An AC supply of 230 V is applied to a half-wave rectifier circuit through a transformer having primary to secondary turn’s ratio 12:1. The peak inverse voltage is A) 8.62 V B) 12 V C) 19.17 V D) 27.11 V 

1 Answer

Answer :

 An AC supply of 230 V is applied to a half-wave rectifier circuit through a transformer having primary to secondary turn’s ratio 12:1. The peak inverse voltage is A) 8.62 V B) 12 V C) 19.17 V D) 27.11 V 

Related questions

Description : In a half-wave rectifier, if an a.c supply is 60 Hz. Then what is the a.c ripple at output? (A) 30 Hz (B) 60 Hz (C) 20 Hz (D) 15 Hz

Last Answer : In a half-wave rectifier, if an a.c supply is 60 Hz. Then what is the a.c ripple at output? (A) 30 Hz (B) 60 Hz (C) 20 Hz (D) 15 Hz

Description : Why does a transformer only work with an AC supply?

Last Answer : The transformer work depends on the induction as main principle ,for that AC is the right means

Description : operation of half wave rectifier type AC Voltmeter.

Last Answer :  Half-wave Rectifier Voltmeter The d'Arsonval meter movement only responds to the average or dc value of the current through the moving coil. In order to measure alternating ... ) input voltage signal alternating signal needs to be rectified first by using diode rectifier to produce 

Last Answer : Rectifier is use in power supply to convert Alternating current (AC) to Direct Current (DC) .

Last Answer : NO IT ONLY CONVERT FROM AC TO DC BECAUSE DIODE WHICH ARE USED IN IT, ARE UNIDIRECTIONAL.

Last Answer : IT CHANGES NEGATIVE CYCLE IN TO POSITIVE CYCLE FROM AC CURRENT.

Description : An AC supply of 230 V is applied to half wave rectifier circuit. A transformer turns ratio is 20 : 1. Find i) Output DC voltage (ii) Peak Inverse Voltage (PIV)

Last Answer : Solution:

Description : What will happen if the primary of a transformer is connected to D.C. supply?  (A) Transformer will operate with low efficiency (B) Transformer will operate with high efficiency (C) No effect (D) Transformer may start to smoke and burn 

Last Answer : What will happen if the primary of a transformer is connected to D.C. supply?  (A) Transformer will operate with low efficiency (B) Transformer will operate with high efficiency (C) No effect (D) Transformer may start to smoke and burn 

Description : Total instantaneous power supplied by a 3-phase ac supply to a balanced R-L load is

Last Answer : Total instantaneous power supplied by a 3-phase ac supply to a balanced R-L load is constant

Description : Consider a circuit with three parallel branches connected across a DC supply. What is the ratio of the branch currents I1 : I2 : I3 if the branch resistances are in the ratio of 2 : 3 : 4 respectively? A) 2 : 3 : 4 B) 6 : 4 : 3 C) 4 : 3 : 2 D) None of these

Last Answer : Consider a circuit with three parallel branches connected across a DC supply. What is the ratio of the branch currents I1 : I2 : I3 if the branch resistances are in the ratio of 2 : 3 : 4 respectively? A) 2 : 3 : 4 B) 6 : 4 : 3 C) 4 : 3 : 2 D) None of these

Last Answer : If the supply frequency to the transformer is increased, the iron loss will increase.

Description : In a step-down transformer, there is a change of 15 A in the load current. This results in change of supply current of?

Last Answer : In a step-down transformer, there is a change of 15 A in the load current. This results in change of supply current of less than 15A.

Last Answer : If a D.C. series motor is operated on A.C. supply, it will spark excessively, have poor efficiency, have poor power factor.

Description : Explain full wave bridged rectifier with the help of circuit diagram and input output waveform.

Last Answer : 1. In positive half cycle (0 to Π): The end A of the secondary winding becomes positive and end B negative. This makes diode D1 and D4 forward biased while diode D2 and D3 are reverse biased. These two diodes will ... D2 and D3 when it is conducting is as follows.  B - D2 - RL - D3 - A 

Description : Explain working of static AC circuit breaker. 

Last Answer : Static AC Circuit breaker: The circuit configuration of static AC circuit breaker using SCR is shown in the figure. When switch S' is closed, the SCRs T1 and T2 are fired in positive ... non-availability of gate current. Thus the maximum time delay for breaking the circuit is one half-cycle.

Description : Explain working of AC circuit breaker using SCR with circuit diagram.

Last Answer : AC Circuit Breaker:  The circuit configuration of static AC circuit breaker using SCR is shown in the figure. When switch S' is closed, the SCRs T1 and T2 are fired in positive ... to non-availability of gate current. Thus the maximum time delay for breaking the circuit is one half-cycle.

Description : An unshielded moving iron voltmeter is used to measure the voltage in an AC circuit. The stray DC magnetic field having a component along the axis will be  (1) unaffected (2) decreased (3) increased (4) either decreased or increased depending on the direction of the DC field

Last Answer : An unshielded moving iron voltmeter is used to measure the voltage in an AC circuit. The stray DC magnetic field having a component along the axis will be either decreased or increased depending on the direction of the DC field

Description : A parallel AC. circuit in resonance will?

Last Answer : A parallel AC. circuit in resonance will have a high impedance.

Description : In an AC. circuit, a low value of kVAR compared with kW indicates?

Last Answer : In an AC. circuit, a low value of kVAR compared with kW indicates high power factor.

Description : Can you apply Thevenin's theorem in an AC circuit?

Last Answer : It  can  be  applied  to  AC  circuits

Description : What is the purpose of a capacitor in an AC circuit?

