Name the material used for :- (i) Moving coil (ii) Permanent magnet in PMMC instrument.

1 Answer

Answer :

(i) Material used for Moving coil: Copper, Aluminum( some times) 

(ii) Permanent magnets are made of special alloys such as : 

 Aluminum-Nickel-Cobalt (Alnicos) 

 Strontium-Iron 

 Neodymium-Iron-Boron 

 Samarium-Cobalt.

Related questions

Last Answer : A moving-coil permanent-magnet instrument can be used as flux-meter by eliminating the control springs.

Last Answer : A moving-coil permanent-magnet instrument can be used as ammeter by using a low resistance shunt.

Description : Permanent magnet moving coil instruments are used for

Last Answer : PMME are mostly used for measuring voltage and current.

Description : State the material used for moving coil and former for PMMC instruments. 

Last Answer : Material Used for Moving Coil and Former for PMMC Instruments:  Material used for moving coil: Copper  Material used for Former: Aluminium

Description : When the voltage across a battery is measured using a D.C potentiometer, the reading shows 1.08 V. But when the same voltage is measured using a Permanent Magnet Moving Coil (PMMC) voltmeter, the voltmeter reading shows 0.99 ... resistance of the battery, in Ohm , is (A) 150 (B) 100 (C) 50 (D) 200

Last Answer : When the voltage across a battery is measured using a D.C potentiometer, the reading shows 1.08 V. But when the same voltage is measured using a Permanent Magnet Moving Coil (PMMC) voltmeter, ... resistance of the voltmeter is 1100 Ohm , the internal resistance of the battery, in Ohm , is 100

Description : A PMMC instrument has FSD of 100 μA and a coil resistance of 1 kΩ. To convert the instrument into an ammeter with full scale deflection of 100 mA, the required shunt resistance is (A) 1 Ω (B) 1.001 Ω (C) 0.5 Ω (D) 10 Ω

Last Answer : A PMMC instrument has FSD of 100 μA and a coil resistance of 1 kΩ. To convert the instrument into an ammeter with full scale deflection of 100 mA, the required shunt resistance is 1.001 Ω

Description : Compare variable reluctance and permanent magnet motors.

Last Answer : Variable reluctance Motor  Permanent magnet motors   The rotor is not magnetised The rotor is magnetised  High torque to inertia ratio  Low torque to inertia ratio  ... rotor has salient pole construction The rotor has mostly smooth cylindrical type of construction. 

Description : What is permanent magnet and electromagnet?

Last Answer : Permanent magnet: A permanent magnet is an object made from a material that is magnetized and creates its own persistent magnetic field. As the name suggests, a permanent magnet is 'permanent'. ... an electric current passes through the coil. If the current is interrupted, the magnetism is lost.

Description : A neodymium magnet is a permanent magnet made from an alloy of _________ A) Neodymium and iron B) Neodymium, iron and iodine C) Neodymium and boron D) Neodymium, iron and boron

Last Answer : A neodymium magnet is a permanent magnet made from an alloy of Neodymium, iron and boron

Description : State the function of former and control spring in PMMC instrument.

Last Answer : Function of Former: To support the coil and provide eddy current damping.  Function of Control Spring: To provide control torque or force and in some instruments springs can be used as current leads.

Description : ‘PMMC instrument is not suitable to measure AC quantity’. State the reason.

Last Answer : The direction of force exerted on moving coil depends on the direction of current flowing through moving coil. If the direction of magnetic field is kept constant, it produces unidirectional torque if the current is ... on the coil in one cycle to zero. Hence the meter cannot read A.C. quantities.

Description : State working principle of PMMC instrument.

Last Answer : Working Principle of PMMC Instrument: When current carrying conductor is placed in a constant magnetic field, it experiences a force proportional to the current and produces proportional deflection torque. 

Description : Compare PMMC & MI instrument.

Last Answer : MI Instrument  PMMC Instrument  It works on the principles of magnetism.  It works on the principle of DC motor Deflection torque is proportional to square of current  Deflection ... , Voltmeter and Watt meter  Can be used as voltmeter, Ammeter, Galvanometer, ohmmeter  

Description : Eddy current damping cannot be used for moving iron instrument because

Last Answer : Eddy current damping cannot be used for moving iron instrument because the presence of a permanent magnet required for such purpose would affect the deflection and hence the reading of the instrument

Description : List two advantages of PMMC instrument.

