The use of thermocouple meters for AC measurement leads to a meterscale which is _____.

1 Answer

Answer :

 The use of thermocouple meters for AC measurement leads to a meterscale which is square law.

Related questions

Description : What is the equation for resistance measurement of PT 100 thermocouple? 

Last Answer : °C = (R-100) / 0.39  

Description : Temperature of hot gases flowing in a pipe is measured by a thermocouple inserted in the thermal well. The thermal well made of __________ will facilitate the most accurate measurement of the temperature. (A) Copper (B) Steel (C) Aluminium (D) Brass

Last Answer : Option A

Description : Temperature of hot gases flowing in a pipe is measured by a thermocouple inserted in the thermal well. The thermal well made of __________ will facilitate the most accurate measurement of the temperature. (A) Copper (B) Steel (C) Aluminium (D) Brass

Last Answer : Option A

Description : Thermocouple is used to measure a) AC b) DC c) Both d) None

Last Answer : Ans: Both

Description : Before measuring an unknown resistance with an ohmmeter, you should _____________. A. adjust the meter's pointers to mid-scale B. change the meter's batteries C. center the meter's pointer at infinity D. short the test leads and calibrate the meter

Last Answer : Answer: D

Description : Before measuring an unknown resistance with an ohmmeter, you should _____________. A. adjust the meter's pointer to mid-scale B. short the test leads and calibrate the meter reading to 'zero' C. change the meter's batteries D. center the meter's pointer at infinity

Last Answer : Answer: B

Description : State seeback effect. Describe the working of thermocouple.

Last Answer : Seebeck effect: Seebeck effect states that whenever two dissimilar metals are connected together to form two junctions out of which, one junction is subjected to high temperature and another is subjected to ... both the junctions a very low emf is produced which causes a current in the circuit. 

Description : State working principle of thermocouple.

Last Answer : Working principle of thermocouple. When heat is applied to junction (hot junction) of the two dissimilar metals, an emf is generated which can be measured at the other junction (cold junction). The two ... as a result of the generated emf. This current will continue to flow as long as T1>T2.

Description : List applications of thermocouple and thermistors.

Last Answer : Applications of Thermistors: 1. Widely used in the applications of the range from - 60oC to + 15oC. 2. Used as a sensor in liquid level, pressure, flow measurement systems. 3. Used for measurement ... 2. It is used for temperature measurement in cryogenic range. 3. It is used for flow measurement.

Description : Principle of Thermocouple is based on :  (A) Thomson effect (C) Seebeck effect (B) Peltier effect (D) Kelvin effect

Last Answer :  The  principle is  based on Seebeck   effect.

Description : Consider the following transducers : 1. LVDT 2. Piezoelectric 3. Thermocouple 4. Photovoltaic cell  Which of the above are active transducers ?

Last Answer : Consider the following transducers : 1. LVDT 2. Piezoelectric 3. Thermocouple 4. Photovoltaic cell Which of the above are active transducers ? 2, 3 and 4

Description : What are the applications of thermocouple?

Last Answer : Used  as  a  rectifier  instrument.

Description : The two watt meters measurement the ratio of two meter readings is –(1-sqrt3):( 1+sqrt3) then the power factor is a) 1 b) 0.866 c) 0.707 d) 0

Last Answer : Ans: 0.707

Description : Write the names of any four flow meters used for flow measurement.

Last Answer : Flow meters used for flow measurement : Rotating vane meter, ultrasonic flow meter, Piston type flow meter, thermal flow meter, electromagnetic flow meter.

Last Answer : Baretters and bolo meters are used for measurement of microwave power.

Description : Which of the following methods should be used to test for an 'open' coil in an AC motor stator? A. Test with an ohmmeter, one test lead on the shaft, and the other test lead to the stator leads ... an open coil. D. Use a growler, listening for noise and vibration to increase when over an open coil.

Last Answer : Answer: B

Description : In order to determine whether or not 'fuse 2' shown in the illustration is defective, you should connect the voltage tester leads across points _____________. EL-0062 A. AC B. AD C. BC D. BD

Last Answer : Answer: B

Description : In order to determine whether or not 'Fuse 1', shown in the illustration is defective, you should connect the voltage tester leads across points _____________. EL-0062 A. AC B. AD C. BC D. BD

Last Answer : Answer: C

Description : When reading AC current with the multimeter shown in the illustration and you are unsure of the range, the range switch should be set to ___________. EL-0047 A. 10 MA/ 10 AMP with leads in the (-10 A ... leads in the (-COMMON) and (+10 A) jacks D. unable to measure AC current with this multimeter

Last Answer : Answer: D

Description : When an AC or a DC motor fails to start, the FIRST step in troubleshooting should be to check the ____________. A. motor windings for obvious opens B. motor controller leads for continuity C. fuse or circuit breaker D. motor controller leads for grounds

Last Answer : Answer: C

Description : When attempting to measure AC current with the device shown and you are unsure of the range, the range switch should be set to __________. EL-0047 A. 10 MA / AMPS with leads in the (-10 A) and ... (-COMMON) and (+10 A) jacks D. unable to accurately measure AC current with this device as illustrated

Last Answer : Answer: D

Description : The leads from a megohmmeter are attached to the leads of an AC motor field coil. A reading of infinity is obtained indicating a/an ____________. A. open field coil B. shorted field coil C. grounded field coil D. shunted field coil

Last Answer : Answer: A

Description : The reversal of an AC, three-phase, induction motor is accomplished by ______________. A. changing all three motor leads B. reversing the position of the slip rings C. interchanging any two of the three motor leads D. interchanging any two brushes

Last Answer : Answer: C

Description : What leads in a simple synchro system are connected to the ac power line?

