State the meaning of creeping error in 1 phase energy meter.

2 Answers

Answer :

Creeping error: It is defined as the slow and continuous rotation of the disc of the energy-meter when only pressure coil is energized with no current in the current coil (load current = 0). 

Answer :

Creeping error: It is defined as the slow and continuous rotation of the disc of the energy-meter when only pressure coil is energized with no current in the current coil (load current = 0). In order to prevent the creeping on no load, two holes are drilled in the disc on diametrically opposite sides of the spindle. This causes sufficient distortion of the field to prevent rotation of the disc when one of the holes comes under the pole of shunt magnet. Also in other case, small piece of iron wire is attached to the edge of the disc. The force of attraction is exerted by the brake magnet on this iron wire is sufficient to prevent continues rotation of the disc on no load condition.

Related questions

Description : The disc of a single phase Induction-type energy meter makes 60 revolutions in 6 minutes. Meter Constant is 1200 rev/kWh. Power consumption in the load is (A) 1.2 kW (B) 1 kW (C) 600 W (D) 500 W

Last Answer : The disc of a single phase Induction-type energy meter makes 60 revolutions in 6 minutes. Meter Constant is 1200 rev/kWh. Power consumption in the load is 500 W

Description : Describe the following errors and their compensation: (i) Phase error (ii) Speed error

Last Answer : (I) Phase error   1. In the phase error the phase difference angle between ∅ & ∅ is kept by using the shading band/ring  2. If the design and location of Shading band/ring is ... of brake magnet. By changing the position of the brake magnet speed of the rotating disc can be controlled. 

Description : State the application of phase sequence indicator; clip on ammeter, frequency meter & P.F. meter.

Last Answer : Phase Sequence Indicator:  1. For finding correct phase sequence of supply  2. For obtaining exact instant of parallel operation of alternators.  3. For obtaining reversal of rotation ...  4. In electroplating industries   5. In various processes industries for measuring power factor

Description : With a neat sketch explain working of 1 phase dynamometer type power factor meter.

Last Answer : Working of 1 phase dynamometer type power factor meter : The current coil is connected in series with load. Two pressure coils marked as A and B are connected across the supply terminals ... becomes stationary and the pointer shows steady deflection corresponding to the power factor of the load. 

Description : What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Last Answer : What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Last Answer : In a single phase power factor meter the phase difference between the currents in the two pressure coils is exactly 90°.

Last Answer : The two pressure coils of a single phase power factor meter have the same dimensions and the same number of turns.

Description : An induction type energy meter is found to run fast. Correction for this error can be made by  (A) Over-load compensation. (B) Voltage compensation. (C) Moving the brake magnet away from the centre of the disc. (D) Moving the brake magnet towards the centre of the disc.

Last Answer : An induction type energy meter is found to run fast. Correction for this error can be made by Moving the brake magnet away from the centre of the disc.

Description : Sanvitalia - Creeping Zinnia (Sanvital'ia)

Last Answer : DESCRIPTION: This annual belongs to the Daisy family, Compositae and is a native of Mexico. This trailing plant grows up to 6 inches high and will spread 2 to 3 feet. Its ovate to wide lanceolate ... soil warms. The seeds need light to germinate, so don't cover them. VARIETIES: S. procumbens

Description : State the function and shape of following parts used in induction type energy meter: i) Series magnet ii) Shunt magnet iii) Al disc iv) Brake magnet

Last Answer : i) Series magnet: produce flux proportional to current (load current) of circuit and interact in the aluminum disc with flux produced by voltage magnet for torque production. Its shape is like letter U.  ii) ... : brakes the motion of the aluminum disc or slows it down. Its shape is like letter C. 

Description : Draw a block diagram of electronic energy meter. Write function of each block.

Last Answer : Electronic Energymeter  Functions of components/blocks: - CT reduces current to reasonable value for current scaling network. - Voltage & current scaling networks reduce proportionally the voltage ... ADC converts the square wave frequency analog output to display the energy in watthour.

Description : Draw a neat sketch of 1-ph induction type energy meter and write operating principle of it. 

Last Answer : Operating Principal:- The disc is placed between the two-flux due to pressure coil and flux due to current coil, which will set up torque on the disc which is proportional to power causing the ... is proportional to voltage, the second carries a current coil so its flux is proportional to current.

Description : Draw and describe working of electronic energy meter.

Last Answer : working of electronic energy meter:- 1. CT reduces current to reasonable value for current scaling network. 2. Voltage & current scaling networks reduce proportionally the voltage & ... The ADC converts the square wave frequency analog output to display the energy in watthour. 

Description : What is meant by energy meter constant?

Last Answer : Energy Meter Constant  A fixed value which is used when converting meter readings to actual energy use, especially when potential transformers and similar types of equipment are used in metering. For example, K=--------rev/Kwh

Description : With neat diagram explain calibration of energy meter by direct loading method.

