Write the relation between phase and line current, phase and line voltage for Star connection.

2 Answers

Answer :

In  a star connection, line current equals  quberoot  of  phase  current    and   line  voltage  equals  phase  voltage.

Answer :

Line voltage is equal to root three times of phase voltage and line and phase currents are equal in star connection

Related questions

Description : Compare star and Delta Connection.

Last Answer : Compare Star and Delta connected system:  Star connected system Delta connected system   In STAR connection, the starting or finishing ends (Similar ends) of three coils are connected together to form the ... VPH Line Current is √3 times of Phase Current. i.e. IL = √3 IPH

Description : What is the difference between line and phase current?

Last Answer : The currents flows through phase lines is called line voltage and currents flows from phase to neutral line is called phase current

Description : What is the difference between line and phase voltage?

Last Answer : Line voltage  is  voltage  between two  phases R &Y  (415 v)  while  phase  voltage  is  the  voltage  between  one  phase and  a neutral  B &  N   (240 v).

Description : What is the voltage in 3 phase line?

Last Answer : between 430 to 440 v

Description : What is difference between Star and Delta Connection?

Last Answer : Star is        1. Open ckt       2. At center point present  neutral   Delta is     1.   Closed ckt 2.      Neutral not present in this case 

Description : Explain MCB and ELCB with connection diagram supplying single phase load. 

Last Answer : OR OR Explanation: * MCB provides short circuit protection. * MCB provides overload protection * ELCB provides earth fault protection. * MCB is in series with ... occurs, the ELCB cuts off the power within the time of 0.1 sec. automatically to protect the personnel. 

Description : What is a three phase connection?

Last Answer : RYB, 440 volt/phase

Description : If an unsymmetrical line to ground fault occurs at the secondary terminals of a delta/star, ungrounded transformer, then  (A) zero sequence currents are present on both sides of the transformer  (B) ... side  (D) zero sequence currents are present on the primary side but not on the secondary side

Last Answer : If an unsymmetrical line to ground fault occurs at the secondary terminals of a delta/star, ungrounded transformer, then zero sequence currents are absent on both sides of the transformer 

Description : A 3-phase voltage source inverter operates in 180° conduction mode with a star connected resistive load. If input dc voltage is 100 V, then the peak to peak output line voltage is :

Last Answer : A 3-phase voltage source inverter operates in 180° conduction mode with a star connected resistive load. If input dc voltage is 100 V, then the peak to peak output line voltage is : 200 V

Description : Which of the following connection of transformers will give highest value of secondary voltage ? (A) Delta primary delta secondary (B) Delta primary star secondary (C) Star primary star secondary (D) Star primary delta secondary

Last Answer : Which of the following connection of transformers will give highest value of secondary voltage ? (A) Delta primary delta secondary (B) Delta primary star secondary (C) Star primary star secondary (D) Star primary delta secondary

Description : Define: 1) voltage ratio, 2) current ratio, 3) transformation ratio of transformer.

Last Answer : 1) Voltage ratio: The voltages in primary and secondary winding is proportional to number of turns in primary and secondary respectively. So, the voltage ratio is same as transformation ratio. V2/V1 = N2 ... as transformation ratio of transformer. It is denoted by K. K = N2/N1

Description : For 11kV line the inductance per km per phase will be of the order of:  (A) 1 H (B) 0.1 H (C) 1 mH (D) 0.1 mH

Last Answer : For 11kV line the inductance per km per phase will be of the order of: 1 mH

Last Answer : Reactance relay is preferred for phase fault on short transmission line.

Last Answer : Impedance relays are used for phase faults on long line.

Description : The line current in a balanced delta system is 30 A. The load current is (A) 30√3 A (B) 30/√3 A (C) 10 A (D) 30/√2 A

Last Answer : The line current in a balanced delta system is 30 A. The load current is 30/√3 A

Description : Is the power line voltage available in our homes a dc or an ac voltage?

Last Answer : The power line voltage available in our homes is AC. Mobile dwellings are the most commonly DC-supplied homes and even then they tend to include AC supply for heavier loads.

Description : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole)  (A) has q -axis current only (B) has d -axis current only (C) has both d and q axis currents (D) cannot be divided between q and d axis currents

Last Answer : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole) has d -axis current only

Description : A single core cable is designed to work for a single phase system with a peak voltage of 220 kV. The maximum permissible stress in the dielectric is not to exceed 20 kV/mm. For economical size, the overall core diameter of the cable is (A) 28.2 mm (B) 26.4 mm (C) 24.4 mm (D) 22.0 mm

Last Answer : A single core cable is designed to work for a single phase system with a peak voltage of 220 kV. The maximum permissible stress in the dielectric is not to exceed 20 kV/mm. For economical size, the overall core diameter of the cable is 22.0 mm

Description : In an alternator at lagging power factor the generated voltage per phase as compared to that at unity power factor?

