Draw the power and control circuit diagram for forward — stop — Reverse type DOL starter for 3 phase induction motor.

1 Answer

Answer :

Draw the power and control circuit diagram for forward — stop — Reverse type DOL starter for 3 phase induction motor.

image image

Related questions

Description : Explain DOL starter used for 3 phase induction motor.

Last Answer : DOL Starter Used for 3 Phase Induction Motor: The direct online starter consist of overload relay (OLC), contactor, start-push button S1 (normally open), stop-push button S2 (normally ... The overload coil (OLC) protects the motor against overload and short circuit by opening the contact D.

Description : A 3-phase delta connected squirrel cage induction motor when started with a DOL starter has a starting torque of 600 NM. Its starting torque when star delta starter is used:

Last Answer : A 3-phase delta connected squirrel cage induction motor when started with a DOL starter has a starting torque of 600 NM. Its starting torque when star delta starter is used: 200 NM

Description : Describe the power and control circuit for automatic Star-Delta starter for 3-phase induction motor.

Last Answer : Power circuit: Control circuit: 

Description : Can you draw a DOL starter circuit?

Last Answer : Refer to DOL diagram in Dennis T Hall

Description : Draw power and control circuit for definite time-limit starter for slip-ring induction motor. Explain its working.

Last Answer : Definite Time-limit Starter for Slip-ring Induction Motor: This starter is used for automatic control of acceleration of slip-ring induction motor at the time of starting. In this starter, the ... each phase, shorting the rotor winding terminals and final acceleration of the motor takes place. 

Description : Develop a ladder diagram for Direct On Line (DOL) starter.

Last Answer : Direct On Line (DOL) starter

Description : A three-phase cage induction motor is started by direct-on-line (DOL) switching at the rated voltage. If the starting current drawn is 6 times the full load current, and the full load slip is 4%, then ratio of the ... load torque is approximately equal to (A) 0.24 (B) 1.44 (C) 2.40 (D) 6.00

Last Answer : A three-phase cage induction motor is started by direct-on-line (DOL) switching at the rated voltage. If the starting current drawn is 6 times the full load current, and the full load slip is 4%, then ratio of the starting developed torque to the full load torque is approximately equal to 1.44

Description : Develop power and control diagram for secondary frequency acceleration starter of slip ring induction motor. 

Last Answer : Power and Control Circuit diagram for secondary frequency acceleration starter of slip ring induction motor:

Description : Draw and explain star delta starter for 3 phase induction motor

Last Answer : Star Delta Starter for 3 Phase Induction Motor:  Diagram Explanation: The stator winding of the motor which is designed for delta operation is connected in star during starting ... which connects stator windings in delta connection. Now each stator phase gets full line voltage VL.

Description : The diagram shown in the illustration represents a _________. EL-0058 A. dual speed, 2-winding motor controller B. navigation running light circuit C. single phase, 2-motor selectable starter D. common fluorescent lighting circuit

Last Answer : Answer: B

Description : Develop the control circuit for star-delta starter used for starting a 3 ∅ induction motor.

Last Answer : Control Circuit for Star-Delta Starter: 1) Automatic Star-Delta Starter: OR 2) Semi- automatic Star-Delta Starter:

Description : If the three-phase motor, shown in the illustrated schematic diagram, is running in the forward direction, which of the following actions must occur before the motor will reverse rotation? EL-0011 A. Normally-closed ... 'L1' and 'L3' must be interchanged via the 'R' contacts. D. All of the above.

Last Answer : Answer: C

Description : Draw the power and control circuit for motors using autotransformer type starter.

Last Answer : Draw the power and control circuit for motors using autotransformer type starter.

Description : Draw power and control circuit for simple plugging of induction motor.

Last Answer : Fig. Power and control circuit for simple plugging of induction motor.

Description : Which of the following actions must be carried out before a voltage tester can be used to test the three line fuses to a three-phase motor? A. The fuses must be removed from the circuit. B. The ... disconnected and tagged. D. Nothing need be done as long as the motor is running under a light load.

Last Answer : Answer: B

Description : Low voltage releases as used in some shipboard motor starter and control equipment will have which of the following characteristics? A. They trip circuit contactors when the motor starts to overspeed. B. ... coil of the starter. D. They allow the motor to restart upon restoration of normal voltage.

