As compared to a split phase motor, a capacitor start motor has _____.

1 Answer

Answer :

 As compared to a split phase motor, a capacitor start motor has higher starting torque.

Related questions

Description : A ceiling fan uses (A) split-phase motor. (B) capacitor start and capacitor run motor. (C) universal motor. (D) capacitor start motor.

Last Answer : Ans: D To give starting torque and to maintain speed.

Description : Split phase induction motor

Last Answer : Split phase induction motor : There are two windings used in split phase induction motor. It is a type of single-phase induction motor. There are two winding one is called main winding and ... motor have low starting torque it is used for small fans, blowers, centrifugal pumps, grinders etc.

Description : In case of split phase motor, the phase shift between currents in the two windings is around  A) 30° B) 70° C) 90° D) 120°

Last Answer : In case of split phase motor, the phase shift between currents in the two windings is around  30°

Description : In a split-phase induction motor, the resistance/reactance ratios of windings are such that (A) current in the auxiliary winding leads the current in the main winding (B) current in the ... (C) both windings develop the same starting torque (D) both windings develop high starting current

Last Answer : In a split-phase induction motor, the resistance/reactance ratios of windings are such that current in the auxiliary winding leads the current in the main winding

Last Answer : In split phase motor main winding is of thick wire placed at the bottom of the slots.

Description : What is the main function in the use of a capacitor for starting a single phase motor? A. Reduce radio interference B. Split the phase to establish a rotating magnetic field C. Reduce the phase angle D. Prolong the life of the starting contacts

Last Answer : Answer: B

Last Answer : To reverse the direction of rotation of a capacitor start motor while it is running we should disconnect motor from the supply till it stops then reconnect it to supply with reversed connection of main or auxiliary winding.

Last Answer : If the centrifugal switch of a two-value capacitor motor using two capacitors fails to open then Electrolytic capacitor will, in all probability, suffer break down.

Last Answer : Two-value capacitor motor finds increased application as compressor motor in small home air-conditioners because it has low starting as well as running currents at relatively high power factor.

Last Answer : In a ceiling fan employing capacitor run motor secondary winding surrounds the primary winding.

Last Answer : The capacitors used in single-phase capacitor motors have no polarity marking.

Description : Which type of AC single-phase motor will also operate on direct current? A. Split-phase B. Series-wound C. Shaded-pole D. Repulsion-start

Last Answer : Answer: B

Description : The main purpose of the auxiliary winding on a split-phase, single-phase motor is to _____________. A. limit the starting voltage B. increase the starting current C. start the motor D. keep the motor running in the event the main winding should fail

Last Answer : Answer: C

Description : A single-phase induction motor having a relatively high starting torque, is the ___________. A. shaded pole motor B. wound-rotor motor C. capacitor-start motor D. resistance-start motor

Last Answer : Answer: C

Description : In a capacitor start single-phase induction motor, the capacitor is connected (A) in series with main winding. (B) in series with auxiliary winding. (C) in series with both the windings. (D) in parallel with auxiliary winding.

Last Answer : Ans: B To make single phase motor self start. We split the phases at 90 degree. Hence, motor behaves like a two phase motor.

Description : Explain the working of a single phase capacitor start induction motor. 

Last Answer : Single phase capacitor start induction motor https://youtu.be/31lvvzU5Puc

Description : For a single phase capacitor start induction motor, which of the following statements is valid?  A) The capacitor is used for power factor improvement B) The direction of rotation can be ... rotation cannot be changed D) The direction of rotation can be changed by interchanging the supply terminals

Last Answer : For a single phase capacitor start induction motor, which of the following statements is valid?  A) The capacitor is used for power factor improvement B) The direction of rotation can be ... cannot be changed D) The direction of rotation can be changed by interchanging the supply terminals

Description : In the capacitor-start, capacitor-run single-phase induction motor (A) two capacitors are connected across the main winding (B) when the centrifugal switch opens, the permanent capacitor is left ... left in the main winding circuit (D) two capacitors are connected across the auxiliary winding.

Last Answer : In the capacitor-start, capacitor-run single-phase induction motor when the centrifugal switch opens, the permanent capacitor is left in the auxiliary winding circuit

Description : A capacitor start, capacitor run single phase induction motor is basically a : -  a) ac series motor b) dc series motor c) 2 phase induction motor d) 3 phase induction motor

Last Answer : A capacitor start, capacitor run single phase induction motor is basically a : -  2 phase induction motor 

Description : In a capacitor start single-phase induction motor, the capacitor is connected in:  (A) series with the main winding (B) series with the auxiliary winding (C) series with both the windings (D) parallel with the auxiliary winding .