Last Answer : 1. It has uniform scale. 2. Power consumption is low 3. It can be obtained in wide ranges. 4. High sensitivity & accuracy 5. It is unaffected by external magnetic field. 6. Additional damping device not required. 7. Hysteresis problem is not there.

Description : feature of PMMC instrument. 

Last Answer : Consumes less power Great accuracy. High torque to weight ratio

Description : In a PMMC instrument, the damping provided is :  (A) air damping (C) eddy current damping (B) fluid damping (D) magnetic damping using a magnet

Last Answer : In a PMMC instrument, the damping provided is : eddy current damping 

Description : A moving coil of meter has 100 turns, and a length and depth of 10mm and 20mm respectively. It is positioned in a uniform radial flux density of 200 mT. The coil carrier current capacity is 50 mA. The torque on the coil is

Last Answer : A moving coil of meter has 100 turns, and a length and depth of 10mm and 20mm respectively. It is positioned in a uniform radial flux density of 200 mT. The coil carrier current capacity is 50 mA. The torque on the coil is 200µNm

Description : A moving coil meter has a resistance of 3 Ω and gives full scale deflection with 30 mA. To measure voltage up to 300 V, the external resistance to be connected in series with the instrument is (A) 9997 Ω (B) 10000 Ω (C) 997 Ω (D) 10003 Ω

Last Answer : A moving coil meter has a resistance of 3 Ω and gives full scale deflection with 30 mA. To measure voltage up to 300 V, the external resistance to be connected in series with the instrument is 9997 Ω

Last Answer : A moving iron instrument can be used for both D.C. and A.C.

Description : Peterson coil is used for :  (A) shunt compensation of lines (B) grounding of system neutral (B) reduce fault currents (D) connecting interconnected systems

Last Answer : Peterson coil is used for : grounding of system neutral

Description : Give the classification of the errors used in measuring instrument & state the reason for their occurrence.

Last Answer : Types of errors in measuring instruments:  A) Gross error: These are due to mistakes on the part of person using the instrument.  B) Systematic Error:  i) Instrumental Error: These ... multiplying factor.  C) Random error: These persist even after gross and systematic errors are removed. 

Description : State the material used for making (1) Magnetic Core (2) Fuse element  

Last Answer : The material used for making of:  (1) Magnetic Core : Iron, cobalt, Nickel, CRGO, HRGO , silicon steel  (2) Fuse Element: Tin- lead wire, Tinned copper wire 

Description : State properties of conductor material used for overhead conductor. 

Last Answer : Following are the properties of conductor material:-   1. High conductivity :- Material should have high conductivity 2. High mechanical strength:- Material should have sufficiently high mechanical strength ... available & less costly. 9. Scrap Value: - Material should have high scrap value. 

Description : The material used in liquid fuses is  (1) SF6 (3) carbon tetra chloride (2) distilled water (4) transformer oil

Last Answer : The material used in liquid fuses is  carbon tetra chloride

Last Answer : The insulating material used between the commutator segments is normally mica.

Last Answer : The material used for fuse must have low melting point and high specific resistance.

Description : Permanent Magnet Moving Coil (PMMC) Instrument

Last Answer : Permanent Magnet Moving Coil (PMMC) Instrument

Description : An unshielded moving iron voltmeter is used to measure the voltage in an AC circuit. The stray DC magnetic field having a component along the axis will be  (1) unaffected (2) decreased (3) increased (4) either decreased or increased depending on the direction of the DC field

Last Answer : An unshielded moving iron voltmeter is used to measure the voltage in an AC circuit. The stray DC magnetic field having a component along the axis will be either decreased or increased depending on the direction of the DC field

Description : role of the series resistance connected in PMMC movement.

