In an alternator if the winding is short pitched by 60 electrical degrees, its pitch factor will be: A) 1.0 B) 0.866 C) 0.75 D) 0.50

1 Answer

Answer :

 In an alternator if the winding is short pitched by 60 electrical degrees, its pitch factor will be: A) 1.0 B) 0.866 C) 0.75 D) 0.50

Related questions

Description : A 60 Hz, 2 pole alternator should run at • a. 3000 r.p.m. c. 1500 r.p.m. • b. 3600 r.p.m. d. 1800 r.p.m.

Last Answer : A 60 Hz, 2 pole alternator should run at 3600 r.p.m.

Description : A field excitation of 20 A in a certain alternator results in an armature current of 400 A in short circuit and a terminal voltage of 2000 V on open circuit. The magnitude of the internal voltage drop within the machine at a load current of 200 A is  (A) 1 V (B) 10 V (C) 100 V (D) 1000 V

Last Answer : 800

Description : At which power factor alternator is said to be overexcited?

Last Answer : At leading power factor alternator is said to be overexcited.

Description : The power factor of an alternator depends on?

Last Answer : The power factor of an alternator depends on load.

Description : In an alternator at lagging power factor the generated voltage per phase as compared to that at unity power factor?

Last Answer : In an alternator, at lagging power factor the generated voltage per phase as compared to that at unity power factor must be more than terminal voltage.

Description : What Are The Advantages And Disadvantages Of Short-pitched Winding?

Last Answer : The advantages are: They save copper for end connections They improve the waveform of the generated EMF. The generated EMF can be made to approximate to a sine wave more easily and the distorting ... some what reduced. Because the voltage induced in the two coil sides are slightly out of phase.

Description : What Is Meant By Short Pitched Winding?

Last Answer : If the coil span is less than the pole pitch, the winding is called as shot-pitched winding. It is also known as short-chorded winding.

Description : If the excitation of an alternator operating in parallel with other alternators decreased, its: (1) Power factor becomes more leading (2) Output Kw will change (3) Power factor becomes more lagging (4) Power factor becomes unity

Last Answer : If the excitation of an alternator operating in parallel with other alternators decreased, its: Power factor becomes more leading

Description : A 8 pole alternator rotates at 750 r.p.m. Its frequency is

Last Answer : A 8 pole alternator rotates at 750 r.p.m. Its frequency is 50 Hz

Description : State working principle of alternator. State the meaning self and separate excitation. 

Last Answer : Working principle of alternator: When a conductor is moved in magnetic field or a magnetic field moved with respect to conductor, according to Faraday's law of electromagnetic induction, the conductor ... like battery or shaft-mounted exciter, then the excitation is said to be separate excitation.

Description : Explain the construction of alternator with neat diagram.

Last Answer : Diagram: Construction of three phase alternator: Construction wise, an alternator generally consists of field poles placed on the rotating fixture of the machine i.e. rotor as shown in the ... of rotor used in construction of alternator, 1. Salient pole type. 2. Cylindrical rotor type. 

Description :  An 8-pole alternator runs at 750 rpm and supplies power to a 6-pole induction motor which has a full load slip of 3 percent. The full load speed of the induction motor will be: A) 1000 rpm B) 920 rpm C) 950 rpm D) 970 rpm

Last Answer : An 8-pole alternator runs at 750 rpm and supplies power to a 6-pole induction motor which has a full load slip of 3 percent. The full load speed of the induction motor will be: 970 rpm

Description :  The driving power from the prime-mover driving the alternator is lost but the alternator remains connected to the supply network; the field supply also remains on. The alternator will: A) ... as a synchronous motor but will rotate in a reverse direction to that corresponding to generator action 

Last Answer : The driving power from the prime-mover driving the alternator is lost but the alternator remains connected to the supply network; the field supply also remains on. The alternator will: behave as a synchronous motor and will rotate in the same direction

Description : Which alternator will have more number of poles ? (a) coupled to steam turbine (b) coupled to gas turbine (c) coupled to hydraulic turbine (d) None of the above 

Last Answer : b

Description : Drop in alternator frequency is corrected by: (1) Damper winding (2) Increased prime mover output (3) Automatic voltage regulator (4) None of these

Last Answer : Drop in alternator frequency is corrected by: Increased prime mover output

Description : Is the speed of alternator is directly proportional to frequency?

Last Answer : Yes, speed of alternator is directly proportional to frequency.

Description : The magnitude of various voltage drops that occur in an alternator depends on?

Last Answer : The magnitude of various voltage drops that occur in an alternator depends on load current.

Description : In alternator where the voltage drop occurs?

Last Answer : In alternator voltage drop occurs in armature resistance, leakage reactance, and armature reactance.

Description : Advantages of Short Pitch Coils for an Alternator

Last Answer : Advantages of Short Pitch Coils for an Alternator: (1) It gives better sinusoidal waveform by reducing the harmonic components. (2) It saves copper as length required for the connections is ... are illuminated, hysteresis & eddy current losses will be reduced and this increases the efficiency.

Description : What is the pitch factor of a 4 pole alternator having 36 slots and a coil span of 1 to 8?  (A) 140° (B) 80° (C) 20° (D) 40°

Last Answer : C

Description : Why is short pitch winding preferred over full-pitch winding ?

Last Answer : Advantages · Sinusoidal waveform: Waveform of the emf can be approximately made to a sine wave and distorting harmonics can be reduced or totally eliminated. · Economical :Conductor ... harmonics are eliminated, the eddy current and hysteresis losses are reduced which increases overall efficiency

Description : What is short pitch winding?

