In the measurement of power of balanced load by two wattmeter method in a 3-phase circuit, The readings of the wattmeters are 4 kW and 2 kW respectively, the later is being taken after reversing the connections of current coil. the power factor and reactive power of the load is A) 0.2 & 6 kVAR B) 0.2 & 6 √3 kVAR C) 0.32 & 2 kVAR D) 0.32 & 2 √3 kVAR

1 Answer

Answer :

 In the measurement of power of balanced load by two wattmeter method in a 3-phase circuit, The readings of the wattmeters are 4 kW and 2 kW respectively, the later is being taken after reversing the connections of current coil. the power factor and reactive power of the load is 0.2 & 6 √3 kVAR

Related questions

Description : In a 3-phase power measurement by two wattmeter method, both the watt meters had identical readings. The power factor of the load was?

Last Answer : In a 3-phase power measurement by two wattmeter method, both the watt meters had identical readings. The power factor of the load was unity.

Last Answer : In the case of power measurement by two wattmeter method in a balanced 3Φ system with a pure inductive load both the Wattmeter will indicate the same but of opposite sign.

Description : In the measurement of power by two wattmeter method, when the readings of the two wattmeters are equal, the power factor is (A) Zero (B) Leading (C) Lagging (D) Unity

Last Answer : In the measurement of power by two wattmeter method, when the readings of the two wattmeters are equal, the power factor is Unity

Description : The power consumed by a balanced 3-ph load is measured by two-wattmeter method. The meter readings are 8 kW and 4 kW. The power factor of the load is (A) zero (B) 0.5 (C) between zero and 0.5 (D) between 0.5 and unity

Last Answer : The power consumed by a balanced 3-ph load is measured by two-wattmeter method. The meter readings are 8 kW and 4 kW. The power factor of the load is between 0.5 and unity

Description : For power measurement of three phase circuit by two wattmeter method, when the value of power factor is less than 0.5 lagging:

Last Answer : For power measurement of three phase circuit by two wattmeter method, when the value of power factor is less than 0.5 lagging: One of the wattmeter connections will have to be reversed

Description : Measurement of power and power factor of a 3-phase system by two wattmeter method can be obtained in case of  1. Balanced load and balanced source  2. Balanced source with 3-phase 3-wire unbalanced load  3. Unbalanced source with 3-phase 3 ... b) 2, 3 and 5 (c) 1, 2, 3, 4 and 5 (d) 1, 2, 3 and 5 

Last Answer : Measurement of power and power factor of a 3-phase system by two wattmeter method can be obtained in case of  1. Balanced load and balanced source  2. Balanced source with 3-phase 3-wire unbalanced load  3. Unbalanced source with 3- ... b) 2, 3 and 5 (c) 1, 2, 3, 4 and 5 (d) 1, 2, 3 and 5 

Description : In a 3-phase power measurement by two wattmeter method the reading of one of the wattmeter was zero. The power factor of the load must be?

Last Answer : In a 3-phase power measurement by two wattmeter method the reading of one of the wattmeter was zero. The power factor of the load must be 0.5.

Description : The minimum number of wattmeter(s) required to measure 3-phase, 3-wire balanced or unbalanced power is  A) 1 B) 2 C) 3 D) 4

Last Answer : B

Last Answer : The power measurement in a balanced 3-phase circuit can be done by: One wattmeter method, Two wattmeter method, Three wattmeter method.

Description : While measuring power in a three phase load by two wattmeter method, the reading of two wattmeter are equal and opposite, when (a) load is balanced (b) power factor is unity (c) phase angle is between 60° to 90° (d) the load is purely inductive 

Last Answer :  Option (d)  Load is purely inductive 

Description : Draw the circuit diagram for:- i) Measurement of active power in 3-phase load circuit using two wattmeter. ii) Measurement of reactive power in 3-phase load circuit using one wattmeter.

Last Answer : (i) Measurement of active power in 3- phase load circuit using two- wattmeter: (ii) Measurement of reactive power in 3- phase load circuit using one wattmeter

Description : Two wattmeter method is employed to measure power in a 3 -phase balanced system with the current coil connected in the A and C lines. The phase sequence is ABC. If the wattmeter with its current coil in A -phase line reads zero, then the power factor of the 3 -phase load will be

Last Answer : Two wattmeter method is employed to measure power in a 3 -phase balanced system with the current coil connected in the A and C lines. The phase sequence is ABC. If the wattmeter with its current coil in A -phase line reads zero, then the power factor of the 3 -phase load will be 0.5 lagging.

