Which alternator will have more number of poles ? (a) coupled to steam turbine (b) coupled to gas turbine (c) coupled to hydraulic turbine (d) None of the above 

2 Answers

Answer :

A

Answer :

b

Related questions

Description : State working principle of alternator. State the meaning self and separate excitation. 

Last Answer : Working principle of alternator: When a conductor is moved in magnetic field or a magnetic field moved with respect to conductor, according to Faraday's law of electromagnetic induction, the conductor ... like battery or shaft-mounted exciter, then the excitation is said to be separate excitation.

Description : Explain the construction of alternator with neat diagram.

Last Answer : Diagram: Construction of three phase alternator: Construction wise, an alternator generally consists of field poles placed on the rotating fixture of the machine i.e. rotor as shown in the ... of rotor used in construction of alternator, 1. Salient pole type. 2. Cylindrical rotor type. 

Description :  An 8-pole alternator runs at 750 rpm and supplies power to a 6-pole induction motor which has a full load slip of 3 percent. The full load speed of the induction motor will be: A) 1000 rpm B) 920 rpm C) 950 rpm D) 970 rpm

Last Answer : An 8-pole alternator runs at 750 rpm and supplies power to a 6-pole induction motor which has a full load slip of 3 percent. The full load speed of the induction motor will be: 970 rpm

Description :  In an alternator if the winding is short pitched by 60 electrical degrees, its pitch factor will be: A) 1.0 B) 0.866 C) 0.75 D) 0.50

Last Answer :  In an alternator if the winding is short pitched by 60 electrical degrees, its pitch factor will be: A) 1.0 B) 0.866 C) 0.75 D) 0.50

Description :  The driving power from the prime-mover driving the alternator is lost but the alternator remains connected to the supply network; the field supply also remains on. The alternator will: A) ... as a synchronous motor but will rotate in a reverse direction to that corresponding to generator action 

Last Answer : The driving power from the prime-mover driving the alternator is lost but the alternator remains connected to the supply network; the field supply also remains on. The alternator will: behave as a synchronous motor and will rotate in the same direction

Description : If the excitation of an alternator operating in parallel with other alternators decreased, its: (1) Power factor becomes more leading (2) Output Kw will change (3) Power factor becomes more lagging (4) Power factor becomes unity

Last Answer : If the excitation of an alternator operating in parallel with other alternators decreased, its: Power factor becomes more leading

Description : Drop in alternator frequency is corrected by: (1) Damper winding (2) Increased prime mover output (3) Automatic voltage regulator (4) None of these

Last Answer : Drop in alternator frequency is corrected by: Increased prime mover output

Description : A field excitation of 20 A in a certain alternator results in an armature current of 400 A in short circuit and a terminal voltage of 2000 V on open circuit. The magnitude of the internal voltage drop within the machine at a load current of 200 A is  (A) 1 V (B) 10 V (C) 100 V (D) 1000 V

Last Answer : 800

Description : A 8 pole alternator rotates at 750 r.p.m. Its frequency is

Last Answer : A 8 pole alternator rotates at 750 r.p.m. Its frequency is 50 Hz

Description : A 60 Hz, 2 pole alternator should run at • a. 3000 r.p.m. c. 1500 r.p.m. • b. 3600 r.p.m. d. 1800 r.p.m.

Last Answer : A 60 Hz, 2 pole alternator should run at 3600 r.p.m.

Description : Is the speed of alternator is directly proportional to frequency?

Last Answer : Yes, speed of alternator is directly proportional to frequency.

Description : At which power factor alternator is said to be overexcited?

Last Answer : At leading power factor alternator is said to be overexcited.

Description : The power factor of an alternator depends on?

Last Answer : The power factor of an alternator depends on load.

Description : In an alternator at lagging power factor the generated voltage per phase as compared to that at unity power factor?

Last Answer : In an alternator, at lagging power factor the generated voltage per phase as compared to that at unity power factor must be more than terminal voltage.

Description : The magnitude of various voltage drops that occur in an alternator depends on?

Last Answer : The magnitude of various voltage drops that occur in an alternator depends on load current.

Description : In alternator where the voltage drop occurs?

Last Answer : In alternator voltage drop occurs in armature resistance, leakage reactance, and armature reactance.

Description : Which of the following statements is true concerning the operation of two alternators in parallel? A. The cycles per second of each alternator are the same. B. Both alternator governors must be set ... be the same on each alternator. D. The load must always be divided equally between alternators.

Last Answer : Answer: A

Description : The standard method of controlling the output voltage of a 440 volt, 60 Hz, AC generator is accomplished by adjusting the ____________. A. prime mover speed droop B. number of poles C. alternator field excitation D. load on the alternator

Last Answer : Answer: C

Description : The frequency of an alternator at a given RPM is determined by the _____________. A. number of turns of wire in the armature coil B. number of magnetic poles C. strength of the magnets used D. output voltage

Last Answer : Answer: B

Description : The division of kilowatt load between two paralleled alternators is determined by the _____________. A. amount of field excitation to the leading machine B. load-speed characteristics of the governors C. amount of field excitation to the lagging machine D. number of field poles per alternator

Last Answer : Answer: B

Description : The frequency output of an operating alternator is controlled by the _____________. A. relative speed of the rotor poles B. number of turns of wire in the armature coil C. strength of the magnets used D. output voltage

Last Answer : Answer: A

Description : One factor that determines the frequency of an alternator is the ____________. A. number of turns of wire in the armature coil B. number of magnetic poles C. strength of the magnets used D. output voltage

Last Answer : Answer: B

Description : The output voltage of a 440 volt, 60 hertz, AC generator is controlled by the _____________. A. prime mover speed B. exciter output voltage C. load on the alternator D. number of poles

Last Answer : Answer: B

Description : What is the frequency of the output voltage of an alternator with four poles that is rotated at 3600 rpm?

