The active power of a synchronous generator can be varied mainly by (a) changing field excitation (b) changing of prime mover speed (c) both (a) and (b) (d) none of the above

1 Answer

Answer :

C

Related questions

Description : A synchronous generator is feeding a zero power factor (lagging) load at rated current. The armature reaction is  (A) magnetizing (B) demagnetizing (C) cross-magnetizing (D) ineffective

Last Answer : A synchronous generator is feeding a zero power factor (lagging) load at rated current. The armature reaction is demagnetizing 

Description : A 100 MVA, 11 KV, 3-phase, 50 Hz, 8—pole synchronous generator has an inertia constant H equal to 4 seconds. The stored energy in the rotor of the generator at synchronous speed will be  A) 100 MJ B) 400 MJ C) 800 MJ D) 12.5 MJ

Last Answer : 800

Description : A stand alone engine driven synchronous generator is feeding a partly inductive load. A capacitor is now connected across the load to completely nullify the inductive current. For this operating condition.  ... left unaltered (D) the field current has to be reduced and fuel input left unaltered

Last Answer : A stand alone engine driven synchronous generator is feeding a partly inductive load. A capacitor is now connected across the load to completely nullify the inductive current. For this operating condition.  the field current has to be reduced and fuel input left unaltered

Description : A 500 MW, 3-phase, Y-connected synchronous generator has a rated voltage of 21.5 kV at 0.85 p.f. The line current when operating at full load rated conditions will be  (A) 13.43 kA (B) 15.79 kA (C) 23.25 kA (D) 27.36 kA

Last Answer : A 500 MW, 3-phase, Y-connected synchronous generator has a rated voltage of 21.5 kV at 0.85 p.f. The line current when operating at full load rated conditions will be 15.79 kA

Description : The angle δ in the swing equation of a synchronous generator is the  (A) angle between stator voltage and current (B) angular displacement of the rotor with respect to the stator (C) angular ... (D) angular displacement of an axis fixed to the rotor with respect to a synchronously rotating axis

Last Answer : The angle δ in the swing equation of a synchronous generator is the angular displacement of an axis fixed to the rotor with respect to a synchronously rotating axis

Description : For a fault at the terminals of a synchronous generator, the fault current is maximum for a  A) 3-phase fault B) 3-phase to ground fault C) Line to ground fault D) Line to line fault

Last Answer : C) Line to ground fault

Description : A 500 MVA, 11 KV synchronous generator has 0.2 p.u. synchronous reactance. The p.u. synchronous reactance on the base values of 100 MVA and 22 KV is  A) 0.16 B) 0.01 C) 4.0 D) 0.25

Last Answer : A 500 MVA, 11 KV synchronous generator has 0.2 p.u. synchronous reactance. The p.u. synchronous reactance on the base values of 100 MVA and 22 KV is 0.01

Description : A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because?

Last Answer : A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because stator supply is not required to produce magnetic field.

Last Answer : The standard full-load power factor ratings for synchronous motors are unity or 0.8 leading.

Last Answer : Synchronsizing power of a synchronous machine is inversely proportional to the synchronous reactance.

Last Answer : For power factor correction, synchronous motors operate at no-load and greatly over-excited fields.

Description : If we change the excitation of synchronous machine will it affect on power factor?

Last Answer : Yes, If we change the excitation of synchronous machine it will affect on power factor. If the synchronous motor is overexcited then it will have leading power factor and if the motor is underexcited then it will have lagging power factor.

Description : If the load of the normally excited synchronous motor is increased the power factor will?

Last Answer : If the load of the normally excited synchronous motor is increased the power factor will become lagging.

Description : The synchronous motor which works on leading power factor and does not drive any mechanical load is called?

Last Answer : The synchronous motor which works on leading power factor and does not drive any mechanical load is called synchronous condenser.

Description : If the field of synchronous motor is under excited, power factor will be?

Last Answer : If the field of synchronous motor is under excited, power factor will be lagging.

Description : The synchronous motor will develop maximum power when the load angle is?

Last Answer : The synchronous motor will develop maximum power when the load angle is 900.

Description : The speed of a synchronous motor is varied by _____________. A. interchanging any two of the three live leads B. changing the voltage of the system C. changing the input frequency D. increasing the field excitation

Last Answer : Answer: C

Description : The speed of a wound-rotor induction motor _____________. A. will be fixed by the number of field poles B. can be varied by a rheostat-type control C. can only be synchronous speed at full load D. can only attain synchronous speed at no load

Last Answer : Answer: B

Description : How the power of the Generator can be varied?  

Last Answer : Injecting inlet steam to the prime mover can vary active power. Reactive power can vary by the Generator main field voltage variation. An excitation change PF at which load is delivered ... core of transformers, motors, generators, overhead transmission lines (capacitive), household appliances etc. 