Last Answer : Answer: D

Description : Consider the following statements: Star delta starter is used in 3-phase induction motor because it  1. Prevents heating of the motor winding  2. Ensures permissible minimum starting current  3. Is regulated by electricity ... and 4 are correct (c) 1, 3 and 4 are correct (d) 1 and 2 are correct 

Last Answer : Consider the following statements: Star delta starter is used in 3-phase induction motor because it  1. Prevents heating of the motor winding  2. Ensures permissible minimum starting current  3. Is regulated by ... and 4 are correct (c) 1, 3 and 4 are correct (d) 1 and 2 are correct 

Description : how can we reverse the direction of rotation of three phase induction motor ?

Last Answer : The direction of rotation of three phase induction motor can be reversed by plugging i.e by changing any two out of three phases of the supply to the stator of the Induction motor terminal.

Description : To reverse the direction of rotation of a three-phase AC induction motor, do one of the following: w) reverse any two of the three-phase connections x) change the frequency of the applied AC power y) operate the motor below the stall torque at very high slip z) none of the above

Last Answer : ANSWER: W -- REVERSE ANY TWO OF THE THREE-PHASE CONNECTIONS 

Description : Draw and explain the circuit diagram for measurement of single phase power using dynamometer type wattmeter. 

Last Answer : Circuit diagram for measurement of single phase power using dynamometer type wattmeter: Explanation: It consists of two stationary coils, called current coils and one moving coil, called voltage or ... i.e. power. The meter can be calibrated directly to indicate the power in watts. 

Description : Refering to the illustrated schematic diagram, which of the following statements is true when the motor is running in the forward direction? EL-0011 A. Normally-open contacts '4-5' are closed. B. Current ... switch. C. Normally-closed contacts 'R' are open. D. The blowout coils must be closed.

Last Answer : Answer: B

Description : Draw and explain power flow diagram of induction motor.

Last Answer : Power flow diagram of induction motor: 1) Energy flow diagram is a graphical representation of the different power flow paths in which the width of the arrows are proportional to quantity of ... rotor body and bearings. The remaining power then appears as net rotor output mechanical power.

Description : Draw the wiring diagram of fluorescent tube. Explain the working of choke and starter. 

Last Answer : Fluorescent lamp:- Operation:- When switch is ON current flows through the choke-filament no1- starter-filament no. 2- to neutral, At that time choke induces high voltage which is applied to ... at the time of starting. ii) Starter: To make and break the circuit to start the tube. 

Description : To check the three line fuses of a three-phase system consisting of a three-phase motor, you must _____________. A. place the starter in the 'stop' position B. make sure the motor is operating at full ... leads across the 'hot' ends of the fuses D. place the leads across the bottom ends of the fuses

Last Answer : Answer: A

Description : Explain the working of resistance split phase induction motor with a neat diagram.

Last Answer : Circuit diagram of resistance split single phase induction motor:   * Working of resistors split single phase induction motor: To make a single phase induction motor self-starting, we ... function is to automatically disconnected the starting winding from the supply Once motor is started. 

Description : Draw neat labeled diagram of single phase AC locomotive showing its various equipments of power circuit and give function of each equipment used in power circuit.

Last Answer : Functions of equipment: 1) circuit breaker: disconnects the locomotive equipment from the supply in the event of fault in the equipment / loco. 2) On load tap changer, used to control the ... 6) Traction motor: operates as per the required operating characteristics to take on the traction load.

Description : The variable resistance placed in the rotor circuit of a wound-rotor induction motor provides for __________. A. speed control B. frequency control C. voltage control D. use as a split-phase motor

Last Answer : Answer: A

Description : What is the Necessity of Starter of an Induction Motor?

Last Answer : Induction motors, when direct-switched, take five to seven times their full-load current and develop only 1.5 to 2.5 times their full-load torque. This initial excessive current is ... electrical equipment connected to the same lines. Hence, a starter is necessary to overcome this objection.

Description : What are the advantages of star-delta starter with induction motor?

Last Answer : The main advantage of using the star delta starter is reduction of current during the starting of the motor. Starting current is reduced to 3-4 times of current of Direct online starting Hence the starting current is reduced , the voltage drops during the starting of motor in systems are reduced

Description : Why star delta starter is preferred with induction motor?

Last Answer : Star delta starter is preferred with induction motor due to following reasons: Starting current is reduced 3-4 times of the direct current due to which voltage drops and hence it causes less ... caused. In addition, starting torque is increased and it prevents the damage of motor winding.

Description : What operational characteristics do the components labeled as 'S' and 'R' represent in the motor controller diagram shown in the illustration? EL-0080 A. Standard and Reverse directions B. Stop and Restart features C. Subnormal and Regular loading D. Start and Run functions

Last Answer : Answer: D

Description : What is the draw back of the resistance split-phase induction motor?

