State the functions of fuel system and exhaust system of a diesel power station.

1 Answer

Answer :

Fuel system: It supplies fuel to engine for combustion purpose. It consists of Fuel Pump: - It supplies fuel to engine for combustion purpose. Strainer: - Are provided to remove suspended impurities and to supply clean fuel to engine. Fuel Injector: - It injects fuel in engine cylinder at the end of compression stroke. Heaters: - Are provided to heat the coil especially during winter season


Exhaust system: This system is provided to discharge the engine exhaust (smoke) to the atmosphere outside the building. It consists of ; Silencer: - It is provided to reduce noise. Muffler: - It is provided to exhaust pipe to reduce pressure in exhaust line and eliminate most of the noise. Chimney:- To exhaust gases in the atmosphere as high as possible. 

Related questions

Description : State the functions of following elements: i) Diesel engine system ii) Air intake system iii) Engine exhaust system iv) Engine starting system.

Last Answer : i) Diesel engine system:-  Four strokes Two strokes ii) Air intake system:- Air intake system is provided to supply air to engine cylinder for fuel combustion.  iii) Engine exhaust system ... provided to rotate the engine initially until the firing starts and engine run under its own power. 

Description : Explain fuel system and air intake system in diesel electric power plant.

Last Answer : Fuel system and air intake system in diesel electric power plant :  Fuel system: It consists of storage tank, strainers, fuel transfer pump and all day fuel tank. The fuel oil is supplied ... Filters are provided to remove dust particles from air which may act as abrasive in the engine cylinder.

Description : Applications of Diesel power station

Last Answer : Applications of Diesel Power Station:  1. It can be used as a standby (emergency) power plant to maintain continuity of supply. (Incase failure of main supply like hospital, Telephone exchange Radio ... 10. Diesel plants are widely used for generating power ranging from 100 to 5,000 H.P. 

Description : List out main components of Diesel power station. 

Last Answer : Main components of Diesel power station: 1) Diesel Engine 2) Engine Air intake system 3) Engine Fuel System 4) Engine Exhaust system 5) Engine cooling system 6) Engine Lubricating system 7) Engine Starting system 8) Diesel Engine Generator (Alternator) 

Description : Explain starting system in diesel electric power plant.

Last Answer : Starting system in Diesel Electric Power Plant: It includes Storage battery, compressed air tanks, self-starter etc. The purpose of engine starting system is to rotate the engine initially while ... as Ammeters, Voltmeters, Wattmeters, Thermometers, Pressure gauges, Visible and audible alarm etc.

Description : Diesel Fuel Pumps

Last Answer : A diesel fuel pump, as the name suggests, is a pump for diesel engines. A diesel engine uses internal combustion to work. The pump is an essential component of the internal combustion process. The internal ... needs to be replaced because of damage, it is best to take the car to a repair shop.

Description : State elements of diesel electric power plant with their functions. 

Last Answer : Elements of Diesel Power Plant with their function):   1) Diesel Engine: - This is the main component of the P.P. which develops mechanical power. 2) Engine air intake system: - Air ... fuel as per requirement. 10) Alternator: - Its function is to convert mechanical power into electrical power.

Description : State why nuclear power plants are used as base load plants and diesel power plants as a peak load plant. 

Last Answer : 1. Because of following points Nuclear power plant used as base load power plant:-  1. Nuclear power plants is very economical for producing bulk amount of electric power 2. Nuclear power plant is reliable ... . The plants can be put on load easily. 4. Diesel engines take less time to make OFF.

Description : State any two applications of diesel power plants.

Last Answer : Applications of Diesel Power Plant: 1. It can be used as a standby (emergency) power plant to maintain continuity of supply. (Incase failure of main supply like hospital, Telephone exchange Radio ... . The diesel units can be used to supply the auxiliaries for starting the large thermal plants.

Description : State any four advantages and four disadvantages of diesel electric power plant. 

Last Answer : Advantages of Diesel electric power plant:- 1) The design and layout of Diesel electric power plant is simple. 2) It requires less space. 3) Time required for complete erection of diesel power plant is less ... . 9) The useful life is very short. 10) Availability of fuel in future may be limited.

Description : State the different types of engines in diesel power plant.

Last Answer : Types of engines in diesel power plant: 1) Two Stroke Diesel Engine 2) Four Stroke Diesel Engine

Description : List out the four applications of diesel electric power plant.

Last Answer : Applications of Diesel Power Plant: 1. It can be used as a standby (emergency) power plant to maintain continuity of supply. (Incase failure of main supply like hospital, Telephone exchange Radio stations, ... 10. Diesel plants are widely used for generating power ranging from 100 to 5,000 H.P.