Last Answer : Calibration of Energy Meter by Direct Loading Method:  There are three methods for testing/calibration:  1. Long period dial test  2. Using rotary sub- standard meter  3. Using precision grade instruments  All ... of substandard meter in kWh  Then % error = [(D - DS)/DS] x 100

Description : Why energy meter is integrating type measuring instrument?

Last Answer : Energy Meter is Integrating Type Measuring Instrument: Energy meter is used for measurement of energy, which is obtained by integration (summation) of power supplied over the particular time duration, hence it the integrating type measuring instrument. 

Description : Write any two advantages of digital energy meter.

Last Answer : Advantages of Digital Energy Meter: 1) Easy to read. 2) High accuracy 3) High resolution. 4) No frictional losses as there are no moving parts. 5) No requirement for external adjustments. 6) Large ... due to absence of moving parts. 7) Highly efficient. 8) Very much compact. 9) Good reliability.

Description : List any four errors in induction type energy meter. Give method of compensation for each.

Last Answer : Errors in Induction Type Energy Meter with their Compensation:  1) Error due to friction: This error can be compensated by the additional shading band provided on the shunt electromagnet.  2) Phase ... error: This error can be compensated by providing a flux diverter' to the current magnet. 

Description : Explain the “mitigation of power theft” and “faulty meter replacement” for energy conservation techniques to reduce commercial losses. 

Last Answer : Energy conservation techniques to reduce commercial losses:  1. Mitigation of Power Theft: Power theft being the most important issue which all of the service providing utilities ... agricultural sector. Prepaid meters may prove effective measures against unauthorized abstraction of energy. 

Description : A 200 V, 5 A d.c. energy meter is tested at its marked ratings. The resistance of the pressure circuit is 8000 Ω and that of current coil is 0.1 Ω. The power consumed when testing the meter with phantom loading with current circuit excited by a 6 V battery is (A) 2.5 W (B) 5 W (C) 32.5 W (D) 35 W

Last Answer : A 200 V, 5 A d.c. energy meter is tested at its marked ratings. The resistance of the pressure circuit is 8000 Ω and that of current coil is 0.1 Ω. The power consumed when testing the meter with phantom loading with current circuit excited by a 6 V battery is 35 W

Description : Phantom loading for testing of energy meter is used (A) to isolate the current and potential circuits (B) to increase power loss during testing (C) for meters having low current ratings (D) to test meters having a large current rating for which loads may not be available

Last Answer : B

Last Answer : The adjustment of position of shading bands, in an energy meter is done to provide friction compensation.

Last Answer : The household energy meter is an integrating instrument.

Description : Explain following techniques related to energy conservation in transmission and distribution system. (i) By balancing phase currents (ii) Variable technical losses (I2R losses).

Last Answer : (i) Balancing Phase currents: Proper (healthy balanced) three phase loads always draw equal currents in all lines but single phase loads in the 3 phase 4 wire system or loads connected between two ... . 11) Minimize I2R losses. 12) Balance the load currents. 13) Regulate the system voltages.

Last Answer : Induction type single phase energy meters measure electric energy in kWh.

Description : What is the percentage error when 3 resistors with ratings 100 Ω at 5%, 150 Ω at 6% and 250 Ω at 8% respectively, are connected in series? A) 6.33% B) 6.80% C) 19% D) None of these

Last Answer : What is the percentage error when 3 resistors with ratings 100 Ω at 5%, 150 Ω at 6% and 250 Ω at 8% respectively, are connected in series? A) 6.33% B) 6.80% C) 19% D) None of these

Description : How can the steady-state error in a system be reduced?  (1) By decreasing the type of system (2) By increasing system gain (3) By decreasing the static error constant (4) By increasing the input

Last Answer : How can the steady-state error in a system be reduced?  (1) By decreasing the type of system (2) By increasing system gain (3) By decreasing the static error constant (4) By increasing the input

Description : In order to regulate steady state error to zero, in a negative feedback control system, one employs

Last Answer : In order to regulate steady state error to zero, in a negative feedback control system, one employs Integral control

Description : The steady state error of the system can be minimized by

Last Answer : The steady state error of the system can be minimized by increasing gain k

Description : I keep getting "Forbidden Error" when messaging or trying to edit, how come?

Last Answer : I don’t know much about computers, but I found multiple websites when I searched for Forbidden 403. Among other “fixes”, you need to delete your browsing history and make sure your cookies are enabled. http://pcsupport.about.com/od/findbyerrormessage/a/403error.htm

Description : What is the channel capacity of a noisy channel with conditional probability of error p = 1/2? A) 0 B) 1 C) Infinity D) 2  

Last Answer : What is the channel capacity of a noisy channel with conditional probability of error p = 1/2?  A) 0 B) 1 C) Infinity D) 2  

Description : True value has been 50 whereas measured value is 40 then the percentage error in the reading will be ______.  (A) 20% (B) 40% (C) 50% (D) 30%

Last Answer : True value has been 50 whereas measured value is 40 then the percentage error in the reading will be 20%. 