Last Answer : A PMMC Instrument can be used as voltmeter by just connecting a series resistance with the moving coil. This series resistance is called Voltmeter Multiplier. This combination of moving coil and ... current whose voltage is to be measured. Ideally the resistance of voltmeter should be infinite

Description :  The main sources of Errors in Permanent Magnet moving Coil (PMMC) are due to : - a) weaking of the permanent magnet due to aging at temperature effects b) weaking of spring due to aging and temperature effects c) change of resistance of the moving coil with temperature d) all the above

Last Answer :  The main sources of Errors in Permanent Magnet moving Coil (PMMC) are due to : - a) weaking of the permanent magnet due to aging at temperature effects b) weaking of spring due to aging and temperature effects c) change of resistance of the moving coil with temperature d) all the above

Description : Hard steel is suitable for making permanent magnets because?

Last Answer : Hard steel is suitable for making permanent magnets because it has good residual magnetism.

Description : Those materials are well suited for making permanent magnets which have _____ retentivity and _______ coercivity.

Last Answer : Those materials are well suited for making permanent magnets which have high retentivity and high coercivity.

Description : Permanent magnets are normally made of?

Last Answer : Permanent magnets are normally made of alnico alloys.

Description : A permanent magnet moving coil instrument gives full scale deflection of 25mA when a voltage of 75mV is applied across it. Calculate: (i) Resistance of shunt required for full scale deflection of 150 A. (ii) Series resistance for full scale deflection of 500 V.

Last Answer : Answer :

Description : Describe spring control method of producing controlling torque in measuring instrument. Write any two properties required for spring material.

Last Answer : A)Spring control method: As shown in the figure, the inner ends of the both springs are attahced to the spindle, while outer end of upper spring is attached to the lever and outer ... of spring material: 1.Non Magnetic material 2.Low specific resistance 3.Low temperature coefficient of resistance

Description : A Peterson coil is ________ A) An arc generating coil B) An arc suppressing coil C) An arc inducing coil D) None of these

Last Answer : A Peterson coil is An arc suppressing coil

Description : lt the length, number of turns and area of a coil are  doubled, the inductance of the coil

Last Answer : lt the length, number of turns and area of a coil are  doubled, the inductance of the coil is quadrupled

Description : The initial rate of rise of current through a coil of inductance 10 H when suddenly connected to a D.C. supply of 200 V is_______Vs.

Last Answer : The initial rate of rise of current through a coil of inductance 10 H when suddenly connected to a D.C. supply of 200 V is 20 Vs

Description : The rate of rise of current through an inductive coil is maximum?

Last Answer : The rate of rise of current through an inductive coil is maximum at the start of the current flow.

Description : The inductance of a coil can be increased by?

Last Answer : The inductance of a coil can be increased by choosing core material having high relative permeability.

Description : Inductance of coil?

Last Answer : Inductance of coil increases with the increase in supply frequency.

Description : Inductance of a coil Varies?

Last Answer : Inductance of a coil Varies as directly as the cross-sectional area of magnetic core and inversely as the length of the iron path.

Description : What is the difference between a coil and an inductor?

Last Answer : Inductor is covering with insulating material is called coil.so they differentiate between coil and inductor.

Description : Permanent-magnet moving coil instrument can be used in

Last Answer : dc work only

Description : What is the reason why the scale of a permanent-magnet moving coil instrument is uniform?

Last Answer : because it is spring controlled

Description : What do you mean by coil?

Last Answer : Ans. Having one or more turns connected in series is called coil.

Description : State the function of overload coil and No volt coil in dc motor starter.

Last Answer : Function of Overload Coil: When DC motor is overloaded, the overload coil carries the overload current and produces strong magnetic field to attract a plunger, which short the terminals of ... dc motor is prevented from restarting automatically on recovery of supply without starter and protected.

Description : The purpose of the restraining coil in a biased differential relay is  (A) To reduce CT saturation during fault.  (B) To increase the sensitivity of the relay.  (C) To match the transformation ratio.  (D) To limit the spill current through the relay during heavy external fault.

Last Answer : d

Description : The self inductance of a coil can be measured using (A) Wien’s Bridge (B) Schering Bridge (C) Anderson’s Bridge (D) Wheatstone Bridge

Last Answer : The self inductance of a coil can be measured using Anderson’s Bridge