Description : State the function of following components of a nuclear power station: i) Moderator ii) Shielding iii) Control rod iv) Coolant 

Last Answer : i) Function of Moderator :- Moderator is to moderate or reduce the speed of fast neutron to help the fission process.  ii) Function of sheilding : Shielding is to protect environment, ... from reactor core and transfer it in heat exchanger for producing steam at high pressure and temperature. 

Description : State the types of radioactive waste generated in a nuclear power station. Explain the methods employed for their disposal.

Last Answer : Types of radioactive waste: The waste produced in nuclear power plant is in the form of solid, liquid & gases, 1. Solid Waste Disposal:-  Solid wastes removed from the reactor are very ... are measured. If it is safe then released to atmosphere at high level through large height chimney.

Description : List and state any four limitations of inter connected power station.

Last Answer : Limitations of inter connected power station:- 1) Initial cost of infrastructure of transmission line increases as length increases. 2) Interconnection required more automation which increases cost on ... capacity. But in absence of surplus power merits of interconnection cannot be obtain.

Description : State the function of cooling tower and condenser in thermal power station.

Last Answer : 1. Condenser:   Function of condenser is to convert exhaust steam again into water by reducing its temperature with the help of cold water. Also it reduces back pressure of steam turbine 2 ... tower : The function of cooling tower is to reduce the temperature of water coming from condenser.

Description : State the purpose of surge tank and spill way in hydroelectric power station.

Last Answer : Surge tank :- A surge tank is the small reservoir or tank. It is open at the top. It is installed near Vale house of turbine. It avoids water hammer effect when load on turbine reduces. (It ... ; during floods etc. In this way spill way avoids damage of dam due to excess pressure of water.

Description : State any four factors governing Selection of site for thermal power station. 

Last Answer : Following Factors are to be considered:- 1. It should locate near coal mine. 2. Sufficient quantity of water should be available. 3. Sufficient large space should be available. 4. It should be located ... laws of the land and the town planning. 14. The interests of national defense must be served.

Description : Compare the Nuclear power station with Hydro power station. 

Last Answer : SR. No.  Points Nuclear Power plant  Hydro Power station  1 Site/ Location Where there is ample supply of water is available, away from thickly populated areas to avoid radioactive ... Field Application As base load  Used as base load during as well as peak load 

Description : Classify condensers used in thermal power station. Explain each type in brief. 

Last Answer : Types of condenser: Classification: 1. Jet Condenser (Mixing Type) 2. Surface condenser (non Mixing type)  Explanation:-   1. Jet Condenser (Mixing Type) In Jet condenser the steam ... there in no direct contact between the steam and cooling water. This condensate is reused in boiler. 

Description : Explain the working of Hydro power station with schematic layout. 

Last Answer : Working of Hydro- Electric Power Plant: Water stored at high level by constructing dam across river. This stored water has potential energy. This stored water is passed to run the water ... energy and Alternator is coupled to water turbine which converts mechanical energy into electrical energy. 

Description : "Efficiency of thermal power station is low". — Justify. 

Last Answer : Justification: Efficiency of thermal power station is low":- Overall efficiency of T.P.P depends upon efficiency of boiler, turbine and alternator. The heat produced due to combustion of coal ... losses in thermal power plant is 71%, So efficiency of thermal power plant is less about 29% 

Description : "Hydro electric power station are not perennial power station". Justify.

Last Answer : Justification: The water utilized by the hydro power plants comes mostly from storage dams/reservoirs which get filled up during the monsoon rainy season. Such reservoirs are utilized for supplying ... are important. Hence "Hydro electric power stations are not perennial power station" 

Description : Write down any two advantages of nuclear power station.

Last Answer : Advantages of nuclear power station :-  1) Fuel required: Fuel requirment of Nuclear Power Plant is less than Thermal Power Plant. So it reduces transportation cost of fuel and space required for fuel storage ... By use of nuclear fuel.,it saves the other fossile fuels like-coal, gas, oil, etc.

Description : How Do I Build a Low Power FM Radio Station?

Last Answer : How Do I Build a Low Power FM Radio Station? A low power FM radio station offers individuals or small groups the ability to go on the air and communicate with the general public using FM radio ... FCC or your local government to determine which, if any FM frequencies you are allowed to transmit on.

Description : Power station having Load factor = 70%, capacity factor = 50%, used factor = 60%, maximum demand = 20MW then annual energy production is  (1) 122.8 GWh (2) 198.55 GWh (3) 128.2 GWh (4) 188.82 GWh

Last Answer : Power station having Load factor = 70%, capacity factor = 50%, used factor = 60%, maximum demand = 20MW then annual energy production is 122.8 GWh

Last Answer : For high value of diversity factor, a power station of given installed capacity will be in a position to supply more number of consumers.