Last Answer : In an alternator, at lagging power factor the generated voltage per phase as compared to that at unity power factor must be more than terminal voltage.

Description : Why the read of 3 phase voltage is 440?

Last Answer : The  read  of  a  phase  voltage  should be approximatly  240v. This  is  because  line  voltage  equals  to quberoot of  phase  voltage.

Description : Explain the principle of ON-OFF control and phase control of AC voltage controller with suitable circuit and waveforms.

Last Answer : The integral cycle control (on-off control) and phase angle control are the two types of AC voltage controller. The principle of ON-OFF control: The on-off control is also called an integral cycle ... control. In phase control, the switch is on for some period of each cycle.  

Description : Define α & β and derive the relation between (α) &) (β) of transistor.

Last Answer : α : The ratio of output collector current IC to input emitter current IE in the CB configuration is called current gain alpha (α).  β : The ratio of output collector current IC to the input base current IB in the CE configuration is ... ( 1/β) + 1  hence 1/ α = (1+β )/ β  Therefore, α = β /(1+β)

Description : Analyze the effect of supply voltage on performance of LED as regards current, Lumen output, efficacy and life. 

Last Answer : 1) Effect on Current:- In LED current depends upon supply voltage, if voltage get changes then current also change but this change in current will be control by resistors which are connected in series.  2) ...   4) Effect on Life:- If supply voltage is not stable then life of LED get reduced. 

Description : With the help of N-channel JFET describe the effect of input voltage VGS on output current ID.

Last Answer : Working of N channel FET: * When a voltage is applied between the drain and source with a DC supply (VDD), the electrons flows from source to drain through narrow channel ... where the channel gets completely blocked and the drain current becomes zero is called pinch- off voltage. 

Description : Define: i) Input Offset Voltage ii) Input offset Current iii) Input Bias Current iv) Output offset voltage

Last Answer : Definition of parameters of OPAMP is follows:  i) Input Offset Voltage: Input offset voltage is defined as the voltage that must be applied between the two input terminals of an OPAMP to null or ... to ground) and output voltage is obtained non zero such voltage is output offset voltage of opamp.

Description : A linear network has a current input 4cos(ω t + 20º)A and a voltage output 10 cos(ωt +110º) V. Determine the associated impedance.

Last Answer : Solution

Description : What kills, current or voltage?

Last Answer : Current would kill. You can actually have thousands of bolts going through you and not even know it. Yes you probably know already voltage is current times resistance. Since your body is a resistor it would take just a small amount of current to create a very high voltage

Description : Why inductor current lags inductor voltage ?

Last Answer : Inductor is a wire wounding structure having a core material it induces emf which is opposite to the voltage supply and proportional to rate of change of current so current lags the voltage in inductor

Description : Explain lagging quantity and leading quantity, explain this concept with voltage and current waveform

Last Answer : When two alternating quantities attain their respective zero or peak values simultaneously, the quantities are said to be in-phase quantities. When the quantities do not attain their respective zero or ... current is leading the voltage or the voltage is said to be lagging behind the current.

Description : A zener voltage regulator has load requirements of 12 V and 2 A. The zener diode minimum current requirement is 0.2 A. The minimum voltage at input is 24 V. What is the required value of series resistance with source? A) 5.45 Ω B) 6 Ω C) 7.2 Ω D) 6.38 Ω  

Last Answer : A zener voltage regulator has load requirements of 12 V and 2 A. The zener diode minimum current requirement is 0.2 A. The minimum voltage at input is 24 V. What is the required value of series resistance with source? A) 5.45 Ω B) 6 Ω C) 7.2 Ω D) 6.38 Ω  

Description : Step-down transformer converts high voltage and low current into:  (A) How voltage and high current (B) High voltage and low current (C) Low voltage and high current (D) None of the above

Last Answer : Step-down transformer converts high voltage and low current into: Low voltage and high current

Description : Which of the following is the least expensive protection for over current in low voltage system?  (A) Rewireable fuse (B) Isolator (C) Oil Circuit breaker (D) Air break circuit breaker

Last Answer : Which of the following is the least expensive protection for over current in low voltage system?  (A) Rewireable fuse (B) Isolator (C) Oil Circuit breaker (D) Air break circuit breaker

Description : A current controlled voltage source is equivalent to :  (A) series voltage feed -back amplifier (B) shunt current feed -back amplifier (C) shunt voltage feed -back amplifier (D) series current feed -back amplifier

Last Answer : A current controlled voltage source is equivalent to : shunt voltage feed -back amplifier

