1 Answer

Answer :

High Voltage side is open circuited.

Related questions

Last Answer : Primary side is low voltage side and secondary side is high voltage side.

Description : During open circuit test of a transformer?

Last Answer : During open circuit test of a transformer primary is supplied rated voltage.

Last Answer : In short circuit test of transformer the low voltage side is short circuited . On high voltage side the voltmeter is connected in parallel and ammeter in series and also a wattmeter is ... circuit test is done for determining impedance and losses. In this test iron losses is neglected.

Description : A d.c. source has an open circuit voltage of 30 V and an internal resistance of 1.5 Ohm. A resistive load is connected to the source. Maximum power dissipated in the load is (A) 300 W (B) 150 W (C) 45 W (D) 20 W

Last Answer : A d.c. source has an open circuit voltage of 30 V and an internal resistance of 1.5 Ohm. A resistive load is connected to the source. Maximum power dissipated in the load is 150 W

Description : Describe the difference between an open circuit and a short circuit.

Last Answer : Open circuit means the wire is cut meaning power will not flow and close circuit means wire is not cut and hence power will flow.Short circuit is the same as close circuit

Last Answer : It is required to measure the true open circuit e.m.f. of a battery. The best device is D.C. potentiometer.

Description : Explain open emitter BJT drive circuit.

Last Answer : open emitter BJT drive circuit:

Description : An open-circuit test on a transformer is conducted primarily to measure?

Last Answer : The open-circuit test in a transformer is used to measure

Description : A no-load test is performed on a transformer to determine?

Last Answer : A no-load test is performed on a transformer to determine magnetizing current and loss.

Last Answer : Short circuit test on transformers is conducted to determine copper losses.

Description : Polarity Test of Transformer

Last Answer : Polarity Test of Transformer

Description : If a 5-bus test system contains 6 transmission lines and one transformer, how many non-zero elements are there in the system Y-bus ? (A) 25 (B) 12 (C) 11 (D) 19

Last Answer : If a 5-bus test system contains 6 transmission lines and one transformer, 19 non-zero elements are there in the system Y-bus.

Description : Sumpner's test is conducted on transformer to determine?

Last Answer : Sumpner's test is conducted on transformer to determine temprature.

Last Answer : Open circuited armature coil of a D.C. machine is identified by the scarring of the commutator segment to which open circuited coil is connected and indicated by a spark completely around the commutator.

Last Answer : If the field winding of an unloaded salient pole synchronous motor is open circuited, the motor will stop.

Description : 66 While conducting short-circuit test on a transformer the following side is short circuited A. High voltage side B. low voltage side C. primary side D. secondary side

Last Answer : B. Low voltage side

Description : 30 In performing the short circuit test of a transformer A. high voltage is usually short circuited B. low voltage side is usually short circuited C. any side is short circuited with preference D. none of the above

Last Answer : B. Low voltage side is usually short circuited

Description : Equivalent circuit of transformer

Last Answer : Equivalent Circuit Diagram of Transformer Referred to Primary: V1 -Primary Input voltage I1 - Input Current I0- Exciting current/ No load current Im- Magnetizing component ... equivalent of secondary terminal voltage ZL- Load impedance ZL ′- Primary equivalent of load impedance

Description :  An AC supply of 230 V is applied to a half-wave rectifier circuit through a transformer having primary to secondary turn’s ratio 12:1. The peak inverse voltage is A) 8.62 V B) 12 V C) 19.17 V D) 27.11 V 

Last Answer :  An AC supply of 230 V is applied to a half-wave rectifier circuit through a transformer having primary to secondary turn’s ratio 12:1. The peak inverse voltage is A) 8.62 V B) 12 V C) 19.17 V D) 27.11 V 

Last Answer : The short circuit in any winding of the transformer is the result of impulse voltage.

Description : When secondary of a current transformer is open-circuited its iron core will be?

Last Answer : When secondary of a current transformer is open-circuited its iron core will be hot because of heavy iron losses taking place in it due to high flux density.

Description : During short circuit test iron losses are negligible because A. The current on secondary side is negligible B. The voltage on secondary side does not vary C. The voltage applied on primary side is low D. Full-load current is not supplied to the transformer

Last Answer : C) the voltage applied on primary side is low

Description : During short circuit test iron losses are negligible because A. The current on secondary side is negligible B. The voltage on secondary side does not vary C. The voltage applied on primary side is low D. Full-load current is not supplied to the transformer

Last Answer : C) the voltage applied on primary side is low

Description : What are the disadvantages of Open loop control system?

Last Answer : Open loop control system are less reliable. In open loop control system Optimization is not possible. Open loop control system are less accurate.

Description : Why CT is never operated with an open secondary ?

Last Answer : CT secondary should never be kept open because it will cause saturation of the core to a high level and very high voltage will appear across the secondary which can breakdown the insulation. One terminal of PT secondary is always grounded to avoid capacitive induction and for human safety

Description : The secondary of a current transformer is always short-circuited under operating conditions because it?

Last Answer : The secondary of a current transformer is always short-circuited under operating conditions because it avoids core saturation and high voltage induction.

Description : How to Open a Tight Jar Lid

Last Answer : How to Open a Tight Jar Lid There are instances when you buy a stubborn jar of pickles (Learn how to pickle), peanut butter or mayonnaise that you can't open with your hands. It can drive you ... no time. If you enjoy reading this article, you might as well read how to can fruits and vegetables.