Last Answer : The rotor leads.

Description : Why PM-MC meters can't be used for AC measurements?

Last Answer : It wont work for AC measurements. Not designed for ACapplication

Description : In AC circuits, AC meters measure – (1) mean values (2) rms values (3) peak values (4) mean square values

Last Answer : (2) rms values Explanation: Voltages and currents for AC circuits are generally expressed as rms (root mean square) values. For a sine wave, the relationship between the peak and the rms average is: rms value = 0.707 peak value.

Description : In AC circuits, AC meters measure?

Last Answer : RMS values

Description : In AC circuits, AC meters measure (1) mean values (2) rms values (3) peak values (4) mean square values

Last Answer : rms values

Description : What is the purpose of rotor AC Impedance measurement?

Last Answer : Periodic measurement of rotor impedance using an AC power supply is another means of detecting the presence of shorted turns in a rotor winding. Impedance measurement is more sensitive than the ... single shorted turn opposes the MMF of the entire coil, thus greatly reducing the reactance. 

Description : For measurement of radio frequency ac signals __________ type meter is used

Last Answer : For measurement of radio frequency ac signals thermo-couple type meter is used

Description : state properties that makes thermocouple very sensitive?

Last Answer : it measures temperatures between -250 and 1600 degree and it can measure a wider range of temperatures

Description : What is Thermocouple ?

Last Answer : : Thermocouple is a metalic bar that can be used to measure the temperature of a place. Thermocouple is an analog sensor. It is used to measure temperature. In thermocouples thermo or tharmal means ... has two terminals, one positive and the other negative. It is measured in meter voltage mode.

Description : Thermocouple How It is Work By ?

Last Answer : Thermocouple A metalic bar , whose With the help No Of space Temperature Measurement To do Goes Thermocouple a _ Analog Sensor This is it Temperature Measurement To do At work Use Is . ???? ... _ Two Terminal Stays A Positive And The other Negative. This Meters Voltage Mode To measure Is.

Description : What is the energy conversion for a thermocouple?

Last Answer : A thermocouple uses the thermoelectric effect to do what it does. Thermal energy (heat) is converted into a difference of potential, which is electric (electromagnetic) energy.

Description : The instrument used to regulate temperature to a particular degree is called : (1) Thermostat (2) Thermometer (3) Pyrometer (4) Thermocouple

Last Answer : (1) Thermostat Explanation: A thermostat is a component which senses the temperature of a system so that the system's temperature is maintained near a desired set point. At its core, a thermostat is simply the controls used to regulate temperature in a heating system.

Description : Conversion of heat into electrical er is achieved by using – (1) Ammeter (2) Hydrometer (3) Voltmeter (4) Thermocouple

Last Answer : (4) Thermocouple Explanation: Thermoelectric generators convert thermal energy into electricity by using heat from the body - or any object with a temperature gradient - as their energy source. ... energy into electricity. Bismuth telluride and its alloys are commonly used in thermocouples.

Description : The sensor connected to 'signal conditioner' (6000F125) shown in the illustration is a/an ______________. EL-0094 A. thermocouple B. transducer C. inverter D. RTD

Last Answer : Answer: B

Description : The sensor connected to 'signal conditioner' (6000AH170) shown in the illustration is a/an _____________. EL-0094 A. thermocouple B. transducer C. inverter D. RTD

Last Answer : Answer: A

Description : The sensor connected to 'signal conditioner' (6000F085) shown in the illustration is a/an ______________. EL-0094 A. thermocouple B. transducer C. inverter D. RTD

Last Answer : Answer: D

Description : Which sensor shown in the illustration develops its own conditioning and point setting and 'reports' directly to the 'annunciator'? EL-0094 A. Transducer B. Resistance Temperature Detector (RTD) C. Pressure Switch D. Thermocouple

Last Answer : Answer: C

Description : Which of the following devices should be used to measure the temperature of a battery electrolyte? A. Mercury thermometer B. Alcohol thermometer C. Thermocouple pyrometer D. Potentiometer

Last Answer : Answer: B

Description : Thermocouple is suitable for measuring (A) Liquid temperatures only (B) Very high temperatures only (C) Very low temperatures only (D) Both high and low temperatures

Last Answer : (D) Both high and low temperatures

Description : When a bare thermocouple is covered by a protective sheath, the response becomes (A) Faster and oscillatory (B) Faster and non-oscillatory (C) Slower and oscillatory (D) Slower and non-oscillatory

Last Answer : (D) Slower and non-oscillatory

Description : An alloy used as thermocouple material comprises of 40% nickel and60% copper. It is called (A) Constantan (B) Kanthal (C) Chromel (D) German silver

Last Answer : (A) Constantan

Description : State some thermocouple. 

Last Answer : Copper – constantan, Iron – constantan.  

Description : The following thermocouple may be used for measuring temperature upto 1873°K. (A) Chromel-alumel (B) Copper-constantan (C) Platinum-platinum rhodium (D) Iron-constantan

Last Answer : (C) Platinum-platinum rhodium

Description : Pressure is measured with the help of A. Manometer. C) Thermocouple. B. Ammeter. D) Orifice plate.

Last Answer : manometer

Description : What device measures infrared radiation below?  a. thermocouple  b. thermopile  c. thermodynamic device  d. thermos

Last Answer : thermopile

Description : A _______ is used to measure the stator % winding temperature of the generator. (a) thermocouple (b) pyrometer (c) resistance thermometer (d) thermometer

Last Answer : (c) resistance thermometer

Description : To protect most of the electrical equipment handling low power, the types of relays used are (a) thermocouple (b) electronic and bimetallic (c) both (a) and (b) (d) none of the above

Last Answer : (c) both (a) and (b)