Please Log in or Register for more.

Difference between STATCOM and SVC?

1.4k views

2 Answers

Answer :

 
✔️✔️Best answer
Difference between STATCOM and SVC:

STATCOM 
SVC
Faster
Slower than STATCOM
Cost is high
Cost is low
Higher losses
Less losses
Better characteristics
Not good as STATCOM
Constant current characteristics
Capacitive reactive current drops linearly
Interfaced with real power sources like battery, Fuel cell or SMES. Not Interfaced with real power sources like battery, Fuel cell or SMES.
Smaller in size
Larger in size
Controllable voltage source
Dynamically controlled reactance


Like 0 like

Answer :


STATCOM vs SVC

image

Like 0 like

Please log in or register to answer this question.

Related Questions


Static Synchronous Compensator (STATCOM)
Last Answer : Static Synchronous Compensator (STATCOM)  STATCOM stands for Static Synchronous Compensator or Condenser. It may be a source of reactive power or sink of reactive AC power. It can ... and Controllers etc. STATCOM have symmetric lead-lag capability. STATCOM have no moving part.

Show More

189 views 1 answer







Improvement of transient stability using SVC
Last Answer : Improvement of transient stability using SVC The static VAR compensator (SVC) is a shunt connected FACTS device. SVC have two modes one is inductive ... ;transmittable power. Transient stability improvement can be estimated using equal area criterion.

Show More

244 views 1 answer







What is static var compensator ?
Last Answer : Static VAR Compensator (SVC)  SVC are use for regulating transmission voltage and for improving power quality of industrial load. SVC is made from one or more banks ... system. Static VAR Compensator is more reliable than dynamic compensation scheme like synchronous condenser.

Show More

327 views 1 answer







SVC obstruction?
Last Answer : DefinitionSVC obstruction is a narrowing or blockage of the superior vena cava -- the second largest vein in the human body. The superior vena cava moves blood from the upper half ... vena cava obstruction can also be caused by noncancerous conditions that cause scarring. These conditi

Show More

0 views 1 answer







Which of the following General Insurance Company has entered into agreement with Shamrao Vithal Co-operative (SVC) Bank for bancassurance business? A) Reliance General Insurance Co. Ltd. B) L&T General Insurance ... D) Future Generali India Insurance Co. Ltd. E) Tata AIG General Insurance Co. Ltd.
Last Answer : C) HDFC ERGO General Insurance Co. Ltd. Explanation: HDFC ERGO General Insurance Company and Shamrao Vithal Co-operative (SVC) Bank announced their bancassurance agency partnership to provide ... introducing innovative non-life insurance products with SVC Bank s customer base across various states.

Show More

1 view 1 answer







In Frame Relay, when. ______ is selected, it requires establishing andterminatingphases A) a PVC B) an SVC C) either (a) or (b) D) neither (a) nor (b)
Last Answer : an SVC

Show More

2 views 1 answer







In Frame Relay, when a _____ is selected, the correspondingtable entry is recorded for all switches by the administrator A) PVC B) SVC C) either (a) or (b) D) neither (a) nor (b)
Last Answer : PVC

Show More

5 views 1 answer







VCIs in Frame Relay arecalled ______. A) PVC B) SVC C) DLCIs D) none of the above
Last Answer : DLCIs

Show More

5 views 1 answer







I'm Msc student in electrical engineering  and my project in control of the UPFC can you help me ?
Last Answer : UPFC means unified power flow controller. The control on UPFC is based on vector control approch proposed by Schauder & Mehta for Advanced static VAR compensators in 1991

Show More

171 views 1 answer







A homo-polar HVDC link consists of (A) single-conductor with positive polarity (B) two conductors with one positive and another negative polarity (C ) two conductors having the same polarity with a ground return (D) single conductor with negative polarity and ground as positive polarity 
Last Answer : two or more conductore having same  polarity,usually nagative . and ground return  ex: 1st conductore drain Id1 and 2nd  drain Id2 than the return will be (Id1+Id2)

Show More

164 views 1 answer







A static VAR compensator is a (A) series connected thyristor based controller (B) shunt connected thyristor based controller (C) energy storage device (D) combined series–shunt connected controller 
Last Answer : Shunt connected thyristor based controller

Show More

183 views 1 answer







The Interline Power Flow Controller in a transmission system (A) injects voltage by static series converters (B) injects current by static shunt converters (C) injects voltage and current ... series and shunt converters (D) provides real and reactive power compensation by static shunt compensator 

Show More

75 views 0 answers







What is the purpose of a capacitor in an AC circuit?
Last Answer : Every AC supply is not ideal AC it contains DC component so to provide restriction to DC component in supply we have to use Capacitor

Show More

185 views 1 answer







How does a capacitor improve power factor?
Last Answer : Every circuit are usually more inductive than capacitive.it means that the current lags by voltage at small angle.hence we have to compensate this situation so we use Capacitor then this lag is compensate ... angle becomes low and the value of cos(phase angle) is increase and hence power also max.

Show More

164 views 1 answer







What is the formula for reactive power?
Last Answer : The formula for reactive power is, Reactive power = VI sin (phi) The unit of reactive power is VAR ( Volt ampere reactive). The reactive power is denoted by 'Q'. The formula for real power is, Real power = VI cos (phi) The unit of real power is watts. The real power is denoted by 'P'.

Show More

224 views 2 answers







reactive power is greater in load side compare to generator what will happen?
Last Answer : VI*sin()

Show More

163 views 2 answers







Objectives of shunt compensation
Last Answer : Objectives of shunt compensation Shunt compensation is use to improve power factor. In Shunt compensation FACTS are connected in parallel with power system and works like a controllable current ... voltage control and damp power oscillation. Examples of shunt compensation is STATCOM and SVC.

Show More

2.0k views 1 answer







Thyristor Switched Capacitor (TSC)
Last Answer : Thyristor Switched Capacitor (TSC)  TSC is a static compensator. TSC is use for compensating reactive power. Compensation is required for voltage regulation, increasing stability, ... compensating device like TCS phase angle between voltage and current can be maintain.

Show More

202 views 1 answer







Saturated Reactor (SR)
Last Answer : Saturated Reactor (SR) Saturated reactor is use for controlling reactive power. It consists of reactor and shunt capacitor bank. It is like a magnetic ... called amplification factor. The disadvantage of saturated reactor is its slow response.

Show More

153 views 1 answer







What is Synchronous condenser?
Last Answer : Synchronous condenser Big advantage of synchronous condenser is their large temporary overload capability and good harmonics performance. Synchronous condenser is ... ;voltage levels. Synchronous condenser have slow speed of response.

Show More

106 views 1 answer







what is TCSC?
Last Answer : Thyristor Controlled Series Capacitor (TCSC)

Show More

223 views 1 answer







what is UPFC?
Last Answer : UPFC stands for unified power flow controller.  It's used for real time control & dynamic compensation of ac transmission system.

Show More

855 views 2 answers






Show More⇦ PreviousNext ⇨