Full load current of an Induction motor is 20 Ampere. The no-load current may be expected to be: A) 25 Ampere to 28 Ampere B) 15 Ampere to 18 Ampere C) 11 Ampere to 14 Ampere D) 6 Ampere to 10 Ampere

2 Answers

Answer :

Full load current of an Induction motor is 20 Ampere. The no-load current may be expected to be:  6 Ampere to 10 Ampere

Answer :

D

Related questions

Description : A 400 V, 15 kW, 4-pole, 50 Hz, Y-connected induction motor has full load slip of 4%. The output torque of the machine at full load is  (A) 1.66 Nm (B) 95.50 Nm (C) 99.47 Nm (D) 624.73 Nm

Last Answer : A 400 V, 15 kW, 4-pole, 50 Hz, Y-connected induction motor has full load slip of 4%. The output torque of the machine at full load is 99.47 Nm

Description : The type of single-phase induction motor having the highest power factor at full load is (A) shaded pole type (B) split-phase type (C) capacitor-start type (D) capacitor-run type

Last Answer : The type of single-phase induction motor having the highest power factor at full load is capacitor-run type

Description : An induction motor having full load torque of 60 Nm when delta connected develops a starting torque of 120 Nm. For the same supply voltage if the motor is changed to star connection, the starting torque developed will be  A) 40 Nm B) 60 Nm C) 90 Nm D) 120 Nm

Last Answer : An induction motor having full load torque of 60 Nm when delta connected develops a starting torque of 120 Nm. For the same supply voltage if the motor is changed to star connection, the starting torque developed will be 40 Nm

Description : No-load test on a 3-phase induction motor was conducted at different supply voltage and a plot of input power versus voltage was drawn. This curve was extrapolated to intersect the y-axis. The intersection point ... ) Core loss (B) Stator copper loss (C) Stray load loss (D) Friction and windage loss

Last Answer : No-load test on a 3-phase induction motor was conducted at different supply voltage and a plot of input power versus voltage was drawn. This curve was extrapolated to intersect the y-axis. The intersection point yields Friction and windage loss

Description : The power factor of an induction motor under no load conditions will be close to (A) 0.2 lagging (B) 0.2 leading (C) 0.5 lagging (D) Unity

Last Answer : The power factor of an induction motor under no load conditions will be close to 0.2 lagging

Description : A 3-phase induction motor is driving a constant torque load at rated voltage and frequency. If both voltage and frequency are halved, following statements relate to the new condition if stator resistance, leakage reactance and core loss are ... (A) All (B) 1, 2 and 3 (C) 2, 3 and 4 (D) 1 and 4

Last Answer : A 3-phase induction motor is driving a constant torque load at rated voltage and frequency. If both voltage and frequency are halved, following statements relate to the new condition if stator resistance, leakage reactance and core loss are ... A) All (B) 1, 2 and 3 (C) 2, 3 and 4 (D) 1 and 4

Description : In a single phase induction motor driving a fan load, the reason for having a high resistance rotor is to achieve (A) low starting torque (B) quick acceleration (C) high efficiency (D) reduced size

Last Answer : In a single phase induction motor driving a fan load, the reason for having a high resistance rotor is to achieve quick acceleration

Description : The frequency (fr) of the rotor current in an induction motor is given by the expression (s = slip, f = supply frequency)

Last Answer : The frequency (fr) of the rotor current in an induction motor is given by the expression fr = (s. f ) (s = slip, f = supply frequency)

Description : The frequency of the rotor current in a 3 phase 50 Hz, 4 pole induction motor at full load speed is about (A) 50 Hz. (B) 20 Hz. (C) 2 Hz. (D) Zero.

Last Answer : (C) 2 Hz.

