in increase of the (A) Flame temperature (B) Oxygen in the flue gas (C) Stack loss (D) Heat transfer rate in the furnace
Last Answer : (B) Oxygen in the flue gas
Description : Ostwald charts are meant for (A) Computing the excess/deficiency of combustion air (B) Calculation of flue gas temperature (C) Computation of flue gas analysis (D) None of these
Last Answer : (A) Computing the excess/deficiency of combustion air
Description : Out of the following fuels used in a furnace exhausting flue gas at a temperature of 600°C, the percentage stack loss will be maximum in case ofcomplete combustion of (A) Furnace oil with air (B) Furnace oil with oxygen (C) Blast furnace gas with air (D) Blast furnace gas with oxygen
Last Answer : (C) Blast furnace gas with air
Description : In practical operation of any furnace, zero oxygen percentage or theoretical CO2 percentage in flue gas is rarely achieved, because of (A) Use of non-preheated combustion air (B) Use of pulverised solid ... of fuel & air and infiltration of air (D) Use of excessive positive draft in the furnace
Last Answer : (C) Imperfect mixing of fuel & air and infiltration of air
Description : To reduce the stack loss, heat recovery from flue gas can be done by (A) Preheating of cold stock (B) Preheating of combustion air (C) Steam generation in waste heat boilers (D) All (A), (B) and (C)
Last Answer : (D) All (A), (B) and (C)
Description : Acid dew point temperature (ADT) of a flue gas produced by the combustion of a fuel containing 1% sulphur may be about __________ °C. (A) 80 (B) 130 (C) 180 (D) 250
Last Answer : (B) 130
Description : Combustion of fuel in a furnace with oxygen enriched air results in higher (A) Flue gas volume (B) Flame temperature (C) Fuel consumption (D) Stack loss
Last Answer : (B) Flame temperature
Description : Orsat apparatus is meant for (A) Gravimetric analysis of flue gas (B) Finding out combustion efficiency (C) Direct determination of nitrogen in flue gas by absorbing it in ammoniacal cuprous chloride (D) None of these
Last Answer : (D) None of these
Description : Pick out the wrong statement. (A) High concentration of oxygen in flue gas means high stack loss (B) Gaseous fuels require the least % excess air for complete combustion (C) The ratio of fixed carbon to ... coal is called its 'fuel ratio' (D) Calorific value of natural gas is more than that of LPG
Last Answer : (D) Calorific value of natural gas is more than that of LPG
Description : Higher efficiency in the combustion of solid fuel cannot be achieved by (A) Proper fuel preparation (B) Keeping the flue gas exhaust temperature very high (C) Adopting efficient-fuel firing technique & equipment (D) Supplying correct quantity of combustion air
Last Answer : (B) Keeping the flue gas exhaust temperature very high
Description : If oxygen content in the flue gas rises too high, fuel is being wasted by (A) Incomplete combustion (B) Dry gas/stack gas loss (C) Moisture loss (D) None of these
Last Answer : (B) Dry gas/stack gas loss
Description : During combustion of a gaseous fuel, the presence of a non-luminous flame is an indication of the (A) Incomplete combustion (B) Complete combustion (C) High oxygen in flue gas (D) None of these
Last Answer : (B) Complete combustion
Description : Presence of nitrogen in combustion air does not reduce the (A) Amount of heat liberated (B) Flame temperature (C) Flue gas temperature (D) Any of the above
Last Answer : (A) Amount of heat liberated
Description : A carbonaceous fuel (containing no H2 or hydrocarbons) is burnt and the resulting flue gas contains 21% CO2 . It means that (A) 21% excess air has been used for combustion (B) 21% excess oxygen has ... (C) Complete combustion of fuel has taken place (D) No excess air has been used for combustion
Last Answer : (C) Complete combustion of fuel has taken place
Description : Too much of excess air in combustion results in high (A) Fuel consumption for the same heat load (B) Stack gas temperature (C) Percentage of oxygen in flue gases (D) All (A), (B) and (C)
Description : Advantages of fluidised bed combustion are (A) Reduced NOx formation in flue gas (B) Lower furnace operating temperature (C) High heat transfer rate (D) All (A), (B) & (C)
Last Answer : (D) All (A), (B) & (C)
Description : Incomplete combustion of a fuel is characterised by the high __________ in the flue gas. (A) Smoke (B) Temperature (C) Oxygen (D) Carbon monoxide
Last Answer : (D) Carbon monoxide
Description : Oxygen content in a flue gas was found to be 4%. It implies that excess air used for combustion was around __________ percent. (A) 4 (B) 96 (C) 20 (D) 40
Last Answer : (C) 20
Description : Pick out the wrong statement. (A) A slight haze at the top of chimney indicates good combustion in the furnace (B) A bag filter incurs very small pressure drop and is very efficient for ... dust collection equipment for removal of submicronic dust particles present in flue gas (D) None of these
Last Answer : (B) A bag filter incurs very small pressure drop and is very efficient for removal of submicronic dust particles from flue gases at very high temperature
Description : Oxygen trim control strategy __ a. continuously measures the oxygen content in the flue gas b. adjusts the combustion air flow c. Continually tuning the air-fuel mixture. d. All of above
Last Answer : d. All of above
Description : Which among the following has the highest flue gas loss on combustion due to Hydrogen in the fuel? a) natural gas b) furnace oil c) coal d) light diesel oil
Last Answer : a) natural gas
Description : Name THREE TECHNIQUES for removing particulates from flue gas produced from the combustion of coal?
Last Answer : (1) ELECTROSTATIC PRECIPITATION (ESP) (2) FABRIC FILTER OR BAGHOUSE (3) WET SCRUBBERS (4) MECHANICAL COLLECTORS OR CYCLONES
Description : Ringelmann chart is used for the measurement of the (A) Combustibles present in automobile exhaust (B) Smoke density from a chimney (C) Exhaust gas density (D) Flue gas temperature
Last Answer : (B) Smoke density from a chimney
Description : Infrared thermometer is used to measure a) Surface temperature b) Flame temperature c) Flue gas temperature d) Hot water temperature
Last Answer : Surface temperature
Description : Calculate the recoverable waste heat (Q, in kCal/hour) from flue gases using the followingparameters: V (flow rate of the substance) 2000 m3/hr r (density of the flue gas): 0.9 kg/m3 Cp (specific heat ... (temperature difference): 120 oC h (recovery factor): 50% a. 21600 b. 43200 c. 25600 d. 34000
Last Answer : 21600
Description : Heat recovery equipment will be most effective when the temperature of flue gas is: a) 250oC b) 200 oC c)400 oC d) 280 oC
Last Answer : 400 oC