List any two methods of reactive power measurement in 3 phase circuit.

1 Answer

Answer :

Methods of reactive power measurement in 3 phase circuit: (i) Two single phase wattmeter method (ii) One single phase wattmeter method

Related questions

Description : List different starting methods of three phase synchronous motor. Explain any one of them.

Last Answer : Different Starting Methods of Three Phase Synchronous Motor: As synchronous motor is not self starting, different methods of starting are as follows: 1) By using an Induction (Pony) motor 2) ... . The rotor gets pulled into synchronism and starts running at constant speed as a synchronous motor. 

Description : Explain the term reactive power. Why it is sometimes essential to measure reactive power?

Last Answer : Reactive power: The reactive power (Q) is defined as the product of voltage(V), current (I) and sine of angle between voltage(V) and current( I) Therefore Reactive power Q = V I ... power so that corrective measures can be taken accordingly to maintain systems power factor near to the unity.

Description : what are the importance of reactive power?

Last Answer : Importance of Reactive Power  Voltage level control is important In power system. Varying reactive power will vary voltage level. Reactive power is directly proportional to ... power for useful work. Reactive power is required to generate magnetic flux.

Description : The reactive power transfer over a line mainly depends on

Last Answer : The reactive power transfer over a line mainly depends on lVsl- lVRl

Description : What is the formula for reactive power?

Last Answer : The formula for reactive power is, Reactive power = VI sin (phi) The unit of reactive power is VAR ( Volt ampere reactive). The reactive power is denoted by 'Q'. The formula for real power is, Real power = VI cos (phi) The unit of real power is watts. The real power is denoted by 'P'.

Description : State the different methods of Power Generation adopted in India. 

Last Answer : 1. Hydro energy or hydro Electric power plant  2. Nuclear energy or nuclear Power Plant  3. Fossil fuels: i) Thermal energy (by combustion of coal) or Thermal Power Plant ii) Natural gas ... from any organic waste materials. It contains mixture of methane(50-65 % in volume) and carbon dioxide

Description : State any two disadvantages of one wattmeter method of measurement of 3 phase power.

Last Answer : State any two disadvantages of one wattmeter method of measurement of 3 phase power. Disadvantages of one wattmeter method:- 1. Only used for balanced load 2. It can not be used for ... connection then neutral point must be available 4. Delta connection must be opened to connect current coil.

Description : The apparent power drawn by an A.C. circuit is 10 kVA and active power is 8 kW. The reactive power in the circuit is?

Last Answer : The apparent power drawn by an A.C. circuit is 10 kVA and active power is 8 kW. The reactive power in the circuit is 6 kVAR.

Description : Define balanced and unbalanced load in three phase circuit.

Last Answer : Balanced Load: When all the imedances of 3 phases are equal in magnitude and of same nature then load is said to be balanced.  Unbalanced Load: When all the imedances of 3 phases are not equal in magnitude and of different nature then load is said to be unbalanced.

Description : The product of apparent power and cosine of the phase angle between circuit voltage and current is?

Last Answer : In parllpar reasonans RLC circuit the current is

Description : The power consumed in a circuit element will be least when the phase difference between the current and voltage is?

Last Answer : The power consumed in a circuit element will be least when the phase difference between the current and voltage is 90°.

Description : Use Voltmeter, ammeter, wattmeter to determine active, reactive and apparent power consumed in given R-L series circuit, draw phasor diagram.

Last Answer : Practical Significance In the industry environment Electrical Engineering diploma graduate are expected to measure basic parameters like voltage, frequency, time period etc. for R-L series circuits. Therefore ... /varying L. 7. Draw the phasor diagram for each of reading for verification.

Description : State any four applications of three phase circuits.

Last Answer : The application of three phase circuits are 1. Three phase circuit is used for power transmission over long distances. 2. Three phase circuit can produce rotating magnetic field 3. Three phase ... three phase Motors and Transformers. 4. Three phase circuit is used for power converters circuits.