Description : Which statement out of the following is a wrong statement with regard to Induction motor? A) Auto-transformer starter is costlier to direct on line (DOL) starter B) DOL starter is used for ... Star delta starter connects the motor first in delta at the time of starting then in star for running

Last Answer : Which statement out of the following is a wrong statement with regard to Induction motor? A) Auto-transformer starter is costlier to direct on line (DOL) starter B) DOL starter is used for ... delta starter connects the motor first in delta at the time of starting then in star for running

Description : The stator of a 415V, 50 Hz, 4-pole slip ring Induction Motor is excited by rated frequency with slip rings open circuited. The rotor is made to rotate at a speed of 600 rpm in the opposite direction to the ... frequency of induced voltage across slip ring is A) 30 Hz B) 70 Hz C) 20 Hz D) 35 Hz

Last Answer : The stator of a 415V, 50 Hz, 4-pole slip ring Induction Motor is excited by rated frequency with slip rings open circuited. The rotor is made to rotate at a speed of 600 rpm in the opposite direction to the normal direction, The frequency of induced voltage across slip ring is 70 Hz

Description : Synchronous wattage of induction motor means: A) rotor input in watts B) stator input in watts C) combined stator and rotor input in watts D) shaft output in watts

Last Answer : Synchronous wattage of induction motor means: rotor input in watts 

Description : The stator mmf and rotor mmf of a 3-phase induction motor (A) are equal (B) rotate with slip speed (C) are opposite but rotate with synchronous speed (D) rotate with the same rotor speed 

Last Answer : a

Description : An 8 pole wound rotor induction motor operating on 60 Hz supply is driven at 1800 r.p.m. by a prime mover in the opposite direction of revolving magnetic field. The frequency of the rotor current is (a) 30 Hz (b) 60 Hz (c) 120 Hz (d) 180 Hz 

Last Answer : 30 Hz As the frequency of the rotor is given by  F= N*P/120 so from the above equation the frequency of the rotor current can be easily calculated  i.e. 1800×8/120=30 Hence the required value of rotor frequency is 30 Hz

Description : The rotor frequency for a 3-phase 6-pole, 1000 r.p.m. induction motor with a slip of 0.04 is (a) 2 Hz (b) 4 Hz (c) 6 Hz (d) 8 Hz  

Last Answer : 2hz is rotor frequency

Description : A 6-pole, 50Hz, 3-φ induction motor is running at 950 r.p.m. and has Cu loss of 5kW. The rotor input is (a) 10 kW (b) 95 kW (c) 100 kW (d) 9.5 kW 

Last Answer : s=(Ns-N)/Ns =(1000-950)/1000=0.05.rotor cu.loss= s*rotor inputwe have rotor cu loss=5kWtherefore, rotor input= rotor cu.loss/s                              =5kW/0.05                              =100 kW

Description : The ratio of rotor output to rotor input in an induction motor is 0.96. The slip of the motor is (a) 0.04% (b) 4% (c) 6% (d) 12%

Last Answer : The ratio of rotor output to rotor input in an induction motor is 0.96. The slip of the motor is 4%

Description : A 3-phase delta connected squirrel cage induction motor when started with a DOL starter has a starting torque of 600 NM. Its starting torque when star delta starter is used:

Last Answer : A 3-phase delta connected squirrel cage induction motor when started with a DOL starter has a starting torque of 600 NM. Its starting torque when star delta starter is used: 200 NM

Description : In a 3-phase voltage source inverter used for speed control of induction motor, anti-parallel diodes are used across each switching device. The main purpose of diodes is to:

Last Answer : In a 3-phase voltage source inverter used for speed control of induction motor, anti-parallel diodes are used across each switching device. The main purpose of diodes is to: Allow the motor to return energy during regeneration

Description : A 3-phase induction motor is running at slip ‘s’. If its two supply leads are interchanged, then the operating slip at that instant will be:

Last Answer : A 3-phase induction motor is running at slip ‘s’. If its two supply leads are interchanged, then the operating slip at that instant will be: (2-s)

Description : If a 3-phase, 400V, 50Hz, 4 pole induction motor is running at a slip of 5% then the relative speed of rotor field with respect to stator filed is:

Last Answer : If a 3-phase, 400V, 50Hz, 4 pole induction motor is running at a slip of 5% then the relative speed of rotor field with respect to stator filed is: zero

Description : A three phase slip ring induction motor is fed from the rotor side with stator winding short circuited stator is: (1) Slip frequency (2) Supply frequency (3) Frequency corresponding to rotor speed (4) Zero

Last Answer : A three phase slip ring induction motor is fed from the rotor side with stator winding short circuited stator is: Slip frequency

Description : in a three-phase induction motor, the rotor field runs at the following speed with respect to the stator structure: 