Last Answer : Every AC supply is not ideal AC it contains DC component so to provide restriction to DC component in supply we have to use Capacitor

Description : To measure an A. C. voltage by using an A.C. potentiometer, it is desirable that the supply for the potentiometer in taken?

Last Answer : To measure an A. C. voltage by using an A.C. potentiometer, it is desirable that the supply for the potentiometer in taken from the same source as the unknown voltage.

Description : Can transformer convert AC to DC?

Last Answer : No, Transformer cannot convert AC to DC.

Description : List out advantages and disadvantages of bridge rectifier.

Last Answer : Advantages :  1. Bridge rectifier can be used in applications allowing floating output terminals i.e. not output terminal is grounded.  2. The need of center-tapped transformer is eliminated.  ... The value of the diodes used should be precise , else there will be an error in rectification

Last Answer : Rectifier is a device which convert AC to DC.

Description : The input of an A.C. circuit having power factor of 0.8 lagging is 40 kVA The power drawn by the circuit is?

Last Answer : The input of an A.C. circuit having power factor of 0.8 lagging is 40 kVA The power drawn by the circuit is 32 kW.

Description : Equivalent circuit of transformer

Last Answer : Equivalent Circuit Diagram of Transformer Referred to Primary: V1 -Primary Input voltage I1 - Input Current I0- Exciting current/ No load current Im- Magnetizing component ... equivalent of secondary terminal voltage ZL- Load impedance ZL ′- Primary equivalent of load impedance

Last Answer : The short circuit in any winding of the transformer is the result of impulse voltage.

Description : During open circuit test of a transformer?

Last Answer : During open circuit test of a transformer primary is supplied rated voltage.

Last Answer : Primary side is low voltage side and secondary side is high voltage side.

Last Answer : In short circuit test of transformer the low voltage side is short circuited . On high voltage side the voltmeter is connected in parallel and ammeter in series and also a wattmeter is ... circuit test is done for determining impedance and losses. In this test iron losses is neglected.

Description : In an A.C. circuit power is dissipated in?

Last Answer : In an A.C. circuit power is dissipated in resistance only.

Description : The apparent power drawn by an A.C. circuit is 10 kVA and active power is 8 kW. The reactive power in the circuit is?

Last Answer : The apparent power drawn by an A.C. circuit is 10 kVA and active power is 8 kW. The reactive power in the circuit is 6 kVAR.

Description : Pure inductive circuit takes power from the A.C. line when?

Last Answer : It takes power when voltage decreases and current increases.

Description : In any A.C. circuit always?

Last Answer : In any A.C. circuit always apparent power is more than actual power.

Description : All the rules and laws of D.C. circuit also apply to A.C. circuit containing?

Last Answer : All the rules and laws of D.C. circuit also apply to A.C. circuit containing resistance only.

Description : A 230 V/460 V single-phase transformer operating at 20 A and unity power factor has primary referred resistance of 0.2 Ω and reactance of 0.5 Ω. The approximate primary induced emf is (A) 216 V (B) 226 V (C) 234 V (D) 236 V

Last Answer : A 230 V/460 V single-phase transformer operating at 20 A and unity power factor has primary referred resistance of 0.2 Ω and reactance of 0.5 Ω. The approximate primary induced emf is 226 V

Description : The voltage of the single phase supply to residential consumers is (a) 110 V (b) 210 V (c) 230 V (d) 400 V

Last Answer : (c) 230 V

Last Answer : Igbt alone cant convert dc to ac. igbt half bridge or full bridge or three phase topology could be used to convert dc to ac. also igbt gates should be driven by microcontroller or pwm/spwm gate driving signals ... e4(-) and g4 c2e1 and c4e3 pins are AC output pins. its name is igbt inverter.

Last Answer : The stator of phase shifting transformer for use in conjunction with an A.C. potentiometer usually has a two-phase winding.

Description : Define PIV, TUF, ripple factor, efficiency of rectifier.

Last Answer : PIV: Peak Inverse Voltage (PIV) is defined as the maximum negative voltage which appears across non-conducting reverse biased diode. TUF : Transformer Utilization Factor (TUF) is defined as the ratio of DC output ... Efficiency of rectifier: η = DC output power/ AC input power = PLdc / Pac

Description : Single-phase mid-point controlled rectifier with RL load

Last Answer : Single-phase mid-point controlled rectifier with RL load : The circuit configuration of single-phase midpoint controlled rectifier is shown in the figure. During positive half-cycle of ... some part of next positive half-cycle of voltage with reversed polarity can appear across load.

Description : Single-phase Midpoint controlled rectifier with Resistive load

Last Answer : Single-phase Midpoint controlled rectifier with Resistive load:  1) During positive half cycle of AC supply, a is positive with respect to b , this makes T1 forward biased and T2 is reverse ... voltage reverses the polarity and T2 is turned off. The operation is as shown in waveforms.

Description : need of rectifier and filter. 

Last Answer : Need of rectifier: Every electronics circuit needs a D.C. power source for its operation. The rectifier circuit is used to convert A.C. supply to unidirectional pulses .  Need of filter: A filter ... only the D.C. components to reach the load. So filter is used to provide ripple free output.

Description : When the firing angle a of a single-phase, fully controlled rectifier feeding constant direct current into a load is 30°, the displacement power factor of the rectifier is

Last Answer : When the firing angle a of a single-phase, fully controlled rectifier feeding constant direct current into a load is 30°, the displacement power factor of the rectifier is √3/2

Last Answer : The rectifier instrument is not free from frequency error.

Last Answer : The scale of a rectifier instrument is linear.