The type of joint generally used in cast iron pipes, is
(A) Socket and spigot joint
(B) Flanged joint
(C) Dresser coupling joint
(D) All the above

1 Answer

Answer :

(D) All the above

Related questions

Description : The joint used for joining the plain ends of cast iron pipes, is  (A) Flanged joint  (B) Socket and spigot joint  (C) Dresser coupling joint  (D) Flexible joint 

Last Answer : (C) Dresser coupling joint 

Description : In pumping stations, the type of joint generally used, is (A) Socket and spigot joint (B) Flanged joint (C) Expansion joint (D) Dresser coupling joint

Last Answer : (B) Flanged joint

Description : __________ joint is usually used for joining cast iron pipes mostly used for temporary pipelines, where it may be necessary to dismantle & reassemble the pipeline very frequently. (A) Collar (B) Flanged (C) Bell and Spigot (D) Expansion

Last Answer : Option B

Description : Asbestos pipes are joined by means of (A) Flanged joint (B) Flexible joint (C) Dresser coupling joint (D) Simplex joint

Last Answer : (D) Simplex joint

Description : Large diameter reinforced cement concrete (RCC) pipes are generally joined by __________ joint. (A) Flanged iron (B) Collar (C) Flexible (D) Expansion

Last Answer : Option B

Description : At the socket and spigot joint, (A) Enlarged end of the pipe is called socket (B) Normal end of the pipe is called spigot (C) Spigot is fitted into the socket (D) All the above

Last Answer : (D) All the above

Description : Which of the subsequent must not be a section of cotter joint? a) Socket b) Spigot c) Cotter d) Collar

Last Answer : d) Collar

Description : Which of the following is not a part of cotter joint? a) Socket b) Spigot c) Cotter d) Collar

Last Answer : d) Collar

Description : Explain About Spigot And Socket Joint?

Last Answer : This joint is generally used to connect cast iron pipes which are buried in ground .This is also suitable for straight pipe line carrying water and this joint has less rigidity.

Description : Glass pipes can be joined by (A) Flanges (B) Welding (C) Soldering (D) Bell and spigot joint

Last Answer : (D) Bell and spigot joint

Description : Cast iron pipes are generally preferred to, because (A) Of moderate cost (B) Of ease to join (C) Of longer life (D) All the above

Last Answer : (D) All the above

Description : __________ joint is mostly used for joining pipes carrying water at low pressure. (A) Nipple (B) Socket (C) Union

Last Answer : Option B

Description : Cast iron detachable joint is used in __________ pipes. (A) Steel (B) Cast iron (C) Asbestos cement (D) Reinforced cement concrete

Last Answer : (A) Steel

Description : Lead is poured into the joint between two- __________ pipes. (A) Mild steel (B) Concrete (C) Cast iron (D) Asbestos cement

Last Answer : (C) Cast iron

Description : Lead is poured into the joint between two __________ pipes. (A) Mild steel (B) Concrete (C) Cast iron (D) Asbestos cement

Last Answer : Option C

Description : The type of pipe commonly used in water supply distribution schemes, is  (A) R.C.C. pipes  (B) Hume pipes  (C) Cast iron pipes  (D) G.I. pipes

Last Answer : (C) Cast iron pipes

Description : Find the shear stress in a flange at the junction of hub in rigid flanged coupling if torsional moment is 2980N-m and diameter of hub being 125mm. Also the thickness of flange is 25mm. a) 6.77N/mm2 b) 10.24N/mm2 c) 4.84N/mm2 d) 4.22N/mm2

Last Answer : c) 4.84N/mm2

Description : Actual stress in the bolts of a flanged coupling of a shaft will be (a) More than the designed strength (b) Less than the designed strength (c) Neither more nor less than the designed strength (d) None

Last Answer : (b) Less than the designed strength

Description : Pick up the wrong nominal internal diameter of cast iron (spun) pipes in mm from the following: (A) 300 (B) 400 (C) 550 (D) 650

Last Answer : (C) 550

Description : Cast iron pipes (A) Are widely used in city water supplies (B) Resist corrosion satisfactorily (C) May last for 100 years (D) All the above

Last Answer : (D) All the above

Description : The cast iron pipes for water supply system are used for  (A) Durability  (B) Strength  (C) Easy connection  (D) All the above

Last Answer : (D) All the above

Description : The maximum pressure to which cast iron pipes may be subjected to, is  (A) 3 kg/cm2 (B) 5 kg/cm2 (C) 7 kg/cm2 (D) 10 kg/cm

Last Answer : (C) 7 kg/cm

Description : Manholes are less common in  (A) Cast iron pipes  (B) Steel pipes  (C) Hume steel pipes  (D) R.C.C. pipes

Last Answer : (A) Cast iron pipes 

Description : Pick up the correct statement from the following:  (A) Copper pipes are highly resistant to acidic and alkaline water  (B) Wrought iron pipes are lighter than cast iron pipes  (C) Wrought iron pipes corrode quickly and are less durable  (D) All the above

Last Answer : (D) All the above

Description : Cast iron is used for (A) Structural works in beams (B) Small sized water pipes (C) Columns and struts (D) None to these

Last Answer : Answer: Option C

Description : A flanged joint is composed of all but which of the following? a) The flange b) The bolts. c) The assembly method d) The gasket.