Last Answer : in a three-phase induction motor, the rotor field runs at the following speed with respect to the stator structure: At synchronous speed in the direction of stator field

Description : A single-phase induction motor with only the main winding excited would exhibit the following response at synchronous speed  (A) Rotor current is zero (B) Rotor current is non-zero and is ... and backward rotating fields are equal (D) Forward rotating field is more than the backward rotating field

Last Answer : A single-phase induction motor with only the main winding excited would exhibit the following response at synchronous speed  (A) Rotor current is zero (B) Rotor current is non-zero and is ... backward rotating fields are equal (D) Forward rotating field is more than the backward rotating field

Description : The direction of rotation of a 3-phase induction motor is clockwise when it is supplied with 3-phase sinusoidal voltage having phase sequence A-B-C. For counter clockwise rotation of the motor, the phase sequence of the power supply should be  (A) B-C-A (B) C-A-B (C) A-C-B (D) B-C-A or C-A-B

Last Answer : The direction of rotation of a 3-phase induction motor is clockwise when it is supplied with 3-phase sinusoidal voltage having phase sequence A-B-C. For counter clockwise rotation of the motor, the phase sequence of the power supply should be  A-C-B 

Description : A three-phase cage induction motor is started by direct-on-line (DOL) switching at the rated voltage. If the starting current drawn is 6 times the full load current, and the full load slip is 4%, then ratio of the ... load torque is approximately equal to (A) 0.24 (B) 1.44 (C) 2.40 (D) 6.00

Last Answer : A three-phase cage induction motor is started by direct-on-line (DOL) switching at the rated voltage. If the starting current drawn is 6 times the full load current, and the full load slip is 4%, then ratio of the starting developed torque to the full load torque is approximately equal to 1.44

Description : The speed of a 4-pole induction motor is controlled by varying the supply frequency while maintaining the ratio of supply voltage to supply frequency (V/f ) constant. At rated frequency of 50 Hz and rated voltage of 400 V ... load torque is constant  (A) 882 rpm (B) 864 rpm (C) 840 rpm (D) 828 rpm

Last Answer : The speed of a 4-pole induction motor is controlled by varying the supply frequency while maintaining the ratio of supply voltage to supply frequency (V/f ) constant. At rated frequency of 50 Hz and rated voltage of 400 ... torque is constant  (A) 882 rpm (B) 864 rpm (C) 840 rpm (D) 828 rpm

Description : A three-phase squirrel cage induction motor has a starting torque of 150% and a maximum torque of 300% with respect to rated torque at rated voltage and rated frequency. Neglect the stator resistance and rotational losses. The ... maximum torque is  (A) 13.48% (B) 16.42% (C) 18.92% (D) 26.79%

Last Answer : A three-phase squirrel cage induction motor has a starting torque of 150% and a maximum torque of 300% with respect to rated torque at rated voltage and rated frequency. Neglect the stator resistance and rotational losses. The value of slip for maximum torque is 26.79%

Description : The slip of an induction motor normally does not depend on  (A) rotor speed (B) synchronous speed (C) shaft torque (D) core-loss component

Last Answer : The slip of an induction motor normally does not depend on core-loss component

Description : A 4-pole induction motor, supplied by a slightly unbalanced three-phase 50 Hz source, is rotating at 1440 rpm. The electrical frequency in Hz of the induced negative sequence current in the rotor is  (A) 100 (B) 98 (C) 52 (D) 48

Last Answer : A 4-pole induction motor, supplied by a slightly unbalanced three-phase 50 Hz source, is rotating at 1440 rpm. The electrical frequency in Hz of the induced negative sequence current in the rotor is 98 

Description : Leakage flux in an induction motor is  (A) flux that leaks through the machine (B) flux that links both stator and rotor windings (C) flux that links none of the windings (D) flux that links the stator winding or the rotor winding but not both

Last Answer : Leakage flux in an induction motor is  flux that links the stator winding or the rotor winding but not both

Description : When the supply voltage to an induction motor is reduced by 10%, the maximum torque will decrease by about  A) 5% B) 10% C) 20% D) 40%

Last Answer : When the supply voltage to an induction motor is reduced by 10%, the maximum torque will decrease by about 20%

Description : For a single phase capacitor start induction motor, which of the following statements is valid?  A) The capacitor is used for power factor improvement B) The direction of rotation can be ... rotation cannot be changed D) The direction of rotation can be changed by interchanging the supply terminals

Last Answer : For a single phase capacitor start induction motor, which of the following statements is valid?  A) The capacitor is used for power factor improvement B) The direction of rotation can be ... cannot be changed D) The direction of rotation can be changed by interchanging the supply terminals

Description : The actual speed of an induction motor is always • Less than synchronous speed • More than synchronous speed • Equal to synchronous speed • None of the above.