Last Answer : In a capacitor start single-phase induction motor, the capacitor is connected in: series with the auxiliary winding 

Last Answer : In a capacitor start single-phase motor, when capacitor is replaced by a resistance motor will continue to run in same direction.

Description : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will?

Last Answer : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will not start at all.

Last Answer : In a capacitor start motor, the phase displacement between starting and running winding can be nearly 90°.

Last Answer : A.C. series motor as compared to D.C. series motor has smaller brush width, less number of field turns, more number of armature turns, less air gap.

Description : Which statement is true concerning a split-phase induction motor? A. Motor rotation can be reversed without changing the windings or leads. B. Motor speed can be readily adjusted from zero to full ... proper wiring. D. Motor rotation can be reversed by reversing the leads on the starting winding.

Last Answer : Answer: D

Description : A split-phase induction squirrel-cage motor will not come up to speed, even though the rated voltage, rated frequency, and rated load are applied. The suspected trouble could be due to _____________. A. a faulty centrifugal switch B. broken rotor bars C. worn bearings D. all of the above

Last Answer : Answer: D

Description : If the centrifugal switch or relay used for cutting out the starting winding of a split-phase induction motor fails to open once the motor is in operation, the _____________. A. motor will overspeed B ... C. motor will immediately stall under load D. motor torque will be above normal at rated speed

Last Answer : Answer: B

Description : Which of the following problems will most likely occur if the starting winding of a split-phase induction motor failed to cutout once the motor was in continuous operation? A. The motor will overspeed. B. The ... reduced speed. C. A time delay will stop the motor. D. The winding will burn out.

Last Answer : Answer: D

Description : The variable resistance placed in the rotor circuit of a wound-rotor induction motor provides for __________. A. speed control B. frequency control C. voltage control D. use as a split-phase motor

Last Answer : Answer: A

Description : How the speed of rotation of a split phase induction motor is reversed?

Last Answer : The terminal connections of the starting windings are reversed with respect to main running windings..

Description : Why is the starting torque of a resistance split-phase induction motor not high?

Last Answer : The starting torque is given as, Ts = K Im Is Sin Ф Where K = constant whose magnitude depends upon the design of the motor (i) The angle between Is and Im is small ... Im are not equal in magnitude, the rotating magnetic field is not uniform and the starting torque produced is small.

Description : What is the draw back of the resistance split-phase induction motor?

Last Answer : The starting winding has a relatively small number of turns of fine wire and its resistance is higher than that of the main winding. Therefore the current density is high and the winding heats up quickly. ... begins to smoke and may burn out unless the motor is protected by a built-in-thermal relay.

Description : Explain the working of resistance split phase induction motor with a neat diagram.

Last Answer : Circuit diagram of resistance split single phase induction motor:   * Working of resistors split single phase induction motor: To make a single phase induction motor self-starting, we ... function is to automatically disconnected the starting winding from the supply Once motor is started. 

Last Answer : In split-phase motor auxiliary winding is of thin wire placed at the top of the slots.

Last Answer : Direction of rotation of a split phase motor can be reversed by reversing the connection of either running winding or starting winding.

Last Answer : In a split phase motor the starting winding is connected through a centrifugal switch.

Last Answer : In a split phase motor, the running winding should have low resistance and high inductance.

Description : For a 1.8o, 2-phase bipolar stepper motor, the stepping rate is 100 steps/second. The rotational speed of the motor in rpm is  (A) 15 (B) 30 (C) 60 (D) 90

Last Answer : For a 1.8o, 2-phase bipolar stepper motor, the stepping rate is 100 steps/second. The rotational speed of the motor in rpm is 30 

Description : A 400 V, 50 Hz 30 hp, three-phase induction motor is drawing 50 A current at 0.8 power factor lagging. The stator and rotor copper losses are 1.5 kW and 900 W respectively. The friction and windage losses are 1050 W and the ... the motor will be (A) 23.06 kW (B) 24.11 kW (C) 25.01 kW (D) 26.21 kW