Description : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole)  (A) has q -axis current only (B) has d -axis current only (C) has both d and q axis currents (D) cannot be divided between q and d axis currents

Last Answer : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole) has d -axis current only

Description : In a 3-phase converter circuit during commutation when one SCR in one phase is turned on to turn-off an SCR in another phase, results in (A) voltage notching (B) harmonic distortion (C) voltage sag (D) voltage swell

Last Answer : In a 3-phase converter circuit during commutation when one SCR in one phase is turned on to turn-off an SCR in another phase, results in voltage notching

Last Answer : Starting winding of a single phase motor of a refrigerator is disconnected from the circuit by means of a magnetic relay.

Description : List the different level measurement methods. 

Last Answer : Liquid Level Measurement Direct method 1. Hook type 2. Sight glass gype 3. Float type 4. Dip stick Indirect method 1. Hydraustatic pressure type 2. Electrical type a) Capacitance level indicator b) Radiation level detector c) Ultrasonic level gauge 3. Radar type

Description : why reactive ohm cannot converted electrical energy into heat?

Last Answer : Because it describes the resistance of element that store energy rather than dissipate energy as heat

Description : With a neat sketch explain working of 1 phase dynamometer type power factor meter.

Last Answer : Working of 1 phase dynamometer type power factor meter : The current coil is connected in series with load. Two pressure coils marked as A and B are connected across the supply terminals ... becomes stationary and the pointer shows steady deflection corresponding to the power factor of the load. 

Description : What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Last Answer : What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Description : Name two methods for measurement of low, medium and high resistance. Give one advantage and one limitation of V- I method.

Last Answer : Methods for measurement of low resistance:  1. Ammeter voltmeter method  2. Kelvin's bridge method  3. Ohm meter method  4. Potentiometer method  5. Digital/analog multi-meter ... must be infinity for perfectly accurate measurement which is not possible.  2. Connection errors.

Description : Precise control of reactive current flow entering the transmission and distribution systems can be minimized by using (A) synchronous condenser (B) static VAR capacitor (C) capacitor bank (D) thyristor switched reactor in parallel with capacitor

Last Answer : Precise control of reactive current flow entering the transmission and distribution systems can be minimized by using (A) synchronous condenser (B) static VAR capacitor (C) capacitor bank (D) thyristor switched reactor in parallel with capacitor

Last Answer : In a single phase power factor meter the phase difference between the currents in the two pressure coils is exactly 90°.

Last Answer : The two pressure coils of a single phase power factor meter have the same dimensions and the same number of turns.

Last Answer : The power factor of a single phase load can be calculated if the instruments available are three ammeters or three voltmeters.

Description : In an alternator at lagging power factor the generated voltage per phase as compared to that at unity power factor?

Last Answer : In an alternator, at lagging power factor the generated voltage per phase as compared to that at unity power factor must be more than terminal voltage.

Description : Briefly explain how the power factor of an inductive circuit can be improved.

Last Answer : As we know that power factor should be corrected to ensure that the current supplied is cost friendly. Meaning the power factor should be around one but not greater than one(0.8-0.9) in a ... an inductive circuit due to the inductive reactance which oppose the change of current in the ac circuit. 

Description : State maximum power transfer theorem for DC circuit.

Last Answer : Maximum power transfer theorem for DC circuit: The maximum power transfer theorem states that the source or a network transfers maximum power to load only when the load resistance is equal ... removed (disconnected) ii) All internal independent sources are replaced by their internal resistances.

Description : The power factor of a D.C. circuit is always?

Last Answer : The power factor of a D.C. circuit is always unity.

Description : In an A.C. circuit power is dissipated in?

Last Answer : In an A.C. circuit power is dissipated in resistance only.

Description : The input of an A.C. circuit having power factor of 0.8 lagging is 40 kVA The power drawn by the circuit is?

Last Answer : The input of an A.C. circuit having power factor of 0.8 lagging is 40 kVA The power drawn by the circuit is 32 kW.

Description : Pure inductive circuit takes power from the A.C. line when?

Last Answer : It takes power when voltage decreases and current increases.

Description : The power factor at resonance in R-L- C parallel circuit is?

Last Answer : since a rlc circuit at resonance behaves like a pure resistive circuit, i.e there is no phase difference between current and voltage, hence the power factor is unity.

Description : Power factor of an inductive circuit is usually improved by connecting capacitor to it in?