Last Answer : If coil pitch is equal to less than pole pitch it is called short pitch winding

Description : Harmonics are eliminated by using a) Skewing of rotor b) Distribution winding c) Short pitch winding d) All of the above

Last Answer : Ans: All of the above

Description : State advantages of short pitch winding over full pitch winding in alternators. 

Last Answer : Advantages of Short Pitch Winding over Full Pitch Winding in Alternators: 1) Short pitching reduces the amount of copper needed for end connection when compared with full pitched coil. 2) They ... reduced, thereby increasing the efficiency. 4) The power quality of generated emf is improved. 

Description : The visual and aural indications obtained when overflying an ILS middle marker are: a. Continuous low pitched dashes with synchronized blue light b. Continuous high pitched dots with synchronized amber ... dots and dashes with amber light d. One letter in Morse with synchronized white light

Last Answer : c. Alternating medium pitch dots and dashes with amber light

Description : What Is Meant By Full Pitched Winding?

Last Answer : If the coil span is equal to pole pitch, the winding is called as full pitched winding.

Description : Three factors responsible for the change in voltage as load is applied to an AC generator are: 1) the drop in resistance in the armature circuit, 2) the change in flux, and 3) the ____________. A. armature winding speed B. inductance load drop C. coil pitch factor D. armature reactance voltage drop

Last Answer : Answer: D

Description : The number of electrical degrees ‘passed through’ in one revolution of a 6-pole synchronous alternator is: A) 360 degree B) 720 degree C) 1080 degree D) 2160 degree

Last Answer : 1080

Description : To remove an alternator operating in parallel with another unit from the main electrical bus, you must FIRST _________. A. adjust the power factor on both units B. set the desired voltage on ... C. open the circuit breaker on the outgoing alternator D. remove the load from the outgoing alternator

Last Answer : Answer: D

Description : I have a high pitched electrical squeal in my room. Cannot locate the source.

Last Answer : answer:Do you live in an apartment? You may be hearing something in your walls or from your neighbors. Is there an air conditioning unit, vent, gutter, or machine of any sort near your room outside?

Description : The fractional-pitch used for eliminating 7th harmonic from the emf wave of an alternator is (A) 2/3 (B) 5/6 (C) 7/8 (D) 6/7

Last Answer : The fractional-pitch used for eliminating 7th harmonic from the emf wave of an alternator is 6/7

Description : Which type of winding is preferred for armature windings of alternator? Why?

Last Answer : Double layer, short pitched and distributed type of armature winding. It eliminates high frequency harmonics hence it makes induced emf more sinusoidal.

Description : At dead short circuit at terminals of Alternator then the current I is a) ZPF Lag b) ZPF lead c) Unity power factor d) 0.8 Power factor lag

Last Answer : Ans: ZPF Lag

Description : Is winding up for the pitch kinetic or potential energy?

Last Answer : Potential

Description : What is full pitch winding?

Last Answer : If coil pitch is equal to pole pitch it is called full pitch winding

Description : The distance between the starts of two consecutive coils measured in terms of coil sides is called (a) front pitch (b) winding pitch (c) commutator pitch (d) back pitch

Last Answer : (b) winding pitch

Description : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively

Last Answer : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively 19,17

Last Answer : In the case of lap winding resultant pitch is difference of front and back pitches.

Last Answer : In case of a 4-pole D.C. generator provided with a two layer lap winding with sixteen coils, the pole pitch will be 8.

Last Answer : In D.C. machines fractional pitch winding is used to reduce the sparking.

Description : When paralleling two alternators, the synchronizing lamps remain lit as the synchroscope pointer approaches the 0°. This indicates the _____________. A. incoming alternator is running too fast B. alternator ... apart C. synchroscope is defective or broken D. alternator power factors are in phase

Last Answer : Answer: C

Description : An electrical device which employs a stationary armature and a rotating electromagnetic field is used aboard ship as a ____________. A. magnetic amplifier B. ship's service alternator C. three-wire DC generator D. saturable core reactor

Last Answer : Answer: B

Description : The battery has following three major functions to perform: a) To provide a source of current for engine starting, lighting and use of horn. b) To help control the voltage in the electrical system. c ... the current produced by dynamo/alternator and to furnish the current d) all of the above. Ans. d

Last Answer : ans d

Description : Two 3-phase, Y-connected alternators are to be paralleled to a set of common busbars. The armature has a per phase synchronous reactance of 1.7 Ohm and negligible armature resistance. The line voltage of the first machine is adjusted to ... will be  (A) 16.98 A (B) 29.41 A (C) 33.96 A (D) 58.82 A

Last Answer : Two 3-phase, Y-connected alternators are to be paralleled to a set of common busbars. The armature has a per phase synchronous reactance of 1.7 Ohm and negligible armature resistance. The ... instant they are paralleled. Under this condition, the synchronizing current per phase will be 16.98 A

Description : Salient pole rotor is use for which speed?

Last Answer : Salient pole rotor is use for low and medium speed prime movers.

Description : Which rotor is use for high speed in turbo alternators?

Last Answer : Non-salient pole rotor is used for high speed in turbo alternators.

Description : When a CT is on electrical zero, what is the relationship between its rotor and the S2 winding?

Last Answer : They are perpendicular to each other.

Description : A pole pitch in electrical machine is: (1) Equal to 180° electrical (2) Equal to 180° mechanical (3) Less than 180° electrical (4) Greater Than 180° electrical

Last Answer : A pole pitch in electrical machine is: Equal to 180° electrical

Description : An alternator is being paralleled with one on the line. At the INSTANT the circuit breaker is closed, the frequency of the incoming alternator will normally _____________. A. increase B. not change C. decrease D. be exactly 60 hertz

Last Answer : Answer: C