Last Answer : Less than the syncronous speed

Description : Consider the following statements: Star delta starter is used in 3-phase induction motor because it  1. Prevents heating of the motor winding  2. Ensures permissible minimum starting current  3. Is regulated by electricity ... and 4 are correct (c) 1, 3 and 4 are correct (d) 1 and 2 are correct 

Last Answer : Consider the following statements: Star delta starter is used in 3-phase induction motor because it  1. Prevents heating of the motor winding  2. Ensures permissible minimum starting current  3. Is regulated by ... and 4 are correct (c) 1, 3 and 4 are correct (d) 1 and 2 are correct 

Description : A three phase slip ring induction motor with chopper controlled resistance has its torque proportional to   (a) Rotor current (b) Stator resistance (c) Square of rotor current (d) Square root of rotor current 

Last Answer : A three phase slip ring induction motor with chopper controlled resistance has its torque proportional to Square of rotor current

Description : Crawling in an Induction motor is caused by (A) Low voltage supply (B) High loads (C) Harmonics developed in the motor (D) Improper design of the machine

Last Answer : Low voltage

Description : The number of poles in a phase induction motor at 50 Hz and running at 1500 rpm will be?

Last Answer : The number of poles in a phase induction motor at 50 Hz and running at 1500 rpm will be 4.

Last Answer : The repulsion-start induction-run motor is used because of high starting torque.

Last Answer : Single phase induction motor usually operates on 0.6 power factor lagging.

Last Answer : A single-phase induction motor is inherently non-self-starting with low torque.

Last Answer : The power factor of a single-phase induction motor is usually lagging.

Description : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will?

Last Answer : A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will not start at all.

Description : A three phase induction motor is drawing 16 Ampere at 440 Volts. If the operating power factor of the motor is 0.90 and the motor efficiency is 92%, then the mechanical shaft power output of the motor is a) 12.04 kW b) 10.09 kW c) 10.97 kW d) None of the above

Last Answer : b) 10.09 kW

Description : The torque and current curves for a three-phase induction motor with a cage rotor, are shown in the illustration. Which of the following statements is true concerning the depicted curves? EL-0056 A. As slip ... D. If the motor is loaded to the point where 40% slip has resulted, it will stall.

Last Answer : Answer: D

Description : In a 15 HP induction-type motor with a cage rotor, the current required at standstill to produce starting torque is approximately ____________. A. half the full load current B. equal to the full load current C. five times the full load current D. ten to twenty times the full load current

Last Answer : Answer: C

Description : A current `i` ampere flows in a circular arc of wire whose radius is `R`, which subtend an angle `3pi//2` radian at its centre. The magnetic induction

Last Answer : A current `i` ampere flows in a circular arc of wire whose radius is `R`, which subtend an angle `3pi//2` radian at ... 0)i)/(R )` D. `3mu_(0)i)/(8R)`

Description : Explain why the no load current of an induction motor is much higher than that of an equivalent transformer.

Last Answer : In induction motor, due to the presence of the air gap, the magnetizing current that is required to set up the flux is much higher. The working component of the current has to meet the ... eddy current loss, friction and windage losses. Hence the no load current of induction motor is higher.

Description : If an electric motor fails to start, you should FIRST check the _____________. A. phase sequence B. ampere load C. fuse or circuit breaker D. line frequency

Last Answer : Answer: C

Description : A 3 phase 50 Hz induction motor has full load speed of 970 rpm. Calculate no of poles and slip frequency.

Last Answer : The number of poles in an induction motor can be calculated using the following formula: No. of poles = (120 * frequency) / speed In this case, the number of poles would be calculated as follows: No. of poles = ( ... ) - 50 Hz = 8.08 Hz So the motor has 6 poles and a slip frequency of 8.08 Hz.