Last Answer : A 400 V, 50 Hz 30 hp, three-phase induction motor is drawing 50 A current at 0.8 power factor lagging. The stator and rotor copper losses are 1.5 kW and 900 W respectively. The friction and windage losses are 1050 W and the core losses are 1200 W. The air-gap power of the motor will be 25.01 kW

Description : The locked rotor current in a 3-phase, star connected 15 , kW 4 , pole 230 V , 50 Hz induction motor at rated conditions is 50 A. Neglecting losses and magnetizing current, the approximate locked rotor line current drawn when the motor ... Hz supply is  (A) 58.5 A (B) 45.0 A (C) 42.7 A (D) 55.6 A

Last Answer : The locked rotor current in a 3-phase, star connected 15 , kW 4 , pole 230 V , 50 Hz induction motor at rated conditions is 50 A. Neglecting losses and magnetizing current, the approximate locked rotor line current drawn when the motor is connected to a 236 , V 57 Hz supply is 45.0 A 

Description : The speed of a three-phase induction motor is controlled by variable voltage variable frequency control (i.e. keeping V/f constant). As the frequency is reduced, the slip at maximum torque  (1) Decreases (2) Increases (3) Remains constant (4) None of the above

Last Answer : The speed of a three-phase induction motor is controlled by variable voltage variable frequency control (i.e. keeping V/f constant). As the frequency is reduced, the slip at maximum torque Increases 

Description : Torque developed by a three-phase, 400V, induction motor is 100 N -m. If the applied voltage is reduced to 200-V, the d'veloped torque will be

Last Answer : Torque developed by a three-phase, 400V, induction motor is 100 N -m. If the applied voltage is reduced to 200-V, the d'veloped torque will be 25 N -m

Description : The slip of 400 V, three phase, 4 -pole induction motor when rotating at 1440 rpm is 

Last Answer : The slip of 400 V, three phase, 4 -pole induction motor when rotating at 1440 rpm is 4 percent

Description : A 400 V, 50 Hz three-phase induction motor rotates at 1440 rpm on full -load. The motor is wound for

Last Answer : A 400 V, 50 Hz three-phase induction motor rotates at 1440 rpm on full -load. The motor is wound for 4 poles

Description : The speed of a 2-pole, 3-phase stepper motor operated by 1200 pulses/min (A) 100 rpm (B) 200 rpm (C) 400 rpm (D) 800 rpm

Last Answer : The speed of a 2-pole, 3-phase stepper motor operated by 1200 pulses/min 200 rpm

Description : In a single-phase induction motor when the rotor is stationary and voltage is applied to the stator, then (A) the flux is constant (B) the flux first decreases and then increases in ... increases and decreases in the opposite direction with the same magnitude (D) current flows through the rotor

Last Answer : In a single-phase induction motor when the rotor is stationary and voltage is applied to the stator, then the flux first decreases and then increases in the same direction

Description : A 3-phase, 4-pole, 50Hz induction motor runs at a speed of 1440 rpm. The rotating field produced by the rotor rotates at a speed of ________ rpm with respect to stator field. (A) 1500 (B) 0 (C) 1440 (D) 60

Last Answer : 0

Description : An 8-pole, 50Hz, three-phase induction motor is running at 705rpm and has a rotor copper loss of 5kW. Its rotor input is (A) 5.06 kW (B) 0.3 kW (C) 100 kW (D) 83.33 kW

Last Answer : An 8-pole, 50Hz, three-phase induction motor is running at 705rpm and has a rotor copper loss of 5kW. Its rotor input is 83.33 kW

Description : The torque developed by any 3-phase induction motor at 0.8 p.u. slip is (A) Full-load torque (B) unstable torque (C) starting torque (D) break down

Last Answer : The torque developed by any 3-phase induction motor at 0.8 p.u. slip is unstable torque

Description : In a 3-phase slip-ring induction motor, the slip at some speed is 0.05. The speed is reduced by inserting an external resistance in the rotor circuit and the slip is 0.15. If the rotor winding resistance per phase is 0.2 Ω, the external resistance is (A) 0.2 Ω (B) 0.3 Ω (C) 0.4 Ω (D) 0.5 Ω

Last Answer : In a 3-phase slip-ring induction motor, the slip at some speed is 0.05. The speed is reduced by inserting an external resistance in the rotor circuit and the slip is 0.15. If the rotor winding resistance per phase is 0.2 Ω, the external resistance is 0.3 Ω