Last Answer : 120 Hz.

Description : What is the frequency of an alternator which has 2 poles and makes 3600 revolutions per minute? A) 3600 HZ B) 60 Hz C) 120 Hz D) None of these

Last Answer : What is the frequency of an alternator which has 2 poles and makes 3600 revolutions per minute? A) 3600 HZ B) 60 Hz C) 120 Hz D) None of these

Description : Two 3-phase, Y-connected alternators are to be paralleled to a set of common busbars. The armature has a per phase synchronous reactance of 1.7 Ohm and negligible armature resistance. The line voltage of the first machine is adjusted to ... will be  (A) 16.98 A (B) 29.41 A (C) 33.96 A (D) 58.82 A

Last Answer : Two 3-phase, Y-connected alternators are to be paralleled to a set of common busbars. The armature has a per phase synchronous reactance of 1.7 Ohm and negligible armature resistance. The ... instant they are paralleled. Under this condition, the synchronizing current per phase will be 16.98 A

Description : Salient pole rotor is use for which speed?

Last Answer : Salient pole rotor is use for low and medium speed prime movers.

Description : Which rotor is use for high speed in turbo alternators?

Last Answer : Non-salient pole rotor is used for high speed in turbo alternators.

Description : The number of electrical degrees ‘passed through’ in one revolution of a 6-pole synchronous alternator is: A) 360 degree B) 720 degree C) 1080 degree D) 2160 degree

Last Answer : 1080

Description : If a bar magnet is cut length wise into 3 parts, what will the total number of poles be? -General Knowledge

Last Answer : The answer is '6'

Description : If a bar magnet is cut length wise into 3 parts, what will the total number of poles be? -General Knowledge

Last Answer : answer:

Description : If a bar magnet is cut length wise into 3 parts, what will the total number of poles be? -General Knowledge

Last Answer : answer:

Description : True or False The strength of the magnetic poles in an electromagnet decreases with an increase in the number of turns of wire and the current flowing through them.?

Last Answer : FALSE

Description : The most practical method of controlling the RPM of a step-speed AC motor is to _____________. A. change input voltage B. vary the number of poles C. vary power factor D. change the number of brushes

Last Answer : Answer: B

Description : The speed of a squirrel-cage, multi-speed, induction motor, as used aboard ship, is varied by changing the __________. A. number of connected poles in the stator B. frequency to the motor C. excitation voltage D. resistance of the rotor circuit

Last Answer : Answer: A

Description : If a three-phase induction motor is operated under a light load and it develops an open in one of its supply lines, the motor will _____________. A. continue to run, but will vibrate and have reduced ... speed up due to the reduced number of poles C. run cooler due to reduced current flow D. stop

Last Answer : Answer: A

Description : The propeller shaft speed in a turbo-electric, synchronous, propulsion drive motor is changed by varying the __________. A. turbine speed B. number of motor poles C. field strength of the generator D. field strength of the motor

Last Answer : Answer: A

Description : The amount of voltage induced in the windings of an AC generator depends mainly on _____________. A. the number of field poles energized B. the speed at which the stator windings rotate through the magnetic field C. the strength of the magnetic field D. all of the above

Last Answer : Answer: C

Description : To increase the frequency of an operating AC generator, you should ____________. A. increase the field excitation B. decrease the field excitation C. increase the number of magnetic poles D. increase the speed of the prime mover

Last Answer : Answer: D

Description : The speed of a squirrel-cage motor is usually changed by _____________. A. varying the frequency to the machine B. adding resistance in series with the stator windings C. adding resistance in parallel with the stator windings D. changing the number of connected poles in the stator

Last Answer : Answer: D

Description : An AC circuit has capacitance arranged in series. If the line voltage remains constant, the capacitive reactance value can be varied by changing the _____________. A. line frequency B. resistance C. number of commutating poles D. number of interpoles

Last Answer : Answer: A

Description : The speed of a squirrel-cage induction motor is determined by the ____________. A. diameter of the stator B. number of stator poles C. rotor winding resistance D. rotor conducting bars resistance

Last Answer : Answer: B

Description : Under normal conditions, the speed of a two-speed squirrel cage induction motor is changed by varying the ____________. A. frequency of the applied voltage B. resistance in the rotor circuit C. number of field poles D. amplitude of the applied voltage

Last Answer : Answer: C

Description : The speed of a wound-rotor induction motor _____________. A. will be fixed by the number of field poles B. can be varied by a rheostat-type control C. can only be synchronous speed at full load D. can only attain synchronous speed at no load

Last Answer : Answer: B

Description : The direction of rotation of an induction motor is ________. A. opposite the rotating field direction B. the same as the direction of the rotating field C. determined by the number of poles D. determined by the staggering of the brushes

Last Answer : Answer: B

Description : The speed of a three-phase squirrel-cage induction-type motor operating in a fixed frequency system is varied by changing the _____________. A. number of phases to the motor B. number of stator poles C. locked rotor current D. resistance of the rotor winding

Last Answer : Answer: B

Description : The speed of a squirrel cage induction motor is determined by the _____________. A. diameter of the stator B. number of stator poles C. rotor winding resistance D. bar resistance of the conducting rotor

Last Answer : Answer: B

Description : In an AC synchronous motor electric propulsion plant, propeller speed is controlled by varying the _____________. A. prime mover speed B. electric coupling field strength C. number of energized main motor poles D. propulsion generator field strength

Last Answer : Answer: A

Description : If a bar magnet is cut length wise into 3 parts, what will the total number of poles be?

Last Answer : 6

Description : What determines the number of field poles required to establish a rotating magnetic field in a multiphase motor stator?

Last Answer : The number of phases in the applied voltage.