Description : Draw and explain the circuit diagram for measurement of single phase power using dynamometer type wattmeter. 

Last Answer : Circuit diagram for measurement of single phase power using dynamometer type wattmeter: Explanation: It consists of two stationary coils, called current coils and one moving coil, called voltage or ... i.e. power. The meter can be calibrated directly to indicate the power in watts. 

Description : State any two disadvantages of one wattmeter method of measurement of 3 phase power.

Last Answer : State any two disadvantages of one wattmeter method of measurement of 3 phase power. Disadvantages of one wattmeter method:- 1. Only used for balanced load 2. It can not be used for ... connection then neutral point must be available 4. Delta connection must be opened to connect current coil.

Description : Explain the effect of power factor on wattmeter reading in two wattmeter method for power measurement.

Last Answer : Effect of P.F. on Reading of Wattmeter in Two Wattmeter Method:

Description : In two -wattmeter method of power measurement, if one wattmeter shows negative reading, then the power factor of the circuit is treated as (A) Unity (B) Lagging (C) Leading (D) Zero

Last Answer : Lagging   power   factor.

Description : The current coil of a wattmeter is connected to the CT of R-phase. The potential coil is connected across Y and B phases. The wattmeter measures

Last Answer : The current coil of a wattmeter is connected to the CT of R-phase. The potential coil is connected across Y and B phases. The wattmeter measures Reactive power of R phase.

Last Answer : The resistance in the circuit of the moving coil of a dynamometer wattmeter should be high.

Description : The power delivered to a three-phase load can be measured by the use of 2 wattmeter only when the A. Load is balanced B. 3 -phase load is connected to the source through 3 wires C. Load is unbalanced D. 3 -phase load is connected to the source through 4 wires

Last Answer : The power delivered to a three-phase load can be measured by the use of 2 wattmeter only when the  Load is unbalanced

Description : Illustrate how can you use a single-phase wattmeter to measure 3 phase reactive power in a circuit?

Last Answer : We can measure reactive power of 3 phase circuit by dingle phase wattmeter by connecting the current coil in series with a line or load and connecting the pressure coil across the other two lines.  Reactive power = 3√ V * I * sinϕ Watts. 

Description : Define balanced and unbalanced load in three phase circuit.

Last Answer : Balanced Load: When all the imedances of 3 phases are equal in magnitude and of same nature then load is said to be balanced.  Unbalanced Load: When all the imedances of 3 phases are not equal in magnitude and of different nature then load is said to be unbalanced.

Description : Power (P) in a 3 phase circuit with two watt meters at unity power factor is (W1 & W2 = watt meter readings)

Last Answer : Power (P) in a 3 phase circuit with two watt meters at unity power factor is P = W1 + W2 (W1 & W2 = watt meter readings)

Description : Consider the following statements  1) The compensating coil of a low power factor wattmeter compensates the effect of the impedance of the current coil ii) The compensating coil of a low power factor wattmeter compensates the effect ... C) Both (i) and (ii) are true D) Both (i) and (ii) are false

Last Answer : A

Last Answer : In a low power factor wattmeter the compensating coil is connected in series with pressure coil.

Last Answer : In a low power factor wattmeter the pressure coil is connected to the load side of the current coil.

Description : The potential coil of a single phase dynamometer wattmeter has 4840 Ohm resistance. Voltage across the load is 220 V. With the potential coil connected on the load side, the meter indicates 100 W. Approximate percentage error due to wattmeter connection is (A) 11% (B) 9% (C) 1.1% (D) 3%

Last Answer : The potential coil of a single phase dynamometer wattmeter has 4840 Ohm resistance. Voltage across the load is 220 V. With the potential coil connected on the load side, the meter indicates 100 W. Approximate percentage error due to wattmeter connection is 11%

Description : The two watt meters measurement the ratio of two meter readings is –(1-sqrt3):( 1+sqrt3) then the power factor is a) 1 b) 0.866 c) 0.707 d) 0

Last Answer : Ans: 0.707

Description : When troubleshooting electronic equipment, you should use a high impedance multimeter ________________. A. to prevent excess current flow through the meter that would damage it B. for AC measurements only ... being tested D. so as not to load down the circuit and obtain erroneous voltage readings

Last Answer : Answer: D

Description : Total instantaneous power supplied by a 3-phase ac supply to a balanced R-L load is

Last Answer : Total instantaneous power supplied by a 3-phase ac supply to a balanced R-L load is constant

Description : A alternator is delivering power to a balanced load at unit power factor. The phase angle between the line voltage and the line current is? (A) 90° (B) 60° (C) 30° (D) 0° 

Last Answer : A alternator is delivering power to a balanced load at unit power factor. The phase angle between the line voltage and the line current is 30°

Description :  In dynamometer type of wattmeter, which of the coil is split up into two parts?