Last Answer : Load factor of a power station is generally less than unity.

Last Answer : Load factor of a power station is defined as average load/maximum demand.

Last Answer : For the protection of power station buildings against direct strokes the requirements are interception, conduction and dissipation.

Description : For optimum generator scheduling for different power plants, the minimum fuel cost is obtained when

Last Answer : For optimum generator scheduling for different power plants, the minimum fuel cost is obtained when The incremental fuel cost of each plant multiplied by the penalty factor is the same

Description : Which supply and exhaust fan to choose for your home?

Last Answer : Usually, "European-style renovation" begins with the installation of double-glazed windows and careful closure of all existing ventilation openings in the room. It is interesting, but few people know that ... street, for which fans are used, which are inserted directly into the window or window.

Description : Sketch block diagram of satellite earth station and state functions of each block

Last Answer : The figure below shows the general block diagram of an earth station capable of transmission, reception and antenna tracking. The following are the major subsystems of ... , possible monitoring of satellite characteristics and occasionally for the measurement of special characteristics. 

Description : steady-state stability of a power system is improved by

Last Answer : steady-state stability of a power system is improved by using double circuit line instead of single circuit line

Description : What is the choice of size and number of generator units in interconnected power system?

Last Answer : Choice of Size and Number of Generating Units: 1. The size/rating and number of generating units in such way that they approximately match with the load curve as closely as possible. 2. In ... , if power plant is connected to grid system then generating unit of higher capacity can be installed.

Description : Power factor of the system is kept high?

Last Answer : Power factor of the system is kept high to reduce line losses, to maximise the utilization of the capacities of generators, lines and transformers, to reduce voltage regulation of the line.

Last Answer : The steady state stability of the power system can be increased by connecting lines in parallel.

Description : Summerise the role of power system engineer.

Last Answer : Role of power system engineer:  i. On the planning side he or she has to make decisions on how much electricity to generate  ii. For operation of the power system he has to plan for ... for energy conservation and load management. viii. For solving the power system problems he has to update with

Description : The stability of the power system is not affected by  (1) generator reactance (2) line reactance (3) line losses (4) output torque

Last Answer : The stability of the power system is not affected by line losses

Description : Generally in a power system network, the load is represented as a :  (A) Constant power in both load flow study and in stability study  (B) Constant power in load flow study and constant ... impedance in load flow study  (D) Constant impedance in both load flow study and in stability study

Last Answer : Generally in a power system network, the load is represented as a : Constant power in load flow study and constant impedance in stability study 

Description : A lightening arrester connected between the line and earth in a power system  (1) protects the terminal equipment against travelling surges (2) protects the transmission line against direct ... suppresses high frequency oscillations in the line (4) reflects back the travelling wave approaching it

Last Answer : A lightening arrester connected between the line and earth in a power system protects the terminal equipment against travelling surges

Description : In voltage source converter based HVDC transmission system the active power is controlled by changing (A) phase angle of the converter ac input voltage (B) supply frequency of the converter ac input voltage (C) magnitude of the converter ac input voltage (D) DC voltage at the inverter terminals

Last Answer : In voltage source converter based HVDC transmission system the active power is controlled by changing phase angle of the converter ac input voltage

Description : The benefit of power factor correction in a power system is (A) lower power consumption (B) increased demand charge (C) reduced load carrying capabilities in existing lines (D) reduced voltage profile

Last Answer : The benefit of power factor correction in a power system is lower power consumption

Description : If non-linear loads are connected to the power system, then (A) displacement power factor is same as the total power factor (B) displacement power factor is not equal to the total power ... factor is due to harmonic currents (D) total power factor is due to fundamental component of current

Last Answer : If non-linear loads are connected to the power system, then displacement power factor is not equal to the total power factor

Description : For a 15-bus power system with 3 voltage controlled buses, the size of Jacobian matrix is

Last Answer : For a 15-bus power system with 3 voltage controlled buses, the size of Jacobian matrix is 25 x 25

Description : With fault clearing time, the transient stability of a power system

Last Answer : With fault clearing time, the transient stability of a power system decreases

Last Answer : Commonly used instruments in power system measurement are induction.

Last Answer : In a distribution system, in order to improve power factor, the synchronous capacitors are installed at the receiving end.

Last Answer : The primary reason for low power factor is supply system is due to installation of induction motors.

Last Answer : Air blast circuit breakers for 400 kV power system are designed to operate in 50 millisecond.