Description : What are the types of error?

Last Answer : Human error or gross error, systematic error, applicational error and random error are the types of error.

Description : If stability error for step input and speed of response be the criteria for design, what controller would you recommend (1) P controller (2) PD controller (3) PI controller (4) PID controller

Last Answer : If stability error for step input and speed of response be the criteria for design, what controller would you recommend (1) P controller (2) PD controller (3) PI controller (4) PID controller

Description : What is measurement error ?

Last Answer : Measurement error :- Measurement is the process of comparing unknown quantity with known or standard quantity. Error is the difference between ... by fluctuations in reading measurement apparatus. Random error show different result for same repeated measurement.

Last Answer : In a dynamometer 3-phase power factor meter, the planes of the two moving coils are at 120°.

Description : State one application of clip on meter.

Last Answer : Clip-on meter is used to measure the High value AC current without breaking the circuit Or without opening the circuit.

Description : State advantages & disadvantages of electromagnetic flow meter.

Last Answer : Advantage: Provides wide linear range. 2) Ability to measure reverses flow. 3) Gives rapid response to flow changes. 4) No obstruction is created to flow. 5) It can handle corrosive as ... and pipe networks with relatively short inside diameters. 3) It is useful for electrically conducting fluid.

Description : State the use of shunt and series resistance used in extension of meter.

Last Answer : Use of shunt and series resistance: i) Use of shunt: To extend the range of Ammeter. ii) Use of series resistance: To extend the range of Voltmeter.

Description : working of distortion factor meter with block diagram

Last Answer : Working : Initially the switch S is kept at position 1.The attenuator gets excluded and the bridge T network is adjusted for full suppression of fundamental frequency and hence we get ... is obtained on the meter.Thus the total rms distortion is indicated by the reading of attenuator. 

Description : Principal of digital frequency meter.

Last Answer : The basic block diagram of basic digital frequency meter (DFM) is shown in above figure. The signal whose frequency we have to be measured is first to be amplified through amplifier. The output of amplifier ... = Number of counts. t = Time interval between start and stop condition of the gate.

Description : Compare variable head flow meter with variable area flow meter.

Last Answer : Parameter Variable head flowmeter Variable area flowmeter Working principle Restriction or obstacle is placed in the path of flow to create a differential Pressure. The pressure ... viscous fluid slurries and dirty fluids. In laboratories and testing and production lines.

Description : Describe principle of operation of Doppler type ultrasonic flow meter with diagram. 

Last Answer : Diagram: Working:  The flow meter consists of a crystal transducer mounted outside the pipe in which flow is to be measured. This transducer is a piezoelectric crystal which ... , so the frequency of the reflected wave is shifted to particle velocity, according to Doppler principle.

Description : Draw the diagram and explain the working of ferrodynamic type frequency meter. 

Last Answer : Ferrodynamic type frequency meter: (Electrical resonance type frequency meter): It consists of a fixed coil. The supply whose frequency is to be measured is connected across it. This coil ... so selected that the moving coil takes up a convenient position when frequency is of normal value. 

Description : Write the working of L-C-R meter with suitable sketch.

Last Answer : LCR meter: A LCR meter (Inductance L, Capacitance C, and Resistance R) test equipment used to measure the inductance, capacitance and, resistance of a component. It works on the principle ... relative change in magnitude of the repetitive variations of the voltage and current known as amplitudes.

Description : Describe with working of LCR meter for measurement of inductance. 

Last Answer : working of LCR:- A LCR meter (Inductance (L), Capacitance (C), and Resistance (R) test equipment used to measure the inductance, capacitance and, resistance of a component. It works on the ... in parallel (as would be encountered in measuring a capacitor with a leaky dielectric) [Q setting ] 

Description : Explain working of Weston type frequency meter.

Last Answer : Weston Type Frequency Meter: There are two fixed coils marked as A and B. Each coil divided into two equal parts and are fixed such that their magnetic axis are perpendicular to each ... leading to deflections in either direction depending on the currents there in, due to changed impedances.

Description : kWh meter is the electric meter that measures the amount of electrical _________ in kWh that was consumed in the house.  (A) Energy (B) Current (C) Voltage (D) None of the above

Last Answer : kWh meter is the electric meter that measures the amount of electrical Energy in kWh that was consumed in the house. 

Description : Would this gauss meter be any good?

Last Answer : answer:Oooo!!! Did you get the Chony? Made in Mississigua Ont? I have one of those and love it. I cannot tell about the gauss meter. TI could be anything. Sorry. The Chony on the other hand is fantastic.

Description : What is meter rule

Last Answer : It is a one meter long graduated stick. It is used to measure the length of an object or distance between two points. A meter rule is divided into 100 equal parts, each part is equal to one centi meter.