Last Answer :  In dynamometer type of wattmeter, which of the coil is split up into two parts?  current coil

Description : The pressure coil of a dynamometer type wattmeter is  A) Highly inductive B) Highly resistive C) Purely resistive D) Purely inductive

Last Answer : highly resistive

Description : A wattmeter is connected as shown in the figure. The wattmeter reads 

Last Answer : A wattmeter is connected as shown in the figure. The wattmeter reads Power consumed by Z2

Description : Poynting vector wattmeter is based on   (A) Seebeck effect (B) Ferranti effect (C) Induction effect (D) Hall effect

Last Answer : Poynting vector wattmeter is based on Induction effect 

Description : The torque produced in wattmeter is proportional to

Last Answer : A

Last Answer : Wattmeter cannot be designed on the principle of moving iron instrument.

Last Answer : The pressure coil of a wattmeter should be connected on the supply side of the current coil when load impedance is high.

Last Answer : An induction wattmeter can be used for A.C. 

Last Answer : A dynamometer wattmeter can be used for both D.C. and A.C.

Description : In a balanced 3 -phase 200 V circuit, the line current is 115.5 A. When the power is measured by two wattmeter method, one of the wattmeters reads 20 kW and the other one reads zero. What is the power factor of the load ?

Last Answer : In a balanced 3 -phase 200 V circuit, the line current is 115.5 A. When the power is measured by two wattmeter method, one of the wattmeters reads 20 kW and the other one reads zero. What is the power factor of the load ?  0.5

Description : Two wattmeters connected to measure the power input to a balanced three-phase circuit indicate 4.5 KW and 3 KW respectively. Find the power factor of the circuit. A. 0.7 B. 0.8 C. 0.95 D. 0 

Last Answer : Two wattmeters connected to measure the power input to a balanced three-phase circuit indicate 4.5 KW and 3 KW respectively. Find the power factor of the circuit.  0.95

Description : The power delivered to a 3-phase load can be measured by the use of two wattmeters only when the  (a) load is unbalanced (b) load is balanced (c) three phase load is connected to the source through three wires (d) three phase load is connected to the source through four wires

Last Answer : The power delivered to a 3-phase load can be measured by the use of two wattmeters only when the three phase load is connected to the source through three wires 

Last Answer : The power factor of a single phase load can be calculated if the instruments available are three ammeters or three voltmeters.

Description : The instrument for measurement of flow/ velocity is________. A. Bimetallic. C) Turbine meter. B. Manometer. D) Wattmeter

Last Answer : Turbine meter

Description : Which of the following statements concerning monitoring techniques in the intensive care unit are true? A. Pulmonary artery and pulmonary capillary wedge pressure readings should be made ... clinical conditions not associated with tissue hypoxia, including liver disease and hypermetabolic states.

Last Answer : Answer: BD DISCUSSION: Many different monitoring techniques may be used to assess the adequacy of therapy for shock. The pulmonary artery catheter can provide important hemodynamic and oxygen ... also be seen with liver disease, toxin ingestion, and hypermetabolic states not associated with shock

Description : According to the classification of hypertension diagnosed in the older adult, hypertension that can be attributed to an underlying cause is termed a) secondary. Secondary hypertension may be caused by a tumor of ... mm Hg and the diastolic measurement is normal or near normal (less than 90 mm Hg).

Last Answer : a) secondary. Secondary hypertension may be caused by a tumor of the adrenal gland (e.g., pheochromacytoma).

Last Answer : The power of a n-phase circuit can be measured by using a minimum of (n - 1) wattmeter elements

Description : The true power indicated by a wattmeter depends on the current flow through the load, the magnitude of the potential across the load, and the _____________. A. power factor of the load B. angle of coil displacement C. inertia of the movable coil D. high resistance from the load

Last Answer : Answer: A

Description : Which of the following meters uses a shunt connected in series with the load, but parallel with the meter movement? A. voltmeter B. power factor meter C. wattmeter D. ammeter

Last Answer : Answer: D

Description : The true power indicated by the pointer movement of a wattmeter depends on the current flow through the load, the magnitude of the potential across the load, and the ____________. A. power factor of the ... B. angle of coil displacement C. inertia of the movable coil D. high resistance from the load

Last Answer : Answer: A