Last Answer : Power factor of an inductive circuit is usually improved by connecting capacitor to it in parallel.

Description : Power factor of an electrical circuit is equal to?

Last Answer : Power factor of an electrical circuit is equal to R/Z, cosine of phase angle difference between current and voltage, kW/kVA.

Description : What is the power factor of purely resistive circuit.

Last Answer : Unity that is 1

Description : What is drive circuit in power electronics?

Last Answer : Driver is used for Motion Control through the use of power electronics.

Description : List the different methods to produce damping torque.

Last Answer : Methods of providing damping torque in indicating type instruments: 1) Air friction damping. 2) Fluid friction damping. 3) Eddy current damping.

Description : In a pure resistive circuit, the average power Pavg is ______ the peak power Pmax. (1) Double (2) One-half of (3) One-fourth (4) Equal to

Last Answer : In a pure resistive circuit, the average power Pavg is One-half of the peak power Pmax.

Description : A snubber circuit is connected to the power semiconductor device to reduce the (A) turn-on time (B) turn-off time (C) electrical stresses (D) thermal resistance

Last Answer : A snubber circuit is connected to the power semiconductor device to reduce the electrical stresses

Last Answer : Air blast circuit breakers for 400 kV power system are designed to operate in 50 millisecond.

Description : How do you find power in a circuit?

Last Answer : Power can be find in a circuit by the means of meters .if an individual want to check for a power in a circuit he/she Calabria the meters on a high voltage range and put the meters Lee in parallel with the circuit he /she will know the amount of power within that circuit .

Description : List various transistor biasing methods.

Last Answer : Types of biasing methods: i. Base bias (or fixed bias) ii. Base bias with emitter feedback. iii. Base bias with collector feedback iv. Voltage divider bias (or self bias) v. Emitter bias. 

Description : How are nuclear reactors controlled? Explain two different methods in brief.

Last Answer : Nuclear reactor is controlled using control rods: Control rods are made up of very high neutron absorbing material like boron, cadmium. By adjusting height of control rods on reactor core ... of nuclear reaction will increase. Whereas by pushing control rod towards the core it will reduce.

Description : What are your methods for dealing with unwarranted not to say unwanted attention from a drunk?

Last Answer : answer:I interact briefly, and loudly, eg YES, IT IS A NICE DRESS ISN'T IT? as I firmly walk away Or, if I am not in a situation where I can't walk away, I just give a half- ... ha ha! I am someone that makes eyecontact with people, and generally quite smiley so I guess I must seem approachable!

Description : State the various lighting calculations methods and Describe any one of them.

Last Answer : Lighting calculation methods: 1. Lumens or Light flux method 2. Point to point or Inverse Square law method 3. Watts per Square meter method i) Lumens or Light ... is taken according to the illumination desired on an average value considering overall efficiency of the lighting system.

Description : Describe the following energy conservation methods of lighting system. i) By replacing lamp sources ii) Using light control gears.

Last Answer : Energy conservation methods of lighting system:  i) By replacing lamp sources:  Installation of energy efficient fluorescent lamps in place of Conventional fluorescent lamps. Installation of ... (HF) electronic ballasts in place of conventional ballasts which saves energy up to 35%.

Description : Describe the following energy conservation methods of electrical motor. i) By motor survey ii) By matching loads with motor rating

Last Answer : Energy conservation methods of electrical motor:  1) By Motor Survey: Large industries have a massive population of LT motors. Load survey of LT motors can be taken-up methodically to ... -speed motors, eddy-current couplings, fluid couplings, and solid-state electronic variable speed drives.

Description : Identify the correct combination of respective Electric arc welding and Electric resistance welding methods :  (A) Butt welding and Seam welding  (B) Hydrogen shielding and Projection welding  (C) Seam welding and Coated electrode welding  (D) Coated electrode welding and Hydrogen shielding

Last Answer : Identify the correct combination of respective Electric arc welding and Electric resistance welding methods :  (A) Butt welding and Seam welding  (B) Hydrogen shielding and Projection welding  ... Seam welding and Coated electrode welding  (D) Coated electrode welding and Hydrogen shielding

Description : What are the speed control methods of dc motor?

Last Answer : Field control of DC motor Armature control of DC motor