Description : Which of the following theorems enables a number of voltage (or current) source to be combined directly into a single voltage (or current) source. (1) compensation theorem (2) reciprocity theorem (3) superposition theorem (4) Millman's theorem

Last Answer : Which of the following theorems enables a number of voltage (or current) source to be combined directly into a single voltage (or current) source. (1) compensation theorem (2) reciprocity theorem (3) superposition theorem (4) Millman's theorem

Description : A network that consists of at least a voltage source or current source is called A) Active network B) Ideal network C) Sourced network D) Outsourced network

Last Answer : A network that consists of at least a voltage source or current source is called Active network

Description : The internal resistances of an ideal current source, and an ideal voltage source are, respectively, (A) 0, ∞ (B) ∞, ∞ (C) ∞, 0 (D) 0,0

Last Answer : The internal resistances of an ideal current source, and an ideal voltage source are, respectively, ∞, 0

Description : A network is said to be under resonance when the voltage and the current at the network input terminals are (A) in phase (B) out of phase (C) in phase quadrature (D) in phase, and have equal magnitudes

Last Answer : A network is said to be under resonance when the voltage and the current at the network input terminals are in phase

Last Answer : In order that current should flow without causing excessive heating or voltage drop, the relay contacts should have low contact resistance, be clean and smooth, be of sufficient size and proper shape.

Description : Why does increase in current mean a decrease in voltage?

Last Answer : This is because current flows from high potential to low potential to bring the two diffrent potential to unity , thus  a reduced potential (voltage)

Description : About trnsformer

Last Answer : Acc to Ohms law V=IR but it is only applicable when our resistance R is constant, as in case of transformer we take impedence which is equivalent to resistance is not constant it varies with system parameters that why Ohms law not applicable in case of transformer

Description : Electrical shock happens for voltage/current?

Last Answer : The severity ofelectric shockdepends on thecurrentflowing through the body, which is a function of the electromotive force (E) involts, and the contact resistance (R) in ohms.

Description : When a voltage of one volt is applied, a circuit allows one micro ampere current to flow through it. The conductance of the circuit is?

Last Answer : If v = 1 volt and i = 1 micro amp, i= 10^(-6)   So R = V/I,  R= 1/10^(-6) , R= 10^6  And now Conductance G = 1/R  So G = 10^(-6) mho..... Answer

Description : Explain with the neat circuit diagram only the scott connection scheme for conversion of three phase supply to two phase supply. Name one application of the same.

Last Answer : Three-phase to Two-phase Transformation (Scott Connection of Transformers): Working: i) Scott connection can be used for three-phase to two-phase conversion using two single-phase transformers ... a 3-phase system with a two-phase system with the flow of power in either direction. 

Description : Which of the following 3-phase connection of a transformer causes interference with the neighbouring communication lines:  (A) Delta-Star (B) Star-Delta (C) Delta-Delta (D) Star-Star

Last Answer : Which of the following 3-phase connection of a transformer causes interference with the neighbouring communication lines: Star-Star

Description : Explain construction and working principle of single phase transformer.

Last Answer : A single phase transformers is an electrical device that accepts single-phase AC power and outputs single-phase AC. PRINCIPLE... The single-phase transformer works on the principle of ... and secondary windings. Thin steel laminations shall be employed to prevent power losses from the core.

Description : State any four applications of three phase circuits.

Last Answer : The application of three phase circuits are 1. Three phase circuit is used for power transmission over long distances. 2. Three phase circuit can produce rotating magnetic field 3. Three phase ... three phase Motors and Transformers. 4. Three phase circuit is used for power converters circuits.

Description : Define phase sequence of three phase supply with waveforms. What is normal phase sequence? Which 3 standard colours are used to denote the phase sequence?

Last Answer : It  is  sunnosoidal  sequence.

Description : State advantages of three phase over single phase.

Last Answer : Advantages of 3-phase system over 1-phase system: -  1. More output: For the same size, output of poly-phase machines is always higher than single phase machines.  2. Smaller size: For ... are self- starting: The three phase ac motors are self starting, while single phase induction motor are not.

Description : Draw the structural diagram of GTO. Explain briefly the switching behavior of GTO with the help of appropriate voltage and current waveform.

Last Answer : Gate Turn Off Thyristor (GTO) Conventional Thyristor can be turned on with gate terminal but can not turn off from gate terminal. But in case of Gate Turn Off Thyristor (GTO), we can turn it on and off ... subdivided as storage period (Ts), fall period (Tp) and tail period (Tt).

Description : UPS- How to give Connection?

Last Answer : Ans. Means Uninterrupted power supply. To give UPS connection, first normal supply is kept off. Then, loads of essential and non essential are to be segregated. Essential loads are to be brought under single point of control. Then, UPS can be connected.