Description : The number of electrical degrees ‘passed through’ in one revolution of a 6-pole synchronous alternator is: A) 360 degree B) 720 degree C) 1080 degree D) 2160 degree

Last Answer : 1080

Description : A cylindrical rotor synchronous motor is switched on to the supply with its field windings shorted on themselves, the motor will .  A) Not start B) Start but will not run at synchronous speed C) Start as an induction motor and then run as a synchronous motor D) Start and run as a synchronous motor

Last Answer : A cylindrical rotor synchronous motor is switched on to the supply with its field windings shorted on themselves, the motor will Start but will not run at synchronous speed

Description : In relation to the synchronous machines, which on of the following statements is false ?  (A) In salient pole machines, the direct-axis synchronous reactance is greater than the quadrature- ... motor represents the variation in the armature current with field excitation, at a given output power.

Last Answer : In relation to the synchronous machines, which on of the following statements is false ?  (A) In salient pole machines, the direct-axis synchronous reactance is greater than the quadrature- ... motor represents the variation in the armature current with field excitation, at a given output power.

Description : A 100 kVA, 415 V(line), star-connected synchronous machine generates rated open circuit voltage of 415 V at a field current of 15 A. The short circuit armature current at a field current of 10 A is equal to the ... unit saturated synchronous reactance is  (A) 1.731 (B) 1.5 (C) 0.666 (D) 0.577

Last Answer : 0.6

Description : A three phase, salient pole synchronous motor is connected to an infinite bus. It is operated at no load a normal excitation. The field excitation of the motor is first reduced to zero ... First increases and then decreases steeply (C) First decreases and then increases steeply (D) Remains constant

Last Answer : B

Description : During hunting of synchronous motor  A) Negative phase sequence currents are generated B) Harmonics are developed in the armature current C) Damper bars develop torque D) Field excitation increases 

Last Answer : During hunting of synchronous motor Damper bars develop torque

Last Answer : Slip-rings in a synchronous motor carry direct current.

Last Answer : The efficiency of a properly designed synchronous motor will usually fall in range 85 to 95%.

Last Answer : A synchronous motor running with normal excitation adjusts to load increases essentially by increase in armature current.

Last Answer : The operating speed of a synchronous motor can be changed to new fixed value by changing frequency.

Last Answer : A synchronous motor can develop synchronous torque at synchronous speed.

Last Answer : In case one phase of a three-phase synchronous motor is short-circuited the motor will not start.

Last Answer : Synchronous motors are generally not self-starting because the direction of instantaneous torque reverses after half cycle.

Last Answer : In a synchronous motor, the armature current has large values for high and low excitation.

Last Answer :  The size of a synchronous motor decreases with the increase in flux density.

Last Answer : The duration of sudden short-circuit test on a synchronous motor is usually about one second.

Description : The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as?

Last Answer : The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as pull-in torque.

Last Answer : A synchronous machine with low value of short-circuit ratio has lower stability limit.

Last Answer : The construction of a synchronous motor resembles an alternator.

Last Answer : If the field winding of an unloaded salient pole synchronous motor is open circuited, the motor will stop.

Last Answer : Exciters of synchronous machines are d.c. shunt machines.

Last Answer : The coupling angle or load angle of synchronous motor is defined as the angle between the rotor and the stator poles of opposite polarity.

Last Answer : If the synchronous motor, properly synchronised to the supply is running on no load and is having negligible loss then the stator current will be zero.

Last Answer : The armature current of the synchronous motor has large values for low and high excitation.

Description : Which motor have more efficiency, synchronous motor or induction motor?

Last Answer : Synchronous motor has more efficiency.

Description : If we change the excitation of synchronous machine will it affect on motor speed?

Last Answer : No, If we change the excitation of synchronous machine it will not affect on motor speed.

Description : How can we reverse the direction of rotation of synchronous motor?

Last Answer : By reversing supply phase sequence we can reverse the direction of rotation of synchronous motor.

Description : What is the maximum value of torque angle in synchronous motor?

Last Answer : The maximum value of torque angle in synchronous motor is 90 degrees electrical.

Description : V - curve of synchronous machine shows the relation between?

Last Answer : V - curve of synchronous machine shows the relation between AC armature current and DC field current.

Description : Why synchronous machine is called doubly excited machine?

Last Answer : Armature windings of synchronous machines either deliver 3 phase AC or absorb 3 phase AC source,  whereas field windings are energized from DC source. Thus due to presence of AC on armature and DC on field windings, synchronous machines are often referred as doubly excited machines.

Description : Hunting in synchronous motor cannot be due to?

Last Answer : Hunting in synchronous motor cannot be due to windage friction.