Last Answer : The starting winding has a relatively small number of turns of fine wire and its resistance is higher than that of the main winding. Therefore the current density is high and the winding heats up quickly. ... begins to smoke and may burn out unless the motor is protected by a built-in-thermal relay.

Description : Explain the construction of three phase induction motor with neat diagram.

Last Answer : Construction of Three-phase Induction Motor: There are two main parts of the three phase induction motor:  i) Stator which is the stationary part  ii) Rotor which is the rotating ... slip-rings. In this rotor also the slots are not exactly parallel to the shaft but slightly skewed.

Description : Draw the circuit diagram for:- i) Measurement of active power in 3-phase load circuit using two wattmeter. ii) Measurement of reactive power in 3-phase load circuit using one wattmeter.

Last Answer : (i) Measurement of active power in 3- phase load circuit using two- wattmeter: (ii) Measurement of reactive power in 3- phase load circuit using one wattmeter

Description : In a faceplate-type motor starter, the starting arm is held in the 'OFF' position by a/an _____________. A. cotter pin B. magnet C. electrical circuit D. strong spring

Last Answer : Answer: D

Description : The power input to the rotor of a 400V, 50 Hz 6 pole three phase induction motor is 20kW. The slip is 3%. The frequency of rotor currents is: (A) 1 Hz (B) 1.5 Hz (C) 2 Hz (D) 1 2 Hz

Last Answer : C

Description : If a three-phase induction motor is operated under a light load and it develops an open in one of its supply lines, the motor will _____________. A. continue to run, but will vibrate and have reduced ... speed up due to the reduced number of poles C. run cooler due to reduced current flow D. stop

Last Answer : Answer: A

Description : Which of the following problems will most likely occur if the starting winding of a split-phase induction motor failed to cutout once the motor was in continuous operation? A. The motor will overspeed. B. The ... reduced speed. C. A time delay will stop the motor. D. The winding will burn out.

Last Answer : Answer: D

Description : If a three-phase induction motor malfunctions and drops to a single-phase (one supply line open) ____________. A. the motor will continue to run if it is not heavily loaded B. more torque will be ... be able to be restarted D. the motor will immediately stop and can only be restarted at no load

Last Answer : Answer: A

Description : List out the methods of speed control of cage type 3-phase induction motor?

Last Answer : a) By changing supply frequency b) By changing the number of poles c) By operating two motors in cascade

Description : If a single-phase induction motor fails to start, the problem may be _____________. A. an open in the main winding B. a shorted shunt field C. a closed centrifugal switch D. low circuit frequency

Last Answer : Answer: A

Description : If a single-phase induction motor fails to start, the problem may be _____________. A. an open in the run winding B. a shorted shunt field C. a closed centrifugal switch D. low circuit frequency

Last Answer : Answer: A

Last Answer : If starting winding of a single-phase induction motor is left in the circuit, it will draw excessive current and overheat.

Description : If the contacts of a motor starter or controller fail to drop out when the 'stop' button is depressed the ____________. A. contacts are carrying excessive current B. contacts have become welded together C. shading coil is broken D. shading coil is loose

Last Answer : Answer: B

Description : Draw a circuit diagram of R.C. series circuit. Draw impedance triangle and power triangle for same circuit. 

Last Answer : Draw a circuit diagram of R.C. series circuit. Draw impedance triangle and power triangle for same circuit. 

Description : How do dual-motor dual capstan drives maintain a constant tape tension while operating in either a forward or reverse direction?

Last Answer : Each capstan is driven by its own motor. It maintains tape tension by slowing down one of the motors. When the tape motion is reversed, the opposite motor is slowed down.

Description : The equilibrium constant for the gas phase reactio A + B = C + D is 10-3. The rate of the forward reaction is 10-11 cubic centimeters per molecule per second. What is the rate constant of ... second y) 10-10 cubic centimeters per molecule per second z) 10-14 cubic centimeters per molecule per second

Last Answer : ANSWER: Z -- 10-14 CUBIC CENTIMETERS PER MOLECULE PER SECOND 

Description : The type of single-phase induction motor having the highest power factor at full load is (A) shaded pole type (B) split-phase type (C) capacitor-start type (D) capacitor-run type

Last Answer : The type of single-phase induction motor having the highest power factor at full load is capacitor-run type

Description : Reversing any two of the three rotor leads on a wound-rotor induction motor will _____________. A. increase motor performance B. decrease motor performance C. reverse the motor rotation D. have no effect on the direction of rotation or motor performance

Last Answer : Answer: D