Description : How to Open a Can without a Can Opener

Last Answer : How to Open a Can without a Can Opener You're dying to sink your teeth into those canned peaches, but you find yourself without any can opener. At times like this, many people would easily give up ... you'll soon find yourself enjoying the yummy contents of the can. Be careful not to spill the food!

Description : Open-Face Shrimp Melt

Last Answer : Open-Face Shrimp Melt - serves 2 Preparation - 15 minutes 3 ounces shelled and deveined cooked small shrimp, cut lengthwise into halves 1/4 cup chopped celery 2 tbsp chopped scallion (green ... baking sheet arrange sandwiches and broil 6 inches from heat source until cheese melts, about 1 minute.

Description : What will happen to the gain margin if the gain of the open loop system is doubled? A) Doubled B) Becomes half C) Is not affected D) Becomes one-fourth 

Last Answer : What will happen to the gain margin if the gain of the open loop system is doubled? A) Doubled B) Becomes half C) Is not affected D) Becomes one-fourth 

Description : If the gain of the open loop system is doubled, the gain margin  (1) Is not affected (2) Gets doubled (3) Becomes half (4) Becomes one -forth

Last Answer : If the gain of the open loop system is doubled, the gain margin Becomes half

Description : An open resistor, when checked with an ohm-meter reads?

Last Answer : An open resistor, when checked with an ohm-meter reads infinite.

Description : What is an example of an open loop system?

Last Answer : Open loop system. Ex. Electric heater, washing machine, fan, electric switch, etc

Description : What are the advantages of open loop control system?

Last Answer : Open loop control system are simple to design. Open loop control system are generally stable.

Description : what is open loop and close loop control system?

Last Answer : A) In open loop system the input is independent         of output but output is depends on input. A-1. no feedback path in open loop s/m    -2. less accuracy than close loop s/m. Ex. Washing ...    -3. high accuracy. Ex. Air conditioner ( AC ), rocket launcher, radar          system, etc

Description : Why the open circuit test on a transformer is conducted at rated voltage?

Last Answer : A:The open circuit on a transformer is conducted at a rated voltage because core loss depends upon the voltage. This open circuit test gives only core loss or iron loss of the transformer.

Description : 49 The open circuit test is carried out in a transformer to find the A. Cu loss B. Core loss C. Total loss D. Insulation resistance

Last Answer : B. Core loss

Description : With the help of neat diagram, describe the procedure to carry out phasing out test on a 3 phase transformer. Also state the purpose of conducting this test on 3 phase transformer.

Last Answer : i) This test is carried out on 3-ph transformer to identify primary & secondary winding belonging to the same phase. ii) As shown in fig above all primary & secondary phases ... of this test is to check the respective phases of primary & secondary windings in 3-ph transformer

Description : Why phasing out and polarity test is carried out on three phase transformer?

Last Answer : The phasing out test is carried out to identify the windings (primary and secondary) of corresponding phase of the three phase transformer. The polarity test is carried out to identify the ... identical polarity of the primary and secondary windings of each phase of the three phase transformer.

Description : 40 No load test on a transformer is carried out to find A. Copper loss B. magnetising current C. Magnetising current and loss D. Efficiency of the transformer

Last Answer : C. Magnetising current and loss

Description : 22 No load test on a transformer is carried out to find A. copper loss B. magnetising current C. Magnetising current and no load loss D. Efficiency of the transformer

Last Answer : C. Magnetising current and no load loss

Description : Define balanced and unbalanced load in three phase circuit.

Last Answer : Balanced Load: When all the imedances of 3 phases are equal in magnitude and of same nature then load is said to be balanced.  Unbalanced Load: When all the imedances of 3 phases are not equal in magnitude and of different nature then load is said to be unbalanced.

Last Answer : The duration of sudden short-circuit test on a synchronous motor is usually about one second.

Description : Why would a grown man have a problem with the bedroom door being closed at night?

Last Answer : He can't be aware of what is going on in the house if the door is closed, may make him uncomfortable and unable to relax and sleep. I do this so if anything happens at night I stand a ... Some rooms just get stuffy when people are sleeping in the same closed up area. He could also be claustraphobc.

Description : If there was one day a week where you only had to work half a day, would you opt to sleep in and go in later in the morning, or get up early and leave work early in the afteroon?

Last Answer : I would personally choose to go in early and leave early. But it really depends on the job. If I really like the job, I might work the full day even if I didn’t have to.

Description : State any two commands for managing disk space and also state their use

Last Answer : There are primarily two commands that can be used for managing Disk space: 1. df 2. du 1. df - disk filesystem df command (short for disk filesystem) is used to show disk utilization ... the disk space used by files on a machine and crucial for disk space management on unix and linux systems.

Description : Explain about the open and short circuit tests on transformer?

Last Answer : A. Open circuit test (No load test) and short circuit test (full load test) are performed on a transformer to determine (i) Equivalent circuit of transformer (ii) Voltage ... determine copper loss in transformer at full load and parameters of approximate equivalent circuit of transformer.

Description : Why SC test is generally performed on HV side of a transformer?

Last Answer : The rated current is less on HV side. This will also permit to use ammeter and wattmeter of lower current range.