Last Answer : b) The bolts

Description : Service connections to consumers houses, are generally provided with (A) Copper pipes (B) Hume pipes (C) Galvanised iron pipes (D) P.V.C. pipe

Last Answer : (C) Galvanised iron pipes

Description : In a well planned city, the layout of distribution pipes generally adopted, is  (A) Grid-iron system  (B) Interlaced system  (C) Reticulation system  (D) All the above 

Last Answer : (D) All the above 

Description : Is sulfuric acid safe to clean old cast iron drain pipes?

Last Answer : I'm not sure, I believe so though.

Description : Cast iron and steel pipes are produced by __________ casting. (A) Die (B) Investment (C) Slush (D) True centrifugal

Last Answer : (D) True centrifugal

Description : For handling sulphuric acid of 95% strength, the suitable material of construction for pipes is (A) Stainless steel (B) Cast iron (C) Aluminium (D) Nickel

Last Answer : (B) Cast iron

Description : Lead is poured into the joints between two __________ pipes. (A) Cast iron (B) Steel (C) Concrete (D) Plastic

Last Answer : (A) Cast iron

Description : Which one of the following pairs of structures is correctly matched with their corrected description? Structures Description (a) Tibia and fibula Both form parts of knee joint (b) Cartilage and cornea No ... and socket type elbow joint of joint (d) Premolars and molars 20 in all and 3 rooted

Last Answer : (b) it is a non-living layer

Description : How common is it to feel a joint pop out of it's socket?

Last Answer : You might want to speak to your doctor. The tearing is upsetting. I doubt they’re actually dislocating, but it’s probably kind of not good on your joints.

Description : What is the location of a ball and socket joint in the human body? -Biology

Last Answer : answer:

Description : What is a ball and socket joint? -Biology

Last Answer : answer:

Description : Friction is lessened in ball-and-socket joint by

Last Answer : Friction is lessened in ball-and-socket joint by A. Coelomic fluid B. Synovial fluid C. Pericardial fluid D. Mucin

Description : Which of the following is/are not correctly matched pairs? (i) Ball and socket joint -Between humerus and pectoral girdle (ii) Pivot joint - Between c

Last Answer : Which of the following is/are not correctly matched pairs? (i) Ball and socket joint -Between humerus and pectoral ... , b-iii, c-ii, d-v, e-iv`

Description : How a ball and socket joint work?

Last Answer : allow the joints to move in any direction.

Description : A backing ring is used inside the pipe joint when making a (a) butt weld (b) fillet weld (c) sleeve weld (d) socket weld (e) tube weld.

Last Answer : (a) butt weld

Description : A knuckle joint is also called socket pin joint. a) True b) False

Last Answer : b) False

Description : Elbow joint is an example of (a) hinge joint (b) gliding joint (c) ball and socket joint (d) pivot joint.

Last Answer : (a) hinge joint

Description : Which of the following joints would allow no movements? (a) Synovial joint (b) Ball and socket joint (c) Fibrous joint (d) Cartilaginous joint

Last Answer : (c) Fibrous joint

Description : The knuckle joint is made up of... A. Cast iron B. stainless Steel C. Teflon D. All of the above

Last Answer : D. All of the above

Description : 221 For non-scouring velocity 5 m/sec, the type of sewers generally preferred to, is A. Cast iron sewers B. Cement concrete sewers C. Glazed bricks sewers D. Stone ware sewers

Last Answer : ANS: C

Description : Secondary steel has to be provided across__________ of flanged beams [ A ] Full effective width of flange [ B ] The width of web [ C ] Half of the width of flange [ D ] None of the above.

Last Answer : [ A ] Full effective width of flange

Description : Flanged beams are preferred when the concrete in the slab is on the [ A ] compression side of the beam [ B ] tension side of the beam [ C ] may be compression side or tension side of the beam [ D ] none of the above

Last Answer : [ A ] compression side of the beam

Description : Flanged beams are preferred when the concrete in the slab is on the [ A ] compression side of the beam [ B ] tension side of the beam [ C ] may be compression side or tension side of the beam [ D ] none of the above

Last Answer : [ A ] compression side of the beam

Description : Air valves are generally provided in pressure pipes of water supply  (A) At pipe junctions  (B) At summits  (C) At low points  (D) Near service pipes 

Last Answer : (B) At summits 

Description : House connections to the laterals is generally made by A. R.C.C. B. P.C.C. C. Cast iron D. Glazed stonewares

Last Answer : ANS: D